• Title/Summary/Keyword: chemical ionization

Search Result 409, Processing Time 0.035 seconds

A Study on the Determination of Rare Earth Elements by Inductively Coupled Plasma Spectrometry (Inductively Coupled Plasma 법을 이용한 희토류원소의 분석에 관한 연구)

  • Beom Suk Choi;Sun Tae Kim;Young Man Kim;Chong Wook Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.4
    • /
    • pp.382-389
    • /
    • 1985
  • The effect of plasma operational parameters for the determination of rare earth elements(REE) by means of inductively coupled plasma(ICP) spectrometry was investigated. While the increase in the flow rate of carrier gas argon enhanced the sensitivity and lowered the detection limit, significant ionization interferences were observed. The decrease in RF power increased the signal to background ratio. The observation point showing the lowest ionization interference was slightly higher than the position where the spatial profile of the analyte reached the maximum. The detection limits of the spectral lines commonly used for the determination of REE were measured and the spectral lines relatively free from spectral interferences were chosen.

  • PDF

Characterization of Basic Nitrogen-Containing Compounds in the Products of Lube Base Oil Processing by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

  • Li, Xiaohui;Zhu, Jianhua;Wu, Bencheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.165-172
    • /
    • 2014
  • The distribution of basic nitrogen-containing compounds in three vacuum gas oils (VGOs) with different boiling ranges and their dewaxed oils from the lube base oil refining unit of a refinery were characterized by positive-ion electrospray ionization (ESI) Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS). It turned out that the composition of basic nitrogen compounds in the samples varied significantly in DBE and carbon number, and the dominant basic N-containing compounds in these oil samples were N1 class species. $N_1O_1$, $N_1O_2$, and $N_2$ class species with much lower relative abundance were also identified. The composition of basic nitrogen compounds in VGOs and dewaxed VGOs were correlated with increased boiling point and varied in DBE and carbon numbers. The comparison of the analytical results between VGOs and dewaxed VGOs indicated that more basic N-containing compounds in VGO with low carbon number and small molecular weight tend to be removed by solvent refining in lube base oil processing.

Sequence Verification of Synthetic Oligonucleotides by Exonuclease Digestion and Matrix Assisted Laser Desorption Ionization Mass Spectrometry

  • Kim, Jin-Sung;Jang, Jung-Suk;Choi, Jong-Soon;Chang, Yoon-Seok
    • BMB Reports
    • /
    • v.29 no.2
    • /
    • pp.122-126
    • /
    • 1996
  • A series of oligonucleotides were synthesized by automatic DNA synthesizer. The purity of crude products was checked and their molecular weights determined by matrix assisted laser desorption ionization mass spectrometry (MALDI-MS) with an accuracy of better than 0.05% deviation even without using an internal standard. This mass determining technology in combination with partial digestion of oligonucleotides by 5'- and 3'-exonuclease provides a straightforward and simple method to obtain sequence information of oligonucleotides. The extension of this technology to the sequencing of modified oligonucleotides and genomic DNA and RNA might become possible.

  • PDF

Sample Preparation for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

  • Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • v.6 no.2
    • /
    • pp.27-30
    • /
    • 2015
  • This article reviews the fundamentals of sample preparation used in matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). MALDI is a soft ionization method used to generate analyte ions in their intact forms, which are then detected in MS analysis. MALDI-MS boasts fast analysis times and easy-to-use operation. The disadvantages of MALDI-MS include the occurrence of matrix-associated peaks and inhomogeneous distribution of analyte within the matrix. To overcome the disadvantages of MALDI-MS, various efforts have been directed such as using different matrices, novel matrix systems, various additives, and different sample preparation methods. These various efforts will be discussed in detail. This article will benefit those who would like to obtain basic knowledge of MALDI sample preparation and those who would like to use MALDI-MS in their chemical analyses.

LC/ESI/MS 와 기능성 화장품 관련 분석에의 응용

  • 이명희
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.3
    • /
    • pp.23-46
    • /
    • 1999
  • LC/MS는 HPLC의 분리능과 질량분석기의 화합물의 확인 능력을 결합시킨 기기이다. 여기서 사용되는 이온화 방법은 GCJMS에서 사용되어지는 전자이온화법(electron ionization, EI)이나, 화학이온화법(chemical ionization, CI)은 부적당하기 때문에 최근 개발되어진 연성 이온화법의 대표적인 고속원자폭격식(Fast atom bombardment, FAB)이나 전기분무이온화식 (electrospray ionization, ESI) 등이 사용되고 있다. 이중 전기분무이온화법은 고속원자폭격법에서 사용되는 매트릭스를 사용하지 않기 때문에 매트릭스 이온의 부재로 인한 낮은 바탕 신호, 오래 지속되면서 안정된 초기 이온 전류, 샘플링의 용이성, HPLC와의 더 좋은 호환성 등의 장점을 제공한다. 이러한 전기분무이온화 방법은 극성이 매우 크거나 휘발성이 낮은 물질로 보통의 EI나 CI 이온화 방법으로 분석이 어려운 물질들을 분석할 수 있다. 또한 열에 불안정하거나 분자의 분자량이 다른 단백질 등의 분석도 가능하다. 이러한 LC/ESI/MS 방법을 이용하여 열에 불안정하고 극성이면서 분자량이 커서 GC/MS 펄의 분석이 어려운 기능성 화장품 원료로 주목받고 있고 생체에 존재하는 지질 성분으로 알려진 레시틴과 세라마이드의 분석이 가능함을 소개하고 분리와 동시에 그 분자량과 구조에 대한 정보를 빠르게 얻을 수 있음을 소개하였다.

  • PDF

Study on Photodegradable Water-Soluble Compounds of Expanded Polystyrene

  • Lee, Seulgidaun;Kim, Sunghwan
    • Mass Spectrometry Letters
    • /
    • v.12 no.3
    • /
    • pp.118-124
    • /
    • 2021
  • Many previous studies have focused on revealing the harmfulness of microplastic particles, whereas very few studies have focused on the effects of chemicals, particularly photooxidation product. In this study, products of photodegradation from expanded polystyrene (EPS), compounds produced by photolysis by ultraviolet (UV) light, were investigated. EPS was directly irradiated and photolyzed using a UV lamp, and then the extracted sample was analyzed using high-resolution mass spectrometry (HRMS). Multiple ionization techniques, including electrospray ionization, atmospheric pressure chemical ionization, and atmospheric pressure photoionization, were used. In total, >300 compounds were observed, among which polystyrene monomer, dimer, and oxidized products were observed. In this work, the data presented clearly demonstrate that it is necessary to identify and monitor oxidized plastic compounds and assess their effect on the environment.

Preparation of Calcium Powder from Eggshell and Use of Organic Acids for Enhancement of Calcium Ionization (난각칼슘의 제조 조건 및 유기산이 칼슘의 이온화에 미치는 영향)

  • Shin, Hyung-Soon;Kim, Kong-Hwan
    • Applied Biological Chemistry
    • /
    • v.40 no.6
    • /
    • pp.531-535
    • /
    • 1997
  • An efficient process for recovery of calcium from the eggshell was developed and some organic acids were used in an attempt to enhance the degree of calcium ionization. Eggshell membrane was readily separated from crushed eggshell based on the differences in specific gravities. The conditions which allowed most efficient membrane removal were found to be 30 rpm of speed, 30 min of residence time and 0.08 of volume fraction. It took 3 hours for the eggshell powder prepared at $1000^{\circ}C$ to reach L value of 90 with the Hausner ratio being 1.43. The calcium ion concentrations were 990, 3500, 3900 and 4200 ppm in pure water, acetic acid, citric acid and lactic acid$(0.05{\sim}3%)$ aqueous solution, respectively. The degrees of ionization of calcium-citrate-malate complex(CCM), calcium-citric acid complex(CC) and calcium malic acid complex(CM) increased by 4 to 5 times compared to eggshell calcium powder.

  • PDF