• 제목/요약/키워드: chlorine removal

검색결과 131건 처리시간 0.019초

자외선 및 초음파 공정에 의한 수용액 상의 PCBs 분해 (Removal of PCBs in Aqueous Phase in Ultraviolet (UV), Ultrasonic (US), and UV/US Processes)

  • 이덕영;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권4호
    • /
    • pp.1-7
    • /
    • 2021
  • The removal of PCBs (Polychlorinated biphenyls) in aqueous phase was investigated in the ultraviolet (UV) process, ultrasonics (US) process and ultraviolet/ultrasonic (UV/US) process using PCB No.7 and Aroclor 1260. For PCB No.7 relatively high removal efficiency over 90% was obtained during 20 min in the UV process and UV/US process. On the other hand, lower removal efficiency of 50 - 70% was achieved for it consisted of individual congeners of PCBs containing 3~8 of chlorine atom. It was found that the dechlorination reaction (the photolytic cleavage of C-Cl bond) was considered as a main removal mechanism in the UV process while PCBs were removed by cavitation-induced radical reaction in the US process. No significant dechlorination occurred in the US process. Consequently, it was suggested that the UV process or UV/US process was applicable for the removal of PCBs in aqueous phase in terms of the removal efficiency and operation time. In addition, the application of saturating gas such as Ar and Air could be considered to control redox condition and enhance the severity of acoustic cavitation for the removal of PCBs.

섬유여과기와 전기분해조를 병합한 물 재이용 시스템 설계 (Design of a Water Reuse System Combined with a Fiber Filtration and Electrolysis)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제24권11호
    • /
    • pp.1385-1391
    • /
    • 2015
  • A water reuse system was designed for a demonstration plant by combining fiber filtration and electrolysis. A discharged dye wastewater after treated with biomedia was used in this study. It was found that an additional removal of suspended solids (SS) was feasible with 2-stage filtration while electrolysis was not effective. Also, $COD_{cr}$ and $COD_{Mn}$ were not removed with 2 -stage filtration but electrolysis resulted in about 26.9% additional removal. This indicates that electrolysis play an important role in organic removal. Removal of T-N and T-P was negligible with 1 and 2-stage fiber filtration and low-level electrolyte. However, with 2000 ppm of electrolyte, their removal efficiencies were about 83.1 and 60%, respectively, suggesting that the removal rates are well associated with the electrolyte concentrations. With high-level electrolyte, colority was removed about 82% while chlorine ions were removed only about 10%. Therefore, to treat underground water containing high-level salinity in the follow-up study, based on the results in this paper, a combined system with selection of additional unit process and reverse osmosis will be designed.

도금폐수 중 시안(CN)의 선택적 제거를 위한 Ferrate (VI) 적용 (Application of Ferrate (VI) for Selective Removal of Cyanide from Plated Wastewater)

  • 양승현;김영희
    • 청정기술
    • /
    • 제27권2호
    • /
    • pp.168-173
    • /
    • 2021
  • 도금폐수의 처리는 폐수의 pH, 중금속 및 시안(CN)함유에 따라 다양하고 복잡한 공정이 적용된다. 이중 시안(CN)의 처리는 차아염소산(NaOCl)을 이용한 알칼리 염소 처리법이 일반적으로 많이 사용되고 있다. 그러나, 암모니아성 질소(NH3-N)와 시안(CN)이 동시에 함유될 경우 암모니아성 질소(NH3-N)의 처리를 위해 차아염소산(NaOCl) 이 과다하게 소비되는 문제가 있다. 이러한 문제를 해결하기 위하여 본 연구는 시안(CN)처리에 있어서 1) 알칼리염소법에서 암모니아성 질소(NH3-N)농도에 따른 차아염소산(NaOCl)의 소모량을 조사하고 2) ferrate (VI)가 시안(CN)을 선택적으로 처리할 수 있는지를 평가하였다. 모의폐수를 이용한 실험결과 알칼리염소법에서는 암모니아성 질소(NH3-N)농도가 높을수록 시안(CN)의 제거율이 감소하였으며 차아염소산(NaOCl)의 소비량이 암모니아성 질소(NH3-N) 농도에 따라 선형적으로 증가하였다. Ferrate (VI)를 이용한 시안(CN) 제거에서는 암모니아성 질소(NH3-N) 농도에 관계없이 시안(CN)의 제거를 확인하였으며 이때 암모니아성 질소(NH3-N)의 제거율은 낮아 ferrate (VI)가 시안(CN)을 선택적으로 제거함을 확인하였다. Ferrate (VI)의 시안(CN) 제거효율은 pH가 낮을수록 높게 나타났고 ferrate (VI) 주입량에 관계없이 99% 이상을 보였다. 실제 도금폐수에 적용한 결과에서는 ferrate (VI)와 시안(CN)의 투입 몰비 1:1에서 99% 이상의 높은 제거율을 보였으며 이는 화학양론 반응식의 몰비와 일치하는 결과로 모의 폐수와 동일하게 암모니아성 질소(NH3-N) 및 기타오염물질이 함유된 실제 폐수에서도 선택적으로 시안(CN)을 제거하는 것으로 확인되었다.

정수처리에서 제올라이트 여과를 이용한 암모니아성질소의 제거와 재생 (Ammonium Ion Removal and Regeneration for Zeolite Filtration in Drinking Water Treatment)

  • 김우향;이승희
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.661-665
    • /
    • 2004
  • As the concentration of ammonium nitrogen could be reached 2~3 mg/L in the winter in the river. It was clear that the excessive concentration of chlorinated organics could be produced with the increase of chlorine addition to remove ammonium nitrogen. In the innovative ammonium nitrogen removal process, zeolite adsorption is very efficient as substitute for rapid sand filtration without other adverse quality change in the water. This study is conducted to evaluate the feasibility of ammonium nitrogen removal and regeneration by zeolite adsorption in drinking water treatment. Also, the reuse possibility of zeolite is evaluated to change the removal efficiency of ammonium nitrogen through several times of regeneration. The ammonium nitrogen was not removed in sand filter, but it was almost removed in zeolite filter during 7 days. The sand and zeolite filters have a similar result of turbidity removal. Therefore, zeolite filtration was confirmed the removal of turbidity and ammonium nitrogen as a media. When compared KCl with NaCl as a chemical for zeolite regeneration, it is demonstrated that KCl was more efficient than NaCl in the ability of zeolite regeneration. The adsorption rate of ammonium nitrogen was almost not decreased in the results of several times of regeneration. It is indicated that both zeolite and regeneration solution were possible to reuse without variation of regeneration rate through this study.

CONTROL OF DIATOM BY PREOXIDATION AND COAGULATION IN WATER TREATMENT

  • Seo, Jeong-Mi;Kong, Dong-Soo;Ahn, Seoung-Koo;Kim, Hyun-Ook
    • Environmental Engineering Research
    • /
    • 제11권1호
    • /
    • pp.45-53
    • /
    • 2006
  • Conventional coagulation is still the main treatment process for algae removal in water treatment. The coagulation efficiency can be significantly improved by the preoxidation of algae-containing water. Jar test was conducted to determine the optimal condition for the removal of diatoms, especially Cyclotella sp. by preoxidation and the subsequent coagulation. The effects of various concentration of PAC (Polyaluminum chloride) on coagulation with and without preoxidation using chlorine or potassium permanganate at different pHs (7.7 and 9.0) were evaluated. At pH 7.7, preoxidation with 2ppm $Cl_2$ followed by coagulation with 7.5 ppm PAC coagulant could reduce Cyclotella sp. concentration by 86%. At pH 9.0, preoxidation with 1 mg $KMnO_4/L$ followed by coagulation with 12.5 ppm PAC coagulant reduced Cyclotella sp. concentration by 85%. Non-linear regression was applied to determine the optimal condition. At pH 7.7 and 9.0, R was over 0.9, respectively. The pH of algal blooming water is over 9.0. Algae (diatom; Cyelotella sp.) can be controlled in the following ways: preoxidation with 1 mg $KMnO_4/L$ followed by coagulation with 12.5 ppm PAC coagulant can remove 80% algae from water. If water pH is adjusted to 7.7, it was expected that less amount of coagulant (7.5 or 10 mg PAC /L) after preoxidation ($Cl_2$ 2 ppm or $KMnO_4$ 0.33, 1 ppm) would be needed to achieve similar level of algae removal. The oxidation with 0.33ppm $KMnO_4$ followed by coagulation with 7.5 ppm PAC coagulant was preferable due to cost-effectiveness of treatment condition and color problem after treatment.

廢自動車 ASR의 風力 및 比中選別에 의한 處理 硏究 (Treatment of ASR from End-of-Life Vehicles by Air and Gravimetric Separation)

  • 이화영;오종기
    • 자원리싸이클링
    • /
    • 제14권2호
    • /
    • pp.3-9
    • /
    • 2005
  • 폐자동차 ASR으로부터 염소성분을 제거하기 위하여 풍력선별 및 비중선별 실험을 수행하였다. 또한, ASR플라스틱만을 분리하여 물을 매체로 한 비중선별을 실시하였다. ASR 시료는 모두 8 mm이하로 재분쇄하여 선별실험에 사용하였으며, 플라스틱은 3가지 입도로 나누어 비중선별 실험을 하였다. 풍력선별은 공기유량 9~20 M$^3$/hr 범위의 1단계와 공기유량 25~34 M$^3$/hr 범위의 2단계로 나누어 실시하고 각 산물의 비율과 재질분포를 조사하였다. 1단계 풍력선별후 underflow 산물의 비율은 62~66%인 것으로 나타났으며, 공기유량이 큰 2단계 풍력선별에서는 overflow 산물의 비율이 크게 증가하였다. 폐플라스틱만을 대상으로 한 비중선별 실험결과 부유물질이 침강물질에 비해 다소 많게 나타났으며, 염소함량에 있어서는 최대 수백개의 염소함량 차이를 보여 순수 플라스틱의 경우 매우 우수한 염소함유 재질의 분리효과를 얻을 수 있었다.

전기화학적 방법과 활성탄 흡착 연계 공정을 이용한 절임염수 재이용 기술 연구 (A Study on Cabbage Salting Brine Reuse Technology Combining an Electrochemical Method and Activated Carbon Adsorption)

  • 이은실;김대기
    • 한국환경기술학회지
    • /
    • 제19권6호
    • /
    • pp.536-542
    • /
    • 2018
  • 절임염수 재이용을 위한 전기화학적 시스템과 활성탄 흡착시스템 연계를 위한 평가를 수행하였다. 대상 전극은 IrOx/Ti 불용성촉매전극을 사용하였으며, 염분 농도 10 %에서의 전류밀도에 따른 잔류염소 농도 변화와 활성탄을 이용한 잔류된 염소 및 유기물 흡착능을 확인하였다. 실험 결과, $500A/m^2$, $1,000A/m^2$의 경우 인가된 전류량이 0.33 Ah/L일 때 더 이상 잔류염소 농도 증가 없이 일정하게 유지되는 것을 확인하였다. 잔류염소 농도 별 흡착효율 평가 시 단위흡착량은 $Y=0.0066+2.087{\times}10^{-4}b$ 식을 유추할 수 있으며 전기화학 방법에 의한 잔류염소 발생과 활성탄 흡착에 의한 제거 시 단위흡착제거량이 0.33 g/g으로 동일하게 나타나는 것을 확인하였다. 또한 활성탄 최대 유기물 흡착량은 $COD_{Cr}$의 경우 0.021 g/g, $COD_{Mn}$의 경우 0.004 g/g을 확인하였다.

염소 바이패스 더스트를 이용한 염화칼륨 제조 및 중금속 제거 (Preparation of KCl through Removal of Heavy Metals from Chlorine By-Pass Dust)

  • 윤영민;염나리;이갑수;엄선희;이용현;추용식
    • 자원리싸이클링
    • /
    • 제26권2호
    • /
    • pp.11-17
    • /
    • 2017
  • 시멘트 공정에서는 산업부산물 및 생활폐기물 적용에 따른 여러 문제점들이 발생한다. 이들 폐기물 사용에 따라 발생하는 염소 바이패스 더스트의 주성분은 칼륨과 염소이며, 소량의 중금속이 함유되어 있다. 따라서 폐기물 재활용 측면에서, 염소 바이패스 더스트 내 중금속 제거가 필요하다. 본 연구에서는 염소 바이패스 더스트를 용해하여 제조되는 염화칼륨 내 중금속 제거 실험을 진행하였다. 최적의 중금속 제거 조건을 도출하기 위해 증류수 함량, 침전제 투입량을 제어하였다. 이에 따라 제조된 염화칼륨 분말 내 존재하는 중금속 종류 함량 등을 분석하였다. 침전제 투입량 증가에 따라 중금속 Pb의 함량이 감소하였다. A더스트와 증류수의 배합비 1:2, 침전제(NaOCl) 3%, B 더스트와 증류수의 배합비 1:2, 1:3.5, 침전제 3% 조건에서 중금속 Pb, Cd 및 As가 모두 불검출 되었다.

간헐포기 활성슬러지 중수처리공정의 현장적용 연구 (A Study on the Field Application of Intermittently Aerated Activated Sludge Process for Water Reuse System)

  • 서인석;김병군;박승국;권선웅
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.513-521
    • /
    • 2000
  • Intermittently aerated activated sludge process was applied as a water reuse process of $70m^3/day$ for the upgrade of organic, nitrogen and phosphorus removal efficiency and clarifier performance. After application of the intermittently aeration, removal efficiency of BOD, SS, T-N and T-P were achieved 95%, 90%, 80% and 60%, respectively. Removal efficiencies in intermittently aerated process were considerably increased. comparing to those of continuously aerated activated sludge process. Also sludge rising problem in clarifier was improved. Average concentration of supplied reusing water were BOD 5 mg/L, turbidity 4 NTU and after chlorination, residual chlorine 0.4 mg/L, coliform 0 MPN/100mL. Intermittently aerated activated sludge process could be one of the best alternative process for the retrofit of conventional activated sludge process for the removal of nutrient in water reuse system.

  • PDF

정화조의 효율적인 운영을 위한 실험적 고찰 (An Experimental Investigation for Efficient Operation of Septic Tank)

  • 이장훈;이경수;고수훈;송민희;이수현;이용훈;강선홍
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.123-129
    • /
    • 2012
  • A septic tank is a purification treatment system where night soil and other waste matter is converted into harmless material by the activities of bacteria. Effluent from the septic tank flows into the sewer pipe, and then this effluent affects the quality of water environment and makes foul smell. In this study, through the proper maintenance of septic tank it was tried to minimize the impact of sewer pipe on water quality and fouling smell. BOD removal rate from the septic tank's effluent which exceeded legal cleaning period was investigated for the proper maintenance. BOD Removal rate of the twelve septic tank's effluent is -62.5% to 43.9%. According to the result of BOD removal rate, septic tank cleaning should be done at least once a year. And the pathogenic coliform bacillus in the twelve septic tank's effluent is average 768,000 (MPN/$100m{\ell}$). The chlorine disinfection is needed to remove the pathogenic coliform bacillus in septic tank effluent.