• Title/Summary/Keyword: charge passed

Search Result 81, Processing Time 0.028 seconds

Analysis on Changes in Strength, Chloride Diffusion, and Passed Charges in Normal Concrete Considering Ages and Mix Proportions (재령 및 배합특성을 고려한 보통 콘크리트의 강도, 염화물 확산계수, 통과전하량 변화 분석)

  • Lee, Hack-Soo;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Concrete behavior in early-age is changing due to hydration reaction with time, and a resistance to chloride attack and strength development are different characterized. In the present work, changing strength and resistance to chloride attack are evaluated with ages from 28 days to 6 months. For the purpose, strength, diffusion coefficient, and passed charge are evaluated for normal concrete with 3 different mix proportions considering 28-day and 6-month curing conditions. With increasing concrete age, the changing ratio of strength falls on the level of 135.3~138.3%, while diffusion coefficient and passed charge shows 41.8%~51.1% and 53.6%~70.0%, respectively. The results of chloride diffusion coefficient and passed charge show relatively similar changing ratios since they are much dependent on the chloride migration velocity in electrical field. The changing ratios in chloride behaviors are evaluated to be much larger than those in compressive strength since the ion transport mechanism is proportional to not porosity but square of porosity.

Quantification of Half Cell Potential with Mix Properties in RC Member under Long-Term Chloride Exposure Conditions (장기 염해에 노출된 RC 부재의 배합 특성을 고려한 반 전위의 정량화)

  • Yoon, Yong-Sik;Jeong, Gi-Chan;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.307-313
    • /
    • 2022
  • In this study, the correlation between Half Cell Potential(HCP) and the corrosion influencing factors was analyzed with considering three levels of water-cement ratio, the concentration of chloride solution, and cover depth. As a result of long-term corrosion monitoring, HCP behavior was close to the critical corrosion potential(-350 mV) in all water-cement ratios in the case of 3.5 % and 7.0 % chloride concentration. Regarding the passed charge test in 548 curing days, the passed charge results were improved to 'Moderate' grade. Multiple regression analysis was performed to evaluate the correlation between corrosion influencing factors and HCP, and it was evaluated that the effects of influencing factors to HCP were in the order of chloride concentration, water-cement ratio, and cover depth. In the case of the relationship between HCP and the passed charge, the coefficient of determination showed a high level of 0.9, which yielded a close correlation between the passed charge and HCP.

Prediction Equation for Chloride Diffusion in Concrete Containing GGBFS Based on 2-Year Cured Results (2년 양생 실험결과를 이용한 고로슬래그 미분말 콘크리트의 염화물 확산 예측식)

  • Yoon, Yong-Sik;Cho, Sung-Jun;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.1-9
    • /
    • 2019
  • GGBFS(Ground Granulated Blast Furnace Slag), one of the representative concrete mineral admixtures, improves the long-term durability and engineering performance of concrete by latent hydraulic activity. In this study, considering 3 levels of W/B(0.37, 0.42, 0.47) and GGBFS replacement ratio(0 %, 30 %, 50 %), durability performances for chloride attack are evaluated, and equations which predict behavior of accelerated chloride diffusion are proposed. Also, the relationship between accelerated chloride diffusion coefficient and passed charge is evaluated. In target curing day, accelerated chloride diffusion tests(Tang's method, ASTM C 1202) and compressive strength(KS F 2405) are performed. In the 730 day's results of accelerated chloride diffusion coefficient, GGBFS concrete has up to 28 % of decreasing ratio compared to OPC concrete, and in those of passed charge, GGBFS concrete has up to 29 % of decreasing ratio compared to OPC concrete. Also, it is deemed that the impact of variation of W/B is less in GGBFS concrete than in OPC concrete. The equations which predict accelerated chloride diffusion coefficient and passed charge are drawn, based on the characteristics of mixture and test results. The equation which predicts passed charge shows slightly higher coefficient of determination than that which predicts accelerated chloride diffusion coefficient.

Chloride penetration resistance of concrete containing ground fly ash, bottom ash and rice husk ash

  • Inthata, Somchai;Cheerarot, Raungrut
    • Computers and Concrete
    • /
    • v.13 no.1
    • /
    • pp.17-30
    • /
    • 2014
  • This research presents the effect of various ground pozzolanic materials in blended cement concrete on the strength and chloride penetration resistance. An experimental investigation dealing with concrete incorporating ground fly ash (GFA), ground bottom ash (GBA) and ground rice husk ash (GRHA). The concretes were mixed by replacing each pozzolan to Ordinary Portland cement at levels of 0%, 10%, 20% and 40% by weight of binder. Three different water to cement ratios (0.35, 0.48 and 0.62) were used and type F superplasticizer was added to keep the required slump. Compressive strength and chloride permeability were determined at the ages of 28, 60, and 90 days. Furthermore, using this experimental database, linear and nonlinear multiple regression techniques were developed to construct a mathematical model of chloride permeability in concretes. Experimental results indicated that the incorporation of GFA, GBA and GRHA as a partial cement replacement significantly improved compressive strength and chloride penetration resistance. The chloride penetration of blended concrete continuously decreases with an increase in pozzolan content up to 40% of cement replacement and yields the highest reduction in the chloride permeability. Compressive strength of concretes incorporating with these pozzolans was obviously higher than those of the control concretes at all ages. In addition, the nonlinear technique gives a higher degree of accuracy than the linear regression based on statistical parameters and provides fairly reasonable absolute fraction of variance ($R^2$) of 0.974 and 0.960 for the charge passed and chloride penetration depth, respectively.

Study on electrical charge distribution of aerosol using a Gerdien ion counter (Gerdien 이온측정기를 이용한 에어로졸의 하전 특성 분석에 관한 연구)

  • Joe, Yun-Haeng;Shim, Joonmok;Shin, Il-Kyoung;Yook, Se-Jin;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2018
  • Since the motion of the charged particle strongly depends on its charge characteristics, information on charge distributions of target particles is one of the important variables in aerosol research. In this study, charged distribution of atomized NaCl particles were measured using a Gerdien type ion counter. Two kinds of particle charging conditions were used in this study. First, atomized NaCl particles were passed through an aerosol neutralizer to have a Boltzmann charge distribution, and then its charge distribution was measured. In this case, the portion of uncharged particles was compared with the portion obtained from the Boltzmann charge distribution for verifying the suggested experimental method. Second, same experiment was conducted without the aerosol neutralizer to measure the charge distribution of atomized and un-neutralized NaCl particles. In the conclusion, the portion of uncharged, negatively charged and positively charged particles were 19%, 62% and 20%, respectively, for neutralized particles. The atomized particles, which was generated without the aerosol neutralizer, also had almost a zero charge state, but the standard deviation in charge distribution was larger than that of neutralized particles. The test method proposed in this study is expected to be used in various aerosol research fields because it can obtain simple information on the particle charge characteristics more easily and quickly than the existing test methods.

Quantitative estimation of reversibility of the discharge process undergone by nickel hydroxide film cathodically deposited on pure nickel as a positive supercapacitor electrode using cyclic voltammetry and potential drop method

  • Pyun Su-Il;Moon Sung-Mo
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.8-13
    • /
    • 1998
  • This work presents the way how to evaluate the degree of reversibility of the discharging process undergone by the nickel hydroxide film cathodically deposited on pure nickel as a positive electrode for electrochemical capacitor using the combined cyclic voltammetry and potential drop method, supplemented by galvanostatic discharge and open-circuit potential transient methods. The time interval necessary just to establish the current reversal of anodic to cathodic direction from the moment just after applying the potential inversion of anodic to cathodic direction, was obtained on cyclic voltammogram. The cathodic charge density passed upon dropping the applied potential, was calculated on potentiostatic current density-time curve. Both the time interval and the cathodic charge density in magnitude can be regarded as being measures of the degree of reversibility of the discharging process undergone by the positive active material for supercapacitor, i.e. , the longer the time interval is, the lower is the degree of reversibility and the greater the cathodic charge density is, the higher is the degree of reversibility. From the applied potential dependences of the time interval and cathodic charge density, discharge at $0.42 V_{SCE}$ was determined to be the most reversible.

The performance of a heat pump with 3-piping system at various charging conditions (3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF

The Performance of a Simultaneous Heat and Cooling Heat Pump at Various Charging Conditions (동시냉난방 히트펌프의 냉매 충전량과 운전모드 변화에 따른 성능특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.492-499
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

The Prediction of Durability Performance for Chloride Ingress in Fly Ash Concrete by Artificial Neural Network Algorithm (인공 신경망 알고리즘을 활용한 플라이애시 콘크리트의 염해 내구성능 예측)

  • Kwon, Seung-Jun;Yoon, Yong-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.127-134
    • /
    • 2022
  • In this study, RCPTs (Rapid Chloride Penetration Test) were performed for fly ash concrete with curing age of 4 ~ 6 years. The concrete mixtures were prepared with 3 levels of water to binder ratio (0.37, 0.42, and 0.47) and 2 levels of substitution ratio of fly ash (0 and 30%), and the improved passed charges of chloride ion behavior were quantitatively analyzed. Additionally, the results were trained through the univariate time series models consisted of GRU (Gated Recurrent Unit) algorithm and those from the models were evaluated. As the result of the RCPT, fly ash concrete showed the reduced passed charges with period and an more improved resistance to chloride penetration than OPC concrete. At the final evaluation period (6 years), fly ash concrete showed 'Very low' grade in all W/B (water to binder) ratio, however OPC concrete showed 'Moderate' grade in the condition with the highest W/B ratio (0.47). The adopted algorithm of GRU for this study can analyze time series data and has the advantage like operation efficiency. The deep learning model with 4 hidden layers was designed, and it provided a reasonable prediction results of passed charge. The deep learning model from this study has a limitation of single consideration of a univariate time series characteristic, but it is in the developing process of providing various characteristics of concrete like strength and diffusion coefficient through additional studies.

The Mechanical Properties of Concrete Using Blended Super Low Heat Cement (혼합형 초저발열 시멘트를 사용한 콘크리트의 물성-현수교 앵커리지 콘크리트 대상-)

  • 송용순;강석화;손명수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.341-344
    • /
    • 1999
  • In the case of the offshore concrete structures like the anchorage block of a suspension bridge of Kwangan Grand Road, there is a need of the concrete which has low heat of hydration and good resistance for sea-water attack. In this study, the blended super low heat cement which satisfies that requirement was developed and several tests were carried out. The concrete using the blended super low heat cement showed lower adiabatic temperature rise than 3$0^{\circ}C$ and good early strength. Also, its passed charge(coulomb) to resist chloride ion penetration was very low.

  • PDF