• Title/Summary/Keyword: charging-discharging

Search Result 466, Processing Time 0.025 seconds

A Study on the Power Generation Performance Evaluation of the Alternator for the Vehicle (자동차용 발전기의 발전 성능 평가에 관한 연구)

  • Ahn, Hyun-Jin;Shim, Kwan-Shik;Lim, Young-Cheol;Choi, Jun-Ho;Park, Sung-Jun;Kim, Eui-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.21-29
    • /
    • 2014
  • In this paper examine the characteristics of the generator supplying the most significant electrical energy in some parts required to drive the vehicle, and it is focused on to fabricate a performance evaluation unit for developing alternator with better performance. Through performance tests in accordance with the electrical load of alternators that is made in Valeo Corp. and Denso Corp., which are currently applied by H Corp., the fabricated performance evaluation unit has measured the power generation amount of the electrical energy supplied from the alternator, and it was analyzed. On the basis of this result, and to understand the flow of electrical energy of the vehicle, furthermore, it is intended to verify the usefulness of the performance evaluation unit which is designed in this paper. In this paper, based on the mechanism of the proposed performance evaluation unit, it will try to learn the convergence technology that can be applied to the design of the performance evaluation unit of other components of the vehicle.

The Carrier-based PWM Method for Voltage Balance of Flying Capacitor Multi-bevel Inverter (플라잉 커패시터 멀티-레벨 인버터의 커패시터 전압 균형을 위한 캐리어 비교방식의 펄스폭변조기법)

  • 이상길;강대욱;이요한;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.65-73
    • /
    • 2002
  • This paper proposes a new carrier-based PWM method to solve the most serious problem of flying capacitor multi-level inverter that is the unbalance of capacitor voltages. The voltage unbalance occurs due to the difference of each capacitor's charging and discharging time applied to Flying Capacitor Inverter. New solution controls the variation of capacitor voltages into the mean '0'during some period by means of new carriers using the leg voltage redundancy in the flying capacitor inverter. The solution can be easily expanded to the multi-level inverter. The leg voltage redundancy in the new method makes the switching loss of device equals to the conduction loss of device. This paper will examine the unbalance of capacitor voltage and the conventional theory of self-balance using Phase-shifted carrier. And then the new method that is suitable to the flying capacitor inverter will be explained.

Development of Model Based Battery SOC Indicator for Electric Vehicle (모델기반의 전기자동차용 전지 잔존용량계 개발)

  • Lim, Y.C.;Park, J.G.;Ryoo, Y,J.;Lee, H.S.;Byun, S.C.;Kim, E.S.
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.35-42
    • /
    • 1996
  • In this paper, a development of model based battery SOC indicator is described. The proposed method is independent upon initial SOC, is reliable on the sudden change of load, and could estimate the available driving distance. The mathematical model of battery which has relation of the current, voltage and SOC estimates the SOC by least square estimation to minimize the error between measured voltage and estimated voltage. For experiment, the charging and discharging system using computer was designed to acquire the current and voltage data for model. The feasibility in electric vehicle was confirmed by variable load testing using the developed SOC indicator by stand-alone type microcontroller.

  • PDF

The Electric Characteristics of Asymmetric Hybrid Supercapacitor Modules with Li4Ti5O11 Electrode (Li4Ti5O11 전극을 이용한 비대칭 하이브리드 슈퍼커패시터 전기적 모듈 특성)

  • Maeng, Ju-Cheul;Yoon, Jung-Rag
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.357-362
    • /
    • 2017
  • Among the lithium metal oxides for asymmetric hybrid supercapacitor, $Li_4Ti_5O_{12}(LTO)$ is an emerging electrode material as zero-stain material in volume change during the with the charging and discharging processes. The pulverized LTO powder was observed to show the enhanced capacity from 120 mAh/g to 156 mAh/g at C-rate (10, 100 C). Hybrid supercapacitor module(48V, 416F) was fabricated using an asymmetric hybrid capacitor with a capacitance of 7500F. As a result of the measurement of C-rate characteristics, the module shows that the discharge time is drastically reduced at more than 50C, and the ESR and voltage drop characteristics are increased. The energy density and power density were reduced under high C-rate conditions. When designing asymmetric hybrid supercapacitor module, the C-rate and ESR should be considered As a result of measuring the 5 kw UPS, it was discharged at the current of 116A~170A during the discharge in the voltage range of 48V~30V, and the compensation time at discharge was measured to be about 33.2s. Experimental results show that it can be applied to applications related to stabilization of power quality by applying hybrid supercapacitor module.

Mechanical and Thermal Characteristics of Cement-Based Composite for Solar Thermal Energy Storage System (태양열 에너지 저장시스템 적용을 위한 시멘트 기반 복합재료의 역학 및 열적 특성)

  • Yang, In-Hwan;Kim, Kyoung-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.9-18
    • /
    • 2016
  • The thermal and mechanical properties of fiber-reinforced cement-based composite for solar thermal energy storage were investigated in this paper. The effect of the addition of different cement-based materials to Ordinary Portland cement on the thermal and mechanical characteristics of fiber-reinforced composite was investigated. Experiments were performed to measure mechanical properties including compressive strength before and after thermal cycling and split tensile strength, and to measure thermal properties including thermal conductivity and specific heat. Test results showed that the residual compressive strength of mixtures with OPC and slag was greatest among cement-based composite. Thermal conductivity of mixtures including graphite was greater than that of any other mixtures, indicating favor of graphite for improving thermal transfer in terms of charging and discharging in thermal energy storage system. The addition of CSA or zirconium increased specific heat of fiber-reinforced cement-based composite. Test results of this study could be actually used for the design of thermal energy storage system in concentrating solar power plants.

Leaching of Cathodic Active Materials from Spent Lithium Ion Battery (폐리튬이온전지로부터 분리한 양극활물질의 침출)

  • 이철경;김태현
    • Resources Recycling
    • /
    • v.9 no.4
    • /
    • pp.37-43
    • /
    • 2000
  • Leaching of $LiCoO_2$ as a cathodic active materials for recovering Li and Co from spent lithium ion battery was investigated in terms of reaction variables. At the optimum condition determined in the previous work, Li and Co in a $H_2SO_4$ and $HNO_3$ solution were dissolved 70~80% and 40%, respectively. Li and Co were leached over 95% with the addition of a reductant such as $Na_2S_2O_3$ or $H_2O_2$. This behavior is probably due to the reduction of $Co^{3+}$ to $Co^{2+}$. Leaching of $LiCoCo_2$ powder obtained by calcination of an electrode materials from spent batteries was also carried out. Leaching efficiency of Li and Co were over 99% at the optimum condition with $H_2O_2$ addition of 1.7 vol.%. It seems to be due to the activation of $LiCoO_2$ by repeated charging and discharging or an imperfect crystal structure by deintercalation of Li.

  • PDF

Determination of the Hybrid Energy Storage Capacity for Wind Farm Output Compensation (풍력발전단지 출력보상용 하이브리드 에너지저장장치의 용량산정)

  • Kim, Seong Hyun;Jin, Kyung-Min;Oh, Sung-Bo;Kim, Eel-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.23-30
    • /
    • 2013
  • This paper presents the determination method of the hybrid energy storage capacity for compensating the output of wind power when disconnecting from the grid. In the wind power output compensation, a lot of charging and discharging time with lithium-ion battery will be deteriorated the life time. And also, this fluctuation will cause some problems of the power quality and power system stability. To solve these kind of problems, many researchers in the world have been studied with BESS(Battery Energy Storage System) in the wind farm. But, BESS has the limitation of its output during very short term period, this means that it is difficult to compensate the very short term output of wind farm. Using the EDLC (Electric Double Layer Capacitor), it is possible to solve the problem. Installing the battery system in the wind farm, it will be possible to decrease the total capacity of BESS consisting of HESS (Hybrid Energy Storage System). This paper shows simulation results when not only BESS is connected to wind farm but also to HESS. To verify the proposed system, results of computer simulation using PSCAD/EMTDC program with actual output data of wind farms of Jeju Island will be presented.

Failure analysis of capacitor for sub-module in HVDC (HVDC 서브모듈용 커패시터의 고장 분석)

  • Kang, Feel-soon;Song, Sung-Geun
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.941-947
    • /
    • 2018
  • In general, capacitors have a large influence on the life of the system due to frequent charging and discharging. In this paper, we analyze the cause of the core failure of high voltage, high current HVDC sub-module film capacitor and analyze the precautions of the capacitor design and manufacturing process. First, the cause of the fault, the failure mode, and the effect are analyzed through the FMEA of the capacitor. To quantitatively evaluate the causes and effects of faults that have the greatest effect on the failure of a capacitor, a fault tree for the capacitor is presented and the failure rate is analyzed according to the design parameters and the driving conditions. It is verified that the main cause of capacitor failure is the capacitance change, and it is necessary to minimize the temperature rise, corona occurrence, electrode expansion, and insulation distance decrease during capacitor design and manufacturing process in order to reduce the failure rate of the capacitor.

Monitoring System of AtoN Charge and Discharge Controller (항로표지 충·방전조절기의 모니터링 시스템)

  • Ye, Seong-hyeon;Han, Soonhee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.639-642
    • /
    • 2014
  • If the power of the general is not supplied, Visual aids utilize solar power system. The power supply system of these, the role of the power regulator to manage the charging and discharging is very important. In recent years, by introducing the IT technology for the effective management of visual aids, it was supposed to add a device that uses the power consumption. Thus, the importance of power regulator has increased. Currently, the power regulator is installed inside the AtoN, if the accessibility is not ensured, there is a difficulty that can not be checked. In order to solve these problems, in this paper, you have installed the Blue-tooth module to the power regulator. Also, by using the Blue-tooth communication function of a smart phone, a radio check has implemented a possible monitoring system. Advantage of the system implemented is a simple configuration and low installation cost. Also, it is possible to check the state information of the real-time power supply regulator. In addition, it has the effect of preventing accidents and reducing costs of inspection.

  • PDF

Fault-tree based reliability analysis for bidirectional converter (고장나무를 이용한 양방향 컨버터의 신뢰성 분석)

  • Heo, Dae-ho;Kang, Feel-soon
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.254-260
    • /
    • 2019
  • The failure rate of bidirectional dc-to-dc converter is predicted through the failure mode and effect analysis (FMEA) and the fault-tree analysis (FTA) considering the operational risk. In order to increase the driving voltage of the electric vehicle efficiently, the bidirectional converter is attached to the front of the inverter. It has a boost mode for discharging battery power to the dc-link capacitor and a buck mode for charging the regenerative power to the battery. Based on the results of the FMEA considering the operating characteristics of the bidirectional converter, the fault-tree is designed considering the risk of the converter. After setting the design parameters for the MCU for the electric vehicle, we analyze the failure rate of the capacitor due to the output voltage ripple and the inductor component failure rate due to the inductor current ripple. In addition, we obtain the failure rate of major parts according to operating temperature using MIL-HDBK-217F. Finally, the failure rate and the mean time between failures (MTBF) of the converter are predicted by reflecting the part failure rate to the basic event of the fault-tree.