• 제목/요약/키워드: chemical indicator

검색결과 329건 처리시간 0.027초

2,5-Dimercapto-1,3,4-thiadiazole에 의한 구리의 전위차 적정 정량 (Potentiometric Determination of Copper with 2,5-Dimercapto-1,3,4-thiadiazole)

  • 하영구
    • 대한화학회지
    • /
    • 제20권4호
    • /
    • pp.277-279
    • /
    • 1976
  • 은 전극을 지시전극으로 하고 표준칼로멜 전극을 기준전극으로 하여 전압플로위회로를 이용하여 수용액에서 2,5-dimercapto-1,3,4-thiadiazole에 의한 구리의 전위차 적정법을 연구하였다. 이 시약은 구리의 전위차 적정 정량에 뛰어나게 이용할 수 있었고 여러가지 가리움제를 사용하여 다른 이온들의 존재하에 대기중에서 미량의 구리를 직접 적정할 수 있었다.

  • PDF

Activation of Phospholipase D in Rat Thymocytes by Sphingosine

  • Lee, Young-kyun;Choi, Myung-Un
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권10호
    • /
    • pp.1451-1489
    • /
    • 2002
  • Sphingosine is known to regulate a wide range of cell physiology including growth, differentiation, and apoptosis. In this study, we examined the effect of sphingosine on the phospholipase D (PLD) activity in rat thymocytes. Sphingosine potently stimulated PLD in the absence of extracellular calcium, while depletion of intracellular calcium by BAPTA/AM treatment completely blocked activation of PLD by sphingosine. Sphingosine-induced increase of the intracellular calcium concentration was confirmed using a fluorescent calcium indicator Fluo-3/AM. A phosphoinositide-specific phospholipase C inhibitor U73122 partially inhibited the stimulation of PLD by sphingosine. When mouse PLD2 gene was transfected into mouse thymoma EL4 cells, which lack intrinsic PLD activity, sphingosine could stimulate PLD2 significantly while overexpression of human PLD1 had no effect. Taken together, the sphingosine-stimulated PLD activity in rat thymocytes is dependent on the mobilization of intracellular calcium and appears to be due to the PLD2 isoform.

Titanium Acetylacetonate as an Excellent Ion-Carrier in Construction of Iodide Sensor

  • Ganjali, Mohammad Reza;Daftari, Azadeh;Mizani, Farhang;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권1호
    • /
    • pp.23-26
    • /
    • 2003
  • Titanium acetylacetonate was used in the construction of a PVC-based membrane electrode. This sensor shows very good selectivity for iodide ion over a wide variety of common inorganic and organic anions. It exhibits Nernstian behavior with a slope of 59.1 mV per decade. The working concentration ranges of the sensor are with a detection limit of $3.0\;{\times}\;10^{-6}\;M$. The response time of the sensor is very fast (<8 s), and can be used for at least twelve weeks in the pH range of 4.0-9.2. The best performance was obtained with a membrane composition of 30% PVC, 65% dibutylphthalate, 3% titanium acetylacetonate and 2% hexadecyltrimethylammonium bromide. The proposed sensor was successfully applied as an indicator electrode for titration of iodide with silver ion.

Anionic Indicators on the Surface of Submicrospheres Consisting of Ionic Palladium(II) Complex

  • Kim, Cho-Rong;Noh, Tae-Hwan;Yoo, Kyung-Ho;Yoo, Bok-Ryul;Jung, Ok-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권12호
    • /
    • pp.3057-3060
    • /
    • 2009
  • Ionic palladium(II) complex, [($Me_4en)Pd(L)]_2(ClO_4)_4\;(Me_4$en = N,N,N',N'-tetramethylethylenediamine; L = bis-(4-(4-pyridylcarboxyl)phenyl)methane), allows to form a monodisperse submicrosphere without any template or additive. Surface-perchlorates on the submicrosphere have been exchanged by anionic pH indicators such as thymol blue, bromothymol blue, and bromocresol green. The ionic and amphiphilic properties of the palladium(II) complex appear to be primarily associated with the formation and easy surface-anion exchange of submicrosphere. The surface-anion exchange through the electrostatic interaction is a very good tool for the surface-modification. The color of the pH indicator-exchanged submicrospheres is very sensitive to pH and Hg$^{2+}$ cation, and thus they are promising to submicrospherical indicators.

EDTA 適定에 依한 닉켈 定量 (Determination of Nickel by EDTA Titration)

  • 김황암;김영태
    • 대한화학회지
    • /
    • 제5권1호
    • /
    • pp.76-79
    • /
    • 1961
  • The nickel has been separated and precipitated with dimethylglyoxime in the usual manner and dissolved the precipitates with hydrochloric acid. To the nickel solution, 0.2g of Murexide as an indicator and 5 ml of 20 percent tri-ethanol amine solution were added and titrated with a standard solution of EDTA. At the end point the color changes from yellow to deep purple. In this paper, the purpose is that conditions for titration and for separation from the interfering substances were investigated and a suitable procedure was found and applied on the determination of nickel in Korean nickel ores.

  • PDF

대사에너지 측정방법에 대한 최근 연구동향 (Recent Development for the Determination of Metabolizable Energy Values)

  • 한인규;오상집;송만강
    • 한국가금학회지
    • /
    • 제7권2호
    • /
    • pp.4-17
    • /
    • 1980
  • This is to review from the existing literatures the various methods of determination, problems involved in the determination of metabolizable energy(ME) values of poultry feedstuffs that is the most widely used energy term in poultry nutrition. An attempt will also be made to introduce the newly developed determination method of ME by Sibbald and his associates. It was found that conventional methods of ME measurements such as total collection method and indicator method require a great deal of labor and time. It should also be pointed out that these methods have some technical problems as well. Experimental evidences indicate that the ME content of feedstuffs may be affected by breed, age, substitution level of basal diet, kind of basal diet, methods of chemical analysis and chemical composition of experimental diet. Standard procedures and technical advantages of newly developed method of "True Metabolizable Energy" system are fully described.

  • PDF

Ferricyanide-Sensing Electrodes

  • Ihn, Gwon-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • 제7권1호
    • /
    • pp.36-38
    • /
    • 1986
  • The Ferricyanide-sensing electrodes were prepared with $Ag_2S\;and\;Ag_3Fe(CN)_6$ (mole ratio 3:1-7:1). The 5:1 $(Ag_2S:Ag_3Fe(CN)_6)$ composition is superior to others in terms of potentiometric response, rapidity of response and reproducibility. Testing was done over the concentration range $10^{-1}M{\sim}10^{-6}M\; Fe(CN)_6^{3-}$ at pH 6.8 with constant ionic strength. The concentration-potential curve was linear and coincided with the Nernstian slope (19.7 mV/decade). Interfering ions were $I^-,\;Br^-,\; SCN^-\;and\;Fe(CN)_6^{4-}$ and the life time of this electrode was 3 weeks. This electrode could be used as the indicator electrode for measuring the ferricyanide and ferrocyanide.

Thallium(I)-Selective Electrodes Based on Calix[4]pyrroles

  • 박경순;정성욱;이심성;김재상
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권9호
    • /
    • pp.909-912
    • /
    • 2000
  • Thallium(I) selective electrodes based on meso-alkyl substituted calix[4]pyrroles such as, meso-octamethyl-calix[4]pyrrole (L1), meso-octaethylcalix[4]pyrrole (L2) and meso-tetraspirocyclohexylcalix[4]pyrrole (L3) as sensor molecules have been pre pared and tested. The conditioned electrode (E4) incorporating L3gave best results with a wide working concentration range of 10-5.5 ~10-1 M near-Nernstian slope of 56.0 mV/decade of activity and detection limit of 10-6.0 M. This electrode exhibited a fast response time of 30 s and high selectivity over Na+ , K+ and other metal ions with only Ag+ interfering. The electrode works well in the pH range 2.0-11.0 and can be successfully employed for the determination of Tl+.This proposed electrode was also used as an indicator electrode in potentiometric titration of Tl+.

무선 센서 네트워크에서 신뢰성 있는 연속 개체 탐지 방안 (Reliable Continuous Object Detection Scheme in Wireless Sensor Networks)

  • 남기동;박호성;임용빈;오승민;김상하
    • 한국통신학회논문지
    • /
    • 제35권12A호
    • /
    • pp.1171-1180
    • /
    • 2010
  • 무선 센서 네트워크에서 신뢰성 있는 이벤트 탐지는 중요한 연구 주제들 중 하나이다. 신뢰성 있는 이벤트 탐지를 위한 기존 연구들은 탐지 대상인 이벤트를 탱크 혹은 군인과 같은 개별적인 개체로 가정했다. 최근 많은 연구들이 화재 혹은 생화학물질과 같은 연속적인 개체의 탐지에 관심을 까지게 되었지만, 단지 통신비용의 절감에 집중하고 있기 때문에 신뢰성에 대한 고려는 부족하다. 따라서 우리는 신뢰성 있는 연속 개체 탐지 방안을 제안 하고자 한다. 신뢰성 있는 연속 개체 탐지는 단순한 연구 주제가 아니다. 하나의 점으로 나타낼 수 있는 개별 개체와는 달리, 넓은 영역을 포함하며 지리적 조건이나 바람 같은 물리적 환경에 의해 형태가 변할 수 있는 연속 개체는 유동적인 2차원 도형으로 표현되기 때문이다. 따라서 개별 개체 탐지의 신뢰성을 측정하기 위해 사용되었던 신뢰성 지표로는 연속 개체 탐지의 신뢰성을 측정할 수 없다. 본 논문에서는 연속 개체 탐지에 적절한 신뢰성 지표를 새롭게 정의하고, 새로운 신뢰성 지표를 사용한 신뢰성 측정 결과를 통해 연속 개체 탐지의 오류를 복구하는 방안을 제안한다.

분광학적 검출기가 내장된 휴대용 적정기: 스펙트레이터 (Portable titrator equipped spectroscopic detectors; Spectrator)

  • 신지원;채교윤;김예진;김상호;채윤수;채원석
    • 분석과학
    • /
    • 제34권3호
    • /
    • pp.128-133
    • /
    • 2021
  • 적정 화학반응에는 화학종의 전위차 변화뿐만 아니라 지시약의 색깔 변화도 포함된다. 전위차 적정에서는 종말점에서 전위의 급격한 변화를 측정하여 적정 곡선을 얻는다. 산-염기 적정은 일반적으로 지시약의 색 변화를 관찰하여 종말점을 결정함으로써 수행된다. 전위차를 측정하여 종말점을 결정하는 방법은 잘 확립 되어 상용화되어 있지만 색의 변화를 관찰하여 종말점을 얻는 장치는 많지 않은 실정이다. 적외선 광원과 감지기로 적정액 방울을 계수하고, 백색광원과 광 검출기로 종말점의 변색을 감지하여 아날로그-디지털 변환기인 아두이노 (Arduino)가 적용된 간단하고 정밀한 스펙트럼 종말점 검출 기구를 제작하였다. Spectrator는 지시약으로 티몰 블루를 사용한 산-염기 적정에서 재현성 측면에서 우수한 결과를 보였다. Spectrator 제작 과정과 이를 사용한 실험결과를 공유한다.