• Title/Summary/Keyword: chiral chromatography

Search Result 115, Processing Time 0.023 seconds

Chiral separation of amino acids in urine specimens from patients with inherited metabolic disorders by achiral gas chromatography

  • Paik, Man-Jeoneg;Choi, Young-Mie;Nguyen, Duc-Toan;Kim, Ji-Yung;Kim, Jung-Han;Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.218.2-218.2
    • /
    • 2003
  • An efficient method is described for the enantioseparation of urinary amino acids to determine their absolute configurations. It involves two-phase extractive ethoxycarbonylation in alkaline aqueous solution with subsequent extraction after acidification. The resulting derivatives of amino acids are converted to volatile diastereomeric esters or amides for the direct analysis by gas chromatography (GC) on achiral dual-columns with different polarities. The present method was applied to urine specimens from patients with inherited metabolic disorders. In this study, the usefulness for the chiral separation of diagnostic amino acids will be discussed.

  • PDF

Resolution of Tocainide and Its Analogues on a Doubly Tethered N-CH3 Amide Chiral Stationary Phase Based on (+)-(18-Crown-6)-2,3,11,12-tetracarboxylic Acid

  • Lee, Kyu Jung;Tak, Kyung Mi;Hyun, Myung Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.2978-2982
    • /
    • 2013
  • A doubly tethered $N-CH_3$ amide chiral stationary phase (CSP 4) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was applied to the resolution of an antiarrythmic agent, tocainide, and its analogues and the chromatographic resolution results were compared with those on a singly tethered N-H amide CSP (CSP 1), a singly tethered $N-CH_3$ amide CSP (CSP 2) and a doubly tethered N-H amide CSP (CSP 3) under an identical aqueous mobile phase condition. CSP 4 was found to be generally better than other CSPs in terms of the separation factors (${\alpha}$) and resolutions (RS). The retention times of analytes denoted by the retention factors ($k_1$) on CSP 4 were quite long compared to those on other CSPs because of the improved lipophilicity of CSP 4. The long retention times of analytes on CSP 4 were successfully controlled by the addition of a small amount of ammonium acetate to aqueous mobile phase without hurting the chiral recognition efficiency. The variation of the content and type of organic and acidic modifier in aqueous mobile phase was found not to change the chiral recognition efficiency significantly.

Chiral Separation of the Enantiomers of Metoprolol and Its Metabolites by High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Shin, Sang-Duk;Lee, Joo-Hyun;Lee, Sang-Cheal;Kang, Jong-Seong;Mar, Woong-chon;Hong, Seon-Pyo;Kim, Hyun-Ju
    • Archives of Pharmacal Research
    • /
    • v.23 no.3
    • /
    • pp.230-236
    • /
    • 2000
  • (1'R, 2R)-, (1'R, 2S)-, (1'S, 2R)- and (1'S, 2S)-$\alpha$-hydroxymetoprolol; (2R)- and (2S)-O-des-methylmetoprolol; and (2R)- and (2S)-metoprolol acid are major metabolites of (2R)-and (2S)-metoprolol, $\beta$-adrenergic antagonist. The focus of most chiral separation methods until now has been on determination of the enantiomeric parent drug. However, it is just as important to be able to follow the metabolism of the enantiomers and their possible chiral metabolites. Therefore, for the study of stereoselective metabolism and pharmacokinetics of metoprolol, the chiral separation of the enantiomers of metoprolol and its metabolites has been investigated using four chiral stationary phases, i.e., Chiralcel OD, Chiral-AGP, Cyclobond I and Sumichiral OA-4900 columns. Metoprolol acid was resolved only by Sumichiral OA-4900. Chiralcel OD provided the highest separation factor and resolution value for metoprolol and O-desmethylmetoprolol and partially resolved the four stereoisomers of $\alpha$-hydroxymetoprolol. Diastereomeric $\alpha$-hydroxymetoprolols were resolved using the coupled column chromatographic system of two chiral stationary phases, Sumichiral OA-4900 column and Chiralcel OD column.

  • PDF

Micro-Determination of D-Amino Acids in Milk by using Column Switching System (Column-Switching System을 이용한 우유속의 D-아미노산의 미량정량)

  • Lee, Sun Haing;Kim, Kyoung Hee;Lee, Young Cheol;Kim, Sang Tae
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.4
    • /
    • pp.257-265
    • /
    • 1995
  • Free amino acids were isolated from milk and their absolute amounts were determined by reversed phase high performance liquid chromatography after derivatization with dansyl chloride. The determination of D- and L-amino acids was based on achiral separation on a C18 column. It was found that milk contained totally 41.00 mg DL-amino acids in 100 mL milk. The level of D-amino acids to L-amino acids was determined by a column-switching system combining an achiral reversed phase separation and chiral chelate additive. The chiral separation was carried out with addition of the chiral Cu(N-benzyl-L-proline)2 chelate to the mobile phase in reversed phase liquid chromatography. It was found that the determination of 16 different amino acids is feasible in the milk sample with a C18 column separation and 12 D-amino acids out of the 16 amino acids can be determined via the column-switching system with chiral separation. 2.05% of D-glutamic acid and 2.93% of D-alanine were found in milk.

  • PDF

Determination of methamphetamine and amphetamine enantiomers in human urine by chiral stationary phase liquid chromatography-tandem mass spectrometry

  • Sim, Yeong Eun;Ko, Beom Jun;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.163-172
    • /
    • 2019
  • Methamphetamine (MA) is currently the most abused illicit drug in Korea and its major metabolite is amphetamine (AP). As MA exist as two enantiomers with the different pharmacological properties, it is necessary to determine their respective amounts in a sample. Thus a chiral stationary phase liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of d-MA, l-MA, d-AP, and l-AP in human urine. Urine sample ($200{\mu}L$) was diluted with pure water and purified using solid-phase extraction (SPE) cartridge. A $5-{\mu}L$ aliquot of SPE treated sample solution was injected into LC-MS/MS system. Chiral separation was carried out on the Astec Chirobiotic V2 column with an isocratic elution for each enantiomer. Identification and quantification of enantiomeric MA and AP was performed using multiple reaction monitoring (MRM) detection mode. Linear regression with a $1/x^2$ as the weighting factor was applied to generate a calibration curve. The linear ranges were 25-1000 ng/mL for all compounds. The intra- and inter-day precisions were within 3.6 %, while the intra- and inter-day accuracies ranged from -5.4 % to 11.8 %. The limits of detection were 2.5 ng/mL (d-MA), 3.5 ng/mL (l-MA), 7.5 ng/mL (d-AP), and 7.5 ng/mL (l-AP). Method validation parameters such as selectivity, matrix effect, and stability were evaluated and met acceptance criteria. The applicability of the method was tested by the analysis of genuine forensic urine samples from drug abusers. d-MA is the most common compound found in urine and mainly used by abusers.

Preparative Chromatographic Separaction: Simulated Moving Bed and Modified Chromatography Methods

  • Yi Xie;Koo, Yoon-Mo;Nien-Hwa Linda Wang
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.6
    • /
    • pp.363-375
    • /
    • 2001
  • Chromatography has been method of choice for the separation complex biologi-cal mixtures fro analytical purpose, particularly for the last fifty years. Its use has recently been extended to preparative separation where the productivity relative to the amount of resin and sol-vent used is a matter of concern. To overcome the inherent thermodynamic inefficiency of batch chromatography, as exemplified by the partial temporal usage of the resin and dilution of the product with the solvent, chromatography has been continually modified by separation engineers. Column switching and recycling represnet some of the process modifications that have brought high productivity to chromatography. Recently, the simulated moving bed (SMB) method, which claims a high separation efficiency based on counter-current moving bed chromatography. has be-come the mainstay of preparative separation, especially in chiral separation. Accordingly, this pa-per reviews the current status of SMB along with several chromatographic modification, which may be helpful in routine laboratory and industrial chromatographic practices.

  • PDF

Separation of Amino Acid Enantiomers by Gas Chromatogaphy on Phenylthiohydantoin Derivatives as Chiral Stationary Phases (아미노산 Phenylthiohydantoin 유도체를 키랄 고정상으로 한 GC에 의한 아미노산 광학 이성질체의 상호분리)

  • Park, Man-Ki;Yang, Jeong-Seen;Ko, Chang-Bum;Lee, Mi-Yung
    • YAKHAK HOEJI
    • /
    • v.32 no.3
    • /
    • pp.170-176
    • /
    • 1988
  • The resolution of five amino acids derivatives by gas chromatography on phenylthiohydantoin derivatives as chiral stastionary phase was investigated. (S)-5-isopropyl, isobutyl, (sec)-butyl and benzoyl derivatives of $N^3-phenyl-2-thiohydantoin$ were synthesized from L-valine, L-leucine, L-isoleucine and L-phenylalanine, respectively. The phases were employed at several column temperatures ($140^{\circ}C{\sim}210^{\circ}C$). The separation factors were compared with each stationary phase with varying R groups. The possible mechanism of chiral recognition was investigated by NMR technique.

  • PDF

Simultaneous Enantiomer Separation of α-Amino Acids and Their Esters as Fluorenylmethoxycarbonyl Derivatives under UV and Fluorescence Detection by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에서 아미노산과 이들 에스테르의 플루오레닐메톡시카르보닐 유도체의 자외선과 형광 검출에서의 동시 광학분리)

  • Islam, Md. Fokhrul;Lee, Wonjae
    • KSBB Journal
    • /
    • v.30 no.4
    • /
    • pp.197-201
    • /
    • 2015
  • Liquid chromatographic enantiomer separation of ${\alpha}$-amino acids and their methyl and ethyl esters as fluorenylmethoxycarbonyl (FMOC) derivatives was performed using a recently developed chiral column (Chiralpak IE) based on polysaccharide derivative under simultaneous UV detection and fluorescence detection. The degree of enantiomer separation of ${\alpha}$-amino acid esters as FMOC derivatives is generally higher than that of the corresponding ${\alpha}$-amino acids. Especially, ${\alpha}$-amino acid methyl esters showed the greatest enantioseparation. As this method developed in this study can be applied to determine the chemical and optical purity of ${\alpha}$-amino acids and esters, it is expected to be quite useful for their chiral separation using Chiralpak IE.

Resolution of Tocainide and Its Analogues on Liquid Chromatographic Chiral Stationary Phases Based on (+)-(18-Crown-6)-2,3,11,12-tetracarboxylic Acid

  • Hyun, Myung-Ho;Min, Hye-Jung;Cho, Yoon-Jae
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.911-915
    • /
    • 2003
  • Two liquid chromatographic chiral stationary phases (CSPs) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid were successfully applied in the resolution of racemic tocainide and its analogues. In the resolution of tocainide, especially, the CSP containing N-CH₃ amide tethering groups was quite effective, showing clear baseline resolution (RS: 2.66) with reasonable enantioselectivity ( a: 1.25). Consequently, the CSP containing N-CH₃ amide tethering groups is expected to be useful to monitor the enantiomeric composition of tocainide in clinical samples. In addition, the chromatographic behaviors for the resolution of tocainide and its analogues on the two CSPs were found controllable by varying the content and the type of organic and acidic modifiers in aqueous mobile phase.