• 제목/요약/키워드: chiral resolution

검색결과 168건 처리시간 0.028초

Liquid Chromatographic Resolution of Pyrethroic Acids and Their Esters on Chiral Stationary Phases

  • Lee, Won-Jae;Baek, Chae-Sun;Jing, Yu-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.224.2-224.2
    • /
    • 2003
  • Pyrethroic acids are essential chiral intermediates of the pyrethroids, which account for about 25% of the world insecticide market and are found to be some of the most effective commercially available pesticides. It was demonstrated that polysaccharide-derived chiral stationary phases (CSPs) are very efficient for the separation of the enantiomers of pyrethroid acids. It was observed that the enantioseparation of pyrethroic methyl ester and ethyl derivatives was well accomplished on brush-type WhelkO-1. (omitted)

  • PDF

Multivariate Optimization of a Sulfated- β-Cyclodextrin-Modified Capillary Zone Electrophoretic Method for the Separation of Chiral Arylalcohols

  • Zhang, Yu-Ping;Noh, Hyun-Joo;Choi, Seong-Ho;Ryoo, Jae-Jeong;Lee, kwang-Pill;Ohta, Kazutoku;Fujimoto, Chuzo;Jin, Ji-Ye;Takeuchi, Toyohide
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권3호
    • /
    • pp.377-381
    • /
    • 2004
  • Chiral separation of aryalcohols such as 1-phenyl-propanol, 1-phenyl-2-proanol, and 2-phenyl-1-propanol by capillary electrophoresis has been optimized using the overlapping resolution mapping (ORM) scheme. Three critical parameters of the electrophoretic media, i.e. phosphate concentration, sulfated ${\beta}$-cyclodextrin (CD) concentration and pH, were chosen for optimization. The working ranges were initially presumed by 7 preexperiments. Further optimization was carried out by another seven experiments within the narrow working ranges. From the final overlapping resolution mapping all peak pairs, the area of maximum separations were located. Using the conditions of a point in this area, we found that the target compounds were a baseline separated within 30 min. The maximum separation conditions of arylalcohols were a chiral selector concentration of 5.4%, a phosphate concentration of 28 mM, and a pH of 5.0.

Chiral Separation of ${\beta}_2$-Agonists by Capillary Electrophoresis Using Hydroxypropyl-${\alpha}$-Cyclodextrin as a Chiral Selector

  • Kim, Kyeon-Ho;Kim, Hyu-Ju;Jeun, Eu-Young;Seo, San-Hun;Hong, Seon-Pyo;Kang, Jong-Seong;Youm, Jeong-Rok;Lee, Sang-Cheal
    • Archives of Pharmacal Research
    • /
    • 제24권4호
    • /
    • pp.281-285
    • /
    • 2001
  • Enantiomers of five racemic ${\beta}_2$-agonists were investigated by capillary electrophoresis employing a hydroxypropyl-${\beta}$-cyclodextrin (HP-${\beta}$-CD). The effects of the concentration of HP-${\beta}$-CD added to the background electrolyte and of the pH of the buffer on the effective mobility and resolution of the studied compounds were examined. Very good resolution was achieved for terbutaline and clenbuterol; salbutamol and bambuterol was able to be partially resolved. Enantioselectivity and resolution were influenced by the concentration of the HP-7-CD, buffer composition and pH.

  • PDF

Liquid Chromatographic Resolution of Racemic $\alpha$-Amino Acid Derivatives on an Improved $\pi$-Acidic Chiral Stationary Phase Derived from (S)-Leucine

  • 현명호;이승준;류재정
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권10호
    • /
    • pp.1105-1109
    • /
    • 1998
  • A chiral stationary phase derived from (S)-N-(3,5-dinitrobenzoyl)leucine N-phenyl N-alkyl amide (CSP 2) was applied in separating the two enantiomers of various π-basic aromatic derivatives of leucine N-propyl amide in order to evaluate π-basic aromatic groups as an effective derivatizing group for the resolution of a-amino acids. Subsequently N-(3,5-dimethoxybenzoyl) group was found to be very effective as a π-basic aromatic derivatizing group. Based on these results, N-(3,5-dimethoxybenzoyl) derivatives of various a-amino N-propyl amides, N,N-diethyl amides and esters were resolved on the CSP derived from (S)-N-(3,5-dinitrobenzoyl) leucine N-phenyl N-alkyl amide (CSP 2) and the resolution results were compared with those on the CSP derived from (S)-N-(3,5-dinitrobenzoyl)leucine N-alkyl amide (CSP 1). The enantioselectivities exerted by CSP 2 were much greater than those exerted by CSP 1. In addition, racemic N-(3,5-dimethoxybenzoyl)-a-mino N,Ndiethyl amides were resolved much better than the corresponding N-(3,5-dimethoxybenzoyl)-a-mino N-propyl amides and esters on both CSPs. Based on these results, a chiral recognition mechanism utilizing the π-π donor-acceptor interaction and the two hydrogen bondings between the CSP and the analyte was proposed.

Chiral Separation of $\beta$-Blockers after Derivatization with (-)-$\alpa$- Methoxy-$\alpa$-(trifuoromethyl)phenylacetyl Chloride by Gas Chromatography

  • Kim, Kyeong-Ho;Lee, Joo-Hyun;Ko, Mi-Young;Hong, Seon-Pyo;Youm, Jeong-Rok
    • Archives of Pharmacal Research
    • /
    • 제24권5호
    • /
    • pp.402-406
    • /
    • 2001
  • Gas chromatographic method was investigated for the chiral separation of several $\beta$-blockeros(atenolol, betaxolol, bisoprolol, metoprolol and pindolol) using (-)-$\alpa$-methoxy-$\alpa$-(trifluoromethyl)phenylacetyl chloride as a chiral derivatizing agent for amino group. Prior to N-acylation, hydroxyl group was converted into O-silyl ethers by react with N-methyl-H-(taimethylsilyl)trifluoroacetamide. The reaction was selective and rapid and the diasteromeric derivatives were well separated by capillary gas chromatography. (R)-isomers were eluted faster than (S)-isomers when (-)-$\alpa$-methoxy-$\alpa$-(trifluoromethyl)phenylacetyl chloride was used as the chiral derivatizing agent. But in the opposite sequence when (+)-$\alpa$-methoxy-$\alpa$-(trifluoromethyl)phenylacetyl chloride was used. No racemization was found during the reaction.

  • PDF

Preparation of a New Chiral Stationary Phase Based on (2S,3S)-O,O'-Bis-(10-undecenoyl)-N,N'-bis-(3,5-dinitrobenzoyl)-2,3-diamino-1,4-butandiol and Its Application

  • Hyun, Myung Ho;Boo, Chang-Jin;Choi, Hee-Jung;Kim, Yun-Kyoung;Kang, Bu-Sung;Ha, Hyun-Ju;Choi, Min-Ki;Tan, Guang-Hui
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1769-1774
    • /
    • 2006
  • A new liquid chromatographic chiral stationary phase based on (2S,3S)-O,O'-bis-(10-undecenoyl)-N,N'-bis-(3,5-dinitrobenzoyl)-2,3-diamino-1,4-butandiol was prepared starting from (2R,3R)-1,4-bis(benzyloxy)-2,3-butanediol. The new chiral stationary phase was applied to the resolution of racemic anilide derivatives of N-acetyl-a-amino acids, 1,1'-bi-2-naphthol and 3,3'-diaryl-1,1'-bi-2-naphthols. The CSP was also applied to the resolution of some chiral drugs including a diuretic, bendroflumethiazide, and non-steroidal anti-inflammatory agents such naproxen and alminoprofen. In every case, the chiral recognition efficiency of the new CSP was quite excellent.

고성능 액체 크로마토그래피에서 키랄 크라운 에테르로부터 유도된 키랄 고정상을 이용한 광학분리의 비교 (Comparative Enantiomer Separation on Chiral Stationary Phases Derived from Chiral Crown Ether by HPLC)

  • 황호;전소희;김지연;이원재
    • KSBB Journal
    • /
    • 제27권4호
    • /
    • pp.232-236
    • /
    • 2012
  • Comparative liquid chromatographic enantiomer separation of ${\alpha}$-amino acids, their esters and primary amino compounds was performed using two chiral stationary phases (CSPs) prepared by covalently bonding (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18-C-6-TA) of the same chiral selector. In general, the separation factors and resolution factors for these analytes on CSP 1 were greater than on CSP 2, while these capacity factors on CSP 2 were quite greater than on CSP 1. Except for leucine methyl ester and phenylalanine methyl ester, the elution orders of all analytes including ${\alpha}$-amino ${\alpha}$-alkyl acids and phenylglycine alkyl esters on CSP 1 are identical to those on CSP 2. This study showed that different connecting structures for these two CSPs might influence their ability to resolve the analytes depending on their structures related to the chiral recognition mechanism.

키랄 고성능 액체 크로마토그래피를 이용하 이부프로펜의 분리도에 관한 실험식 (Empirical Equation for Resolution if Ibuprofen Enantiomers by Chiral High-Performance Liquid Chromatography)

  • 여미순;노경호
    • KSBB Journal
    • /
    • 제18권4호
    • /
    • pp.261-265
    • /
    • 2003
  • 이부프로펜 중 S-enantiomer는 약물학적 효과를 갖고 있으나 R-enantiomer는 여러 가지 부작용을 갖고 있다. 이런 라세미 혼합물은 키랄 고성능 액체 크로마토그래피를 이용하여 효과적으로 분리 할 수 있었다. 실험에서 이용한 column(3.9 ${\times}$ 300 mm)은 Kromasil 10 $\mu\textrm{m}$를 충진하였고, 이동상으로는 n-hexane/tert-butyl methyl ether/acetic acid를 사용하였다. 유속은 1.0 $m\ell$/min 주입부피는 5 ${\mu}\ell$이고, UV 검출기의 wavelength는 220 nm이며 실온에서 실험하였다. 라세미 형태의 이부프로펜을 키랄 고정상으로 채워진 컬럼을 이용하여 이동상의 조성비를 바꿔가면서 이동상의 조성 변화에 따른 두 물질의 분리도의 상관식을 얻었다. 이 상관식을 이용하여 각 조성에 분리도에 미치는 영향을 정량적으로 표시하였고 보간법 또는 외사법에 의하여 실험이외의 조성에 대한 분리도를 예측할 수 있는 장점이 있다.

키랄 크로마토그래피와 NMR 분광법에 의한 N-acetyl-1-naphthylethylamine의 광학순도 측정 (1Determination of optical purity of N-acetyl-1-naphthylethylamine by chiral chromatography and NMR spectroscopy)

  • 정영한;류재정
    • 분석과학
    • /
    • 제23권1호
    • /
    • pp.97-101
    • /
    • 2010
  • (R)-N-3,5-dinitrobenzoyl (DNB) phenylglycinol로 부터 만들어진 키랄 선택제가 라세미 Nacylnaphthylalkylamines의 분리에 HPLC 키랄 정지상으로 이용된 바 있다. 본 연구에서는 (R)-phenylglycinol 유도체 키랄 선택제를 이용하여 키랄 크로마토그래피와 NMR 분광법에 의한 광학순도를 측정하였다. NMR과 HPLC 실험결과를 참값과 비교하여 각 광학순도 측정값의 정확도와 정밀도를 계산하였다. NMR 방법의 오차는 +2.2%, 평균 RSD는 4.54% 이었고, HPLC 방법의 오차는 -3.5%, 평균 상대표준편차는 3.23% 이었다.