Estimation of Thermodynamic/Transport Properties of Kerosene using a 3-Species Surrogate Mixture (3-화학종 대체 혼합물을 이용한 케로신의 열역학적·전달 상태량 예측)

  • Joh, Miok;Kim, Seong-Ku;Choi, Hwan-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.874-882
    • /
    • 2013
  • Kerosene(Jet A-1), one of the propellants for each stage's engine of the Korea Space Launch Vehicle-II(KSLV-II), functions as coolant at the same time as it flows inside the cooling jacket of the combustion chambers and is injected through the film cooling holes. A physical surrogate mixture model to reproduce the thermophysical characteristics of Jet A-1 has been selected and the thermodynamic/transport properties of the model fuel under high pressure including supercritical conditions have been estimated using SUPERTRAPP(NIST SRD4). Comparisons with the measured properties suggest that proposed database can be used to extract properties of Jet A-1 for conjugate heat transfer analysis of liquid propellant rocket engine thrust chambers. Predicted combustion/cooling performance of regeneratively cooled thrust chambers shall be validated through comparisons with upcoming firing test results.

A Study on the Measurement of the Beam Pattern of Array Antenna for VHF Radar using Active Beam Pattern Measuring Device and Drone (능동 빔패턴 측정장치 및 드론을 활용한 초단파레이다용 배열안테나의 빔패턴 측정에 대한 연구)

  • Kim, Ki-Jung;Lee, Sung-Je;Jang, Youn-Hui
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1031-1036
    • /
    • 2019
  • This study describes the technique of the beam pattern measurement of array antenna for VHF band radar using drone and active beam pattern measuring device. There is no anechoic chamber for measuring the beam pattern of a large size antenna in the country. In this study, to test the antenna beam pattern characteristics of the developed VHF band radar, the antenna beam pattern characteristics were tested by Drone mounting an Active Beam Pattern Measuring Device. By comparing the results of the pre-simulation analysis with the measured results for the antenna, we could confirm that the beamwidth and side-lobe characteristics are satisfactory. Through the antenna beam pattern measurement technology using Drone and Active Beam Pattern Measuring Device, the beam pattern measurement technology of array antenna of low frequency band and large antenna for low band radar will be used.

Analysis of Accelerated Aging Natural Ester Oil and Mineral Oil in Distributional Transformers (배전용 변압기에서의 고온열화와 열 사이클 열화에 따른 식물유와 광유의 특성 분석)

  • An, Jung-Sik;Choi, Sun-Ho;Bang, Jeong-Ju;Jung, Joong-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1163-1168
    • /
    • 2011
  • Most transformers use insulating and cooling fluids derived from petroleum crude oil, but mineral oil has some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Four transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Experiment for aging carry out two means. First means remained $120^{\circ}C$ that transformer of mineral oil were operated at 185% load. Second means is that insulating oils of two natural ester and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. For the heating, Transformers were operated at 185% load. For the cooling, cooling system was operated in the chamber. Samples were analyzed at 42, 63, 93, 143, 190, 240 300cycles. Analysis contents are dielectric strength, total acid value. Mineral oils compared results of first means with results of second means. And compared two sort natural esters respectively with mineral oil in second means.

Surface Discharge Characteristics Study on the Laminated Solid Insulator in Quasi-Uniform Electric Field with Dry Air

  • Min, Gyeong-Jun;Bae, Sungwoo;Kang, Byoung-Chil;Park, Won-Zoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.603-609
    • /
    • 2015
  • Dry air is an excellent alternative to $SF_6$ gas and is used as an insulation gas in Eco-friendly Gas Insulated Switchgears (EGISs), which has gained popularity in industry. Solid insulators in EGIS play an important role in electrical insulation. On the other hand, surface discharge can occur easily when solid insulators are used. This paper explored the surface discharge characteristics on the structure of three-layered laminated solid insulators to elevate the flashover voltage. A laminated solid insulator was inserted after the quasi-uniform electric field was formed in the test chamber. Dry air was then injected to set the internal pressure to 1 ~ 6 atm, and the AC voltage was applied. When identical solid insulators were stacked, the surface discharge characteristics were similar to those of a single solid insulator. On the other hand, the flashover voltage rose when the middle part was thicker and had lower permittivity than the top and bottom parts in the laminated solid insulator. Based on experimental results, when stacking a solid insulator in three layers, the middle part of the solid insulator should be at least four times as thick as the top and bottom parts and have lower permittivity than the others. In addition, the flashover voltage increased with increasing gas pressure on the surface of the laminated solid insulator due to the gas effect. This study may allow insulation design engineers to have useful information when using dry air for the insulation gas where the surface discharge can occur.

Evaluation of silicon powder waste quality by electromagnetic induction melting and resistance test (단결정 잉곳의 표면 그라인딩에서 발생하는 고순도 실리콘 분말 폐기물의 용해 및 품질 평가)

  • Moon, Byung Moon;Kim, Gangjune;Koo, Hyun Jin;Shin, Je Sik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.187.2-187.2
    • /
    • 2011
  • 태양광산업의 value chain중 up-stream쪽인 고순도 실리콘산업은 셀, 모듈, 시스템 쪽에 비하여 영업 이익률이나 부가가치 측면에서 매우 높은 성장성을 현재 보여주고 있으며 최근 원자력산업의 안전성 문제가 대두됨으로 인하여 태양광수요가 전 세계적으로 증대되는 경향을 나타내어 태양광용 실리콘의 수요가 확대됨과 아울러 spot시장에서의 가격 또한 상승하고 있다. 이런 관점에서 잉곳 및 웨이퍼 가공 중에 발생하는 고순도 실리콘 폐기물의 재활용 이 다시 주목받고 있다. 태양전지 웨이퍼(wafer)용 소재는 6N급 이상의 결정질 실리콘 잉곳(ingot)이 주를 이루며, 고효율의 셀을 제조하기 위해서 단결정 실리콘 잉곳이 많이 사용된다. 실리콘 단결정을 육성하는 방법에는 Floating zone 법, Czochralski 법, Bridgeman 법, CVD 등 매우 다양하다. 이 중 Czochralski 법은 전체 생산량의 대부분을 차지하고 있는 방법으로, 용융액에서 결정을 인상하여 ingot을 제작하는 방법이다. 그러나 대량의 전기에너지를 소비하여 제작되는 고순도의 실리콘 단결정 잉곳은 후 가공공정에서 그 절반 이상이 분말(powder) 및 슬러지(sludge)로 폐기되므로, 자원의 재활용 및 환경오염 측면에서 주요과제가 되고 있다. Czochralski 법으로 제작된 ingot의 경우 그 표면이 매끄럽지 못하여, 웨이퍼 단위의 가공 시 형태가 진원이 될 수 있도록 표면을 미리 연마(grinding)하는데, 이때에도 미세 분말이 다량 발생하게 된다. 본 연구에서는 이러한 고순도 단결정 실리콘 ingot의 연마 가공공정에서 발생한 미세 분말을 용해하여 보았다. 진공 챔버(chamber) 내부에 유도가열 코일과 냉도가니로 구성된 장비를 통해 전자기유도가열을 이용하여 실리콘 분말 폐기물을 용해하고, 그 시편을 ICP-MS 및 비저항 측정을 통해 분말 의 특성을 조사하여 재활용 가능성을 검토해 보았다.

  • PDF

Research on the Adsorption Capacity for Benzene, Toluene, Acetone and N-hexane of Activated Carbon Acquired fromthe Domestic Market (국내에서 유통되는 활성탄을 이용한 벤젠, 톨루엔, 아세톤 및 노말 헥산의 등온흡착용량 평가 연구)

  • Lee, Naroo;Yi, Gwangyong;Park, Dooyong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.193-200
    • /
    • 2014
  • Objectives: To develop domestic charcoal tubes with good adsorption capacity, breakthrough experiments were performed on four types of activated charcoal. Materials: The adsorption capacity and the adsorption rate were determined using a modified Wheeler equation after the breakthrough experiment. For four types of charcoal (J, K, S and SKC Inc. 226-01), 100 mg were used in the breakthrough experiment. The test was done on benzene, toluene, n-hexane, and acetone in a dynamic chamber. Results: K charcoal had the greatest surface area and the highest micropore volume. J charcoal had a similar surface area and micropore volume to SKC charcoal. S charcoal had the lowest surface area and micropore volume. J charcoal had the highest adsorption capacity at 101, 252 and 609 ppm of benzene. The gap in benzene adsorption capacity among the types of charcoal was the least at 609 ppm and the greatest at 101 ppm. J charcoal showed the highest adsorption capacity at 54, 106, 228 and 508 ppm of toluene. J charcoal and SKC charcoal had a similar adsorption capacity for acetone. J charcoal had the highest adsorption capacity for n-hexane. In the experiment featuring 10% breakthrough volume, 10% breakthrough occurred at 18 liters at $2065.9mg/m^3$ for J charcoal and at 20 liters at $1771.2mg/m^3$ for K charcoal. It was difficult to judge adsorption capacity by surface area and micropore volume of charcoal. J charcoal, which was similar to SKC charcoal in surface area and micropore volume, showed good adsorption capacity at common workplace concentrations. Conclusions: The adsorption capacity of J and K charcoal was superior compared with SKC charcoal. J and K charcoal can be considered appropriate for use as sampling media based on this result.

A Study on Subchronic Inhalation Toxicity of 2-Methylpentane (2-Methylpentane 아만성 흡입독성 연구)

  • Chung, Yong Hyun;Lim, Cheol Hong;Han, Jeong Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2014
  • Objectives: The purpose of this study was to obtain information regarding classification and health hazards that may result from a 13-week inhalation exposure to 2-methylpentane by Sprague-Dawley rats. Materials: The testing method was conducted in accordance with OECD guidelines for the testing of chemicals No. 413. The rats were divided into four groups(ten male and ten female rats in each group) and exposed to 0 ppm, 290 ppm, 1,160 ppm, 4,640 ppm 2-Methylpentane in each exposure chamber for six hours per day, five days per week, for 13 weeks. Results: No death or particular clinical presentation including weight change and change of feed rate was observed. The relationships between dose, gender and response were also not significantly changed in urinalysis, hematologic examination, or biochemical examination of blood(except for total cholesterol being up, total protein being up, and chloride ion being down in males), and blood coagulation time. For the relative weight measurement of organs, in the male group the weight change of both kidney and liver were increased in proportion to dose. In histopathological examination, nephropathy in the kidney(cystic change of renal tubules, regenerative tubule, inflammatory cell infiltration and necrosis in the interstitial tissue) was increased in a dose-dependent manner in the male group(290 ppm, 1,160 ppm, 4,640 ppm). However, other organs were not affected by the test substance. Conclusions: 2-methylpentane was estimated as a chemical causing nephropathy in the male group. NOAEL(No Observable Adverse Effect Level) in the female group is more than 4,640 ppm, while inthe male group it is less than 290 ppm.

Comparative Study to the Tribological Characteristics of Graphite Nano Lubricants after Thermal Degradation (그라파이트 나노윤활유의 열화 후 윤활 특성 비교 연구)

  • Lee, Jae-Keun;Lee, Chang-Gun;Hwang, Yu-Jin;Choi, Young-Min;Park, Min-Chan;Choi, Cheol;Oh, Je-Myung
    • Tribology and Lubricants
    • /
    • v.24 no.4
    • /
    • pp.190-195
    • /
    • 2008
  • Many researchers have tried to improve the tribological characteristics of lubricant by adding various nano particles in the base lubricant. But the reliability evaluation of the lubricants are rarely performed in its real operation condition. In this study, the physical property and the tribological characteristics of the graphite nano lubricant were evaluated and compared with raw lubricant after thermal degrading. In order to evaluate the tirbological characteristics, the disk-on-disk tribotester was adopted to measure the friction coefficient of the graphite nano lubricants. Also the temperature variations of friction surfaces were measured by the thermocouple installed on the fixed plate in the test chamber of the tribotester. The kinematic viscosity was measured using a capillary viscometer on the temperatures of 40, 60 and $80^{\circ}C$. The results showed that the graphite nano lubricant had lower friction coefficient and less wear on the friction surfaces than raw lubricant. After thermally degrading, the friction coefficients of graphite nano lubricant increased, but the friction coefficients after thermal degradation were still maintained lower than those of raw lubricant.

A Study on Wearing Test of Protective Clothing against a Toxic Substance (유해물질 차단을 위한 방호복의 착용실험에 관한 연구)

  • Chung, Myung-Hee;Park, Soon-Ja;Shin, Jung-Sook;Koshiba, Tomoko;Tamura, Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.11 s.158
    • /
    • pp.1626-1635
    • /
    • 2006
  • The purpose of this study was to search for comfortable protective clothing for waste incinerator workers. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric processed with charcoal with a 10% density (CF): and one whose outer side made use of polyolefine and polyamide films, and the inner side, a non-woven polypropylene fabric (NNCF). Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climate chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively. Measured were the rectal temperature, the skin temperature, the sweating rate, the weight loss, the heart rate, the blood pressure, the temperature, and the relative humidity of a microclimate and subjective sensation. These were measured within a period of 60 min, consisting of a 20-min stable period, a 20-min exercise period (walking exercise for 2 miles/hr on a treadmill), and a 20-min recovery period. Through this experiment, the differences between the human body's physiological reactions to CF and NNCF clothing, and the human body's comfort levels when wearing these, were determined.

Fan and Heater Management Schemes for Layer Filling and Mixing Drying of Rough Rice with Natural Air by Simulation (시뮬레이션에 의한 벼의 누적혼합 상온통풍건조의 송풍기 및 가열기의 운영방법에 관한 연구)

  • 금동혁;한충수;박춘우
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.229-244
    • /
    • 1998
  • This study was performed to determine proper fan and heater management schemes for natural air drying of rough rice in round steel bin with stirring device under Korean weather conditions. A computer simulation model was developed to predict moisture content changes, energy requirements, and drymatter losses during drying of rough rice by natural air. Drying test was conducted to validate the simulation model using round steel bin of holding capacity of 300ton at Rice Processing Complex in Jincheon. The bin was filled with rough rice every day and mixing by stirring device. Moisture contents, ambient air temperatures, relative humidities, static pressures in plenum chamber in the bin, airflow rates, and electrical and fuel energy were measured. Relative errors of moisture content changes predicted by the simulation model were below 5ft, and relative errors of final moisture content, final grain weight, required energy ranged from 0.9% to 6%. These not levels indicated that the simulation model can satisfactorily predict the performance factors of natural air drying system such as drying rates and energr consumptions comparing error level of 10% to 15% in other drying simulation models generally used in dryer desists. Twelve different fan and heater management schemes were evaluated using the computer simulation model based on three hourly weather data from Suweon for the period of 1952-1994. The best management schemes were selected comparing the drymatter losses, required drying times, required energy consumptions. Operating fan without heating only when ambient relative humidity was below 85% or 90% appeared to be the most effective method of In operation in favorable drying weather. Under adverse drying climates or to reduce required drying time, operating fan continuously, and heating air with $1.5^{\circ}C$ temperature rise only when ambient relative humidity was over 85% appeared to be the most suitable method.

  • PDF