• Title/Summary/Keyword: characteristic size

Search Result 2,188, Processing Time 0.033 seconds

A Study on the DWI and Pathologic Findings of Cancer Cells (암 세포주의 확산강조영상과 병리학적 관계에 관한 연구)

  • Seong, Jae-Gu;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.239-244
    • /
    • 2011
  • In this study, we evaluated diffusion weighted imaging (DWI) to investigate whether the DWI parameters can predict characteristic parameters on pathologic specimens of tumor or not. CFPAC-1 was injected subcutaneously on the back flank of athymic nude mice (n=13) then two tumors were initiated on each mouse (2${\times}$13=26 tumors). The mice were sacrificed to make specimen immediately after initial MR imaging then were compared with the MR image. A dedicated high-field (7T) small-animal MR scanner was used for image acquisitions. A T1 and T2 weighted axial image using RARE technique was acquired to measure the T2 values and tumor size. DWI MR was performed for calculating ADC values. To evaluate tumor cellularity and determine the levels of MVD, tumor cells were excised and processed for H-E staining and immunostaining using CD31. T2 values and ADC values were computed and analyzed for each half of the tumors and compared to the correlated specimens slide. Median ADC within each half of mass was compared to the cellularity and MVD in the correlated area of pathologic slide. The mean of ADC value is $0.7327{\times}10^{-3}$ $mm^2/s$ and standard deviation is $0.1075{\times}10^{-3}$ $mm^2/s$. There is a linear relationship between ADC value and tumor necrosis (R2=0.697, p< 0.001). DW image parameters including the ADC values can be utilized as surrogate markers to assess intratumoral neoangiogenesis and change of the internal structure of tumor cells.

An Analysis of Body Shapes in Aged Abdominal Obese Women for Apparel Pattern Design (복부비만 노년 여성의 의복패턴설계를 위한 체형연구)

  • Kim, Soo-A;Choi, Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.12 s.159
    • /
    • pp.1690-1696
    • /
    • 2006
  • The purpose of this study is to provide the basic data useful in designing apparel patterns for aged abdominal obese women. The body measurements of 318 women were taken at random, whose ages were over 60 and fields of action were colleges, sports centers, or business sites in Seoul and the neighboring districts. A total of 33 features in the upper body and lower body were used fer the anthropometric measurement and analysis using anthropometry. The collected measurement data were processed statistically using the SPSS 12.0 program for technical statistical analysis, t-test, frequency analysis, correlation analysis. The results of the study are as follows. 1. Subjects were classified into two groups as a result of analysis for measurement data. It was revealed that 251(about 79 percent) women of total subjects(n=318) have a characteristic of abdominal obese body type and elderly women of these group usually had big abdomen rather than hip. The criteria of abdominal obesity based on waist-hip ratio, WHR(=0.85). 2. Aged abdominal obese women have shown much larger size in most body measurements except items of some vertical length, such as bust ponit-bust point, font interscye, back interscye with circumference and depth of armscye, bust, waist, abdomen and hip while showing no difference in height, biacrominal breadth, hip width, neck shoulder point to breast point, crotch length. 3. Vervaeck index(=100.1) and Rohrer index(=1.7) indicated that the abdominal obese women were fat in overall body. And aspect ratio of waist(=0.86), abdomen(=0.92) and hip(=0.75) also appeared high that the shape of cross sections in those regions was similar to a figure of circle 4. In view of the correlation coefficient between hip circumference and the rest measurement items, and between hip circumference inclusively of the abdomen protrusion and the rest measurement items, there were found some differences for each group. In case of Group (abdominal obese group), the former is smaller than the other. 5. In case of Abdominal obese women, hip circumference inclusively of the abdomen protrusion is more mutually related to the rest items related to make apparel pattern as waist circumference, depth of armscye and so on than what hip circumference is. This result indicated which must be considered hip circumference inclusively of the abdomen protrusion to make apparel patterns for abdominal obese women unlike women of common body types.

Effectiveness and Preparation of Nano-emulsion of a Rapeseed Oil Extract Originated from Jeju with PIT Emulsifying System (PIT유화시스템을 이용한 제주산 유채씨앗 오일추출물의 나노에멀젼의 제조 및 효과)

  • Joo, Se-Jin;Kim, Hack-Soo;Lee, Jeong-Koo;Lee, Min-Hee;Kim, In-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.486-494
    • /
    • 2012
  • Nano-emulsion with phase inversion temperature (PIT) emulsifying system was prepared to use rapeseed oil from originating Jeju in order to apply various cosmetic applications. Natural rape seed oil (NRSO) extraction was extracted using n-hexane as a solvent. NRSO extract showed a light yellowish color of viscous liquid as well as yield was $43{\pm}2.5%$. Acid value was $2.76{\pm}0.5$ and gravity was $0.89{\pm}0.05$. Droplet size of PIT-Yuche-NE with 20wt% of rapeseed oil was 50-120nm (average: $82{\pm}5.8nm$) and zeta potential was -29.5mV. It was thermodynamically good stable emulsion due to $(PEG)_{5-30}$fattyacidether. Some conclusions from the result of characteristic experiment were obtained as follows. First, the anti-oxidative activity was measured by free radical scavenging activity using DPPH (1,1-diphenyl-2-picrylhydrazyl radical). Anti-oxidative activity of PIT-Yuche-NE was $37.2{\pm}6.7%$ on 10mg/mL compared with PIT-Toco-NE (Natural tocopherol nano-emulsion, $28.8{\pm}6.5%$ on 10 mg/mL) and PIT-Nokcha-NE (Green tea extract nano-emulsion, $29.6{\pm}7.2%$ on 10mg/mL). Second, the collagen synthesis activity of PIT-Yuche-NE was $148{\pm}15.2%$ compared with PIT-Toco-NE (Natural tocopherol nano-emulsion, $121{\pm}13.5%$ on 10mg/mL) and PIT-Nokcha-NE (Green tea extract nano-emulsion, $95{\pm}12.7%$ on 10mg/mL). Third, the effectiveness of moisturizing activity of Yuche-CRM with Aramo-TS after 6 hours increase $47{\pm}3.9%$ (*p-value£0.05, n=7) whereas Both Toco-CRM was $30{\pm}5.2%$ (*p-value£0.05, n=7) and Nokcha-CRM was $35{\pm}4.5%$. Therefore, Yuche-CRM has higher moisturizing effect than other two creams. Finally, Nano-emulsion stabilizing rapeseed oil using PIT emulsifying system of this study can be used to apply cosmetics industry and pharmaceutical industry.

Tissue Failure of the Low-Profile lonescu-Shiley Pericardial Valve in Mitral Position (승모판에서의 단고형 이오네스큐판막의 조직실패)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.670-676
    • /
    • 1997
  • The structural failure of the glutaraldehyde-treated xenograft valves has been the primary concern about the limited durability as predicted from the begimling of clinical use, and long-term follow-up has shown a significant incidence of primary tissue failure(PTF) from both biological and mechanical reasons. Twenty-seven patients with the low-profile lonescu-Shiley valves explanted from mitral position for PTF(Group III) were studied on the patient characteristics and valve pathology, and the results were compared with the matched observations of the Haycock(Group I) and of the standard-profile lonesiu-Shiley valves(Group II). Patients were aged 16 to 56 years(mean, 38.0$\pm$ 11.0 years), and the size of the failed mitral bioprosthesis was 30.8$\pm$ 1.3 mm. The hemodynamic consequences were stenosis in 29.6%, insufficiency in 44.4%, mixed steno-insufficiency in 14.8%, together with normal function for the rest of patients of prophylactic re-replacement. Pathology revealed calcification with or without tissue damage in 63.0% and tissue damage with or without calcification in 58.l%, in contrast with the observations of predominant tissue damage(76.8%) over calcification in Group I and of calcification(76.1%) over tissue damage in group II. Although dystrophic calcification has long and repeatedly dealt with patient's young age as a determinant of valve durability, such a characteristic evidence was not reached even in patients with calcified valves. Moreover, the prolonged explantation p riods from the studied on the previous report suggested strongly yet possibly evolving destructive processes among the valves in the remaining patients, and awaits further follow-up. In conclusion, PTF of the xenograft valves seems to result from more complicated biologic and metabolic reasons as well as more complex mecharical factors than the reported, and newer generation prostheses, with tissue preservation with glutaraldehyde, do not likely to provide decisive improvement in the occurrence of structural failurebioprostheses is generally limited to the highly aged.

  • PDF

A STUDY OF DENTAL CROWDING AND ITS RELATIONSHIP TO MANDIBULAR INCISOR SHAPE BY MODEL ANALYSIS IN ADOLESCENTS (청소년 석고 모형 분석에 의한 하악절치 형태와 치아밀집의 상관관계에 관한 연구)

  • Surh, Jeong-Eun;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.593-604
    • /
    • 1995
  • Mandibular incisor crowding is one of the most common features of malocclusion and is interesting characteristic in view of relapse and stability after orthodontic treatment. There are many potential factors in the etiology of lower anterior crowding. The tooth size variation is one of them, but biologic significance for the faciolingual width of the teeth has been overlooked. Peck and Peck reported that persons with ideal mandibular incisor alignment were shown to have incisor with smaller mesiodistal and larger faciolingual dimensions than persons with incisor crowding. On the basis of these findings they suggested MD/FL index as a clinical guideline for the assessment for lower incisor crowding. The present study was undertaken to examine the relationship between mandibular incisor crowding and mandibular incisor dimension, and determine their correlation with arch length discrepancy. 154 dental casts of people from 11 to 17 years of age were made, and were divided into normal group with irregularity index less than of 1, and crowding group with irregularity index greater than 1.The casts were measured and analyzed statistically. The results were as follows. 1. The mean mesiodistal width for mandibular incisor was larger in crowding group, and has significant difference in central inciosr measurement. There are no significant differences in the faciolingul width and MD/FL index. 2. Irregularity index has significant correlation coefficients with mesiodistal width and MD/FL index for mandibular incisor in crowding group, but no correlation with faciolingual width. It also has correlation with maxillary and mandibular arch length discrepancy, total tooth material, mandibular intercanine width, and mandibular inter first premolar width. 3. Upper and lower arch length discrepancy have significant correlation with mesiodistal width of mandibular incisor and overbite, but have no correlation with faciolingual width. Lower arch lenth discrepancy has significant correlation with MD/FL index for mandibular incisor and upper arch length discrepancy has correlation with MD/FL index for mandibular lateral incisor. 4. Significant differences were observed between normal and crowding group for the mandibular arch length discrepancy and overbite.

  • PDF

Correlation among Ownership of Home Appliances Using Multivariate Probit Model (다변량 프로빗 모형을 이용한 가전제품 구매의 상관관계 분석)

  • Kim, Chang-Seob;Shin, Jung-Woo;Lee, Mi-Suk;Lee, Jong-Su
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.2
    • /
    • pp.17-26
    • /
    • 2009
  • As the lifestyle of consumers changes and the need for various products increases, new products are being developed in the market. Each household owns various home appliances which are purchased through the choice of a decision maker. These appliances include not only large-sized products such as TV, refrigerator, and washing machine, but also small-sized products such as microwave oven and air cleaner. There exists latent correlation among possession of home appliances, even though they are purchased independently. The purpose of this research is to analyze the effect of demographic factors on the purchase and possession of each home appliances, and to derive some relationships among various appliances. To achieve this purpose, the present status on the possession of each home appliances are investigated through consumer survey data on the electric and energy product. And a multivariate probit(MVP) model is applied for the empirical analysis. From the estimation results, some appliances show a substitutive or complementary pattern as expected, while others which look apparently unrelated have correlation by co-incidence. This research has several advantages compared to previous literatures on home appliances. First, this research focuses on the various products which are purchased by each household, while previous researches such as Matsukawa and Ito(1998) and Yoon(2007) focus just on a particular product. Second, the methodology of this research can consider a choice process of each product and correlation among products simultaneously. Lastly, this research can analyze not only a substitutive or complementary relationship in the same category, but also the correlation among products in the different categories. As the data on the possession of home appliances in each household has a characteristic of multiple choice, not a single choice, a MVP model are used for the empirical analysis. A MVP model is derived from a random utility model, and has an advantage compared to a multinomial logit model in that correlation among error terms can be derive(Manchanda et al., 1999; Edwards and Allenby, 2003). It is assumed that the error term has a normal distribution with zero mean and variance-covariance matrix ${\Omega}$. Hence, the sign and value of correlation coefficients means the relationship between two alternatives(Manchanda et al., 1999). This research uses the data of 'TEMEP Household ICT/Energy Survey (THIES) 2008' which is conducted by Technology Management, Economics and Policy Program in Seoul National University. The empirical analysis of this research is accomplished in two steps. First, a MVP model with demographic variables is estimated to analyze the effect of the characteristics of household on the purchase of each home appliances. In this research, some variables such as education level, region, size of family, average income, type of house are considered. Second, a MVP model excluding demographic variables is estimated to analyze the correlation among each home appliances. According to the estimation results of variance-covariance matrix, each households tend to own some appliances such as washing machine-refrigerator-cleaner-microwave oven, and air conditioner-dish washer-washing machine and so on. On the other hand, several products such as analog braun tube TV-digital braun tube TV and desktop PC-portable PC show a substitutive pattern. Lastly, the correlation map of home appliances are derived using multi-dimensional scaling(MDS) method based on the result of variance-covariance matrix. This research can provide significant implications for the firm's marketing strategies such as bundling, pricing, display and so on. In addition, this research can provide significant information for the development of convergence products and related technologies. A convergence product can decrease its market uncertainty, if two products which consumers tend to purchase together are integrated into it. The results of this research are more meaningful because it is based on the possession status of each household through the survey data.

  • PDF

Role of Endoscopic Ultrasonography in the Diagnosis of Gastrointestinal Stromal Tumors in the Stomach (위의 위장관 간질성 종양에 대한 내시경 초음파의 진단적 역할)

  • Yoon, Ji-Hoon;Kim, Hyun-Chul;Choi, Chang-Soo;Oh, Sang-Hoon;Choi, Young-Kil
    • Journal of Gastric Cancer
    • /
    • v.5 no.2
    • /
    • pp.120-126
    • /
    • 2005
  • Purpose: Endoscopic ultrasonography (EUS) is a useful imaging procedure for the diagnosis of submucosal tumors in the stomach. The present study investigated the EUS features of benign and malignant gastrointestinal stromal tumors(GISTs) and assessed differences between the two groups. Materials and Methods: Thirty patients with a GIST in the stomach were included in the study (23 benign and 7 malignant GISTs). We compared characteristic EUS findings (tumor size, location of tumor, regularity of the outer margin, echoheterogeneity, presence of cystic spaces, echogenic foci and mucosal ulceration) between benign and malignant GISTs. Results: Tumor sizes over 40 mm were observed in $85.7\%$ of the malignant and $8.7\%$ of the benign tumors (P=0.000). Intralesional cystic spaces were noted in $71.4\%$ of the malignant and $8.7\%$ of the benign tumors (P=0.003). The outer margin was irregular in $71.4\%$ of the malignant and $8.7\%$ of the benign tumors (P=0.014). $85.7\%$ of the malignant and $13.0\%$ of the benign tumors had an echo-heterogeneity in the tumor (P=0.001). The locations of tumor and the presence of echogenic foci or mucosal ulcerations were not different between the two groups. Conclusion: Tumor sizes over 40 mm, intralesional cystic spaces, irregular outer margins, and echo-heterogeneity in the tumor were significantly more frequent in malignant GISTs. EUS can provide informations in differentiating benign from malignant GISTs.

  • PDF

Preoperative Detection of Hepatic Metastases from the colorectal Cancers: Comparison of Dual-phase CT scan, Mn-DPDP enhanced MRI, and combination of CT and MRI (대장암의 간 전이 진단: 이중시기 CT, Mn-DPDP 조영증강 MRI, 그리고 CT-MRI 종합 판독의 비교)

  • Shin, Kyung-Min;Kim, Jong-Yeol;Choi, Gyu-Seok;Kim, Hye-Jeong;Lee, Jong-Min;Chang, Yong-Min;Kim, Yong-Seon;Kang, Duk-Sik;Ryeom, Hun-Kyu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • Purpose : To determine the usefulness of additional Mn-DPDP MRI for preoperative evaluation of the patients with colorectal cancers by comparison of dual-phase CT scan, Mn-DPDP enhanced MRI and combination of CT and MRI. Materials and Methods : Fifty-three colorectal cancer patients with 92 metastatic nodules underwent dualphase (arterial and portal) helical CT scan and Mn-DPDP MRI prior to surgery. The indication of MRI was presence or suspected of having metastatic lesions at CT scan and/or increased serum carcinoembryonic antigen (CEA) levels (10 ng/mL or more). The diagnosis was established by the combination of findings at surgery, intraoperative ultrasonography, and histopathologic examination. Two radiologists interpreted CT, MRI, and combination of CT-MRI at discrete sessions and evaluated each lesion for location, size, and intrinsic characteristics. The lesions were divided into three groups according to their diameter; 1cm<, 1-2 cm, and >2 cm. Diagnostic accuracy was evaluated using the alternative-free response receiver operating characteristic method. Detection and false positive rate were also evaluated. Results : In the lesions smaller than 1 cm, detection rate of combined CT-MRI was superior to CT or MRI alone (82%, p=0.036). The mean accuracy (Az values) of combined CT and MRI was significantly higher than that of CT in the lesions smaller than 2 cm (1 cm<, p=0.034; 1-2 cm, p=0.045). However, there was no significant difference between MRI and combined CT-MRI. The false positive rate of CT was higher than those of combined CT-MR in the lesions smaller than 1 cm (28%, p=0.023). Conclusion : Additional MRI using Mn-DPDP besides routine CT scan was helpful in differentiating the hepatic lesions (<2 cm) and could improve detection of the small hepatic metastases (<1 cm) from colorectal carcinoma.

  • PDF

The Heterogeneity of Flow Distribution and Partition Coefficient in [15O-H2O] Myocardium Positron Emission Tomography ([15O-H2O] 심근 양전자 단층 촬영에서 혈류 분포의 비균일성과 분배계수)

  • Ahn, Ji Young;Lee, Dong Soo;Kim, Kyung Min;Jeong, Jae Min;Chung, June-Key;Shin, Seung-Ae;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.32-49
    • /
    • 1998
  • For estimation of regional myocardial blood flow with O-15 water PET, a few modifications considering partial volume effect based on single compartment model have been proposed. In this study, we attempted to quantify the degree of heterogeneity and to show the effect of tissue flow heterogeneity on partition coefficient(${\lambda}$) and to find the relation between perfusable tissue index(PTI) and ${\lambda}$ by computer simulation using two modified models. We simulated tissue curves for the regions with homogeneous and heterogeneous blood flow over a various flow range(0.2-4.0ml/g/min). Simulated heterogeneous tissue composed of 4 subregions of the same or different size of block which have different homogeneous flow and different degree of slope of distribution of blood flow. We measured the index representing heterogeneity of distribution of blood flow for each heterogeneous tissue by the constitution heterogeneity(CH). For model I, we assumed that tissue recovery coefficient ($F_{MME}$) was the product of partial volume effect($F_{MMF}$) and PTI. Using model I, PTI, flow, and $F_{MM}$ were estimated. For model II, we assumed that partition coefficient was another variable which could represent tissue characteristics of heterogeneity of flow distribution. Using model II, PTI, flow and ${\lambda}$ were estimated. For the simulated tissue with homogeneous flow, both models gave exactly the same estimates, of three parameters. For the simulated tissue with heterogeneous flow distribution, in model I, flow and $F_{MM}$ were correctly estimated as CH was increased moderately. In model II, flow and ${\lambda}$ were decreased curvi-linearly as CH was increased. The degree of underestimation of ${\lambda}$ obtained using model II, was correlated with CH. The degree of underestimation of flow was dependent on the degree of underestimation of ${\lambda}$. PTI was somewhat overestimated and did not change according to CH. We conclude that estimated ${\lambda}$ reflect the degree of tissue heterogeneity of flow distribution. We could use the degree of underestimation of ${\lambda}$ to find the characteristic heterogeneity of tissue flow and use ${\lambda}$ to recover the underestimated flow.

  • PDF

Comparative Morphology of Eggs of Heterophyids and Clonorchis sinensis Causing Human Infections in Korea (한국의 인체기대 이형흡충류 및 간흡충 충란의 비교형태학적 검토)

  • 이순형;황순욱채종일서병설
    • Parasites, Hosts and Diseases
    • /
    • v.22 no.2
    • /
    • pp.171-180
    • /
    • 1984
  • In order to provide some clues for differential diagnosis of trematode infections in fecal examination, the comparative morphology of eggs of 5 kinds of heterophyid flukes (Metagonimus yokogawai, Heterophyes heterophyes nocens, Heterophyopsis continua, Stellantchasmus falcatus and Pygidiopsis summa) and Clonorchis sinensis was studied. The eggs were obtained from distal portion of uteri of worms which were recovered from men after treatment. The characteristic shape and appearance of each kind of eggs were observed in detail under light microscope, and their length and width measured and compared one another. The results are as follows: 1. Eggs of C. sinensis are elongated ovoidal in shape with attenuated anterior end, 25.3~33. 2 (28. 3 in average) ${\mu}m$ long and 14.2~17.4(5.9) ${\mu}m$ wide with length/width ratio of 1.60~2.00 (1.78). They differ from all heterophyid eggs in that they have prominent wrinkling (muskmelon pattern) at their shell surface. 2. P. summa eggs are ovoid to pyriform in shape and characterized by the smallest size of all kinds examined, 19.8~22.9 (21.6) ${\mu}m$ long and 11.1~13.4 (12.1) ${\mu}m$ wide and the ratio 1.63~1.99 (1.78). 3. Eggs of S. falcatus are elongated ovoidal and most slender form, 25.3~29.2 (27.2) ${\mu}m$ long and 11.1~13.4 (12.5) ${\mu}m$ wide with the ratio of 2.00~2.57 (2.17). 4. Eggs of M. yokogawai are ellipsoid to elliptical in shape with round both ends, 26.9~31.6 (28.5) ${\mu}m$ long and 14.2~18.2 (16.8)${\mu}m$ wide with the ratio of 1.48~2.11 (1.70). 5. H. continua eggs are oval in shape, sometimes similar to M. yokogawai or H. h. nocen$ eggs, however, the relative breadth is broadest among all kinds, with maximum width at posterior half portion. They are 23.7~27.7 (25.0) ${\mu}m$ long, 15.8~18.9 (16.4) ${\mu}m$ wide with the ratio of 1. 33~1.75 (1.53). 6. Eggs of H. h. nocens are ellipsoid to ovoid in shape but sometimes more slender than M. yokogawai and have slightly pointed both ends. They are 23.7~29.2 (25.7) p.m long, 14.2~15.8 (15.4) ${\mu}m$ wide, and the ratio 1.50~2.06 (1.67). From the results, it is concluded that eggs, of 5 kinds of heterophyids and C. sinensis can be morphologically differentiated one another, however, careful observation and measurement on sufficient number of eggs are needed.

  • PDF