• 제목/요약/키워드: chromium(VI)

검색결과 157건 처리시간 0.025초

Simultaneous Adsorption of Chromium (VI) and Phosphate by Calcined Mg-Al-CO3 Layered Double Hydroxides

  • Song, Xiulan;Wu, Yuhong
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권6호
    • /
    • pp.1817-1824
    • /
    • 2014
  • The adsorption characteristics of chromium (VI) and phosphate on calcined Mg-Al-$CO_3$ layered double hydroxides (CLDH) were investigated in single and binary systems. A series of batch experiments were performed to study the influence of various experimental parameters. In this study, CLDH exhibited a high adsorption capacity for Cr (VI) and P in a single system. The experimental data were close to the theoretical adsorption capacity given by the Langmuir isotherm, the calculating adsorption capacities of Cr (VI) and P were up to 70.42 mg/g and 97.09 mg/g, respectively. It was found that the initial pH was approximately 6 and it took 24 h to reach equilibrium when P and Cr (VI) were added simultaneously. The experimental data were best fitted by a pseudo-second-order kinetics model. Competitive adsorption between Cr (VI) and P existed in the binary system. The presence of Cr (VI) had no significant influence on P adsorption. However, the suppression of Cr (VI) adsorption was obvious when the initial concentration of P was up to 10 mg/L with a concentration of 0.5 g/L of CLDH.

Spectrophotometric Determination of Ultra trace Tri & Hexavalent Chromium by Using on-line Flow Injection Analysis with Dual Pre-concentration Column

  • Jung, Sung-Woon;Lim, Hyun-Woo;Kang, Chul-Ho;Choi, Yong-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권9호
    • /
    • pp.3437-3442
    • /
    • 2011
  • An on-line flow injection analysis with dual pre-concentration method was developed to determine the ultra trace tri and hexavalent chromium in water. In this system, the cation and anion pre-concentration columns were combined with a 10-port injection valve and then used to separate and concentrate Cr (III) and Cr (VI) selectively. The two species of concentrated chromium were sequentially eluted and determined by using HCl-KCl buffer of pH 1.8 as an eluent. Cr (III) was oxidized by hydrogen peroxide to Cr (VI). It was detected spectrophotometrically at 548 nm by complexation with DPC (diphenylcarbazide). Several factors such as concentration of $H_2O_2$, DPC and coil length in reaction condition were optimized. The linear range for Cr (III) and Cr (VI) was 0.1-50 ${\mu}g$/L. The limit of detections ($3{\sigma}$) of Cr (III) and Cr (VI) were 52 ng/L and 44 ng/L under the optimized FIA system, and their recoveries 98% and 103%, respectively. This method was applied to analyze contamination level of chromium species in tap water, groundwater and bottled water.

공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도- (Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures)

  • 신용철;이병규;이지태
    • 한국대기환경학회지
    • /
    • 제18권1호
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

현장 도금 공정에서 PVC 여과지에 채취된 6가 크롬의 환원 (Reduction of Hexavalent Chromium Collected on PVC Filters in Field Electroplating Process)

  • 신용철;백남원;이광용;이병규;이지태
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.41-49
    • /
    • 2002
  • Recently, pilot studies showed an evidence of reduction of airborne hexavalent chromium, Cr(VI), on PVC filter during air sampling and storage. However, the information on this in the field was limited. Thus, we studied the reduction behaviors of airborne Cr(VI) on PVC filters during sampling and storage at three field electroplating operations. Regression between sampling time and the reduction (ratio of Cr(VI) to total Cr concentrations) was not statistically significant (p>0.05). However, the reductions in samples collected for 240 ~ 340 minutes were significantly higher than those for 30 - 60 minutes. On the other hand, another experiment showed a good correlation (r=0.96) between sampling time and the reduction without an exceptional value. Storage temperature was not a factor affecting the reduction of Cr(VI) collected on PVC filter. The loss of Cr(VI) samples stored in alkali solution (2% NaOH/3% Na$_2$CO$_3$) was significantly lower than that stored in vial according to NIOSH method (p<0.05). Thus, dipping Cr(VI) samples into alkali solution was a storage method to minimize tile reduction.

모 조선업체 아크 용접 작업자의 공기중 6가 크롬 및 니켈 노출에 관한 연구 (Welder's Exposure to Airborne Hexavalent Chromium and Nickel during Arc Welding in a Shipyard)

  • 신용철;이광용;이나루;오세민;강성규;문영한;이기라
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.209-223
    • /
    • 1998
  • The aim of this study was to evaluate welders' exposure to hexavalent chromium (Cr(VI)) and nickel (Ni) during welding operations in a Korean shipyard. The airborne Cr(VI) and Ni concentrations were measured during metal inert gas (MIG) welding on mild and stainless steel, and manual metal arc (MMA) welding on mild steel. The geometric mean (GM) of Cr(VI) concentrations inside the welding helmet during MIG welding on mild steel were $0.0018mg/m^3$ inside a ship section, and $0.0015-0.0026mg/m^3$ at the welding shops. All of the personal breathing zone air samples were below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$) of $0.01mg/m^3$. Conversely, eighty-eight percent(21 of 24) of the personal breathing zone air samples exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit of $0.001mg/m^3$. Ni was not detected on 20 of 23 air samples collected during MIG welding on mild steel. The three Ni samples above the limit of detection ranged from 0.015 to $0.044mg/m^3$. The GM of Cr(VI) concentrations during MMA welding on mild steel were $0.0013mg/m^3$, but Ni was not detected in the air samples during this operation. It is assumed that the airborne Cr(VI) and Ni during mild steel welding were derived from the base metals which contained about 0.03% Cr and 0.03% Ni. The GM of airborne total Cr, Cr(VI) and Ni concentrations during MIG welding on stainless steel were 4.02, 0.13 and $0.86mg/m^3$, respectively, and the levels of Cr(VI) and Ni were above the ACGIH-$TLV^{(R)}$. Cr(VI) comprised about 35.5% of the total chromium(Cr) from MIG welding on mild steel, and about 8.4% of total Cr from MIG welding on stainless steel. The ratios of Cr(VI) to total Cr were significantly different among welding shops. It was concluded that welders were exposed to high levels of Cr(VI) and Ni during welding on stainless steel, and were exposed to low levels of Cr(VI) even during welding on mild steel.

  • PDF

운반체 함침 유화액막에 의한 폐수중 크롬(VI)의 이동속도 (Tansport Rate of Chromium ion from Waste Water through the Liquid Surfactant Membrane Containing Carrier)

  • 우인성;김경호;이상진;강안수;최세영
    • Elastomers and Composites
    • /
    • 제23권1호
    • /
    • pp.11-17
    • /
    • 1988
  • The transport of chromium(VI) ion from waste water through the liquid surfactant membrane containing tri-n-octylamine as a carrier, was analyzed by a slab model and was investigated through experiments. For the experiment of membrane stability, concentrations of surfactant and liquid paraffin oil were analyzed. Extraction experiments were carried out to observe the effect of system variables, such as concentrations of carrier, and initial chromium(VI) ion in external aqueous phase at $25^{\circ}C$. It is concluded that the most stable formation of liquid membrane emulsion was obtained when surfactant concentration is above 3 wt.% and liquid paraffin oil concentration is 50 vol.%. The theoretical equation on the transport of chromium(VI) ion agreed well with the experimental results.

  • PDF

6가 크롬 및 유류 제거를 위한 우모 폐기물의 이용가능성 (Availability of Chicken Feather for Removal of Hexavalent Chromium and Oil)

  • 정진하;이나리;박성보;정성윤;박근태;손홍주
    • 한국환경과학회지
    • /
    • 제21권3호
    • /
    • pp.369-375
    • /
    • 2012
  • We investigated usefulness of chicken feather as bioadsorbent for removal of hexavalent chromium[Cr(VI)] and oil from aqueous solution. Chicken feather was chemically treated with DTPA, EDTA, NaOH and SDS, respectively. Among them, EDTA was the most effective in adsorbing Cr(VI). Cr(VI) uptake by chicken feather was increased with decreasing pH; the highest Cr(VI) uptake was observed at pH 2.0. By increasing Cr(VI) concentration, Cr(VI) uptake was increased, and maximum Cr(VI) uptake was 0.34 mmol/g. Cr(VI) adsorption by chicken feather was well described by Freundlich isotherm than Langmuir isotherm and Freundlich constant(1/n) was 0.476. As the concentration of chicken feather was increased, Cr (VI) removal efficiency was increased but Cr(VI) uptake was decreased. Most of Cr(VI) was adsorbed at early reaction stage(1 h) and adsorption equilibrium was established at 5 h. On the other hand, chicken feather adsorbed effectively oils including bunker-A and bunker-C. In conclusion, our results suggest that chicken feather waste could be used to remove heavy metal and oil; it is a potential candidate for biosorption material.

구연산철 환원 조건하에서 Shewanella sp. HN-41에 의한 6가 크롬의 환원 (Reduction of Hexavalent Chromium by Shewanella sp. HN-41 in the Presence of Ferric-Citrate)

  • 박혜민;곽진협;이지훈
    • 한국환경농학회지
    • /
    • 제42권3호
    • /
    • pp.253-258
    • /
    • 2023
  • In the environment, chromium often exists in a highly mobile and toxic form of Cr(VI). Therefore, the reduction of Cr(VI) to less toxic Cr(III) is considered an effective remediation strategy for Cr(VI)-contamination. In this study, the biological reduction of hexavalent chromium was examined at the concentrations of 0.01 mM, 0.1 mM, and 1 mM Cr(VI) by the dissimilatory metal-reducing bacterium, Shewanella sp. HN-41 in the presence of ferric-citrate. With the relatively condensed cell densities, the aqueous phase Cr(VI) was reduced at the proportions of 42%, 23%, and 31%, respectively for the 0.01 mM, 0.1 mM, and 1 mM Cr(VI) incubations, while Fe(III)-citrate was reduced at 95%, 88%, and 73%, respectively. Although the strain HN-41 was not considered to reduce Cr(VI) as the sole electron acceptor for anaerobic metabolism in the preliminary experiment, it has been presumed that outer-membrane c-type cytochromes such as MtrC and OmcA reduced Cr(VI) in the presence of ferric-citrate as the electron acceptor. Since this study indicated the potential of relatively high cell density for Cr(VI) reduction, it might propose a bioremediation strategy for Cr(VI) removal from contaminated waters using engineered systems such as bioreactors employing high cell growths.

한강수계해서의 크롬(III,VI) 종(species) 분포 및 분석방법 정립 (New Analytical Method to Identify Chromium Species, Cr(III) and Cr(VI), and Characteristic Distribution of Chromium Species in the Han River)

  • 정관조;김덕찬;박현
    • 대한환경공학회지
    • /
    • 제27권6호
    • /
    • pp.590-598
    • /
    • 2005
  • 본 연구에서는 HPLC와 DRC ICP-MS를 연결하여 수중의 Cr(III)와 Cr(VI) 측정을 위한 최적의 분석조건을 설정하고, 서울시 6개 취수장 원수에서의 Cr(III)와 Cr(VI)의 분포 특성을 조사하였다. 크롬 종(species) 분리를 위한 HPLC 이동상으로는 tetrabutylammonium phosphate monobasic(1.0 mM TBAP), ethylenediaminetetraacetic acid(0.6 mM EDTA) 그리고 2% v/v 메탄올을 사용하였으며, flushing solvent로는 5% v/v 메탄올을 사용하였다. 또한 크롬 종 분리 시 방해물질인 $ArC^+$의 제거를 위한 반응가스로 암모니아($NH_3$) 가스를 사용하였으며, Cr(III)와 Cr(VI)의 최적의 분리를 위해 이동상의 solvent ratio, pH 유속 및 시료 주입량의 변화에 따른 시험을 실시하였다. 외국의 경우 Cr(III)가 Cr(VI)보다 분석 감도가 우수한 것으로 보고되고 있으나 본 연구 결과 반응가스($NH_3$)를 사용할 경우, Cr(III)에 비해 Cr(VI)의 분석 감도가 더 우수한 것으로 나타났으며, 검출한계는 Cr(III)와 Cr(VI)에 대해 각각 $0.061\;{\mu}g/L$, $0.052\;{\mu}g/L$로 분석시간은 3분 이내로 나타났다. 서울시 6개 취수장 원수에서의 Cr(III)는 $0.048{\sim}0.064\;{\mu}g/L$(평균 $0.054\;{\mu}g/L$), Cr(VI)는 $0.014{\sim}0.023\;{\mu}g/L$(평균 $0.019\;{\mu}g/L$)의 농도 범위로 검출되었다. 회수율은 $90.1{\sim}94.1%$ 범위로 우수하게 나타났으며, Cr(III)가 Cr(VI)에 비해 $2{\sim}3$배 정도 높은 농도로 나타났다.