• Title/Summary/Keyword: changing point

Search Result 1,120, Processing Time 0.025 seconds

Impact of Call Setup Time on UPT Performance Based on AIN Platform

  • Baik, In-Kywan;Jo, Jun-Mo;Kim, Sung-Un;Jung, Sin-Il
    • Journal of Korea Multimedia Society
    • /
    • v.1 no.2
    • /
    • pp.249-255
    • /
    • 1998
  • This paper analyzes the impact of Call Setup Time on UPT performance based on the AIN platform. Call Setup Time is used as the performance parameter. In implementing UPT based on the AIN platform, the geographical location of VLR affects network performance. In order to find an optimum location of VLR among three different types of structures, i.e. VLR is located close to Service Switching Point and Cell Site Controller and located at Service Control Point, each Call Setup Time on proposed time delay model is calculated and compared. Network performance is analyzed by changing the number of STP in No.7 signaling network in UPT and the utilization ratio, $\rho$, for SSP, STP and SCP.

  • PDF

Implementation of View Point Tracking System for Outdoor Augmented Reality (옥외 증강현실을 위한 관측점 트래킹 시스템 구현)

  • Choi, Tae-Jong;Kim, Jung-Kuk;Huh, Woong;Jang, Byung-Tae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.4
    • /
    • pp.45-54
    • /
    • 2004
  • In this paper, a view point tracking system has been realized for outdoor augmented reality including broad area monitoring. Since the surroundings of the moving view point are changing, it is necessary to track the position and observation moment of the view point system for consistency between real and virtual images. For this reason, the GPS(Global Positioning System) is applied to the realized system for tracking the information on position and direction of the moving system. In addition, an optical position tracking system that is able to track view point in a limited area is used, because the local tracking system has to trace the image variation, seen to the observer in a moving vehicle, at a particular position and time. It was found that the realized outdoor augmented reality system, which combined the virtual information tracked in real time with the real image, can be very practical in various application area.

Searching an Efficient frontier in the DEA Model based on the Reference Point Method (참조점 방법을 이용한 DEA모형의 프론티어 탐구)

  • 오동일
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.83-90
    • /
    • 2000
  • DEA is a newly developed analyzing tool to measure efficiency evaluation of decision making units (DMU). It compares DMU by radial Projection on the efficient frontier. The purpose of this study is to show reference point approach used for searching solution in multiple objective linear Programming can be usefully used to determine flexible efficient frontier of each DMU In reference point approach, the minimization of ASF Produces an efficient points in frontier and enhances the usefulness of DEA by Providing flexibility in DEA and optimally allocating resources to DMU. Various DEA models can be supported by reference point method by changing the projection direction in order to choose the targets units, standards costs and management benching-marking.

  • PDF

The Alignment of Triangular Meshes Based on the Distance Feature Between the Centroid and Vertices (무게중심과 정점 간의 거리 특성을 이용한 삼각형 메쉬의 정렬)

  • Minjeong, Koo;Sanghun, Jeong;Ku-Jin, Kim
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.12
    • /
    • pp.525-530
    • /
    • 2022
  • Although the iterative closest point (ICP) algorithm has been widely used to align two point clouds, ICP tends to fail when the initial orientation of the two point clouds are significantly different. In this paper, when two triangular meshes A and B have significantly different initial orientations, we present an algorithm to align them. After obtaining weighted centroids for meshes A and B, respectively, vertices that are likely to correspond to each other between meshes are set as feature points using the distance from the centroid to the vertices. After rotating mesh B so that the feature points of A and B to be close each other, RMSD (root mean square deviation) is measured for the vertices of A and B. Aligned meshes are obtained by repeating the same process while changing the feature points until the RMSD is less than the reference value. Through experiments, we show that the proposed algorithm aligns the mesh even when the ICP and Go-ICP algorithms fail.

The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT (PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가)

  • Hong, Gun-Chul;Park, Sun-Myung;Jung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.172-176
    • /
    • 2010
  • Purpose: The patients' moves occurred at PET/CT scan will cause the decline of correctness in results by resulting in inconsistency of Attenuation Correction (AC) and effecting on quantitative evaluation. This study has evaluated the utility of reconstruction method using AC position changing method when having inconsistency of AC depending on the position change of emission scan after transmission scan in obtaining PET/CT 3D image. Materials and Methods: We created 1 mL syringe injection space up to ${\pm}2$, 6, 10 cm toward x and y axis based on central point of polystyrene ($20{\times}20110$ cm) into GE Discovery STE16 equipment. After projection of syringe with $^{18}F$-FDG 5 kBq/mL, made an emission by changing the position and obtained the image by using AC depending on the position change. Reconstruction method is an iteration reconstruction method and is applied two times of iteration and 20 of subset, and for every emission data, decay correction depending on time pass is applied. Also, after setting ROI to the position of syringe, compared %Difference (%D) at each position to radioactivity concentrations (kBq/mL) and central point. Results: Radioactivity concentrations of central point of emission scan is 2.30 kBq/mL and is indicated as 1.95, 1.82 and 1.75 kBq/mL, relatively for +x axis, as 2.07, 1.75 and 1.65 kBq/mL for -x axis, as 2.07, 1.87 and 1.90 kBq/mL for +y axis and as 2.17, 1.85 and 1.67 kBq/mL for -y axis. Also, %D is yield as 15, 20, 23% for +x axis, as 9, 23, 28% for -x axis, as 12, 21, 20% for +y axis and as 8, 22, 29% for -y axis. When using AC position changing method, it is indicated as 2.00, 1.95 and 1.80 kBq/mL, relatively for +x axis, as 2.25, 2.15 and 1.90 kBq/mL for -x axis, as 2.07, 1.90 and 1.90 kBq/mL for +y axis, and as 2.10, 2.02, and 1.72 kBq/mL for -y axis. Also, %D is yield as 13, 15, 21% for +x axis, as 2, 6, 17% for -x axis, as 9, 17, 17% for +y axis, and as 8, 12, 25% for -y axis. Conclusion: When in inconsistency of AC, radioactivity concentrations for using AC position changing method increased average of 0.14, 0.03 kBq/mL at x, y axis and %D was improved 6.1, 4.2%. Also, it is indicated that the more far from the central point and the further position from the central point under the features that spatial resolution is lowered, the higher in lowering of radioactivity concentrations. However, since in actual clinic, attenuation degree increases more, it is considered that when in inconsistency, such tolerance will be increased. Therefore, at the lesion of the part where AC is not inconsistent, the tolerance of radioactivity concentrations will be reduced by applying AC position changing method.

  • PDF

On Flexibility in Architecture Focused on the Contradiction in Designing Flexible Space and Its Design Proposition

  • Kim, Young-Ju
    • Architectural research
    • /
    • v.15 no.4
    • /
    • pp.191-200
    • /
    • 2013
  • Since Modern Movement flexibility has been one of the most attractive words in architecture. However, "overprovision first, division later" has been the most prevailing design method for spatial flexibility, and many of buildings designed for flexible use are practically quite inflexible due to insufficient building systems or/and irresponsible planning. There have been two dominant strategies to achieve architectural flexibility: multi-functionality and polyvalence. These two approaches, which point contradictory directions, actually reflect the difficulty in providing a proper form of architectural flexibility. Multi-functionality can afford changeable environments with satisfying spatial conditions; however it lacks tolerance to accommodate other uses but intended functions by architects. Meanwhile, flexibility by a polyvalent form relies on the vague anticipation of user's various interpretations. In this study by looking up these two different standpoints and historical precedents flexibility in architecture is carefully scrutinized focused on the contradiction, and as an alternative for architectural flexibility contextual relations is proposed. Unlike both multi-functionality and polyvalence, which produce flexibility by changing its own properties, manipulating contextual relations infuses flexibility into space by changing the properties of a building, not of its individual room. By using this contextual relations method, a community-centered school in Manhattan, NY, which was in danger of being closed because of its academic failure, is represented as a flexible space.

Short Circuit Tests of the Three-Phase DC Reactor Type Fault Current Limiter in Changing of Turns Ratio of Transformers (변압기 권선비의 변화에 따른 3상 DC 리액터형태 한류기의 단락실험)

  • Lee, Eung-Ro;Lee, Chan-Ju;Lee, Seung-Je;Go, Tae-Guk;Hyeon, Ok-Bae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.267-272
    • /
    • 2002
  • This Paper deals with the short circuit tests of the three-Phase DC reactor type fault current limiter (FCL) in changing of turns ratio of transformers. The experiment of this paper is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. So, superconducting coil was made of Nb-Ti, low temperature superconductor, and the ratings of the power system of experimental circuit are 400V/7A class. A three-phase DC reactor type FCL consists of three transformers, six diodes, one superconducting coil and one cryostat. The important point of experimental analysis is transient period, the operating lagging time of circuit breaker. As the results of the experiment, the values are referred to the limitation rate about 77% and 90% when the turns ratio of transformer was 1:1 and 2:1 respectively.

A Study on the Urban Type Silver Town based on Smart Technology - With Focus on the Behavior of the Elderly - (스마트 기술을 적용한 도시형 실버타운에 관한 연구 - 노인의 행태를 중심으로 -)

  • Lee, Jeong-Pil;Jung, Chul-Oh;Kim, Yong-Seong
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.141-148
    • /
    • 2006
  • Recently, human's life is more longer and the birth rate continually decrease by the development of medical technology. In 2026 the ratio of the elderly will come up to 20.8% and be a 'post-aged society'. Development of economy and industrialization not only accelerate the urbanization and formation of nuclear family, but also change the changing of traditional society and one's value. So the issue of society and value's changing in the elderly increase the centralizing in the silver industry, and by the recent research about the elderly, they not want to live with their children, but want to live independently. This study is meaningful at the next generation of Ubiquitous society and post-aged society, proposing the smart silver town in urban type and let the elderly keeping the existing life in city. It realize the concept of 'Aging in Place' and propose the smart silver town in urban type which appropriate to behavior of the elderly, and being satisfy with various requirements of the elderly. This study point up the combination of physical elements and electronic elements through the smart technology, and making an smart environment to compose the smart silver town in urban type which react the behavior of the elderly.

Angle Calculation Rotation Angle of One-axis Manipulator in Laser Module (레이저모듈에서의 1-축 틸팅의 회전각 계산)

  • Jung, Dong-Won;Kim, Dong-Hong;Kim, Bong-Chun;Kim, Dong-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.5
    • /
    • pp.506-509
    • /
    • 2012
  • Laser assisted machining is the processing method that preheating brittle materials by laser heat source and cutting the soften area. This processing applied to various industries because it can be cutting difficult-to-cut materials. However, the laser assisted machining appeared the limitations of processing for equipped with the spindle. So, it assumed separate model that spindle and laser assisted machining. In feed, the calculation of changing the angle of the laser module according to preheat point and the shape of the feed is important and it tried easy calculating changing angle of 1-axis Manipulator in separate model. In 3 types feed shape, angle of 1-axis Manipulator was calculated when fixed and moved in the outside of spindle. In this study, suggest 2 types of methods for laser module when fixed and moved.

Design and Implementation of Group Decision Support System using Object-Oriented Modeling Technique (OMT를 이용한 그룹의사결정지원시스템의 설계 및 구현)

  • Kim, Soung-Hie;Cho, Sung-Sik;Kim, Sun-Uk;Park, Hung-Kook
    • IE interfaces
    • /
    • v.10 no.1
    • /
    • pp.169-187
    • /
    • 1997
  • Recently, in organizations many decisions are being made by groups. And the organization is changing a lot so are groups. To help decision making of changing groups, we need more flexible and more adaptive GDSS. Therefore one of the critical success factors of GDSS is flexibility and incremental improvement. Prior research on specifying design requirements of GDSS suggests generic design requirements. But they are too general to be incorporated directly into system design, because of the disparity between real group and ideal group that the researchers studied. Many design strategies that start from the generic design requirements thus have contingency variables that changes as the characteristics of group change. From the viewpoint of developers, these variables implicate the desirability of flexibility. To achieve flexibility we need new methodology of design and implementation. Nowadays, object-oriented analysis and design methodologies have been progressed to the point that many systems are being developed through these methodologies. In this paper, a design is proposed using Object-Oriented Modeling Techniques(OMT). Exploiting object-oriented paradigm results in a highly flexible and easily upgradable design.

  • PDF