• Title/Summary/Keyword: chest image

Search Result 418, Processing Time 0.028 seconds

Automated Classification of Ground-glass Nodules using GGN-Net based on Intensity, Texture, and Shape-Enhanced Images in Chest CT Images (흉부 CT 영상에서 결절의 밝기값, 재질 및 형상 증강 영상 기반의 GGN-Net을 이용한 간유리음영 결절 자동 분류)

  • Byun, So Hyun;Jung, Julip;Hong, Helen;Song, Yong Sub;Kim, Hyungjin;Park, Chang Min
    • Journal of the Korea Computer Graphics Society
    • /
    • v.24 no.5
    • /
    • pp.31-39
    • /
    • 2018
  • In this paper, we propose an automated method for the ground-glass nodule(GGN) classification using GGN-Net based on intensity, texture, and shape-enhanced images in chest CT images. First, we propose the utilization of image that enhances the intensity, texture, and shape information so that the input image includes the presence and size information of the solid component in GGN. Second, we propose GGN-Net which integrates and trains feature maps obtained from various input images through multiple convolution modules on the internal network. To evaluate the classification accuracy of the proposed method, we used 90 pure GGNs, 38 part-solid GGNs less than 5mm with solid component, and 23 part-solid GGNs larger than 5mm with solid component. To evaluate the effect of input image, various input image set is composed and classification results were compared. The results showed that the proposed method using the composition of intensity, texture and shape-enhanced images showed the best result with 82.75% accuracy.

Enhancing Medical Images by New Fuzzy Membership Function Median Based Noise Detection and Filtering Technique

  • Elaiyaraja, G.;Kumaratharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2197-2204
    • /
    • 2015
  • In recent years, medical image diagnosis has growing significant momentous in the medicinal field. Brain and lung image of patient are distorted with salt and pepper noise is caused by moving the head and chest during scanning process of patients. Reconstruction of these images is a most significant field of diagnostic evaluation and is produced clearly through techniques such as linear or non-linear filtering. However, restored images are produced with smaller amount of noise reduction in the presence of huge magnitude of salt and pepper noises. To eliminate the high density of salt and pepper noises from the reproduction of images, a new efficient fuzzy based median filtering algorithm with a moderate elapsed time is proposed in this paper. Reproduction image results show enhanced performance for the proposed algorithm over other available noise reduction filtering techniques in terms of peak signal -to -noise ratio (PSNR), mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), image enhancement factor (IMF) and structural similarity (SSIM) value when tested on different medical images like magnetic resonance imaging (MRI) and computer tomography (CT) scan brain image and CT scan lung image. The introduced algorithm is switching filter that recognize the noise pixels and then corrects them by using median filter with fuzzy two-sided π- membership function for extracting the local information.

Phased Segmentation of Human Organs On the MDCT Scans (흉부 MDCT 영상을 이용한 신체 장기의 단계별 분할)

  • Shin, Min-Jun;Kim, Do-Yeon
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.11
    • /
    • pp.1383-1391
    • /
    • 2011
  • Following the appearance of the latest medical equipment with improved function, the importance of image analysis which enables effective image processing and analysis consistent with the hardware performance is on the rise. As well as, ongoing study is being done on the 2D medical image processing and 3D reconstruction. This paper segments chest CT images into each stage and finally shows 3D reconstruction of each segmented result. Among various image segmentation methods, Region Growing and apply sharpening and Gamma Controller as for image improvement for effective segmentation, image segmentation in order of bronchus and lung, bronchus, lung. Human organs image of segmented is use VTK(Visualization Toolkit) to make 3D reconstruction, two and three-dimensional medical image processing and analysis for lesions diagnosis are able to utilized.

Development of Medical Image Quality Assessment Tool Based on Chest X-ray (흉부 X-ray 기반 의료영상 품질평가 보조 도구 개발)

  • Gi-Hyeon Nam;Dong-Yeon Yoo;Yang-Gon Kim;Joo-Sung Sun;Jung-Won Lee
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.243-250
    • /
    • 2023
  • Chest X-ray is radiological examination for xeamining the lungs and haert, and is particularly widely used for diagnosing lung disease. Since the quality of these chest X-rays can affect the doctor's diagnosis, the process of evaluating the quality must necessarily go through. This process can involve the subjectivity of radiologists and is manual, so it takes a lot of time and csot. Therefore, in this paper, based on the chest X-ray quality assessment guidelines used in clinical settings, we propose a tool that automates the five quality assessments of artificial shadow, coverage, patient posture, inspiratory level, and permeability. The proposed tool reduces the time and cost required for quality judgment, and can be further utilized in the pre-processing process of selecting high-quality learning data for the development of a learning model for diagnosing chest lesions.

Automatic Segmentation of Lung, Airway and Pulmonary Vessels using Morphology Information and Advanced Rolling Ball Algorithm (형태학 정보와 개선된 롤링 볼 알고리즘을 이용한 폐, 기관지 및 폐혈관 자동 분할)

  • Cho, Joon-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.173-181
    • /
    • 2014
  • In this paper, the algorithm that can automatically segment the lung, the airway and the pulmonary vessels in a chest CT was proposed. The proposed method is progressed in three steps. In the first step, the lung and the airway are segmented by the region growing law through the optimal threshold and three-dimensional labeling. In the second, from the start point to the first carina of the airway is segmented by the deduction operation, and the next airway of the bifurcations are segmented by applying a variable threshold technique. In the third step, the left/right lungs are divided by the restoration process for the lung, and the outside of lungs for abnormal is checked by applying the advanced rolling ball algorithm, and if abnormal is found, that part is removed, and it is restored to the normal lungs by connecting the outside of the lung in the form of second-order polynomial. Finally, pulmonary vessels are segmented by applying the three-dimensional connected component labeling method and three-dimensional region growing method. As the results of simulation, it could be confirmed that the pulmonary vascular is accurately divided without loss of tissue around lung.

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

An Automatic Extraction of the Lung Region in X- Rays (흉부방사선 영상의 흉부영역 자동검출에 관한 연구)

  • 김용만;장국현
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.331-342
    • /
    • 1989
  • This paper presents a new algorithm that extracts lung region in X-Rays and enhance.j the region. Comparing to prior algorithms that enhance whole X-Ray image, this algorithm leads more effective results. For this algorithm extracts lung region first, and enhances the lung region excluding parameters of other region. For choosing optimal threshold, we compare OTSU's mothod with the proposed method. We obtain lung boundary using contour following algorithm and Rray level searching method in gray level rescaled image. We Process histogram equalization in lung region and obtain enhanced lung image. By using the proposed algorithm, we obtain lung region effectively in chest X-Ray that need in medical image diagnostic system.

  • PDF

EFFECTIVE DOSE MEASUREMENT FOR CONE BEAM COMPUTED TOMOGRAPHY USING GLASS DOSIMETER

  • Moon, Young Min;Kim, Hyo-Jin;Kwak, Dong Won;Kang, Yeong-Rok;Lee, Man Woo;Ro, Tae-Ik;Kim, Jeung Kee;Jeong, Dong Hyeok
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.255-262
    • /
    • 2014
  • During image-guided radiation therapy, the patient is exposed to unwanted radiation from imaging devices built into the medical LINAC. In the present study, the effective dose delivered to a patient from a cone beam computed tomography (CBCT) machine was measured. Absorbed doses in specific organs listed in ICRP Publication 103 were measured with glass dosimeters calibrated with kilovolt (kV) X-rays using a whole body physical phantom for typical radiotherapy sites, including the head and neck, chest, and pelvis. The effective dose per scan for the head and neck, chest, and pelvis were $3.37{\pm}0.29$, $7.36{\pm}0.33$, and $4.09{\pm}0.29$ mSv, respectively. The results highlight the importance of the compensation of treatment dose by managing imaging dose.

The Effect of Advanced Modeling Iterative Reconstruction(ADMIRE) on the Quality of CT Images : Non-contrast CT in Chest (고급 모델링 반복 재구성법(ADMIRE)이 CT 영상의 화질에 미 치는 영향: 흉부 비조영 CT에서)

  • Lee, SangHeon;Lee, HyoYeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.159-168
    • /
    • 2019
  • We examined the effect of Siemens ADMIRE (Advanced Modeled Iterative Reconstruction) on image quality by measuring changes in HU, noise, and SNR of background air, fat, muscle, and background signals on a chest CT scan. Experimental results show that as the ADMIRE Strength increases, the noise decreases and the signal increases, consequently the signal-to-noise ratio increases. ADMIRE can reduce noise by 28 ~ 61% compared to FBP, which is a conventional image reconstruction algorithm, and improves SNR by 16 ~ 100%.

Visual Evaluation of Rib Shadow and Lung Marking during High-voltage Chest Radiography (흉부 고관전압 촬영에 있어서의 늑골음영과 폐문리의 시각적 평가)

  • Choi, Kwon-Kyu;Lee, Chang-Yup;Shin, Dong-Sik;Kim, Chang-Nam;Choi, Ki-Young;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.99-105
    • /
    • 1992
  • Visual evaluation of rib shadow and lung marking during high voltage chest radiography. The Purpose of this study is to improvement of visual discrimination of pulmonary structures on the conventional chest radiogram. The author prepared an artificial lung using an acryl plate, 8 cm in thickness, which is nearly equivalent to human lung, and 0.6 cm thickness of an aluminum plate for an artificial rib, and 0.5 cm of an acryl plate as a pulmonary vessel as well. And they were used as objects for experimental radiograms. This study performed with gradual increasing densities of film bases in the sequences of densities of 0.6, 0.9, 1.1 and 1.3. We made two combinations of images after multiple and regular cuts, with width of 1 cm, of 4 radiograms at the above mentioned densities of film bases. One image consisted of alternative combination of radiograms taken at densities of 0.6 and 1.3, and the other did at 0.9 and 1.1. The latter image provided better visual perception of pulmonary structures than the former. Experimental radiograms were also taken with 60 kV and 120 kV respectively. After careful evaluation and comparison to images taken on varieties of different densities with combinations and kV, the author had a conclusion that it is advisable to use a high kV X-ray which makes rib shadow subtle, for better visual delineation of pulmonary structures behind ribcage, eventhough contrast of pulmonary structures are decreased at high kV radiogram.

  • PDF