• Title/Summary/Keyword: chemical pump

Search Result 195, Processing Time 0.026 seconds

A Direct Injection-mixing Total-flow-control Boom Sprayer System (주입식 총유량 자동제어방식 분관 방제기의 개발)

  • 구영모
    • Journal of Biosystems Engineering
    • /
    • v.21 no.2
    • /
    • pp.155-166
    • /
    • 1996
  • A direct injection sprayer was designed using the concepts of injection mixing and total flow control, flowrate-based system compensating for the variation of forwarding speed. A metered rate, proportionally to the actual diluent flow rate, of a tracer chemical was injected directly into the diluent stream. The injection of chemical may improve the precision and safety of chemical application process. The control system was evaluated for the variables of the control interval, tolerances and sensitivities of flow regulation valve and injection pump. Performance of the system was assessed as that the response time of flow rate, response time of injection rate, absolute steady state error, and the coefficient of variance(C.V.) of concentration were 8.5 and -0.53 seconds, 0.067 lpm(0.8%) and 3.15%, respectively, at optimal parameters of control interval of 1.0 sec, fast sensitivity of flow regulation valve, medium sensitivity of injection pump and medium tolerance of flow rate. Performance of the system can be improved by increasing the sensitivity of flow regulating valve and employing a high resolution velocimeter, such as Doppler radar.

  • PDF

A Study of Complex Distillation Arrangements Using Dividing Wall Columns for Improved Depropanizing, Debutanizing and Deisobutanizing Fractionation of NGL (천연가스액 중 프로판, 부탄, 이소-부탄의 개선된 분리회수를 위한 분리벽형 증류탑을 이용한 복합 증류배열에 관한 연구)

  • Nguyen, Van Duc Long;Jang, Sungkeun;Lee, Moonyong
    • Korean Chemical Engineering Research
    • /
    • v.51 no.2
    • /
    • pp.245-249
    • /
    • 2013
  • The depropanizing, debutanizing and deisobutanizing fractionation steps of processing natural gas liquids were improved through studying complex distillation arrangements, including the double dividing wall column arrangement (DDWC), the sequence including a dividing wall column (DWC) and a bottom DWC (BDWC), and the sequence including a DWC and a BDWC with top vapor recompression heat pump. These arrangements offer benefits by decreasing reboiler and condenser power consumption. Reducing the number of columns and their diameters can potentially reduce construction costs. The result also showed that operating cost could be reduced most significantly through novel combinations of internal and external heat integration: bottom dividing wall columns employing a top vapor recompression heat pump.

Research on the structure design of the LBE reactor coolant pump in the lead base heap

  • Lu, Yonggang;Zhu, Rongsheng;Fu, Qiang;Wang, Xiuli;An, Ce;Chen, Jing
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.546-555
    • /
    • 2019
  • Since the first nuclear reactor first critical, nuclear systems has gone through four generations of history, and the fourth generation nuclear system will be truly realized in the near future. The notions of SVBR and lead-bismuth eutectic alloy coolant put forward by Russia were well received by the international nuclear science community. Lead-bismuth eutectic alloy with the ability of the better neutron economy, the low melting point, the high boiling point, the chemical inertness to water and air and other features, which was considered the most promising coolant for the 4th generation nuclear reactors. This study mainly focuses on the structural design optimization of the 4th-generation reactor coolant pump, including analysis of external characteristics, inner flow, and transient characteristic. It was found that: the reactor coolant pump with a central symmetrical dual-outlet volute structure has better radial-direction balance, the pump without guide vane has better hydraulic performance, and the pump with guide vanes has worse torsional vibration and pressure pulsation. This study serves as experience accumulation and technical support for the development of the 4th generation nuclear energy system.

A Study on Expedite Heat Transfer in Packed Bed of Hydration Calcined Dolomite for Chemical Heat Pump (소성 Dolomite 수화물 화학열펌프의 고체반응층 전열촉진 연구)

  • Kim, Jong-Shik;Lee, Han-Gyu;Park, Young-Hae
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.434-439
    • /
    • 2005
  • The reaction of hydration proceeded at the same time the vapor was introduced into the reactor that was filled with calcined dolomite. It has shown that the temperature has begun to fall from the bottom of reactor after increase of temperature by the heat of hydration reaction. The reaction initiated at the pipe wall and the heat was transfer to the center of block between the fins. The results show that the use of copper fin in the reactor reducted the hydration reaction time by half when compared to the case without using the fins.

Evaluation of Safety Characteristic in Chemical Decontamination at Extremely Severe Condition of Stainless Steels for Coolant Pump (가장 가혹한 조건에서 화학 제염한 경우 냉각재 펌프용 스테인리스강의 안정성 평가)

  • Kim, Seong-Jong;Jang, Seok-Ki;Kim, Ki-Joon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.253-259
    • /
    • 2006
  • This paper investigated on anti-corrosion characteristic in chemical decontamination at extremely severe condition{process model-2) of stainless steels used with reactor coolant pump. The electrochemical properties of stainless steel{STS) 304 with the lapse qf cycle is better than those of STS 415 and STS 431. The STS 304 in process model-1 and process model-2 present the lowest weightloss ratio. The experiment results for STS 304, STS 415, and STS 431 in process model-2 solution, it was ascertained that weightloss ratio of process model-2 solution for process model-1 solution show 2..908, 2.572, and 2.370 times, respectively. The reason suggests that process model-2 is higher concentration of chemical and temperature compare to process model-1.

  • PDF

Evaluation of the Effect of Pump and Fertilize on Nitrate Reduction in Groundwater (지하수 관개 시비의 지하수 내 질산성질소 저감 효과 평가)

  • Yuhoon Yeum;Young Kim;Moon-su Kim;Sunhwa Park;Kyungjin Han
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.1
    • /
    • pp.18-27
    • /
    • 2024
  • In this study, the pump and fertilize (PAF) was applied to reduce nitrogen infiltration into groundwater at three corn cultivation sites over a three-year period, and its effectiveness was evaluated. PAF involves pumping nitrate-contaminated groundwater and using it for irrigation, thereby replacing the need for chemical fertilizers. This method not only substitutes chemical fertilization, but also reduces nitrogen infiltration into groundwater through root zone consumption. To confirm PAF's effectiveness, an equal amount of nitrogen was applied in each cultivation plot, either through chemical fertilizer or irrigation with nitrate-contaminated groundwater. Regular monitoring of infiltrating pore water and groundwater was conducted in each cultivation plot. The linear regression slope for nitrate concentration in the pore water after repeated application of PAF ranged from -3.527 to -8.3485 mg-N/L/yr, confirming that PAF can reduce nitrate concentration in the pore water. With an increasing proportion of PAF, the infiltrating nitrate mass in pore water was reduced by 42% compared to plots fertilized with chemical fertilizer. Additionally, the linear regression slope of nitrate concentration in groundwater was calculated as -2.2999 and -9.2456 mg-N/L/yr. Therefore, continuous application of PAF in rural areas is expected to significantly contribute to reducing nitrate concentration in groundwater.

A Comparative study on drinking Water quality of simple piped Water supply Systems and water Pumps. (일부 농촌 지역의 간이 상수도와 Pump수의 수질에 관한 비교 연구조사 -춘성군 지역을 중심으로-)

  • 정문호;송금순
    • Journal of Environmental Health Sciences
    • /
    • v.9 no.1
    • /
    • pp.77-84
    • /
    • 1983
  • A study was carried out to find drinking water qualities of 56 simple piped water supply systems and 37 water pumps in Chun Sung Conutry, Kang Won Province from 1st July to 30th August 1981. 1. The results of all kinds of water test are found to be safe at only one out of fifty six samples of simple piped water supply system at two out of thirty-seven samples of water pump and unsafe at the others. 2. In general Count of Bacteria test, twelve (21.4%) out of fifty six samples of the simple piped water are found to be safe for the legitimate standard of safty water, and five (13.5%) out of thirty=seven samples of pump water. 3. Escherichia coli group is negative at seven (12.5%) out of fifty-six samples of simple piped water, and eight (21.6%) out of thirty-seven samples of pump water. 4. The results of the physical and chemical examination of drinking water specimen are found to be safe at twelve out of fifty-six samples of simple piped water and at twenty-eight out of thirty-seven samples of pump water.

  • PDF

Thermal Property Evaluation of a Silicon Nitride Thin-Film Using the Dual-Wavelength Pump-Probe Technique (2파장 펌프-프로브 기법을 이용한 질화규소 박막의 열물성 평가)

  • Kim, Yun Young
    • Korean Journal of Materials Research
    • /
    • v.29 no.9
    • /
    • pp.547-552
    • /
    • 2019
  • In the present study, the thermal conductivity of a silicon nitride($Si_3N_4$) thin-film is evaluated using the dual-wavelength pump-probe technique. A 100-nm thick $Si_3N_4$ film is deposited on a silicon (100) wafer using the radio frequency plasma enhanced chemical vapor deposition technique and film structural characteristics are observed using the X-ray reflectivity technique. The film's thermal conductivity is measured using a pump-probe setup powered by a femtosecond laser system of which pump-beam wavelength is frequency-doubled using a beta barium borate crystal. A multilayer transient heat conduction equation is numerically solved to quantify the film property. A finite difference method based on the Crank-Nicolson scheme is employed for the computation so that the experimental data can be curve-fitted. Results show that the thermal conductivity value of the film is lower than that of its bulk status by an order of magnitude. This investigation offers an effective way to evaluate thermophysical properties of nanoscale ceramic and dielectric materials with high temporal and spatial resolutions.