• Title/Summary/Keyword: characteritics

Search Result 49, Processing Time 0.024 seconds

Impacts on the Deteriorative Breakdown Characteristics by the Void of Polyethyleme (Polyethylene의 공극이 절연파괴특성에 미치는 영향)

  • 정영순
    • 전기의세계
    • /
    • v.26 no.3
    • /
    • pp.59-62
    • /
    • 1977
  • This study is to investigate the v-t characteristics gained by means of the Weibull distribution and to analyze the characteritics of fatigue breakdown caused by the A-C voltage of cross-linked polyethylene with and without void. By the results, it has in most cases reveald deteriorative breakdown in case of none-void, and that random breakdown or complex Weibull distribution of deteriorative breakdown and random breakdown in case of with void.

  • PDF

A study on the comparison in different loading methods for pin-on-disk wear test system (마멸시험기의 하중부과 방법에 대한 비교 연구)

  • 서만식;구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.335-341
    • /
    • 1998
  • In this study, the dynamic characteritics in various loading methods for wear tester were investigated experimentally. As for the dead-weight, the pneumatic, and the hydraulic method, the load control performance against external disturbances was estimated under the several loading conditions like the different sliding speed, the varied normal load, and the misaligument. The hydraulic loading method showed the most stable loading performance of all the loading methods in the experiment.

  • PDF

A Study on the Characteritics of inductively Coupled Plasma by Numerical Simulation (수치해석에 의한 유도결합 플라즈마의 특성연구)

  • 김윤택;노영수;이홍식;황기웅
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.4
    • /
    • pp.457-465
    • /
    • 1994
  • 유도결합 플라즈마의 해석식으로 양극성 확산, 정상상태를 가정한 확산식, 열평형식과 변위전류 를 무시한 맥스웰 식을 사용하였다. 해석기법으로는 유한 차분법과 적분법을 축대칭 2차원(R, Z)모델에 적용하였다. 유도 결합 플라즈마장치의 RF 전력, 압력, 석영창 두께, 차폐부 높이에 따른 전자온도, 전자 밀도, 등가 정항 등가 인덕턴스 효율 결합계수 K, Q-factor의 변화를 구하였다. 특히 등가정항은 진공챔 버, 차폐부 및 코일의 손실저항을 고려하여 구하였다.

  • PDF

CHARACTERITICS OF MODIFIED PD OF ELECTROMAGNETIC SUSPENSION SYSTEM FOR NON-CONTACT STEEL PLATE CONVEYANCE

  • Xu, Dehong;Sun, Xiao;Feng, Wei
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.131-136
    • /
    • 1998
  • Based on the linear model of electromagnetic suspension (EMS) system, it is able to be further simplified into a standard second-order model with a modified PD control. In this paper static and dynamic characteristics of EMS with modified PD control are investigated when suspended weight of steel plate change. A experimental system has been built to verify static and dynamic characteristics of EMS system. Simulation and experiment are both given.

  • PDF

Breakdown Characteritics of XLPE/EPDM on the Treatment Condition of the Interfacial layer (XLPE/EPDM의 계면처리조건에 따른 절연파괴 특성)

  • 한성구;조정형;이창종;박양범;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.230-233
    • /
    • 1996
  • In this paper, We intended to evaluate characteristics of XLPE/EPDM interface which exists in the cable joint. Because the fault was mainly occurred in this interface. We investigated breakdown characteristics of XLPE/EPDM double layered insulator as a funtion of temperature, pressure, annealing time, kinds of jointmaterial. It was shown that breakdown strength of XLPE/EPDM insulators is higher that of XLPE/XLPE or EPDM/EPDM

  • PDF

Estimation of Storage Deficit by Run's Characteritics (Runs의 특성에 의한 지속기간별 저수부족량의 추정)

  • 강관원;안경수
    • Water for future
    • /
    • v.19 no.4
    • /
    • pp.329-338
    • /
    • 1986
  • the purpose of this study is to estimate the storage deficit by Run's Characteristics of (-)Run-length and (-)Run-sum. Runoff data are obtained from the guaging stations of Y대-Ju in Hanriver Basin, Wae-Gwan in Nak Dong River Basin and Gyo Am in Geum River Basin. In order to estimate the storage deficit, runhydrographs are established with each return period of 10, 30, ......, 200 years and regression equation is derived from relationship between (-) run-length and storage deficit. From the comparison of estimated reservoir storage with observed values., it was proved that this suggested method can be used for the estimation of the storage deficit.

  • PDF

Current Control Method of WRSM in High-speed Operation Range

  • Lee, Jae-Jun;Lee, Ki-Doek;Jang, Ik-Sang;Lee, Sung-Gu;Chae, Woong-Chan;Lee, Hyung-Woo;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2052-2056
    • /
    • 2015
  • This Paper analyzes the characteristics of the WRSM in high-speed operation range. To verify the control characteritics of various WRSM models, the relative position of the central point of current limit circle and voltage limit ellipse is defined as M value and 3 models according to Mmax value are designed through inductance change. Through the designed models, the current control method of 3-variables control for maximum power especially in high-speed operation range is presented.