• Title/Summary/Keyword: chambers

Search Result 893, Processing Time 0.028 seconds

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

Chemical Fluxes at the Sediment-Water Interface Below Marine Fish Cages on the Coastal Waters off Tong-Young, South Coast of Korea (남해안 통영지역 가두리양식장 해수-퇴적물 경계면에서의 chemical fluxes)

  • Shim, Jeong-Hee;Kang, Young-Chul;Choi, Jin-Woo
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.2 no.2
    • /
    • pp.151-159
    • /
    • 1997
  • Benthic respiration and chemical fluxes were measured at the sediment-water interface underlying the marine fish cages floating on the open coastal waters off Tong-Young, the South Coast of Korea. The effects of cage farming on coastal benthic environment and on mass balance of organic carbon in the benthic boundary layer under the marine fish cages are addressed. In a growing season of caged fishes of June, 1995, benthic chambers and sediment traps were deployed on the sediment-water interfaces of the two sites chosen for this study: 1) Cage Site, directly underlying the fish cages of the farm at 18 m water depth, and 2) Control Site, about 100 m away from the farm at 32 m water depth. Benthic respiration rates and chemical fluxes were calculated from the evolution of dissolved oxygen and chemicals in the chamber water, and mass balance of organic carbon in the benthic boundary layer was constructed based on the vertical flux of particulate organic matter (POM) and chemical fluxes out of the sediment. High organic dumping (6400 mg C $m^{-2}d^{-1}$) and high benthic respiration (230 mmol $O_2\;m^{-2}d^{-1}$) were observed at the Cage Site. Equivalent to 40% of vertical flux of organic carbon into the Cage Site seemed to be decomposed concurrently and released back to overlying waters (2400 mg C $m^{-2}d^{-1}$). Consequently, up to 4000 mg C $m^{-2}d^{-1}$ of organic carbon could be buried into the farm sediment (equivalent to 60% of organic carbon flux into the Cage Site). At the Control Site, relatively less input of organic carbon (4000 mg C $m^{-2}d^{-1}$) and low benthic respiration rate (75 mmol $O_2\;m^{-2}d^{-1}$) were observed despite short distance away from the cages. The influence of cage farming on benthic chemical fluxes might be restricted and concentrated in the sea bottom just below the fish cages in spite of massive organic dumping and high current regime around the fish cage farm.

  • PDF

Effect of Sodiun Hypochlorite Pretreatment, Light Intensity and Depth of Soil Covering on Germination of Cattail(Typha spp.) Seeds (Sodium Hypochlorite 처리와 광도 및 복토 깊이의 차이가 부들의 종자 발아에 미치는 영향)

  • Kim Young-Ju;Heo Jin-Ah;Hwang Yong-Soo;Ku Ja-Hyeong
    • Asian Journal of Turfgrass Science
    • /
    • v.19 no.2
    • /
    • pp.115-123
    • /
    • 2005
  • The effect of sodium hypochlorite treatment on the germination of cattail (Typha spp.) seeds was investigated in growth chambers maintained on a 14-h photoperiod with various temperatures and light intensities. Germination rates of seeds were, in general, enhanced by the increase of light intensity and temperature regardless of cattail species. Seeds of T. oreientalis had 4.3, 13.0 and $7.3\%$ germination at temperatures of 20, 25 and $30^{circ}$C, respectively, under light intensity of 7.5${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. T. angustata showed higher germination rate, thus, 10.7, 22.7 and $50.7\%$ under same temperature and light environment. Under high light intensity of 79.5${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, the germination rates of T. oreintalis and T angustata were $78.3\%$ and $88.7\%$ at $30^{circ}$C, respectively. Scarification of seeds with NaOC1 ($4\%$, available chlorine) increased germination rate in both species, especially even at low temperature of $20^{circ}$C. Germination speed was also enhanced by NaOC1 treatment. High light intensity further increased the germination rate. When NaOC1 treated seeds were sowed on the soil surface in plastic house, the seedling emergence was nearly $100\%$. Untreated seeds of T. oreintalis and T. angustara showed 40 and $50\%$, respectively, in germination under same condition. However, when the depth of soil covering was over 1.0 cm, seedling emergence was retarded more than 1 month. On the process of seedling development, emergence of mesocoty1 occurred firstly and after than primary root and first leaf were developed on the end of elongated mesocotyl. These results suggest that the promotion of seed germination by NaOC1 pretreament may be induced from the increase of light absorptivity as well as water permeability through scarifying and bleaching the seed coat.

Effects of Temperature on Leaf Emergence Rates and Phyllochron of Naked and Malting Barley (온도가 쌀보리와 맥주보리의 출엽속도와 출엽간격에 미치는 영향)

  • Kang, Young-Kil;Ko, Koan-Su;Kang, Bong-Kyoon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.5
    • /
    • pp.449-457
    • /
    • 1993
  • Three naked and three malting barley cultivars were grown at constant temperatures of 4, 8, 12, 16, 20, 24 and 28$^{\circ}C$, and day/night temperatures of 6/2, 10/6, 14/10, 18/14, 22/18, 26/22 and 30/26$^{\circ}C$ through the fourth leaf stage in growth chambers to determine the effects of the temperature on leaf emergence rate and phyllochron in naked and malting barley seedlings. The number of leaves per main stem was recorded daily from the first leaf stage to the fourth. At a given temperature, the emergence of new leaves was a linear function of time for all cultivars. There were no great differences in leaf emergence rate and phyllochron between constant and variable day/night temperature regimes except at 28$^{\circ}C$. Leaf emergence rate and phyllochron significantly differed among cultivars and among mean temperatures within cultivars. For all cultivars, leaf emergence rate per day increased parabolically with increasing mean air temperature until an optimum temperature was reached and then declined. There were no differences in the optimum temperatures for the leaf emergence rate per day among six cultivars, which ranged 20.1 to 21.5$^{\circ}C$. The leaf emergence rates at the optimum temperatures ranged 0.202 to 0.226 leaves / day for naked barley cultivars and 0.231 to 0.241 leaves / day for malting barley cultivars. As temperature increased, leaf emergence rate per GDD decreased exponentially and the phyllochron (GDD/leaf) increased exponentially. The mean of the phyllochron for six cultivars was 46.2 GDD at 4$^{\circ}C$ and 129.3 GDD at 28$^{\circ}C$. These results suggest that the temperature and cultivar effects must be considered for prediction of leaf development in barley.

  • PDF

Effects of Pre Harvest Light Treatments (LEDs, Fluorescent Lamp, UV-C) on Glucosinolate Contents in Rocket Salad (Eruca sativa) (수확 전 LED, 형광등, UV-C 조사가 로켓 샐러드 내 글루코시놀레이트 함량에 미치는 영향)

  • Lee, Hye-Jin;Chun, Jin-Hyuk;Kim, Sun-Ju
    • Horticultural Science & Technology
    • /
    • v.35 no.2
    • /
    • pp.178-187
    • /
    • 2017
  • The aim of this study was to investigate the effect of different light sources on the levels of glucosinolates (GSLs) in rocket salad (Eruca sativa L.). The light sources used in the study were: natural light (Control-1 or 2), red light-emitting diodes(LEDs), blue LEDs, mixed red and blue LEDs (R+B LEDs), white LEDs, fluorescent lamps (FL), and fluorescent lamps plus UV-C (FL+UV-C). Two separate experiments were conducted [Experiment I: Control-1, Red LED, Blue LED, Mix (R+B) LED and Experiment II: Control-2, White LED, FL, FL+UV-C] because of the limited number of growth chambers in our laboratory. The rate of increase in the length of rocket salad leaves was the highest under red LEDs and, FL confirming that red LED and, FL affect the growth of rocket salad. We separated and identified seven types of GSLs from the rocket salad:glucoraphanin, diglucothiobeinin, glucoerucin, glucobrassicin, dimeric 4-mercaptobutyl GSL, 4-methoxyglucobrassicin, and gluconasturtiin. The highest total GSL contents in Eexperiment I was found in plants grown under in red LEDs ($4.30{\mu}mol{\cdot}g^{-1}\;dry$ weight, DW), and the lowest under blue LEDs ($0.17{\mu}mol{\cdot}g^{-1}\;DW$). The highest total GSL contents in Experiment II was found in plants grown under FL ($13.45{\mu}mol{\cdot}g^{-1}\;DW$), and the lowest in FL+UV-C ($0.39{\mu}mol{\cdot}g^{-1}\;DW$). Especially in Experiment II, the content of dimeric 4-mercaptobutyl, which has a strong aroma and spicy flavor in rocket salad, was higher under FL and white LEDs than in Control-2, increasing by approximately 14.9 and 3.2-fold respectively. Therefore, light sources such as red LEDs, white LEDs and FL affected the accumulation of GSLs in rocket salad.

Filter-Feeding Effect of a Freshwater Bivalve (Corbicula leana PRIME) on Phytoplankton (식물플랑크톤에 대한 담수산 패류 (참재첩)의 섭식효과)

  • Kim, Ho-Sub;Shin, Jae-Ki;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.4 s.96
    • /
    • pp.298-309
    • /
    • 2001
  • The purpose of this study was to evaluate the filtering-feeding effect of a freshwater mussel (Corbicula leana) on the phytoplankton communities in two lakes with different trophic conditions between June and September, 2000. Manipulation experiments were conducted with two treatments (the control and mussel addition), and each established in duplicate 10 l chambers. Both ambient nutrient (TN, TP) and chlorophyll-a concentrations were significantly (p<0.01) higher in Lake Ilgam than Lake Soyang. Cyanophytes (Microcystis, Oscillatoria, Lyngbya and Dactylococcopis) consistently dominated algal community in Lake llgam, while flagellated algae (Dinobryon divergence, Mallomonas, Rhodomonas) and cyanophytes (Microcystis)dominated in Lake Soyang. The net exponential death rate ($R\;=\;day^{-1}$) of total phytoplankton in the mussel treatment ranged $1.70{\sim}7.39$ and $0.38{\sim}1.64$ in Lakes Soyang and Ilgam, respectively. Mean filtering rate standardized by mussel AFDW ($ml\;mgAFDW^{1}\;h^{-1}$) was much higher in Lake Soyang ($1.70{\sim}3.06$) than in Lake Ilgam($0.24{\sim}0.88$0.24~o.88). Estimating FR per mussel, 1 mussel filtered $1.6{\sim}7.8\;l$ per day and $1.7{\sim}3.0\;l$ per day in Lakes Soyang and Ilgam, respectively. Based on tile C-flux tobiomass ratio, Corbicula leana consumed $0.8{\sim}4.4$ fold of phytoplankton standing stock in Lake Soyang, and $0.4{\sim}1.6$ fold in Lake Ilgam per day. Mussel feeding resulted in increase of SRP concentration by $30{\sim}50%$, compared with the control. The results of this study suggest that filter-feeding activity of Corbicula leana varies depending on the phytoplankton density and community composition. The high seston consumption rate of Corsicuja Jeaua even in a eutrophic lake suggests that biomanipulation approach using filter-feeding mussels can be used far wate rquality management in small eutrophic reservoirs.

  • PDF

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

A Survey on the Actual State of Laboratory Facilities and Equipments at Nursing Schools (간호교육기관의 실험실습설비 보유실태 조사)

  • Lim, N.Y.;Lee, S.O.;Suh, M.J.;Kim, H.S.;Kim, M.S.;Oh, K.O.
    • The Korean Nurse
    • /
    • v.36 no.1
    • /
    • pp.108-117
    • /
    • 1997
  • This study was carried out to examine the standards for evaluation of laboratory facilities and equipment. These constitute the most important yet vulnerable area of our system of higher education among the six school evaluation categories provided by the Korean Council for University Education. To obtain data on the present situation of holdings and management of laboratory facilities and equipment at nursing schools in Korea, questionnaires were prepared by members of a special committee of the Korea Nursing Education Society on the basis of the Standards for University Laboratory Facilities and Equipment issued by the Ministry of Education. The questionnaires were sent to nursing schools across the nation by mail on October 4, 1995. 39 institutions completed and returned the questionnaires by mail by December 31 of the same year. The results of the analysis of the survey were as follows: 1. The Physical Environment of Laboratories According to the results of investigation of 14 nursing departments at four-year colleges, laboratories vary in size ranging from 24 to 274.91 pyeong ($1{\;}pyeong{\;}={\;}3.3m^2).$. The average number of students in a laboratory class was 46.93 at four-year colleges, while the number ranged from 40 to 240 in junior colleges. The average floor space of laboratories at junior colleges, however, was almost the same as those, of laboratories at four-year colleges. 2. The Actual State of Laboratory Facilities and Equipment Laboratory equipment possessed by nursing schools at colleges and universities showed a very wide distribution by type, but most of it does not meet government standards according to applicable regulations while some types of equipment are in excess supply. The same is true of junior colleges. where laboratory equipment should meet a different set of government standards specifically established for junior colleges. Closer investigation is called for with regard to those types of equipment which are in short supply in more than 80 percent of colleges and universities. As for the types of equipment in excess supply, investigation should be carried out to determine whether they are really needed in large quantities or should be installed. In many cases, it would appear that unnecessary equipment is procured, even if it is already obsolete, merely for the sake of holding a seemingly impressive armamentarium. 3. Basic Science Laboratory Equipment Among the 39 institutions, five four-year colleges were found to possess equipment for basic science. Only one type of essential equipment, tele-thermometers, and only two types of recommended equipment, rotators and dip chambers, were installed in sufficient numbers to meet the standards. All junior colleges failed to meet the standards in all of equipment categories. Overall, nursing schools at all of the various institutions were found to be below per in terms of laboratory equipment. 4. Required Equipment In response to the question concerning which type of equipment was most needed and not currently in possession, cardiopulmonary resuscitation (CPR) machines and electrocardiogram (ECG) monitors topped the list with four respondents each, followed by measuring equipment. 5. Management of Laboratory Equipment According to the survey, the professors in charge of clinical training and teaching assistants are responsible for management of the laboratory at nursing schools at all colleges and universities, whereas the chief of the general affairs section or chairman of the nursing department manages the laboratory at junior colleges. This suggests that the administrative systems are more or less different. According to the above results, laboratory training could be defined as a process by which nursing students pick up many of the nursing skills necessary to become fully qualified nurses. Laboratory training should therefore be carefully planned to provide students with high levels of hands-on experience so that they can effectively handle problems and emergencies in actual situations. All nursing students should therefore be thoroughly drilled and given as much on-the-job experience as possible. In this regard, there is clearly a need to update the equipment criteria as demanded by society's present situation rather than just filling laboratory equipment quotas according to the current criteria.

  • PDF

Dosimetric Characteristics of a Thermal Neutron Beam Facility for Neutron Capture Therapy at HANARO Reactor (하나로 원자로 BNCT 열중성자 조사장치에 대한 선량특성연구)

  • Lee, Dong-Han;Suh, So-Heigh;Ji, Young-Hoon;Choi, Moon-Sik;Park, Jae-Hong;Kim, Kum-Bae;Yoo, Seung-Yul;Kim, Myong-Seop;Lee, Byung-Chul;Chun, Ki-Jung;Cho, Jae-Won;Kim, Mi-Sook
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • A thermal neutron beam facility utilizing a typical tangential beam port for Neutron Capture Therapy was installed at the HANARO, 30 MW multi-purpose research reactor. Mixed beams with different physical characteristics and relative biological effectiveness would be emitted from the BNCT irradiation facility, so a quantitative analysis of each component of the mixed beams should be performed to determine the accurate delivered dose. Thus, various techniques were applied including the use of activation foils, TLDs and ionization chambers. All the dose measurements were perform ed with the water phantom filled with distilled water. The results of the measurement were compared with MCNP4B calculation. The thermal neutron fluxes were $1.02E9n/cm^2{\cdot}s\;and\;6.07E8n/cm^2{\cdot}s$ at 10 and 20 mm depth respectively, and the fast neutron dose rate was insignificant as 0.11 Gy/hr at 10 mm depth in water The gamma-ray dose rate was 5.10 Gy/hr at 20 mm depth in water Good agreement within 5%, has been obtained between the measured dose and the calculated dose using MCNP for neutron and gamma component and discrepancy with 14% for fast neutron flux Considering the difficulty of neutron detection, the current study support the reliability of these results and confirmed the suitability of the thermal neutron beam as a dosimetric data for BNCT clinical trials.

  • PDF

Features and Component Analysis of the GeumguJagi(金釦瓷器) Excavated from Seongneung(石陵) (석릉(碩陵) 출토 금구자기(金釦瓷器)의 특징과 성분 분석)

  • Sung, Kiyeol
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.150-167
    • /
    • 2020
  • The purpose of this paper is to share the status and introduce a scientific analysis of the GeumguJagi (gilt-silver overlay porcelain, 金釦瓷器) excavated from Seongneung (石陵). This analysis aimed to highlight the GeumguJagi excavated from the Royal Tombs of Goryeo with a clear lower year (1237) and to aid research into the GeumguJagi. In 2001, the National Institute of Cultural Heritage excavated and investigated Seongneung in Heejong (熙宗). Various artifacts such as celadon, gold, bronze, and iron products were collected from the chambers inside of the tomb. There were a total of 160 celadon items including bowls, dishes, glasses, and saucers. Of those, there were 58 celadon items (including fragments) with metal frames on the openings. These consisted of bowls, plates, lids, and saucers. Until recently, in various exhibitions and papers, only one GeumguJagi was known to have been excavated from Seongneung, which was a . However, the survey identified a number of further GeumguJagis. It had been understood from inherited and excavated products that the materials used for ornaments were restricted to high-quality celadon. However, this study confirmed that the excavation of Seongneung demonstrated the use of various other materials for different models and qualities of GeumguJagis. It can be said that it is characteristic that various models and quality are confirmed together through the excavation of Seongneung. A scientific analysis was carried out that selected 12 of 58 products excavated from Seongneung. Results showed that the main component used for Geumgu ornaments was tin (Sn), and trace amounts of copper (Cu) and lead (Pb) were also commonly identified. When analyzing the material used to affix the metal fittings, this was found to be glue (膠) made from animal skins, muscle, and bones. This pattern matches that of the GeumguJagi excavated from Paju Hyeeumwonji, and the reason for this could be assumed on the basis of the contents of the 『Cheongonggaemul (天工開物)』 written by Song Ongsung (宋應星) during the Ming Dynasty. At that time, metals such as tin and copper would have been difficult to obtain. 『Xuānhwafengshi Gaolitujing (宣和奉使高麗圖經)』 shows that the use of metal was limited to certain classes; thus, the use of the GeumguJagi seems to have been centered around the royal family.