• Title/Summary/Keyword: characteristics of thermal temperature

Search Result 3,551, Processing Time 0.028 seconds

Thermal Characteristics of Hydrostatic Guideway in Ultra Precision Positioning (초정밀위치결정을 위한 유정압안내면의 온도특성 분석)

  • 박천홍;오윤진;황주호;이득우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.37-41
    • /
    • 2002
  • Thermal characteristics of hydrostatic guideway is largely depended on the temperature of supplied oil. For improving the positioning accuracy of hydrostatic guideway, relationship between setting temperature of oil cooler and thermal characteristics is analyzed, and influence of thermal characteristics on positioning accuracy is also analyzed experimental1y in this paper. Laser scale which has 0.01 $\mu\textrm{m}$ of resolution is used as feed-back unit. From the experimental results, it is confirmed that positioning error and repeatability is minimize upto 0.21 $\mu\textrm{m}$ and 0.18 $\mu\textrm{m}$ when the temperature of supplied oil is setting equal to temperature of atmosphere, and also confirmed that thermal deformation, which occurs by the temperature deviation between table and rail or scale supporter, works as limit of repeatability in long time operation.

  • PDF

Study on Thermal Pattern and Current Characteristics of an LED Street Lamp (LED 가로등의 발열 패턴 및 전류 특성에 관한 연구)

  • Kim, Hyang-Kon;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.357-361
    • /
    • 2009
  • This study performed analysis on the thermal pattern and current characteristics of an LED ((Light Emitting Diode) street lamp. It did this using a TVS (Thermal Video System) to analyze the LED street lamp's thermal pattern, and measured its characteristics using an oscilloscope. The ambient temperature and humidity during the experiment were maintained at $24{\pm}2[^{\circ}C]$ and 50~60[%]. The capacity of the LED street lamp was 120[W] and nine sets of modules were arranged at uniform intervals. On one module, 24 LED lamps were arranged in a radial pattern. The analysis of the thermal diffusion pattern at the front of the LED lamp showed that the maximum surface temperature was approximately $34[^{\circ}C]$. In addition, there was almost no change in the temperature of the upper cover, and the temperature at the side showed a uniform thermal diffusion pattern. The surface temperature of the converter converting AC to DC increased to approximately $46[^{\circ}C]$. The analysis results of the thermal characteristics of one LED indicated uniform thermal characteristics for an initial eight minutes. However, the temperature at the center of the LED increased to approximately $82[^{\circ}C]$ after 12 minutes had elapsed. It can be seen from this that the temperature at the center of the LED was higher than the allowable temperature, $70[^{\circ}C]$ of the insulating material for general electrical devices. Therefore, it is necessary to design a lamp in such a way that the plastic insulating material does not come into contact with or get close to the LED lamp. The voltage of the LED lamp converted by the AC/DC converter was measured at DC 27[V] and the current was DC 13[A]. Consequently, it can be seen that in order to secure an adequate light source, it is important to supply a stable current that was greater than the current of other light sources. Therefore, appropriate radiation of heat is required to secure the stability and reliability of the system.

Effects of some factors on the thermal-dissipation characteristics of high-power LED packages

  • Ji, Peng Fei;Moon, Cheol-Hee
    • Journal of Information Display
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Decreasing the thermal resistance is the critical issue for high-brightness light-emitting diodes. In this paper, the effects of some design factors, such as chip size (24 and 35 mil), substrate material (AlN and high-temperature co-fired ceramic), and die-attach material (Ag epoxy and PbSn solder), on the thermal-dissipation characteristics were investigated. Using the thermal transient method, the temperature sensitivity parameter, $R_{th}$ (thermal resistance), and junction temperature were estimated. The 35-mil chip showed better thermal dissipation, leading to lower thermal resistance and lower junction temperature, owing to its smaller heat source density compared with that of the 24-mil chip. By adopting an AlN substrate and a PbSn solder, which have higher thermal conductivity, the thermal resistance of the 24-mil chip can be decreased and can be made the same as that of the 35-mil chip.

Experimental Study on the Thermal Characteristics in Ondol Heating Systems (온돌난방주택의 난방방식별 열 특성에 관한 실험연구)

  • 윤정숙
    • Journal of the Korean housing association
    • /
    • v.1 no.1
    • /
    • pp.91-102
    • /
    • 1990
  • The aim of this study is to discover thermal characteristics of Ondol heating systems. The housing subjected was categorized into detached single family houses and apartments, reinforced concrete and brick structures, intermittent and continous heating system, and the space subjected was bedroom. In order to understand the thermal characteristics of each floor heating systems, the vertical distribution of indoor temperature and the distribution of surface temperature on the floor were measured. The vertical distribution of indoor temperature except the measurement point 1 largely showed average temperature distribution, and the temperature of the measurement point 1 in the housing surveyed showed the highest temperature in the house "sample A" because of the radiation heating from the floor of the Ondol room. As the result of the measurement, the thermal characteristics of each heating system were more stable distribution in apartments of R.C structure.structure.

  • PDF

A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics (바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

Thermal Characteristic Estimation of NC Machining Center Bed following Rib Structure (리브 구조에 따른 머시닝센터 베드의 열적 특성 평가)

  • Kim, Yang-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.746-752
    • /
    • 2010
  • Rib structure has been used to bed and column of machine tool to heighten weight stiffness ratio, cost performance and weight saving. In this paper the bed rib structure was estimated with thermal characteristics. Using superposition principle, machine tool designer can describe every complicated heat generation in the machine tool thermal source. As thermal characteristics, thermal deformation of guide rail and column and Maximum-minimum temperature variation were selected. The size, configuration and direction against the thermal loading surface operated to the thermal characteristics. The DB chart was made following rib structure estimating thermal characteristics. With superposition principle and DB chart, machine tool designer can prognosticate the thermal characteristics without FEM analysis to every bed rib structure.

Measurement of Ground Thermal Conductivity and Characteristics of Thermal Diffusion by the Ground Heat Exchanger (지중열전도도 측정과 지중열교환기의 열확산 특성 분석)

  • Jeong, Young-Man;Koo, Kyung-Min;Hwang, Yu-Jin;Jang, Se-Yong;Lee, Yeong-Ho;Lee, Dong-Hyuk;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.739-745
    • /
    • 2008
  • This paper presents the measurement of ground thermal conductivity and the characteristics of ground thermal diffusion by a ground heat exchanger(GHE). A borehole is installed to a depth of 175 m with a diameter of 150 mm. To analyze the thermal diffusion property of the GHE, thermocouples are installed under the ground near the GHE. The outdoor temperature, the ground temperature, and the water temperature of the GHE are monitored for evaluating the characteristics of ground thermal diffusion. The ground thermal conductivity is evaluated by the in-situ thermal response tester and the line source model. It is found to be 3.08 W/$m^{\circ}C$ in this study. The ground temperature is greatly dependent on the outdoor temperature from the ground surface to 2.5 m in depth and is stable below 10 m in depth. The surface temperature of the GHE varies as a function of the temperature of circulating water. But the ground temperature at 1.5 m far from the GHE is not changed in accordance with the temperature of circulating water.

Thermal Properties and Spray Characteristics of Kerosene Fuel at High Temperature and Pressure (고온고압 환경에서 케로신 연료의 물성치변화 및 분무특성연구)

  • Byeon, Yong-Woo;Son, Min;Koo, Ja-Ye
    • Journal of ILASS-Korea
    • /
    • v.15 no.2
    • /
    • pp.94-99
    • /
    • 2010
  • The object of this investigation is to study the thermal properties and spray characteristics of kerosene fuel in high temperature and pressure conditions. In order to investigate the thermal properties and spray characteristics, KIVA3 and SUPERTRAPP have been used at the same time. The thermal properties of kerosene has been calculated in high temperature and pressure condition using SUPERTRAPP. The study of spray characteristics has been conducted at both original properties of KIVA3 and calculated properties. The evaporation rate was increased in proportion to pressure when the calculated properties were used. However, the effect of pressure was not shown in the case of using original properties. So the calculated properties are more effective than original properties in high temperature and high pressure condition.

Static/Dynamic/Thermal Characteristics Analysis of a High-Speed Spindle System with 50,000rpm (50,000rpm급 초고속 주축계의 정적/동적/열적 특성 해석)

  • 김석일;조재완;이원재;이용희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.494-499
    • /
    • 2003
  • This paper concerns the static, dynamic and thermal characteristics analysis of a high-speed spindle system for horizontal machining centers with 45mm x50,000rpm. The spindle system is designed based on the angular contact ceramic ball bearings, built-in motor, oil-air lubrication method and oil jacket cooling method. The structural and thermal analysis models of spindle system are constructed by the finite element method. The static and dynamic characteristics are estimated based on the static deformation, modal parameter, mode shape and frequency response function, and the thermal characteristics are estimated based on the temperature rise, temperature distribution and thermal deformation. The analysis results illustrate that the designed spindle system has excellent structural and thermal stabilities

  • PDF

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.