• Title/Summary/Keyword: chemical indicator

Search Result 331, Processing Time 0.028 seconds

The Study of Donor-Acceptor Chromophores and Diketopyrrolopyrrole(DPP) Analogues (Donor-Acceptor 발색단과 디케토피롤로피롤(DPP) 유도체에 관한 연구)

  • Kim, HunSoo;Kim, SeungHoi;Park, SooYoul
    • Tribology and Lubricants
    • /
    • v.32 no.5
    • /
    • pp.141-146
    • /
    • 2016
  • The diketopyrrolopyrrole (DPP) pigment is a bicyclic 8-π-electron system containing two lactam units. Typical DPP derivative pigments have melting points of over 350°C and very low solubility in most solvents, and show absorption in the visible region with a molar extinction coefficient of 33,000 dm2mol−1 and strong photoluminescence with maxima in the range 500–600 nm. X-ray structure analyses of DPP show that the whole molecule is almost in one plane. The phenyl rings are twisted out of the heterocyclic plane and the intermolecular hydrogen bonding between neighboring lactam NH and carbonyl units influences the structure of the DPP pigment in the solid state. In this study, mono-N-alkylation and mono-N-arylation were undertaken for Pigment Red 264 or Pigment Orange 73 with alkyl halide and aryl halide, respectively, in the presence of sodium tert-butoxide as a base catalyst to improve the solubility of DPP pigments and their application as CO2 indicators. The synthetic yield was in the range 11–88%. The indicator dyes are highly soluble in organic solvents and shows pH-dependent absorption (λmax 501 and 572 nm for the protonated and deprotonated forms, respectively) and emission (λmax 524 and 605 nm for the protonated and deprotonated forms, respectively) spectra. The mono-N-alkylated and mono-N-arylated DPP pigment was identified by 1H-NMR (1H-Nuclear Magnetic Resonance Spectrometer), FT-IR (Fourier Transform Infrared Spectroscopy), and MS (Mass Spectrometry). According to the results of color and hue properties obtained by a color matching analyzer, the synthesized DPP pigment material can be used as a CO2 indicator.

The Efficacy of Water Purification and Distribution of Ammonia Oxidizing Bacteria in Shihwa Constructed Wetland (시화호 인공습지의 수질정화 및 암모니아 산화균의 분포 연구)

  • Kim, Seiyoon;Kim, Misoon;Lee, Sunghee;Lim, Miyoung;Lee, Youngmin;Kim, Zhiyeol;Ko, GwangPyo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.10-18
    • /
    • 2010
  • Water quality and the distribution of ammonia oxidizing bacteria were characterized in constructed wetland of Shihwa lake. Both physico-chemical parameters and fecal indicator microorganisms including total coliforms, E.coli, Enterococcus spp. were measured. In addition, denaturant gradient gel electrophoresis (DGGE) was carried out after PCR amplification of amoA gene from input, output, and wetland sites of the Banwol, Donghwa, and Samhwa stream in Shihwa lake area. Physico-chemical parameters were in proper range for typical nitrifying bacteria to grow and perform their biological activities. Average concentrations of fecal indicator microorganisms of wetland samples were lower than those of input sites. These results suggested that microbial water quality improved by the process of constructed wetland. According to phylogenetic information obtained from DGGE from study sites, distribution of nitrifying bacteria from each of input, output, and wetland were generally distinctive one another. In addition, distribution of nitrifying bacteria between Banwol and Donghwa streams showed higher similarity (52.6%) than this of Samhwa stream (15.2%). These results indicated that characteristics of ammonia oxidizing bacteria in Samhwa were unique in comparison with those of Banwol and Donghwa stream.

Evaluation of the Possibility of Developing Organic Matter Indicators in Coastal Environments: Utilization of Dissolved Organic Carbon and Fluorescent Dissolved Organic Matter (연안환경에서 유기물 지표 개발을 위한 가능성 평가: 용존유기탄소와 형광용존유기물질 활용)

  • Lee, Min-Young;Yang, Kyungsun;Kim, Sunchan;Kim, Tae-Hoon
    • Ocean and Polar Research
    • /
    • v.43 no.2
    • /
    • pp.65-72
    • /
    • 2021
  • In order to evaluate the dissolved organic carbon (DOC) and fluorescent dissolved organic matter (FDOM), as indicators of organic matter in the coastal environments, we measured the concentrations of DOC, FDOM, and chemical oxygen demand (COD) in saline groundwater (Woljeong, Pyoseon, and Hwasun beaches) and coastal seawater (Haengwon, Gwideok, Pyoseon, and Yeongnak) in Jeju, Korea. The highest concentrations of DOC and COD in groundwater were found in Woljeong and Pyoseon, and those in coastal water were observed in Haengwon and Pyoseon, indicating that the higher concentrations of DOC and COD seem to be associated with saline groundwater-driven dissolved organic matter (DOM) and/or biogeochemical processes. According to origin and optical properties of DOM using FDOM as a tracer, proportion of humic-like FDOM, more refractory DOM, was relatively greater in the groundwater than in the coastal water. With regard to this result, there was no relationship between DOC and COD in groundwater, while DOC showed a good positive correlation (r2 = 0.66) with COD in coastal water. This result indicates that COD as an indicator of assessment of DOM has a limitation in which it is difficult to quantify refractory DOM. Although DOC is a potential alternative to COD in the coastal environments, particulate organic carbon cannot be negligible due to relatively higher concentration compared to the open ocean. Therefore, the use of total organic carbon (TOC) as a replacement of COD in the coastal ocean is important, and the evaluation criterion of the TOC is necessary in order to evaluate of organic matter indicator in the various coastal environments.

Reliable Continuous Object Detection Scheme in Wireless Sensor Networks (무선 센서 네트워크에서 신뢰성 있는 연속 개체 탐지 방안)

  • Nam, Ki-Dong;Park, Ho-Sung;Yim, Young-Bin;Oh, Seung-Min;Kim, Sang-Ha
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12A
    • /
    • pp.1171-1180
    • /
    • 2010
  • In wireless sensor networks, reliable event detection is one of the most important research issues. For the reliable event detection, previous works usually assume the events are only individual objects such as tanks and soldiers. Recently, many researches focus on detection of continuous objects such as wild fire and bio-chemical material, but they merely aim at methods to reduce communication costs. Hence, we propose a reliable continuous object detection scheme. However, it might not be trivial. Unlike individual objects that could be referred as a point, a continuous object is shown in a dynamic two-dimensional diagram since it may cover a wide area and it could dynamically alter its own shape according to physical environments, e.g. geographical conditions, wind, and so on. Hence, the continuous object detection reliability can not be estimated by the indicator for individual objects. This paper newly defines the reliability indicator for continuous object detection and proposes an error recovery mechanism relying on the estimation result from the new indicator.

Portable titrator equipped spectroscopic detectors; Spectrator (분광학적 검출기가 내장된 휴대용 적정기: 스펙트레이터)

  • Shin, Jiwon;Chae, Gyoyoon;Kim, Yeajin;Kim, Sangho;Chae, Yoonsu;Chae, Won-Seok
    • Analytical Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • During titration, several chemical reactions result in changes not only in the potential of chemicals, but also in the colors of the indicator. In a potentiometric titration, a titration curve is obtained by measuring the abrupt change in the potential at the endpoint. Generally, acid-base titration is performed by observing the color change caused by an indicator to determine the endpoint. The method of determining the endpoint by measuring the potential difference has been well established and commercialized; however, the devices that can obtain the endpoint by observing the color change are limited. Consequently, in this study, a simple and precise spectral endpoint detector was manufactured using a drop-counter comprising an infrared emitter and a phototransistor, a white light LED as the light source and photodetector, and an analog-to-digital converter (Arduino). Spectrator, a new named, showed excellent results in terms of the reproducibility of acid-base titration using thymol blue as an indicator. Herein, we present the results of the Spectrator-manufacturing process as well as the experimental results.

Occurrence of Cryptosporidium and Giardia and the Relationship between Protozoa and Water Quality Indicators in Swimming Pools

  • Xiao, Shumin;Yin, Pengna;Zhang, Yan;Hu, Sike
    • Parasites, Hosts and Diseases
    • /
    • v.55 no.2
    • /
    • pp.129-135
    • /
    • 2017
  • A total of 60 samples were collected from 35 swimming pools in Beijing, China, and the presence of Cryptosporidium and Giardia were investigated. The results showed that 16.7% and 15.0% of samples were positive for Cryptosporidium oocyst and Giardia cysts, respectively, with a mean concentration of 0.30 oocysts/10 L and 0.27 cysts/10 L. The oocysts and cysts were found to have higher rates of occurrence in August than in May. Genotyping confirmed the presence of Cryptosporidium hominis, C. parvum, and Giardia assemblages A and B, all of which were associated with human infections. The predominant species/assemblages were C. hominis and Giardia assemblage A. Analyses of the relationships between parasite oocysts/cysts, indicator bacteria, and physical-chemical parameters revealed that there was no correlation between 2 parasites and fecal bacterial indicators, whilst there was a significant correlation between protozoa and urea concentration, which indicates that urea concentration rather than fecal bacterial indicators might be an appropriate index for chlorine-resistant protozoa in swimming pools. This study provides useful information to improve the safety of swimming pool water and deduce the risk of protozoan infections.

Fabrication and Evaluation of Active Drug Delivery System Using Polypyrrole (폴리피롤을 이용한 능동형 약물전달시스템의 제작 및 평가)

  • Lee, Sang-Jo;Lee, Seung-Ki;Pak, James Jung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.47-55
    • /
    • 2004
  • This paper presents drug release properties of active drug delivery system (DDS) using volume change of polypyrrole (PPy). The incorporation of various chemical substances into the PPy and controlling its release with the externally applied voltage to the PPy are possible. In order to confirm possibility for drug delivery system qualitatively, indicator(phenol red) was examined as a dopant of PPy. The applied voltage to the PPy electrode was set to -2 V and this negative voltage makes the anionic indicator released in saline solution. After qualitative analysis, in order to confirm quantitative drug release characteristic of PPy, salicylate which is one of the aspirin substance was used as a dopant of PPy. As a result, the salicylate release characteristics with time was thoroughly investigated while varying the electrode area, polymerization time, the applied voltage for drug release. Based on these quantitative results, a preliminary experiment was carried out to check the feasibility of the PPy applicable to the neuronal system.

Measurement of Incident-reporting Rate for Developing a Leading Indicator of Safety Culture (안전문화 선행지표 개발을 위한 사건보고율 측정)

  • Kim, Beom Soo;Jin, Sangeun;Chang, Seong Rok
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.93-101
    • /
    • 2018
  • Various leading indicators of safety culture have been advocated for proactive actions as lagging indicators have limitations in reflecting the attitudes and behaviors due to their reactivity and low sensitivity. This study proposes a model of incident-reporting culture (IRC) and determines the influence of the components on incident-reporting rate (IRR) in order to develop proactive indicators of safety culture. A questionnaire survey was administered to 614 workers at a chemical company in Korea, and the internal psychological aspects were explored by using perceptions, attitude, and backgrounds. The relationship between these factors and IRR was quantitatively confirmed. The workers are more reluctant to report injury than property damage, the perception of severity is the most influencing factor, and most property damages are reported regardless of worker's willingness. These features should be prioritized when improving IRC, and the criteria of IRC need to be aligned with safety culture.

Evaluation Methods of Weathering Degree for Korean Decomposed Granite Soils (국내 화강풍화토 지반의 풍화도 평가방법)

  • 박병기;이광찬
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.127-140
    • /
    • 1999
  • In this study, decomposed granite soil samples were taken from 16 different regions and their weathering properties were investigated by testing their physical and chemical properties. According to the results, the Chemical Weathering Index (CWI) ranges from 15.5 to 30 in general and 12 out of the 16 regions show over 20 in CWI. The 12 regions are categorized into complete granite soil areas by Sueoka's classification. CWI, Li. $SiO_2,\; \DeltaS/S$ and SAR are all correlated significantly and used as indicators by which the degree of weathering can be judged. The degree of weathering can be measured especially through Li or $SiO_2$ which is considered as an easy approach of geotechnical classification. Also, the relationship between the value of N and Li is regarded as a good indicator in estimating the degree of weathering.

  • PDF

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.