• Title/Summary/Keyword: charge

Search Result 10,804, Processing Time 0.052 seconds

Spray Characteristics of Charge Injected 2-fluid Nozzle for Non-conducting Liquid (비전도성 액체의 전하주입형 2-유체 노즐에 대한 분무 특성)

  • Park, Min-Gyu;Choi, Young-Joo;Kim, Sang-Soo
    • Journal of ILASS-Korea
    • /
    • v.11 no.3
    • /
    • pp.155-160
    • /
    • 2006
  • Spray characteristics of charge injected 2-fluid nozzle for non-conducting liquid have been studied. Spray current, specific charge and SMD of diesel have been measured. Spray current and specific charge are proportional to applied voltage. Air flow did not effect on spray current and specific charge. SMD decreases as air flow rate increases and decreases as applied voltage increases additionally. Spray angle increases as applied voltage increases. Fine droplets are obtained by charge injected 2-fluid nozzle without charge loss.

  • PDF

Interfacial Properties of a-Se Thick Films to Solve Charge Trap and Injection Problems (전하 트랩 및 주입 문제를 해결하기 위한 비정질 셀레늄 필름의 계면 특성)

  • 조진욱;최장용;박창희;김재형;이형원;남상희;서대식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.497-500
    • /
    • 2001
  • Due to their better photosensitivity in X-ray, the amorphous selenium based photoreceptor is widely used on the X-ray conversion materials. It was possible to control the charge carrier transport of amorphous selenium by suitably alloying a-Se with other elements(e,g. As, Cl). The charge transport properties of amorphous Selenium is decided on hole which is induced from metal to selenium in metal-selenium junction and which is transferred in a-Se bulk. This phenomenon is resulted of changing electric field owing to increasing of space charge by deep trap of a-Se bulk. In this paper, We dopped the chlorine to compensate deep hole trap and deposited blocking layer using dielectric material to prevent from increasing space charge for injection charge between metal electrode and a-Se layer. We compared space charge and the decreasing of trap density through measuring dark and photo current.

  • PDF

Modularized Charge Equalization Converter for Hybrid Electric Vehicle Lithium-Ion Battery Stack

  • Park, Hong-Sun;Kim, Chong-Eun;Kim, Chol-Ho;Moon, Gun-Woo;Lee, Joong-Hui
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.350-352
    • /
    • 2007
  • Modularized charge equalization converter for HEV lithium-ion battery cells is proposed in this paper, in which intra-module and inter-module charge equalization can be achieved at the same time. For intra-module charge equalization, the conventional flyback DC/DC converters of low power and small size are employed, in which all of the primary sides are coupled in parallel for selective charge of the specific under charged cell within the module. For inter-module charge equalization, the flyback DC/DC converters are also added, in which all the secondary windings are electrically linked in parallel for automatic charge balancing among the modules. An engineering sample of forty cells hiring the proposed cell balancing scheme is implemented and its experimental result shows that the proposed modularized charge equalization circuit has good cell balancing performance.

  • PDF

Three Dimensional Electric Field Analysis Of Substation Using Nonuniform Optimal Charge Simulation (비균등 최적 전하배치를 이용한 전력소 3차원 전계해석)

  • Myung, Sung-Ho;Lee, Byeong-Yoon;Min, Suk-Won;Kim, Eung-Sik;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.290-292
    • /
    • 1994
  • This paper presents a methodology for the electric field analysis of substation. For the electric field analysis of substation, the electrodes(substation busbars) must be represented by finite line with nonlinear charge density. In the case of dividing finite line into uniform segments, a large number of variables have to be used to obtain the accuracy within a desired tolerance. To deal with the problem, nonuniform charge arrangement modeling method is suggested. To reduce potential calculation errors, the linear charge density function is considered particularly for the segment charge model ling. If the charge arrangement is improper, the accuracy not improved regardless of increment in the number of segments. This paper proposes an optimal charge arrangement method through potential error analysis. And, the optimal charge arrangement function is formulated by a lot of simulation results.

  • PDF

Combustion Characteristics of Methane-Air Mixture in a Constant Volume Combustion Chamber(3) : Exhaust Emission (정적연소기에서의 메탄-공기 혼합기의 연소특성(3) : 배기배출물)

  • 최승환;전충환;장영준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • A cylindrical constant volume combustion chamber was used to investigate the exhaust emission characteristics of homogeneous charge, stratified pattern and inhomogeneous charge under various conditions using gas chromatography. In the case of homogeneous charge condition, the $CO_2$ concentration is proportional to excess air ratio and overall charge pressure, the $CO_2$ concentration is proportional to excess air ratio and the UHC concentration is inversely proportional to ignition time and overall charge pressure. In the case of stratified pattern, the RI(rich injection) condition shows better exhaust emission characteristics, especially $CO_2$, than that of HI (homogeneous injection) or LI (lean injection) conditions. In inhomogeneous charge conditions, when initial charge pressure is increased, $CO_2$ and UHC concentration is reduced but $O_2$ concentration is increased. And when the excess air ratio of initial charge mixture is 3.0, UHC and $CO_2$concentration show lowest values.

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Type Ground Source Heat Pump with a Variation of Compressor Speed and Water Flow Rate (용량 가변 및 유량변화에 따른 지열원 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chan-Yong;Choi, Jong-Min
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.30-36
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWTs of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system was optimized at higher refrigerant charge amount conditions.

Influence of Endurance tests on Space Charge Distribution of 160kV HVDC XLPE Cable

  • Liu, Yun-Peng;Liu, He-Chen
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.302-309
    • /
    • 2017
  • The ageing of XLPE cable insulation will lead to the accelerating accumulation of space charge, which will greatly affect the safe operation of the HVDC cable. In order to investigate the influence of different ageing modes on the space charge distribution of the HVDC cable, thermal stressed, electrical stressed and electro-thermal stressed endurance tests were carried out on the XLPE peelings. The tested XLPE peelings were obtained from 160kV HVDC cable insulation. The endurance tests were carried at thermal stress of 363K, electrical stress of 20kV/mm DC and a combination of both. The Pulsed Electro-Acoustic (PEA) method was used to measure the space charge distribution of the samples. The influences of ageing on the trap energy distribution were analyzed based on the isothermal relaxation theory and the decay characteristics of the space charge. The results showed that thermal ageing would help to improve the crystalline morphologies of the XLPE at the early stage. The total amount of space charge decreased compared to the ones before thermal ageing. The long term of electrical stress would result in the cleavage of polymer molecule chains which would intensify the accumulation of space charge and increase the density and depth of electron traps. With a combination of electrical and thermal stress, the injection and migration of space charge were more significant. Besides, the depth and density of electron traps increased rapidly with the increase of endurance time.

Layer Charge Characteristics of Smectite from the Pohang Area (포항지역에서 산출되는 스멕타이트의 층전하 특성)

  • Lee, Gyoo Ho;Ko, Jaehong;Moon, Hi-Soo
    • Economic and Environmental Geology
    • /
    • v.28 no.4
    • /
    • pp.315-326
    • /
    • 1995
  • The layer charge characteristics of smectites from the Tertiary basins in the Pohang area have been studied in detail using the alkyl-ammonium method. On the basis of layer charges, the smectite in the Pobang area can be classed as normal and high-charge (hc) smectite. The layer charge of the normal smectite averages 0.3, and ranges from 0.25 to 0.38/half unit cell. The hc-smectite collapses on K-saturation to become illite-like material and shows $10{\AA}$-series reflections on X-ray diffraction. The layer charge of the he-smectite ranges from 0.5 to 1. The layer cbarges of the Pohang smectite are in general heterogeneous. The layer charges distribute between 0.21 and 0.45, and the most frequent layer charge is 0.30~0.32. The layer charge and the layer charge distribution do not appear to be related to stratification or basins of occurrence. Thus, the layer charge may not have developed as a result of burial. Rather, it may have developed due to heat and hydrothermal solutions associated with volcanic activities. Volcanic sills and dykes are ubiquitous in the region.

  • PDF

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Heat Pump with a Variation of Compressor Speed and Water Flow Rate (압축기 용량 및 유량변화에 따른 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.143.1-143.1
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz, and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWT of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system optimized at higher refrigerant charge amount conditions.

  • PDF

Characteristics of Charge Accumulation in Glass Materials under E-Beam Irradiation (E-빔 조사하에서 유리의 전하축퇴 특성)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.377-378
    • /
    • 2008
  • Space charge formation in various glass materials under electron beam irradiation was investigated. Charging of spacecraft occurs in plasma and radiation environment. Especially, we focused on an accident caused by internal charging in a glass material that was used as the cover plate of solar panel array, and tried to measure the charge distribution in glass materials under electron beam irradiation by using a PEA (Pulsed Electro-Acoustic method) system. In the case of a quartz glass (pure $SiO_2$), no charge accumulation was observed either during or after the electron beam irradiation. On the contrary, positive charge accumulation was observed in glass samples containing metal-oxide components. It is found that the polarity of the observed charges depends on the contents of the impurities. To identify which impurity dominates the polarity of the accumulated charge, we measured charge distributions in several glass materials containing various metal-oxide components and calculated the trap energy depths from the charge decay characteristics of all glass samples. Furthermore, the dependence of the polarity of accumulated charges on the component of glass materials is discussed by using the models of energy bands.

  • PDF