• 제목/요약/키워드: chambers

검색결과 893건 처리시간 0.026초

Effect of Shiitake(Lentinus edodes. p) Mushroom Powder and Sodium Tripolyphosphate on Texture and Flavor of Pork Patties

  • Chun, S.S.;Edger Chambers IV;Delores H. Chambers
    • 한국식품영양학회:학술대회논문집
    • /
    • 한국식품영양학회 2004년도 하계 학술 심포지엄
    • /
    • pp.48-48
    • /
    • 2004
  • Shiitake mushroom contained numerous nutrients, special flavor (lenthionine) and taste. In Asia, they are thought to have numerous medical properties f3r several diseases such as diabetes, anemia, tumors. Phosphates are known to increase hydration and water binding, stabilize meat emulsions, improve juiciness and tenderness, provide mineral supplementation, and maintain flavor of processed meat products. A lexicon f3r describing the texture and flavor of cooked pork patties were developed. (omitted)

  • PDF

Descriptive Sensory Characteristics of Beef Jerky Prepared Different Methods

  • Lee, J.H.;Iv, Edgar-Chambers;Chambers, Delores-H.;Chin, K.B.;Kim, R.Y.;Chun, S.S.;Oh, J.S.
    • 한국식품영양학회:학술대회논문집
    • /
    • 한국식품영양학회 2004년도 하계 학술 심포지엄
    • /
    • pp.49-49
    • /
    • 2004
  • Beef jerky is a traditional salted or soysauce-added and dried Korea meat product. Jerky is made from loins which is thin sliced, curing salt(soysauce-added), smoked and dried. The purpose of this study was to investigate the effects curing salt soy sam and/or smoking. A lexicon for describing the texture and flavor of beef jerky were developed. The intensity of a vatiety of texture, flavor, and mouth feel properties was characterized for beef jerky. A highly trained descriptive sensory panel identified, defined and referenced 17 attributes for beef jerky. (omitted)

  • PDF

산업용 송풍기 소음기의 성능개선을 위한 실험적 연구 (An Experimental Study on the Performance Improvement of Industrial Blower Silencer)

  • 김병삼;김용우
    • 한국소음진동공학회논문집
    • /
    • 제15권9호
    • /
    • pp.1060-1069
    • /
    • 2005
  • Silencers are engineering devices that are designed to attenuate sound waves propagating in a flowing medium. The muffler type silencer has a series of chambers in parallel or series utilizing the reflection and expansion characteristics of the expansion chambers, sidetubes, branch resonators, and tailpipes to attenuate the sound. To Improve the performance of industrial blower silencer of muffler type which is employed in petrochemical plant, this paper seeks its optimal arrangement of buffs by experimental method and suggests optimal arrangement of buffs. Experimental results show that the optimal one suggested can reduce the noise level as much as 14 dB (or 18 dB(A)) in the laboratory and as much as 4 dB(A) compared to that of the existing silencer on the ground.

멀티형 냉방시스템의 압축기 제어 (Compressor Control of a Multi-type AIr Conditioning System)

  • 한도영;권형진
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.780-786
    • /
    • 2001
  • For the compressor speed control of a multi-type air conditioning system, a fuzzy control algorithm was developed. The sum of zone temperature errors and its derivative were used as input variables, and the compressor speed was selected as the output variable. To test the effectiveness of the control algorithm, one outdoor environmental chamber and four indoor environmental chambers were used. In the chambers the zone temperature step change test and the indoor unit change over test were performed. Test results showed that, for the control of compressor speed, the fuzzy control algorithm was more effective than the conventional proportional control algorithm for the energy conservation.

  • PDF

SAS 반응기의 구조 안전성 평가 연구 (Study for Accessment of Structural Stability of SAS Reactor)

  • 이은우;정의동;김윤춘;김종배
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.43-49
    • /
    • 1995
  • Sasol Advanced Synthol Reactor was divided into two chambers by grid plate perforated with diffuser holes. The reactor has high stress level beacuse of membrane stress due to internal pressure, thermal stress due to temperature difference and local stress due to structural discontinuity at the juncture of grid plate and shell. Moreover, geometric nonlinear behaviors may appear in the grid plate because of pressure difference between two chambers. In order to survey the stress level and geometric nonlinear behaviors around grid plate, heat transfer analysis, linear static analysis and geometric nonlinear analysis were performed using NISA II developed by EMRC. This paper demonstrates the result of accessment for linear static and geometric nonlinear analysis under various load combinations.

  • PDF

패널형 흡음재를 이용한 무향실의 설계 (Anechoic Chamber Design using Broadband Compact Absorber)

  • 두세진;오세웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.393-396
    • /
    • 2003
  • Conventional method for designing and installing anechoic chambers is to utilize porous wedges for the sound absorbers. As cutoff frequency lowers down such as 63Hz or 50Hz, the corresponding long wedges diminish the free field area of the chamber. In this study, a new broadband compact absorber(BCA) is introduced which absorbs acoustic energy down to 50Hz. Most prominent is that it measures only 250mm thick. A freely vibrating panel between the non-fibrous absorbers allows tuned absorption at the low frequency region in addition to the high frequency absorption resulted from the conventional absorber installed at the front. Standing waves at low frequency range are suppressed as the BCA modules which are tuned to the corresponding modes absorb sound energy effectively, resulting in anechoic condition. Not only the low frequency performances, but the high frequency absorption is measured to meet adequate conditions for the anechoic chamber. Realized BCA chambers are presented.

  • PDF

횡형 스크롤 압축기의 가스 맥동에 관한 연구 (A Study on the Gas Pulsation in a Horizontal Scroll Compressor)

  • 최진섭;김현진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.41-45
    • /
    • 1999
  • Analytical and experimental investigations have been carried out on the gas pulsations in the discharge paths of a high-side horizontal scroll compressor, where the gas discharged from compression chamber is made to pass through several chambers inside the compressor shell. Model of Helmholtz resonators in series has been applied to this configuration to predict gas pulsation phenomena along the passages, and the calculation results have been compared with measured pressure time traces. Good agreements between the analytical and experimental results have been obtained. It has also been found that the compressor performance is somewhat affected by the size of individual chambers Inside the compressor shell.

  • PDF

An Unusual Biatrial Cardiac Myxoma in a Young Patient

  • Azari, Ali;Moravvej, Zahra;Chamanian, Soheila;Bigdelu, Leila
    • Journal of Chest Surgery
    • /
    • 제48권1호
    • /
    • pp.67-69
    • /
    • 2015
  • This is a report of a biatrial cardiac myxoma in a young man with a 10-month history of exertional dyspnea and palpitation. The echocardiogram revealed biatrial myxoma prolapsing through the mitral and tricuspid valves during diastole. All cardiac chambers were enlarged and dysfunctional. The electrocardiogram revealed a rapid ventricular response with atrial flutter rhythm. The masses were resected and diagnosed as myxoma by a histological examination. The follow-up echocardiogram revealed significant improvement in ventricular function and reduction in the cardiac chambers' volume. There was no evidence of myxoma recurrence. The most probable cause of the patient's heart failure was considered to be tachycardia-induced cardiomyopathy.

송신 안테나에 의한 5 GHz 이차 잔류 디퓨저를 적용한 전자파 잔향실의 내부 필드 균일도 변화 (Electric Field Uniformity in Reverberation Chamber with 5 GHz Diffuser by Transmission Antenna)

  • 이유진
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.83-86
    • /
    • 2021
  • In this paper, electric fields in electromagnetic reverberation chambers, which are used as a substitute facility for EM-free anechoic chambers, are analyzed. This paper focused on the 4-5 GHz band, which is expected to adversely affect equipment. To analyze the field uniformity inside the electromagnetic reverberation chamber, electric field strengths are sampled and finite-difference time-domain method was used for numerical analysis. Moreover, Quadratic residue diffuser was used to improve the characteristics of the electromagnetic reverberation chamber and the uniformity of the internal field strength. Standard deviation, tolerance characteristics, and partiality characteristics were compared while varying the aiming point of transmission antenna.

Intercomparison of KAERI Reference Photon Radiation Fields

  • S.Y.Chang;J.C.MacDonald;M.K.Murphy;Kim, B.H.;Lee, K.C.
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.34-39
    • /
    • 1996
  • A series of measurements was peformed between KAERI and PNNL, U.S.A at KAERI secondary calibration laboratory to intercompare and verify the KAERI reference photon radiation fields by using air equivalent plastic walled ionization chambers, Different ionization chambers of two laboratories were used to determine the air kerma rate, free-in-air, at reference positions in the KAERI photon radiation fields, As the results, the agreement in the cross measurements between two laboratories was found to be within less than ${\pm}$ 3 %. This degree of consistency was considered to be encouraging, because each laboratory maintains independently its calibration traceablity with its national primary standard

  • PDF