• Title/Summary/Keyword: charging system

Search Result 1,153, Processing Time 0.028 seconds

Development of Vibration Powered Generator for Vibration Monitoring (진동모니터링을 위한 자가진동발전기의 개발)

  • 김재민;최남섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.434-441
    • /
    • 2003
  • This paper presents a generator for stand-alone vibration monitoring system of bridge structure based on ambient vibration of bridge. In this paper, a novel electric power generator which has minimum effect of armature reaction is proposed. The related mechanical and electrical design equations are obtained and a pilot generator has been implemented. In addition, the charging system for extremely low generator current is discussed, and some improvements are identified for the system. This investigation reveals that diode characteristics of rectifier is dominant factor in the charging process. Finally, both the simulation, which uses real measurement data of the Namhae bridge as input of the pilot generator, and indoor test are carried out. The results showed the applicability and effectiveness of the stand-alone vibration powered generator.

  • PDF

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

An Experimental Study on the Performance of Swash Plate Compressor with variations of Oil Charging Conditions (오일 충전량 변화에 따른 사판식 압축기 성능의 실험적 고찰)

  • Kim, Min-Jun;Park, Ik-Seo;Lee, Geon-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.704-709
    • /
    • 2003
  • The automobile air conditioning system generally consists of laminated type evaporator, swash plate type compressor, condenser, expansion valve and receiver drier. A swash plate type compressor has been used widely in automobile air conditioning system since 1955, because of wider operation range and better durability than other type compressors. In this study, the performance of an swash plate type compressor with variations of oil charging conditions has been investigated experimentally using the hot gas system. Further, the effects of varying compressor speed on the performance of the compressor has been discussed.

  • PDF

A study on the improvement of efficiency in the light railway vehicle system using IPT (유도 급전을 이용한 경전철 시스템의 효율 개선에 대한 연구)

  • Choi, Seung-Cheol;Lee, Byung-Song;Mok, Hyung_Soo
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.62-63
    • /
    • 2010
  • This paper presents a potential for application of Inductive Power Transfer(IPT) to the light railway vehicle system. IPT system allows for a vehicle fitted with existing or new generation batteries to park over a small charging unit and commence charging immediately. Regular charging will allow for smaller batteries to be used in vehicles. In this paper, IPT system uses a full-bridge LLC resonant converter and is possible for the regenerative braking which is an energy recovery mechanism.

  • PDF

Control Strategies of Mobility Charging Systems Using PV-ESS Systems (태양광 발전과 에너지저장시스템을 활용한 모빌리티 충전 시스템의 제어 방법)

  • Kim, Dae-Won;Lee, Hyeon-Min;Park, Sung-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.334-341
    • /
    • 2021
  • Operation modes and control strategies for single-phase mobility charging station utilizing photovoltaic (PV) generation and energy storage systems (ESS) are proposed. This approach generates electric power from PV to transmit the mobility, ESS, and then transfer it to the grid when surplus electric power is generated during daytime. However, the PV power cannot be generated during night-time, and ESS and the mobility system can be charged using grid power. The power balance control based on power fluctuations and the resonant current control that can compensate harmonic components have been added to increase the stability of the system. The MATLAB/Simulink simulation was carried out to verify the proposed control method, and the 2-kW single-phase grid-tied PV-ESS smart mobility charger was built and tested.

Standard Strategies for Convergence Industries: A Case of Clash between Electric Vehicle Charging Standards and Smart Grid Communication Standards (미래 융합산업 표준 전략: 전기 자동차 충전 표준과 스마트그리드 통신 표준 충돌 사례)

  • Huh, Joon;Lee, Heejin
    • Journal of Technology Innovation
    • /
    • v.23 no.3
    • /
    • pp.137-167
    • /
    • 2015
  • Based on the stakeholder theory, this paper analyzes a clash of standards in Korea's Electric Vehicle(EV) market, particularly between an EV charging standard and a smart grid communication standard in 2012~2013. For charging, EV is connected with the electric power grid and simultaneously exchanges data regarding the charging status. When EV is connected with the power grid, a clash between two standards may arise. It actually happened when BMW entered into the Korean EV market with the DC Combo charging system. In that course, the frequency interference occurred between the EV data communication technology adopted by BMW and the AMI(Advanced Metering Infrastructure) for the smart grid system in Korea. Standardization of Korea's EV charging systems was required to solve this problem. However, it had been delayed due to the confrontation between various stakeholders involved in the process of standardization. It lasted until the DC combo was accepted as one of the Korea EV charging standards(KSAE SAE 1772-2040, 2014.1) by KSAE(The Korea Society of Automotive Engineers) in January 2014. This is an interesting case in the age of convergence. As it deals with the standard competition not among EV standards, but a clash between the EV industry and the smart grid, i.e. electric power industry, it addresses the necessity to consider standardization processes between different industries. This study draws on the stakeholder theory to analyse the dynamics of the standard clash between EV charging systems and the smart grid system, which is a unique example of standard clash between different industries. We expect such clashes to increase in the age of convergence.

The study on appropriateness of adapting door-to-door delivery system for the reducong of waiting time at outpatient pharmacy department in Tertiary care hospital (3차 진료기관 외래약국 투약대기시간 단축을 위한 택배 제도 도입 타당성 조사)

  • Song, Jung-Hup
    • Quality Improvement in Health Care
    • /
    • v.3 no.1
    • /
    • pp.144-152
    • /
    • 1996
  • Background : Because of introduction of nationwide health care system in 1989 and the improvement of socioeconomic status of population the number of outpatient visiting university hospital has good facilities and manpower has increased. So the waiting time for medical service at university hospital are lengthened. Particularly outpatients complain that waiting for prescribed drugs at pharmacy depart are long. Reducing waiting time at pharmacy depart door-to-door delivery system that the patients applying for door-to-door delivery receive prescribed drug at home without waiting at pharmacy depart were studied. The objective of this study is to analysis the opinion of outpatients for door-to-door delivery system, to study the appropriateness of adopting the system and to produce ideal model for the system. Method : Outpatients waiting drug at pharmacy depart were questioned about door-to-door delivery system. to find the factors affect utilizing the system the logistic regression was used. Result : 83.3% of the patients want to utilize the system without charging, and 72.9% of the patients want to utilized system with charging. 68.3% of patients with charging want to use this system because of long waiting time at pharmacy depart. 50% of patients who do not want to use door-to-door do not use this system because of incorrect delivery. The affecting factors to utilize the system were sex, waiting time, fee. Conclusion : The model for door to door delivery system. 1. door-to-door personnel reside in hospital and the patient want to utilize the system apply for the delivery with charging. 2. The applied drugs dispense at spare time. 3. Delivery company gathers drug at appointed time and delivers. 4. The delivery fee is 2,000-3,000 won. 5. To prevent from loss and changing the drug the name of patient on packet are printed and drug packet are sealed. 6. The company submit the confirm sheet which are written that the patient received drug correctly to hospital. 7. The delivery time of drug is reserved for the convenience of receiving.

  • PDF

Mobile Edge Computing based Charging Infrastructure considering Electric Vehicle Charging Efficiency (전기자동차 충전 효율성을 고려한 모바일 에지 컴퓨팅 기반 충전 인프라 구조)

  • Lee, Juyong;Lee, Jihoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.669-674
    • /
    • 2017
  • Due to the depletion of fossil fuels and the increase in environmental pollution, electric vehicles are attracting attention as next-generation transportation and are becoming popular all over the world. As the interest in electric vehicles and the penetration rate increase, studies on the charging infrastructure with vehicle-to-grid (V2G) technology and information technology are actively under way. In particular, communication with the grid network is the most important factor for stable charging and load management of electric vehicles. However, with the existing centralized infrastructure, there are problems when control-message requests increase and the charging infrastructure cannot efficiently operate due to slow response speed. In this paper, we propose a new charging infrastructure using mobile edge computing (MEC) that mitigates congestion and provides low latency by applying distributed cloud computing technology to wireless base stations. Through a performance evaluation, we confirm that the proposed charging infrastructure (with low latency) can cope with peak conditions more efficiently than the existing charging infrastructure.

Evaluation of Operational Efficiency for Electric Vehicle Charging Stations Using Data Envelopment Analysis (자료포락분석을 이용한 전기차 충전소 운영효율성 평가)

  • Son, Dong-Hoon;Gang, Yeong-Su;Kim, Hwa-Joong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.3
    • /
    • pp.53-60
    • /
    • 2020
  • Evaluating the operational efficiency of electric vehicle charging stations (EVCSs) is important to understand charging network evolution and the charging behavior of electric vehicle users. However, aggregation of efficiency performance metrics poses a significant challenge to practitioners and researchers. In general, the operational efficiency of EVCSs can be measured as a complicated function of various factors with multiple criteria. Such a complex aspect of managing EVCSs becomes one of the challenging issues to measure their operational efficiency. Considering the difficulty in the efficiency measurement, this paper suggests a way to measure the operational efficiency of EVCSs based on data envelopment analysis (DEA). The DEA model is formulated as constant returns of output-oriented model with five types of inputs, four of them are the numbers of floating population and nearby charging stations, distance of nearby charging stations and traffic volume as desirable inputs and the other is the traffic speed in congestion as undesirable one. Meanwhile, the output is given by the charging frequency of EVCSs in a day. Using real-world data obtained from reliable sources, we suggest operational efficiencies of EVCSs in Seoul and discuss implications on the development of electric vehicle charging network. The result of efficiency measurement shows that most of EVCSs in Seoul are inefficient, while some districts (Nowon-gu, Dongdaemun-gu, Dongjak-gu, Songpa-gu, Guro-gu) have relatively more efficient EVCSs than the others.

The Efficient Maintenance System of Lead-acid Battery Based on the Analysis of Charging/Discharging Current (충.방전 전류해석을 통한 납축전지의 효율적인 관리시스템)

  • 박영산;황종구
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.158-169
    • /
    • 2004
  • The efficient maintenance system of lead-acid battery was builted based cm analysis of charging and discharging current. This system was designed for the purpose of protecting the overdischarge of battery. So, We could protect the shortening lifetime of battery. It is checked the charging and discharging current of battery to decide the cut-off point by $\mu$-processor 80c196. Two current sensors were used to sense the current and the $\mu$-processer calculated amount of charging and discharging current of battery. And then display the state of charge.