• Title/Summary/Keyword: channel connector

검색결과 28건 처리시간 0.021초

RT 기술을 이용한 사출금형의 3 차원 냉각 채널 구현 (Implementation of 3-Dimensional Cooling Channel in Injection Mold Using RT Technology)

  • 김종덕;홍석관;이경환;김미애;이대근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.199-200
    • /
    • 2006
  • It will not be an exaggeration to say that one of the most important features of RT (Rapid Tooling) technology is to easy manufacturing complex shape of cooling channel in injection mold. That is, RT technology is hardly influenced complex shape of tool, Therefore, mold designer can optimize the position and shape of cooling channel whatever they want. In this study, we optimized cooling channel through CAE analysis to solve the problem; prototype-connector-mold applied conventional cooling channel, locally warped by internal stress: The effect of three-dimensional cooling channel was supported by simulation result. But it is impossible to produce injection mold applied three-dimensional cooling channel through machining operation. Therefore, we produced the prototype-connector-mold with three-dimensional cooling channel using Direct Metal Laser Sintering (DMLS) process, and get good-quality prototype-connector without warpage.

  • PDF

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

Push out tests on various shear connectors used for cold-formed steel composite beam

  • Rajendran, Senthilkumar;Perumalsamya, Jayabalan;Mohanraj, Divya
    • Steel and Composite Structures
    • /
    • 제42권3호
    • /
    • pp.315-323
    • /
    • 2022
  • Shear connectors are key elements that ensure integrity in a composite system. The primary purpose of a shear connector is to bring a high degree of interaction between composite elements. A wide variety of connectors are available for hot-rolled composite construction, connected to the beam through welding. However, with cold-formed members being very thin, welding of shear connectors is not desirable in cold-formed composite constructions. Shear connectors for cold-formed elements are limited in studies as well as in the market. Hence in this study, three different types of shear connectors, namely, single-channel, double channel, and self-tapping screw, were considered, and their performance assessed by the Push-out test as per Eurocode 4. The connection between channel shear connectors and the beam was made using self-tapping screws to avoid welding. The performance of the connectors was analyzed based on their ultimate capacity, characteristic capacity, ductility, and slippage during loading. Strength to weight ratio was also carried out to understand the proposed connectors' suitability for conventional ones. The results showed relatively higher initial stiffness and ductility for double channel connectors than other connectors. Also, self-tapping screws had a higher strength to weight ratio with low ductility.

개방형 유공강판 전단연결재로 보강된 강관말뚝머리의 휨거동에 관한 유한요소 해석 (Finite Element Analysis for Bending Performance of Steel Pipe Pile Cap with the Open Perforated Shear Connector)

  • 김영호;강재윤;유승운
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.4018-4023
    • /
    • 2010
  • 합성구조에서 강재와 콘크리트 사이의 경계면에 효과적인 응력전달과 합성거동을 유도하기 위하여 스터드, 채널, 유공강판 등이 사용된다. 많은 연구자들이 여러 종류의 전단연결재의 특성을 개선시키기 위해 많은 노력을 기울이고 있다. 본 연구에서는 말뚝구조물과 확대기초와의 합성을 위해 개방형 유공강판 전단연결재로 보강된 강관 말뚝머리의 휨거동을 분석하였다. 개방형 유공강판 전단연결재로 보강된 강관말뚝의 휨거동을 규명하고, 다양한 변수해석에서 요구되는 정보를 얻고자 유한요소해석 프로그램인 ABAQUS를 사용하여 비선형 유한요소 해석을 수행하였다.

Investigation of pipe shear connectors using push out test

  • Nasrollahi, Saeed;Maleki, Shervin;Shariati, Mahdi;Marto, Aminaton;Khorami, Majid
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.537-543
    • /
    • 2018
  • Mechanical shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface in composite beams. Steel pipe as a new shear connector is proposed in this research and its performance to achieve composite strength is investigated. Experimental monotonic push-out tests were carried out for this connector. Then, a nonlinear finite element model of the push-out specimens is developed and verified against test results. Further, the finite element model is used to investigate the effects of pipe thickness, length and diameter on the shear strength of the connectors. The ultimate strengths of these connectors are reported and their respective failure modes are discussed. This paper comprises of the push-out tests of ten specimens on this shear connector in both the vertical and horizontal positions in different reinforced concretes. The results of experimental tests are given as load-deformation plots. It is concluded that the use of these connectors is very effective and economical in the medium shear demand range of 150-350 KN. The dominant failure modes observed were either failure of concrete block (crushing and splitting) or shear failure of pipe connector. It is shown that the horizontal pipe is not as effective as vertical pipe shear connector and is not recommended for practical use. It is shown that pipe connectors are more effective in transferring shear forces than channel and stud connectors. Moreover, based on the parametric study, a formula is presented to predict the pipe shear connectors' capacity.

비대칭 연결재를 갖는 조립식 압축부재의 좌굴 거동에 관한 실험 연구 II - 연결재 종류의 영향 - (An Experimental Study of Buckling Behavior in Built-up Compression Member with Unsymmetric Connectors II - Effect of Type of Connection Members -)

  • 강상훈;한만엽;조병두
    • 대한토목학회논문집
    • /
    • 제32권4A호
    • /
    • pp.217-225
    • /
    • 2012
  • 본 연구에서는 비대칭 연결재를 갖는 조립식 압축부재의 연결재 종류에 따른 좌굴 거동을 알아보기 위한 실 대형 실험을 실시하였다. 압축부재인 H-300 형강 10 m 부재 3개를 볼트 연결하여 총 길이 30 m가 되도록 2 m 간격으로 2열 배치한 후 연결재 종류가 띠판, ㄷ형강, 복 ㄷ형강인 경우에 대하여 압축 실험을 실시하였다. 본 논문에서는 연결재 종류에 따른 실험 좌굴 하중을 평가하고 이를 유한요소해석 결과인 좌굴하중과 Timoshenko 식에 의한 좌굴하중과 비교 분석 하였으며, 연결재 종류에 따른 조립식 압축부재의 좌굴 거동으로 인한 종방향 변위, 횡방향 변위, 변형률 등을 분석하였다. 실험 결과 비대칭 연결재를 갖는 조립식 압축부재의 연결재가 띠판일 때 보다 복 ㄷ형강일 때의 좌굴 하중은 4.2%, ㄷ형강일 때는 36.6% 감소하는 것으로 나타났다.

Application of Extreme Learning Machine (ELM) and Genetic Programming (GP) to design steel-concrete composite floor systems at elevated temperatures

  • Shariati, Mahdi;Mafipour, Mohammad Saeed;Mehrabi, Peyman;Zandi, Yousef;Dehghani, Davoud;Bahadori, Alireza;Shariati, Ali;Trung, Nguyen Thoi;Salih, Musab N.A.;Poi-Ngian, Shek
    • Steel and Composite Structures
    • /
    • 제33권3호
    • /
    • pp.319-332
    • /
    • 2019
  • This study is aimed to predict the behaviour of channel shear connectors in composite floor systems at different temperatures. For this purpose, a soft computing approach is adopted. Two novel intelligence methods, including an Extreme Learning Machine (ELM) and a Genetic Programming (GP), are developed. In order to generate the required data for the intelligence methods, several push-out tests were conducted on various channel connectors at different temperatures. The dimension of the channel connectors, temperature, and slip are considered as the inputs of the models, and the strength of the connector is predicted as the output. Next, the performance of the ELM and GP is evaluated by developing an Artificial Neural Network (ANN). Finally, the performance of the ELM, GP, and ANN is compared with each other. Results show that ELM is capable of achieving superior performance indices in comparison with GP and ANN in the case of load prediction. Also, it is found that ELM is not only a very fast algorithm but also a more reliable model.

4G 이동통신기반 초간편 접속 고기능 광커넥터의 구현 (Implementation of Quick fit, High Performance Outdoor Optical Connector for 4G Mobile Communication System)

  • 이영철;김철균;천승창;정우연
    • 정보통신설비학회논문지
    • /
    • 제10권3호
    • /
    • pp.110-114
    • /
    • 2011
  • The recent development of 4G mobile communication system has led to the rapid technology shift from conventional repeater systems using coaxial cable links towards new fiber optic repeater systems using fiber-optic links between the base station and the outdoor fiber optic repeater. The technical changes have brought up the increasing needs of robust optic links that can be used in harsh environments. Based on the most demanding requirements, a new outdoor optical connector employing 2-channel fiber optics, uplink and downlink, has been developed for the applications where the rugged environmental protection is essential. This paper describes the development of the new connector along with the design criteria and performance results. In summarizing, the prototype optical connectors have undergone extensive laboratory and field test, and they have shown exceptional optical and mechanical characteristics under extreme environmental conditions. The connectors have also exhibited capabilities of providing fast and easy installation while maintaining high performance fiber optic connections.

  • PDF

전단구속철근을 배치한 유공강판 전단연결재에 관한 실험적 연구 (An Experimental Study on the Behavior of the Perforated Rib Connector with Shearing Bars)

  • 김성칠;김영호;유성근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권6호
    • /
    • pp.175-182
    • /
    • 2006
  • 강 콘크리트 합성구조에서 강재와 콘크리트 사이의 경계면에 효과적인 응력전달과 합성거동을 유도하기 위하여 스터드, 채널, 유공강판 등이 사용된다. 가장 광범위하게 사용하는 전단연결재는 스터드 형식이고, 최근에 들어서는 강판에 구멍을 뚫은 유공강판전단연결재인 Perfobond가 주목을 받고 있다. 본 연구는 강 콘크리트 합성교량에 적용하기 위한 Perfobond형 전단연결재의 연성능력과 전단성능을 향상시킬 목적으로 횡방향 전단구속철근을 배치하고, Push-out 실험을 수행하여 전단내력을 비교하였다. 실험결과, 유공강판 전단연결재에 전단구속철근, 횡방향 관통철근, 단부 지압판 등을 설치함에 따른 수평 저항성능이나 다웰효과 등에 의해 전단내력이 상승하였으며, 또한 최대내력 이후 변형능력이 유지되면서 연성거동 특성을 보였다.

Prediction of shear capacity of channel shear connectors using the ANFIS model

  • Toghroli, Ali;Mohammadhassani, Mohammad;Suhatril, Meldi;Shariati, Mahdi;Ibrahim, Zainah
    • Steel and Composite Structures
    • /
    • 제17권5호
    • /
    • pp.623-639
    • /
    • 2014
  • Due to recent advancements in the area of Artificial Intelligence (AI) and computational intelligence, the application of these technologies in the construction industry and structural analysis has been made feasible. With the use of the Adaptive-Network-based Fuzzy Inference System (ANFIS) as a modelling tool, this study aims at predicting the shear strength of channel shear connectors in steel concrete composite beam. A total of 1200 experimental data was collected, with the input data being achieved based on the results of the push-out test and the output data being the corresponding shear strength which were recorded at all loading stages. The results derived from the use of ANFIS and the classical linear regressions (LR) were then compared. The outcome shows that the use of ANFIS produces highly accurate, precise and satisfactory results as opposed to the LR.