• Title/Summary/Keyword: channel condition

Search Result 1,176, Processing Time 0.028 seconds

Numerical Modeling of the Mathematical Model of Single Spherical Bubble (단일 구형 기포의 수학적 모델에 대한 수치적 해석 모델)

  • Kang, Dong-Keun;Yang, Hyun-Ik
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.731-738
    • /
    • 2010
  • Cavitation is described by formation and collapse of the bubbles in a liquid when the ambient pressure decreases. Formed bubbles grow and collapse by change of pressure, and when they collapse, shockwave by high pressure is generated. In general, bubble behavior can be described by Rayleigh-Plesset equation under adiabatic or isothermal condition and hence, phase shift by the pressure change in a bubble cannot be considered in the equation. In our study, a numerical model is developed from the mathematical model considering the phase shift from the previous study. In the developed numerical model, size of single spherical bubble is calculated by the change of mass calculated from the change of the ambient pressure in a liquid. The developed numerical model is verified by a case of liquid flow in a narrow channel.

Effects of Swirl Flow Generated by Twisted Tape on Beat Transfer and Friction Factor in a Square Channel (사각 채널에서 테이프에 의한 스월유동이 열전달과 마찰계수에 미치는 효과)

  • Ahn, Soo-Whan;Kang, Ho-Keun;Putra, Ary Bachtiar Krishna
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.11
    • /
    • pp.912-917
    • /
    • 2007
  • Regionally averaged heat transfer distributions and friction factors in square channels with twisted tape inserts and with twisted tape inserts plus interrupted ribs are experimentally investigated. The effects of surface heating condition on heat transfer enhancement are also investigated. Each wall of the square channel is composed of isolated aluminum plates. The interrupted square ribs are arranged along the axial flow direction on the bottom wall only. Experimental tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The results are compared with those of previous investigations for circular tube with axial interrupted ribs and twisted tape inserts.

PIV Analysis on the Flows around a Cylinder under Rolling Wave (파랑상태에 있는 실린더 구조물 주위의 PIV유동 해석)

  • Jo, Hyo-Jae;Doh, Deog-Hee;Lee, Eon-Ju
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.3
    • /
    • pp.51-58
    • /
    • 2011
  • The purpose of the study is to provide a foundation in predicting a maximum wave force when the ocean structure is laid out under breaking wave. Experiments were conducted with a down-scaled cylindrical model installed in a wave generating water channel. Maximum wave slopes were changed in regular wave condition by the wave breaker in the water channel. Cylinder's diameters were changed to 0.1m and 0.05m, respectively. Using the PIV results qualitative analyses were performed based upon the previous knowledge.

Study on the Estimation of Discharge Coefficient of Sluice for Tidal Power Generation by Performing Physical Experiment (수리실험에 의한 조력발전용 수문의 유량계수 산정에 관한 고찰)

  • Oh, Sang-Ho;Lee, Kwang Soo;Lee, Dal Soo;Jang, Se-Chul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.160.1-160.1
    • /
    • 2011
  • In this study, the influence of methodology of assessing water levels on the discharge coefficient of sluice for tidal power generation was investigated. A physical experiment was performed in a planar open channel by installing 1/70 scale model of the sluice caisson in the planar open channel. In front of and behind the sluice model, sloping bathymetry was made to reproduce corresponding field condition. By analyzing the experimental results, it was found that the location of measuring water levels significantly affects the estimates of the discharge coefficient, due to the variability of the parameter according to the head difference between the measuring locations. Therefore, it is necessary to be careful in estimating and utilizing the discharge coefficient in the relevant study of a tidal power generation.

  • PDF

Flow Routing in Prismatic Symmetrical Compound Channels by Applications of the Apparent Shear Force (ASF)

  • Chun, Moo-Kap;Jee, Hong-Kee
    • Korean Journal of Hydrosciences
    • /
    • v.8
    • /
    • pp.41-56
    • /
    • 1997
  • A new routing computer model for the symmetric compound channel called the ASRMCS(Apparent Shear Force Muskingum-Cunge Method in Symmetry) has been developed. The Muskingum-Cunge routing method is adapted. The Apparent Shear Force (ASF) between the deep main channel and the shallow floodplan flow is introduced while the flow is routed. The nonlinear parameter method is applied. The temporal and spatial increments are varied according to the flow rate. The adaptation of above schemes is tested against the routed hydrographs using the DAMBRK model. The results of general routing practice of Muskingum-Cunge Method(GPMC) are also compared with those of above two models. The results of the new model match remarkably well with those of DAMBRK. The routed hydrographs show a smooth variation from the inflow boundary condition without any distortions caused by the difference of cross-section shape. However, the results of GPMC, showing early rise and fall of routed hydrograph, have considerable differences from those of the ASFMCS and DAMBRK.

  • PDF

Terminal-based Dynamic Clustering Algorithm in Multi-Cell Cellular System

  • Ni, Jiqing;Fei, Zesong;Xing, Chengwen;Zhao, Di;Kuang, Jingming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.9
    • /
    • pp.2086-2097
    • /
    • 2012
  • A terminal-based dynamic clustering algorithm is proposed in a multi-cell scenario, where the user could select the cooperative BSs from the predetermined static base stations (BSs) set based on dynamic channel condition. First, the user transmission rate is derived based on linear precoding and per-cell feedback scheme. Then, the dynamic clustering algorithm can be implemented based on two criteria: (a) the transmission rate should meet the user requirement for quality of service (QoS); (b) the rate increment exceeds the predetermined constant threshold. By adopting random vector quantization (RVQ), the optimized number of cooperative BSs and the corresponding channel conditions are presented respectively. Numerical results are given and show that the performance of the proposed method can improve the system resources utilization effectively.

Adaptive Forward Error Correction Scheme for Real-Time Communication in Satellite IP Networks

  • Cho, Sung-Rae
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.6
    • /
    • pp.1116-1132
    • /
    • 2010
  • In this paper, a new forward error correction (FEC) protocol is proposed for point-to-multipoint satellite links. Link-layer error control protocols in point-to-multipoint satellite links impose several problems such as unreliability and receiver-heterogeneity. To resolve the problem of heterogeneous error rates at different receivers, the proposed scheme exploits multiple multicast channels to which each receiver tunes. The more channels a receiver tunes to, the more powerful error correcting capability it achieves. Based on its own channel condition, each receiver tunes to as many channels as it needs, which prevents from receiving unwanted parities. Furthermore, each receiver saves the decoding time, processing overhead, and processing energy. Performance evaluation shows that the proposed scheme guarantees the target PER while saving energy. The proposed technique is highly adaptive to the channel variation with respect to the throughput efficiency, and provides scalable PER and throughput efficiency.

A Study on the Conjugate Heat Transfer from Horizontal Plate with Protruding Heat Source (열원이 부착된 수평 평판에서 복합 열전달에 관한 연구)

  • 김병철;주동인
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.512-518
    • /
    • 2002
  • The real chip and similarity model were used to investigate the thermal behavior and velocity distribution of air from the heat source with the location and the amount of heat experimentally and numerically, and compared. The heat generated in the block is not cooled by convection and show the high temperature by the stagnation of heat flow. After maintaining the high temperature of block by the natural convection, the sudden drop of temperature with the air flow was shown in the channel but the decreasing rate was small with the time. The inward block was effected by infinitesimal air flow generated between block and channel and outward block was effected by the entry condition.

A study on Manufacturing of Micro Dotting Pin (바이오용 마이크로 핀의 제작에 관한 연구)

  • Lee, Young-Soo;Km, Kwang-Soon;Kim, Byeong-Hee
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.21-27
    • /
    • 2003
  • The bio-micro pin is usually used for biochemistry analysis. The capability of manufacturing the micro-pin and array with effective and low-cost way is very important to developers. The micro-pin is composed of "sample channel" putting liquid into already fixed volume, "flat tip" having connection with printing quantity, and "head part" for preventing it from rotation of pin in the holder. We analyzed out printing variation in accordance with shape and tip size of the micro-pin point channel, In this study, we suggested the manufacturing progress and shape demand condition of the micro-pin which could put $0.2{\mu}{\ell}$-biochemistry material into the sample volume, and will be able to produce the micro-pin which can put $10n{\ell}$-biochemistry material into the sample volume in the future.

  • PDF

Temperature Measurements in a Microfluidic Chip with Polydiacetylene Sensor (폴리다이아세틸렌을 이용한 미세유동칩 내의 온도 측정)

  • Jang, Young-Sik;Ryu, Sung-Min;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2696-2699
    • /
    • 2008
  • Microfluidic chips have been frequently utilized to perform biochemical analysis, like cell culture, because they reduce the consumptions of analytes and reagents and automate multi-step analysis processes. It is often critical to monitor temperature in a microchannel for the analyses in order to control a reaction condition of bio or chemical molecules. We propose a novel method to monitor temperature of a microchannel flow by using polydiacetylene (PDA), a conjugated polymer, that has a unique property to transform its color from visible blue to fluorescent red by thermal stress. We inject PDA sensor droplets generated by hydrodynamic instability into a microchannel with a microheater incorporated on the channel bottom. Also, we change the channel temperature by providing the different electric power to the microheater. The results show that the florescence intensity of PDA sensor droplets linearly increases in response to the flow temperature increase within a certain range.

  • PDF