• Title/Summary/Keyword: channel frequency response

Search Result 187, Processing Time 0.029 seconds

A CP Detection Based SSS Detection Method for Initial Cell Search in 3GPP LTE FDD/TDD Dual Mode Downlink Receiver (3GPP LTE FDD/TDD 듀얼 모드 하향링크 수신기에서 초기 셀 탐색을 위한 CP 검출 기반의 SSS 검출 기법)

  • Kim, Jung-In;Jang, Jun-Hee;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.113-122
    • /
    • 2010
  • In this paper, we propose a CP (Cyclic Prefix) detection based SSS (Secondary Synchronization Signal) detection method for initial cell search in 3GPP LTE (3rd Generation Partnership Project Long Term Evolution) FDD/TDD (Frequency Division Duplex/Time Division Duplex) dual mode downlink receiver. In general, a blind coherent SSS detection method which can detect SSS without CP detection is applied. However, coherent detection method caused performance degradation by channel compensation error at high speed environment because it uses estimated CFR (Channel Frequency Response) at PSS (Primary Synchronization Signal), and it can be more serious problem in TDD mode due to increased distance between PSS and SSS. Also blind detectionhas the drawback of high computational complexity. Therefore, we proposed a CP type pre-decision structure with non-coherent SSS detection which has stable operation in high speed channel environments for 3GPP LTE TDD mode as well as FDD mode, and can reduce computational complexity by applying CP detection before SSS detection. Simulation results show that the proposed method has stable operation for 3GPP LTE TDD/FDD dual mode downlink receiver in various channel environments.

Serially multiplexed FBG accelerometer for structural health monitoring of bridges

  • Talebinejad, I.;Fischer, C.;Ansari, F.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.345-355
    • /
    • 2009
  • This article describes the development of a fiber optic accelerometer based on Fiber Bragg Gratings (FBG). The accelerometer utilizes the stiffness of the optical fiber and a lumped mass in the design. Acceleration is measured by the FBG in response to the vibration of the fiber optic mass system. The wavelength shift of FBG is proportional to the change in acceleration, and the gauge factor pertains to the shift in wavelength as a function of acceleration. Low frequency version of the accelerometer was developed for applications in monitoring bridges. The accelerometer was first evaluated in laboratory settings and then employed in a demonstration project for condition assessment of a bridge. Laboratory experiments involved evaluation of the sensitivity and resolution of measurements under a series of low frequency low amplitude conditions. The main feature of this accelerometer is single channel multiplexing capability rendering the system highly practical for application in condition assessment of bridges. This feature of the accelerometer was evaluated by using the system during ambient vibration tests of a bridge. The Frequency Domain Decomposition method was employed to identify the mode shapes and natural frequencies of the bridge. Results were compared with the data acquired from the conventional accelerometers.

Experimental investigation on flow field around a flapping plate with single degree of freedom

  • Hanyu Wang;Chuan Lu;Wenhai Qu;Jinbiao Xiong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.1999-2010
    • /
    • 2023
  • Undesirable flapping motion of discs can cause the failure of swing check valves in nuclear passive safety systems. Time-resolved particle image velocimetry (PIV) was employed to investigate the flow characteristics around a free-to-rotate plate and the motion response, with the Reynolds numbers, based on the hydraulic diameter of the channel, from 1.32 × 104 to 3.95 × 104. Appreciable flapping motion (±3.52°) appeared at the Reynolds number of 2.6 × 104 with the frequency of 5.08 Hz. In the low-Reynolds-number case, the plate showed negligible flapping. In the high-Reynolds-number case, the deflection angle increased with reduced flapping amplitude. The torque from the fluid determined the flapping amplitude. In the low-Reynolds-number case, Karman vortices were absent. With increasing Reynolds numbers, Karman vortices developed behind the plate with larger deflection angles. Strong interaction between the wake flow from the leading and trailing edge of the plate was observed. Based on power spectrum density (PSD) analysis, the vortex shedding frequency coincided with the flapping frequency, and the amplitude was positively correlated to the strength of the vortices. Proper orthogonal decomposition (POD) modes evince that, in the case of appreciable motion, coherent structures exhibited a larger spatial scale, enhancing the magnitude of the external torque on the plate.

Research on Channel Estimation Method in the modified ATSC system Using PN-Sequence for the Terrestrial 3D-TV broadcasting (지상파 3D-HDTV 전송을 위한 수정된 ATSC 전송 시스템에서 PN구조를 이용한 채널 추정 기법에 관한 연구)

  • Han, Jae-Shin;Ham, Na-Rye;Kim, Jung-Ho;Oh, Jong-Gyu;Kim, Joon-Tae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.63-66
    • /
    • 2010
  • 본 논문은 차세데 3D-TV 방송을 위해 수정된 ATSC (Modified Advanced Television Systems Committee) 시스템 [1]에서 파일럿 (Pilot)을 이용한 채널 추정 대신, PN 시퀀스 (Pseudo-Noise Sequence)를 이용한 채널 추정 방식의 문제점에 대하여 2가지 방법으로 연구하였다. PN 시퀀스를 이용하여 채널을 추정하는 TDS-OFDM (Time Domain Synchronous - Orthogonal Frequency Division Multiplexing)시스템은 QAM (Quadrature Amplitude Modulation) 변조 방식을 사용하기 때문에 수신측 PN 시퀀스의 위상 변화가 일어나지 않는다. 하지만 수정된 ATSC 시스템에서 사용하는 VSB (Vestigial Side Band)변조 방식에서 직교위상 (Quadrature) 채널을 통해 전송되는 값은 동위상 (In-Phase) 채널을 통해 전송되는 값의 단순한 힐버트 변환 (Hilbert Transform)에 의해 생성되어 불규칙한 위상 변화가 발생한다. 따라서 수정된 ATSC 시스템에서 채널 추정을 위해 PN 시퀀스를 사용하게 된다면 상관 (Correlation) 특성을 잃어버릴 것이며 올바른 채널 임펄스 응답 (Channel Impulse Response)을 얻을 수 없다.

  • PDF

Development of a Linear Stability Analysis Model for Vertical Boiling Channels Connecting with Unheated Risers

  • Hwang, Dae-Hyun;Yoo, Yeon-Jong;Zee, Seong-Quun
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.572-585
    • /
    • 1999
  • The characteristics of two-phase flow instability in a vertical boiling channel connecting with an unheated riser are investigated through the linear stability analysis model. Various two-phase flow models, including thermal non-equilibrium effects, are taken into account for establishing a physical model in the time domain. A classical approach to the frequency response method is adopted for the stability analysis by employing the D-partition method. The adequacy of the linear model is verified by evaluating experimental data at high quality conditions. It reveals that the flow-pattern-dependent drift velocity model enhances the prediction accuracy while the homogeneous equilibrium model shows the most conservative predictions. The characteristics of density wave oscillations under low-power and low-quality conditions are investigated by devising a simple model which accounts for the gravitational and frictional pressure losses along the channel. The necessary conditions for the occurrences of type-I instability and flow excursion are deduced from the one-dimensional D-partition analysis. The parametric effects of some design variables on low quality oscillations are also investigated.

  • PDF

Design of a Digital Signal Processing System for Analysis of Tendon Reflex Response (T-반사 응답의 분석을 위한 디지탈 신호 처리 시스템의 설계)

  • 김재국;권도철
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.221-226
    • /
    • 1996
  • Tendon reflex responses generated from mechanical stimulus had been studied for quantitative analysis of activity of tendon reflex, especially patellar tendon reflex responses are known to be a criterion for diagnosing the L3 or L4 radiculopathy. In this paper, we developed a digital signal processing system for analysis of the tendon reflex response. The system parameter, i.e., $\textit{sampling frequency, pre-amplification gain, input channel and filter bank}$ are selected by Using software switches. From the view points of flexibility, the system hardware is connected to an IBM PC for analyzing the tendon reflex parameters, amplitude, latency duration We applied the proposed system to the analysis of the patellar tendon reflex reponses. In the experiment, we measured latency, duration, amplitude of the reflex action potentials generated from vastus medialis, vastus lateralis and rectus femoris that compose quadriceps, and the measured data are analyzed througll the ANOVA test which has 5% significant level. As a result, we showed that the mean amplitude of reflex action potential at the vastus lateralis is larger than any other muscle and the mean latency of the reflex action potential at the rectus femoris is shorter than any other muscle.

  • PDF

Modified droop control scheme for load sharing amongst inverters in a micro grid

  • Patel, Urvi N.;Gondalia, Dipakkumar;Patel, Hiren H.
    • Advances in Energy Research
    • /
    • v.3 no.2
    • /
    • pp.81-95
    • /
    • 2015
  • Microgrid, which can be considered as an integration of various dispersed resources (DRs), is characterized by number of DRs interfaced through the power electronics converters. The microgrid comprising these DRs is often operated in an islanded mode. To minimize the cost, reduce complexity and increase reliability, it is preferred to avoid any communication channel between them. Consequently, the droop control method is traditionally adopted to distribute active and reactive power among the DRs operating in parallel. However, the accuracy of distribution of active and reactive power among the DRs controlled by the conventional droop control approach is highly dependent on the value of line impedance, R/X i.e., resistance to reactance ratio of the line, voltage setting of inverters etc. The limitations of the conventional droop control approach are demonstrated and a modified droop control approach to reduce the effect of impedance mis-match and improve the time response is proposed. The error in reactive power sharing is minimized by inserting virtual impedance in line with the inverters to remove the mis-match in impedance. The improved time response is achieved by modifying the real-power frequency droop using arctan function. Simulations results are presented to validate the effectiveness of the control approach.

Performance evaluation of smart prefabricated concrete elements

  • Zonta, Daniele;Pozzi, Matteo;Bursi, Oreste S.
    • Smart Structures and Systems
    • /
    • v.3 no.4
    • /
    • pp.475-494
    • /
    • 2007
  • This paper deals with the development of an innovative distributed construction system based on smart prefabricated concrete elements for the real-time condition assessment of civil infrastructure. So far, two reduced-scale prototypes have been produced, each consisting of a $0.2{\times}0.3{\times}5.6$ m RC beam specifically designed for permanent instrumentation with 8 long-gauge Fiber Optic Sensors (FOS) at the lower edge. The sensing system is Fiber Bragg Grating (FBG)-based and can measure finite displacements both static and dynamic with a sample frequency of 625 Hz per channel. The performance of the system underwent validation in the laboratory. The scope of the experiment was to correlate changes in the dynamic response of the beams with different damage scenarios, using a direct modal strain approach. Each specimen was dynamically characterized in the undamaged state and in various damage conditions, simulating different cracking levels and recurrent deterioration scenarios, including cover spalling and corrosion of the reinforcement. The location and the extent of damage are evaluated by calculating damage indices which take account of changes in frequency and in strain-mode-shapes. The outcomes of the experiment demonstrate how the damage distribution detected by the system is fully compatible with the damage extent appraised by inspection.

Time- and Frequency-Domain Optimization of Sparse Multisine Coefficients for Nonlinear Amplifier Characterization

  • Park, Youngcheol;Yoon, Hoijin
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.1
    • /
    • pp.53-58
    • /
    • 2015
  • For the testing of nonlinear power amplifiers, this paper suggests an approach to design optimized multisine signals that could be substituted for the original modulated signal. In the design of multisines, complex coefficients should be determined to mimic the target signal as much as possible, but very few methods have been adopted as general solutions to the coefficients. Furthermore, no solid method for the phase of coefficients has been proven to show the best resemblance to the original. Therefore, in order to determine the phase of multisine coefficients, a time-domain nonlinear optimization method is suggested. A frequency-domain-method based on the spectral response of the target signal is also suggested for the magnitude of the coefficients. For the verification, multisine signals are designed to emulate the LTE downlink signal of 10 MHz bandwidth and are used to test a nonlinear amplifier at 1.9 GHz. The suggested phase-optimized multisine had a lower normalized error by 0.163 dB when N = 100, and the measurement results showed that the suggested multisine achieved more accurate adjacent-channel leakage ratio (ACLR) estimation by as much as 12 dB compared to that of the conventional iterative method.

A Study on Tracking Control for Networked Multi-Motor Systems

  • Lee, Hong-Hee;Jung, Eui-Heon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1897-1900
    • /
    • 2004
  • In recent years, a lot of industrial equipments have serial communication channel such as FieldBus (CAN, Profibus, etc.) or Ethernet that provides real time communication between industrial equipments. Theses applications include gantry crane, robot, chip mounter, etc.. In this paper, we discuss the synchronization technique for networked multi-motor systems where controllers (commercial servo amps) are distributed and interconnected by CAN (Controller Area Networks). We first describe the equivalent model for the individual servo-amp and motor using the frequency response. We design the $H{\infty}$ controller for motion synchronization. Finally, the synchronization technique using the equivalent model and the $H{\infty}$ controller is verified by the simulation and the experiment.

  • PDF