Wear behaviors of HVOF spray coating of Co-alloy T800

  • Cho, Tong-Yul;Yoon, Jae-Hong;Kim, Kil-Su;Park, Bong-Kyu;Youn, Suk-Jo;Back, Nam-Ki;Chun, Hui-Gon
    • 한국결정성장학회지
    • /
    • 제16권3호
    • /
    • pp.121-126
    • /
    • 2006
  • HVOF thermal spray coating of Co-alloy T800 is progressively replacing the classical hard coatings such as chrome plating because of the very toxic $Cr^{6+}$ ion known as carcinogen causing lung cancer. For the study of the possibility of replacing of chrome plating, the wear properties of HVOF Co-alloy T800 coatings are investigated using the reciprocating sliding tester both at room and at an elevated temperature of $1000^{\circ}F\;(538^{\circ}C)$. The possibility as durability improvement coating is studied for the application to the high speed spindles vulnerable to frictional heat and wear. Wear mechanisms at the reciprocating sliding wear test are studied for the application to the systems similar to the sliding test such as high speed spindles. Wear debris and frictional coefficients of T800 coatings both at room and at an elevated temperature of $1000^{\circ}F\;(538^{\circ}C)$ are drastically reduced compared to those of non-coated surface of parent substrate Inconel 718. This study shows that the coating is recommendable for the durability improvement coatings on the surfaces vulnerable to frictional heat. The sliding surfaces are weared by the mixed mechanisms such as oxidative wear, abrasion by the sliding ball slurry erosion by the mixture of solid particles and small drops of the melts and semi-melts of the attrited particles cavitation by the relative motions among the coating, sliding ball, the melts and semi-melts. and corrosive wear. The oxide particles and the melts and semi-melts play roles as solid and liquid lubricant reducing the wear and friction coefficient.

베릴륨 불포함 치과 주조용 니켈-크롬 합금 중 금속의치상용 합금과 금속소부도재관용 합금의 부식에 관한연구 (Corrosion of the non-beryllium dental casting Ni-Cr alloys for the denture base framework metal and the porcelain-fused-to-metal crown)

  • 김홍식;송재상;박수철
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.337-344
    • /
    • 2012
  • Purpose: This study examined the corrosion level by alloy type and pH, and used the corrosion levels as the dental health data. The study utilized one Ni-Cr alloy for the full and removable partial denture metal frameworks and two Ni-Cr alloys for porcelain-fused-to-metal crown, among the non-beryllium dental casting non-precious Ni-Cr alloys. Methods: The alloy specimens were manufactured in $10cm^2$ and stored in the corrosive solution(pH 2.2-4.4) in the electrical water bath($37^{\circ}C$) for seven days. Afterwards, the metal ions were quantitatively analyzed using the ICP. Results: Of the three metal alloys, Bellabond-Plus$^{(R)}$alloy and SOLIBOND N$^{(R)}$alloy, with 22% or higher chrome chemical contents, had higher corrosion resistance than Jdium-100$^{(R)}$alloy with 20% chrome chemical content. In all three alloys, the corrosion of Ni was highest, and metal ion corrosion was higher in the pH 2.2 corrosive solution. Conclusion: Although Ni-Cr alloy was not very corrosive, a Ni-allergic patient should not have Ni-Cr alloy prosthesis. The Ni-Cr alloy for porcelain-fused-to-metal crown should be designed for the dental porcelain to cover the whole crown.

The properties and wear behavior of HVOF spray coating layer of Co-alloy powder

  • Cho, Tong-Yul;Yoon, Jae-Hong;Kim, Kil-Su;Youn, Suk-Jo;Back, Nam-Ki;Chun, Hui-Gon
    • 한국결정성장학회지
    • /
    • 제16권6호
    • /
    • pp.273-277
    • /
    • 2006
  • High velocity of oxy-fuel (HVOF) thermal spray coating is progressively replacing the other classical hard coatings such as chrome plating and ceramic coating by the classical methods, since the very toxic $Cr^{6+}$ ion is well known as carcinogen causing lung cancer, and the ceramic coatings are brittle. Co-alloy T800 powder is coated on the Inconel 718 substrates by the HVOF coating procesess developed by this laboratory. For the study of the possibility of replacing of chrome plating, the wear properties of HVOF Co-alloy T800 coatings are investigated using the reciprocating sliding tester with a counter sliding SUS 304 ball both at room and at an elevated temperature of $1000^{\circ}F\;(538^{\circ}C)$. The possibility as durability improvement coating is studied for the application to the high speed spindles vulnerable to frictional heat and wear. Wear mechanisms at the reciprocating sliding wear test are studied far the application to the systems similar to the sliding test such as high speed spindles. Wear debris and frictional coefficients of T800 coatings both at room and at an elevated temperature of $538^{\circ}C$ are drastically reduced compared to those of non-coated surface of Inconel 718 substrates. Wear traces and friction coefficients of both coated and non-coated surfaces are drastically reduced at a high temperature of $538^{\circ}C$ compared with those at room temperature. These show that the coating is highly recommendable far the durability Improvement coating on the surfaces vulnerable to frictional heat and wear.

Vibrio mimicus ATCC 33653이 생산하는 Siderophore의 정제와 균의 병원성에 미치는 영향 (Purification Siderophore from Vibrio mimicus ATCC 33653 and its Effect to Bacterial Pathogenecity)

  • 박수정;주성아;허문수;정초록;주진우
    • 대한미생물학회지
    • /
    • 제34권5호
    • /
    • pp.461-470
    • /
    • 1999
  • Growth under conditions of iron-restriction and the production of siderophore was examined in Vibrio mimicus ATCC 33653. This strain grew and multiplied in the presence of the high-affinity iron chelators ethylenediamine-di (o-hydroxyphenylacetic acid). Chrome azurol S (CAS) agar and solution were used to detect the production of siderophore under these condition. Siderophore could be detected in the iron-restricted culture supernatants. The siderophore was extracted from iron-restricted culture supernatants by phenol-chloroform-ether method and purified by Dowex ion-exchange and Sephadex G-25 gel filtracton chromatography. The purified siderophore was confirmed by paper chromatography and HPLC. The Purified siderophore enhanced the growth of V. mimicus when the bacterium was grown in iron limited medium. Injection of both the siderohore and the bacteria to mice resulted in more rapid death than that of the only bacteria. However, the siderophore did not show lethality to mice and any toxicity to cell line like HeLa and U937.

  • PDF

원료 등급에 따른 명란의 위생학적 특성 (Sanitary Characterization of Alaska Pollock Theragra chalcogramma Roe by Raw Material Grade)

  • 정효빈;차장우;박선영;윤인성;이정석;허민수;김진수
    • 한국수산과학회지
    • /
    • 제52권4호
    • /
    • pp.334-343
    • /
    • 2019
  • We investigated the sanitary characteristics of Alaska pollock Theragra chalcogramma roe as a raw material based on the standards of several countries. The standards for raw materials of Alaska pollock roe for lead, total mercury, $^{134}Cs+^{137}Cs$, and $^{131}I$ were those of the South Korean Ministry of Food and Drug Safety; Staphylococcus aureus, Salmonella spp., Clostridium botulinum, methyl mercury, $^{134}Cs+^{137}Cs$, $^{131}I$, $^{239}Pu$, and $^{90}Sr$ were those of the United States Food and Drug Administration; lead, methyl mercury, inorganic arsenic, chrome, $^{134}Cs+^{137}Cs$, and $^{131}I$ were those of the Ministry of Agriculture of China; nitrite ion, $^{134}Cs+^{137}Cs$, $^{239}Pu$, and $^{235}U$ were those of the Ministry of Health, Labor and Welfare of Japan; $^{134}Cs+^{137}Cs$, $^{131}I$, $^{239}Pu$, and $^{90}Sr$ were those of Codex; and $^{134}Cs+^{137}Cs$, $^{131}I$, $^{239}Pu$, $^{241}Am$, and $^{90}Sr$ were those of the European Food Safety Authority. The results for the global standard items other than C. botulinum (lead, total mercury, methyl mercury, inorganic arsenic, chrome, $^{134}Cs+^{137}Cs$, and $^{131}I$, S. aureus, and Salmonella spp.) suggest that Alaska pollock roe is safe for use as a raw material.

도금업체 공정별 근로자의 총크롬 및 6가 크롬 노출 평가 (Worker Exposure Assessment on Airborne Total Chromium and Hexavalent Chromium by Process in Electroplating Factories)

  • 이광용;김부욱;신용철
    • 한국산업보건학회지
    • /
    • 제25권1호
    • /
    • pp.89-94
    • /
    • 2015
  • Objectives: The objective of this study was to determine characteristics of workers' exposures to airborne total and hexavalent chromium by job title in electroplating processes. Methods: Total Cr was determined through a modified method based on NIOSH Method 7024. Airborne hexavalent Cr, Cr(VI), was sampled and extracted according to NIOSH Method 7600 and analyzed at 520 nm using an ion chromatograph/visible detector. Results: The geometric mean(GM) of total Cr concentrations from all factories was $11.2{\mu}g/m^3$(GSD=4.9). The GM of Cr(VI) concentrations from all factories was $2.84{\mu}g/m$ (GSD=5.2), and the concentrations among factories were significantly different (p<0.05). The Cr(VI) levels were lower than total Cr levels. Total Cr exposure levels were highest among buffing workers ($21.6{\mu}g/m^3$), but Cr(VI) levels were highest among plating workers($4.15{\mu}g/m^3$). The concentrations of Cr(VI) and total Cr from plating tasks was highly correlated(r=0.91). Conclusions: In the electroplating industry, plating workers were mainly exposed to Cr(VI), but others were not. Oxidation-reduction states of Cr and job titles should be considered in the exposure or risk assessments of chrome electroplating factories.

$Pyoverdin_{2112}$ of Pseudomonas fluorescens 2112 Inhibits Phytophthora capsici, a Red-Pepper Blight-Causing Fungus

  • Kim, Sang-Dal;Lee, Eun-Tag;Lim, Si-Kyu;Nam, Doo-Hyun;Khang, Yong-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • 제13권3호
    • /
    • pp.415-421
    • /
    • 2003
  • A bacterium, Pseudomonas fluorescens 2112, that is antagonistic against a red-pepper blight-causing fungus, Phytophthora capsici, was isolated from the local soil of Gyongju, Korea. This strain formed an orange-colored clear halo zone on chrome azurol S (CAS) blue agar, suggesting the production of a siderophore in addition to an antifungal antibiotic. The optimal culture conditions for siderophore production by P. fluorescens 2112 were 30-h cultivation at $25^{\circ}C$ and pH 6.5 in King's B medium. The presence of $20{\mu}g/ml\;of\;Fe^3+$ ion or EDDHA promoted the production of siderophore in King's B medium. The siderophore was purified from culture broth by CM-Sephadex C-25 and Sephadex G-25 column chromatographies. The UV spectra of the purified siderophore was the same as that of pyoverdins or pseudobactins. The molecular mass was 1,958 Da determined by FAB-rlass spectrometer, and the amino acid composition analysis showed that the purified siderophore consisted of glycine/threonine/serine/glutamic acid/alanine/lysine with the molar ratio of 3:2:1:1:1:1, DL-Threo-${\beta}$-hydroxyaspartic acid and $N^{\delta}$-hydroxyornithine, two of the essential constituents of pyoverdin, were also found. The purified siderophore pyoverdin showed strong in vitro and in vivo antagonistic activities against phytophthora blight-causing P. capsici. Especially in an in vivo pot test, the siderophore protected red-pepper Capsicum annum L. very well from the attack of P. capsici. These results indicated that the purified siderophore of P. fluorescens 2112 played a critical role in the biocontrol of the red-pepper blight disease, equivalent to treatment by P.fluorescens 2112 cells.

부산시내에 산재하는 몇몇 약수터 약수의 수질 (Water Quality of Some Spring Waters in Pusan Area)

  • 김용관;조현서
    • 한국수산과학회지
    • /
    • 제18권6호
    • /
    • pp.538-544
    • /
    • 1985
  • 부산시내에 산재하고 있는 약수터 중에서 시민의 이용 빈도가 높은 5개 지점을 선정하여 이들의 수질관리에 필요한 기초자료를 얻고자 1983년 12월에서 1984년 8월 사이에 5회에 걸쳐 총 25개 시료를 취하여 내용물에 대한 변화범위와 평균치를 나타내면 다음과 같다. pH $5.80{\sim}7.25$,6.60, 수온 ; $6.0{\sim}23.0^{\circ}C,\;12.9^{\circ}C$, 총증발잔류물 $33.0{\sim}325mg/l$, 121.2mg/l ; 알카리도 $4.75{\sim}51.6mg/l$, 24.lmg/l ; 경도 $9.47{\sim}85.0mg/l$, 30.3mg/l, 전기전도도 $0.495{\sim}2.750{\times}^2{\mu}{\mho}/cm,\;1.239{\times}10^2{\mu}{\mho}/cm$ ; 탁도$0.54{\sim}7.80$ NTU, 2.04 NTU ; 과망간산칼륨 소비량 $0.51{\sim}8.47mg/l$, 1.96mg/l ; 염화이온 농도 $4.91{\sim}36.0mg/l$, 12.53mg/l ; 불소이온 ND-0.30ppm, 0.08ppm ; 질산성 질소 ND-8.94mg/l, 1.94mg/l ; 아질산성 질소 ND-0.10mg/l, 0.03mg/l ; 암모니아성 질소 ND-0.16mg/l, 0.03mg/l ; 인산성 인 ND-0.09mg/l, 0.03mg/l ; 규산성 규소 $0.42{\sim}22.7mg/l$, 7.96mg/l ; 구리 ND-10.5ppb, 2.46ppb ; 납 ND-22.7ppb, 3.54ppb ; 아연 ND-103ppb, 21.33ppb ; 철분 $20.3{\sim}2,800ppb$, 801.72ppb 였었다. 비소, 시안, 카드뮴, 마그네슘, 수은, 육가크롬, 페놀 등은 검출되지 않았다. 특히, 지점 1은 총증발잔류물 178.1mg/l, 전기전도도 $2.127{\times}10^2{\mu}{\mho}/cm$, 탁도 3.16NTU, 염화이온 16.32mg/l로서 다른 지점들 보다 월등히 높았다. 영양염류중 규산성 규소의 함량은 강우에 크게 영향을 받았다. 또 불소이온농도는 상수도 수질기준치 1ppm 보다 0.08ppm으로 훨씬 낮았으며, 철분의 농도는 801.72ppb로서 2.7배나 초과하였다.

  • PDF

Shewanella putrefaciens DK-1의 Fe(III) 환원 특성 (Utilization of Various Electron Acceptors in Shewanella putrefaciens DK-l)

  • 조아영;이일규;전은형;안태영
    • 미생물학회지
    • /
    • 제39권3호
    • /
    • pp.175-180
    • /
    • 2003
  • Shewanella putrefaciens DK-1은 그람음성, 통성 혐기성 세균으로 $NO_{3}$, Fe(III), Mn(IV), humic acid와 같은 다양한 전자수용체를 이용한다. S. putrefaciens DK-1의 전자공여체의 이용능력은 제한적이며, lactate나 formate는 좋은 전자공여체로 이용되지만 acetate나 toluene은 이용하지 못하였다. 다양한 전자수용체간의 경쟁을 살펴보기 위해 전자수용체로 Fe(III)와 같이 $NO_{3}^{-}$, $NO_{2}^{-}$를 넣어 주었을 매 Fe(III)의 환원은 저해되었다. 또한 5. putrefaciens DK-1은 전자수용체로 토양에 광범위하게 존재하는 humic acid를 이용하였으며, 환원된 humic acid는 질산염에 의해서 다시 산화되었다. Fe(III) 환원능이 있는 환경 시료를 이용하여 탄소, 질소, 인과 같은 제한 요인이 Fe(III) 환원세균의 활성에 미치는 효과를 조사하였다. 천호지의 저질토와 대호의 농토에 각각 탄소원, 질소원, 인을 첨가해 주었을 경우 S. putrefaciens DK-1과 탄소원을 동시에 첨가해 주었을 때 가장 높은 철 환원능을 보여주었다.

생활폐기물(生活廢棄物) 소각(燒却) 바닥재의 자력선별(磁力選別)에 따른 크롬과 니켈의 거동(擧動) (Effect of magnetic separation in removal of Cr and Ni from municipal solid waste incineration (MSWI) bottom ash)

  • 안지환;엄남일;조계홍;오명환;유광석;한기천;조희찬;한춘;김병곤
    • 자원리싸이클링
    • /
    • 제16권6호
    • /
    • pp.3-9
    • /
    • 2007
  • 생활 폐기물은 대부분 유리류와 자기류뿐만 아니라 많은 양의 iron을 함유하고 있으며 약 $3{\sim}11%$에 달한다. 대부분의 iron은 Ni-Fe와 Ni-Cr-Fe 같은 합금으로 존재하거나, 부식방지와 광택을 위해 Ni와 Cr로 도금된 iron으로 존재하고 있기 때문에 소각로에서 소각될 경우 철 재품 표면에 심하게 파손된 $Fe_3O_4$층과 함께 $NiFe_2O_4$FeCr_2O_4$을 형성하게 되어 바닥재에 존재하게 되어 중금속산화물 층을 형성시킬 수 있다. iron은 자력이 매우 강해 자력선별에 의해 쉽게 선별되며 이러한 효과로 인해 중금속 산화물의 선별까지 얻을 수 있다. 또한 바닥재는 다양한 Ni와 Cr 산화물들을 함유하고 있으며, Ni와 Cr은 강자성을 띈 물질이기 때문에 자력선별에 의해 큰 영향을 받을 수 있다. 따라서 자력선별에 따른 Ni와 Cr의 거동에 대해 조사하였으며 그 밖의 다른 중금속(Cu, Pb, Cd, As)들의 거동 또한 확인해 보았다. 그 결과 Ni와 Cr은 약 $45{\sim}50%$의 선별율을 보였으며, Cu와 Pb는 $15{\sim}20%$을 나타냈다. 또한 자력선별 전과 후의 바닥재에 대해 Ni와 Cr의 용출량을 확인해본 결과 자력선별 후 바닥재의 용출량이 더 낮음을 확인할 수 있었다.