• Title/Summary/Keyword: chlorine oxide

Search Result 49, Processing Time 0.027 seconds

The Investigation of Influence of Chlorinated Hydrocarbons on $NO_x$ Formation from Methane Flames (메탄 화염에서 염화 탄화수소 화합물이 질소산화물 생성에 미치는 영향 조사)

  • Jang, Kyoung;Jang, Bong-Choon;Lee, Ki-Yong
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.1
    • /
    • pp.10-16
    • /
    • 2008
  • Numerical simulations of freely propagating premixed flames burning mixtures of methane and chlorinated hydrocarbons in fuel are performed at atmospheric pressure in order to understand the effect of chlorinated hydrocarbons on the formation of nitrogen oxide. A detailed chemical reaction mechanism is used, the adopted scheme involving 89 gas-phase species and 1017 elementary forward reaction steps. Chlorine atoms available from chlorinated hydrocarbons inhibit the formation of nitrogen oxides by lowering the concentration of radical species. The reduction of NO emission index calculated with thermal or prompt NO mechanism is not linear and is probably related to the saturation effect as $CH_3Cl$ addition is increased, In the formation or consumption of nitrogen oxide, the $NO_2$ and NOCl reactions play an important role in lean flames while the HNO reactions do in rich flames. The molar ratio of Cl to H in fuel has an effect on the magnitude of NO emission index.

  • PDF

Corrosion Behavior of Inconel X-750 for Carbon Anode Oxide Reduction Application

  • Jeon, Min Ku;Kim, Sung-Wook;Lee, Sang-Kwon;Choi, Eun-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.355-362
    • /
    • 2020
  • The corrosion behavior of the Inconel X-750 alloy was investigated for its potential application under a Cl2-O2 mixed gas flow in an Ar atmosphere. The corrosion rate was found to be negligible at temperatures up to 400℃ under a flow rate of 30 mL·min-1 Cl2 + 170 mL·min-1 Ar, whereas an exponential increase was observed in the corrosion rate at temperatures greater than 500℃. The suppression of the corrosion reaction due to the presence of O2 was verified experimentally at flow rates of 30 mL·min-1 Cl2 (4.96 g·m-2·h-1), 20 mL·min-1 Cl2 + 10 mL·min-1 O2 (2.02 g·m-2 ·h-1), and 10 mL·min-1 Cl2 + 20 mL·min-1 O2 (1.34 g·m-2·h-1) under a constant Ar flow rate of 170 mL·min-1 at 600℃ for 8 h. The surface morphology analysis results revealed that porous surfaces with tunnel-type holes were produced under the Cl2-O2 mixed-gas condition. Furthermore, the effects of the Cl2 flow rate on the corrosion rate were investigated, indicating that its impact was negligible within the range of 5-30 mL·min-1 Cl2 at 600℃.

Combined Treatment on the Inactivation of Naturally Existing Bacteria and Escherichia coli O157:H7 Inoculated on Fresh-Cut Kale

  • Kang, Ji Hoon;Song, Kyung Bin
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.2
    • /
    • pp.219-225
    • /
    • 2017
  • An aqueous chlorine dioxide ($ClO_2$) treatment combined with highly activated calcium oxide (CaO) and mild heat was tested for inactivating naturally existing bacteria and Escherichia coli O157:H7 inoculated on fresh-cut kale. Kale samples were treated with different concentrations of $ClO_2$ (10, 30, and 50 ppm), CaO (0.01%, 0.05%, 0.1%, and 0.2%), and mild heat ($25^{\circ}C$, $45^{\circ}C$, $55^{\circ}C$, and $65^{\circ}C$) as well with combinations of 30 or 50 ppm $ClO_2$ and 0.2% CaO at $55^{\circ}C$ for 3 min. An increasing concentration of $ClO_2$ and CaO significantly reduced the microbial population compared with the control. In addition, mild heating at $55^{\circ}C$ elicited greater microbial reduction than the other temperatures. A combined treatment of 50 ppm $ClO_2$ and 0.2% CaO at $55^{\circ}C$ reduced the population of naturally existing bacteria on kale by 3.10 log colony forming units (CFU)/g, and the counts of E. coli O157:H7 were below the detection limit (1 log CFU/g). In addition, no significant differences in the Hunter color values were evident in any treatment during storage. Therefore, a combined treatment of $ClO_2$ and active CaO at $55^{\circ}C$ can be an effective sanitizing method to improve the microbiological safety of fresh-cut kale without affecting its quality.

Assessment of Priority Order Using the Chemical to Cause to Generate Occupational Diseases and Classification by GHS (직업병발생 물질과 GHS분류 자료를 이용한 화학물질 우선순위 평가)

  • Baik, Nam-Sik;Chung, Jin-Do;Park, Chan-Hee
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.715-735
    • /
    • 2010
  • This study is designed to assess the priority order of the chemicals to cause to generate occupational diseases in order to understand the fundamental data required for the preparation of health protective measure for the workers dealing with chemicals. The 41 types of 51 ones of chemicals to cause to generate the national occupational diseases were selected as the study objects by understanding their domestic use or not, and their occupational diseases' occurrence or not among 110,608 types of domestic and overseas chemicals. To assess their priority order the sum of scores was acquired by understanding the actually classified condition based on a perfect score of physical riskiness(90points) and health toxicity(92points) as a classification standard by GHS, the priority order on GHS riskiness assessment, GHS toxicity assessment, GHS toxic xriskiness assessment(sum of riskiness plus toxicity) was assessed by multiplying each result by each weight of occupational disease's occurrence. The high ranking 5 items of chemicals for GHS riskiness assessment were turned out to be urethane, copper, chlorine, manganese, and thiomersal by order. Besides as a result of GHS toxicity assessment the top fives were assessed to be aluminum, iron oxide, manganese, copper, and cadium(Metal) by order. On the other hand, GHS toxicity riskiness assessment showed that the top fives were assessed to be copper, urethane, iron oxide, chlorine and phenanthrene by order. As there is no material or many uncertain details for physical riskiness or health toxicity by GHS classification though such materials caused to generate the national occupational diseases, it is very urgent to prepare its countermeasure based on the forementioned in order to protect the workers handling or being exposed to chemicals from health.

Enhanced performance of thin-film nanocomposite RO/NWF membrane by adding ZnO nanospheres in aqueous phase during interfacial polymerization process

  • Li, Hongbin;Shi, Wenying;Su, Yuheng;Hou, Hongxiang;Du, Qiyun;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • v.8 no.3
    • /
    • pp.225-244
    • /
    • 2017
  • A novel thin-film nanocomposite (TFN) reverse osmosis (RO)/non-woven fabric (NWF) membrane was prepared by adding zinc oxide (ZnO) nanospheres ($30{\pm}10nm$) during the interfacial polymerization process of m-phenylenediamine (MPD) and trimesoyl chloride (TMC) on self-made polysulfone (PSF) membrane/polyester (PET) non-woven fabric support. The improved performance of TFN RO membrane was verified in terms of water contact angle (WCA), water flux, salt rejection, antifouling properties and chlorine resistance. The results showed that the WCA value of TFN RO surface had a continuous decrease with the increasing of ZnO content in MPD aqueous solution. The water flux of composite TFN RO membranes acquired a remarkable increase with a stable high solute rejection (94.5 %) in $1g{\cdot}L^{-1}$ NaCl aqueous solution under the optimized addition amount of ZnO (1 wt%). The continuous testing of membrane separation performance after the immersion in sodium hypochlorite solution indicated that the introduction of ZnO nanospheres also dramatically enhanced the antifouling properties and the chlorine resistance of composite RO membranes.

Effect of Thermally Grown TiO2 Interlayer on Chlorine Evolution Efficiency and Durability of Ti/RuO2-PdO-TiO2 Electrodes (열산화법으로 생성된 TiO2 중간보호층이 Ti/RuO2-PdO-TiO2전극의 염소발생 효율 및 내구성에 미치는 영향)

  • Park, Da Jung;Choi, Sung Mook;Lee, Kyu Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.4
    • /
    • pp.207-213
    • /
    • 2018
  • Not only efficiency of chlorine evolution reaction (CER) but also durability namely service life is very important property in dimensional stable anode for Ballast Water Management System (BWMS) for marine ships. Many researchers have been focused on improving efficiency of CER by controlling composition, phase and surface area for a long time, but the efforts to increase durability was relatively small. In this study, we have investigated the effect of $TiO_2$ protective interlayers on efficiency and durability of DSA electrodes. $TiO_2$ protective interlayers were prepared by thermal oxidation at 500, 600 and $700^{\circ}C$ on Ti substrate. And then the DSA electrodes consisting of $Ti/RuO_2-PdO-TiO_2$ were prepared by thermal decomposition method on $TiO_2$ interlayers. The efficiencies of CER of DSA electrodes without $TiO_2$ interlayer and with $TiO_2$ interlayer grown at 500, 600 and $700^{\circ}C$ were 94.19, 94.45, 84.60 and 76.75% respectively. On the otherhand, durabilities were 30, 55, 90 and 65 hours respectively. In terms of industrial aspect, the performance of DSA is considered high efficiency and durability which can correspond to total production of chlorine. If we considered the performance index of DSA as the product of efficiency and durability, performance indices could be recalculated as 28.26, 50.85, 76.14 and 49.89 respectively. As the thermal oxidation temperature increasing, life time were increased remarkerbly, while efficiency of CER was decreased slightly. As a result, DSA electrode with $TiO_2$ interlayer grown at $600^{\circ}C$ has shown about 2.7 times performace of original DSA electrode without $TiO_2$ interlayer.

Effect of Brine Treatment Applied in the Manufacture of Traditional Forged High Tin Bronzes of Korea (한국의 방짜유기에 가해지는 염수처리의 효과에 관한 연구)

  • Lee, Jae-Sung;Jeon, Ik-Hwan;Kwak, Seok-Chul;Park, Jang-Sik
    • Journal of Conservation Science
    • /
    • v.28 no.4
    • /
    • pp.403-410
    • /
    • 2012
  • The brine treatment applied during the fabrication of forged high tin bronze objects is considered effective at the removal of surface oxide layers developed at elevated temperatures. There is not much information, however, available for the understanding of its exact effect and purpose. This work performed laboratory experiments to characterize the effect brine treatments produce on the surface of bronze objects during fabrication. Specimens were first made in the bronze shop of the Yongin folk village under varying conditions of brine treatments, and the results obtained were then used in the following laboratory experiments where the effect of brine treatments were investigated in terms of brine concentrations, alloy compositions and thermo-mechanical treatments. The results show that oxide layers generated at high temperature are easily removed by the brine treatment. It was found that the element, chlorine, played a key role in the removal of such oxide layers as opposed to the other constituent of the brine, sodium, makes no notable contribution. In bronze alloys containing 22% tin, this brine effect is obtained regardless of the application of forging as long as the brine concentration is over 0.5% based on weight. In alloys containing lead, however, no brine effect is observed due to the molten lead that emerges from inside the hot bronze specimen and forms a thin layer on its surface.

Study ink-jet ink for surface electron emission materials applied in flat panel display technology

  • Lin, H.M.;Liou, L.W.;Huang, C.Y.;Zheng, J.Y.;Liu, P.Y.;Wu, C.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.270-273
    • /
    • 2006
  • In this study, ink-jet technology is applied to the emitter fabrication for surface-conduction electron-emitter display (SED). The general emiiter material of SED, palladium oxide (PdO), is prepared by calcination the mixture of solvent and precursors of platinum chlorine and platinum nitrate. With controlling the precursors and solvents, the PdO is formed below $400^{\circ}C$ which is required for SED process.

  • PDF

의약품 제조시설의 포름알데히드가스 훈증살균과 최근 실내무균화방법의 동향

  • 한국공기청정협회
    • Air Cleaning Technology
    • /
    • v.23 no.3
    • /
    • pp.34-43
    • /
    • 2010
  • In most productive facility of pharmaceutical companies, the fumigation using formaldehyde gas has been put into operation. Because formaldehyde gas is so bactericidal as to sterilize bacterial spore which can not be sterilized with usual disinfectants, it has been used for fumigation in many facilities such as facility of experimental animals, research institute and productive facility of pharmaceutical companies which are required to be high level of biological clean. However, the use of formaldehyde is recently under the strict management because of its causing of sick house and carcinogenesis. We introduce the conditions of sterilization using formaldehyde gas, the examples of sterilization using formaldehyde gas in a pharmaceutical manufacture and the problems of use of formaldehyde against environments and health. Further, we describe the characteristics and future subjects of the sterilization method using gasified oxidants such as hydrogen peroxide, peracetic acid and chlorine oxide.

  • PDF

A Study on the Preparation of the Dimensionally Stable Anode(DSA) with High Generation Rate of Oxidants(II) (산화제 생성율이 높은 촉매성 산화물 전극(DSA)의 개발에 관한 연구(II))

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.61-72
    • /
    • 2009
  • Fabrication and oxidants production of 3 or 4 components metal oxide electrode, which is known to be so effective to destruct non-biodegradable organics in wastewater, were studied. Five electrode materials (Ru as main component and Pt, Sn, Sb and Gd as minor components) were used for the 3 or 4 components electrode. The metal oxide electrode was prepared by coating the electrode material on the surface of the titanium mesh and then thermal oxidation at $500^{\circ}C$ for 1h. The removed RhB per 2 min and unit W of 3 components electrode was in the order: Ru:Sn:Sb=9:1:1 > Ru:Pt:Gd=5:5:1 > Ru:Sn=9:1 > Ru:Sn:Gd=9:1:1 > Ru:Sb:Gd=9:1:1. Although RhB decolorization of Ru:Sn:Sb:Gd electrode was the highest among the 4 components electrode, the RhB decolorization and oxidants formation of the Ru:Sn:Sb=9:1:1 electrode was higher than that of the 3 and 4 components electrode. Electrogenerated oxidants (free Cl and $ClO_2$) of chlorine type in 3 and 4 components electrode were higher than other oxidants such as $H_2O_2\;and\;O_3$. It was assumed that electrode with high RhB decolorization showed high oxidant generation and COD removal efficiency. OH radical which is electrogenerated by the direct electrolysis was not generated the entire 3 and 4 components electrode, therefore main mechanism of RhB degradation by metal oxide electrode based Ru was considered indirect electrolysis using electrogenerated oxidants.