• Title/Summary/Keyword: chamber sensitivity

Search Result 152, Processing Time 0.025 seconds

A Study of Ozone Passive Sampler(I)-Sensitivity on Filter Substrate (오존 간이측정기에 대한 연구(I)-필터의 민감도)

  • 정상진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.383-391
    • /
    • 2002
  • Six types of ozone passive samplers were fabricated with three different filter substrates and two colorants, and tested for their feasibility on atmospheric monitoring. These passive samplers are based on a colorant which fades (indigo carmine and ChromAir (K&M environmental Inc.)) or produces color (mixture of 3-methyl-2-benzothiazolinone acetone azine and 2-phenylphenol colorant) upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Three filters, namely Whatman No.1 paper, SG81 chromatography paper and Silica Gel coated on polyester (TLC Plates), were prepared and coated with two colorants. The response of these passive samplers in ozone chamber were tested and compared with ChromAir (K&M environmental Inc.) passive sampler. The response of Silica Gel filter impregnated with indigo carmine was the best at the constant concentration exposure.

Effects of the Method of Changing Compression Ratio on Engine Performance in an SI Engine (가솔린 엔진에서 압축비 변경 방법이 성능에 미치는 영향)

  • 이원근;엄인용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.27-33
    • /
    • 2001
  • In this study, it is observed that the distribution of combustion chamber volume affects the volumetric efficiency. The distribution ratio was adjusted by controlling combustion chamber volume of head and piston bowl one. Four cases were investigated, which are the combination of different distribution ratios and different compression ratios (9.8-10.0). A commercial SOHC 3-valve engine was modified by cutting the bottom face of the head and/or replacing the piston by the one that has different volume. The result shows that the less the head side volume, the more volumetric efficiency is achieved under the same compression ratio. It is also observed that increasing volumetric efficiency results in early knock occurrence due to increased "real" compression ratio. To consider reliability in estimating the volumetric efficiency, we examined the sensitivity of the AFR equation to possible errors in emission measurements. It is shown that the volumetric efficiency, which is calculated by measuring AFR and fuel consumption, can be controlled in 1% error. 1% error.

  • PDF

Studies on Erythropoietin Bioassay Method (Erythropoietin 검사법(檢査法)에 관(關)한 연구(硏究))

  • Cho, Kyoung-Sam;Ro, Heung-Kyu;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.2
    • /
    • pp.39-46
    • /
    • 1975
  • It is the purpose of this paper to design the most preferable method of erythropoietin bioassay in Korea. Bioassay utilizing polycythemic mice are currently in general use for the indirect determination of erythropoietin. Assay animals are usually prepared either by transfusion or by exposure to reduced oxygen tension in specially constructed chamber. We prepared the polycythemic, mice by the specially constructed hypobaric chamber. We observed weights and hematocrits of the mice in the hypobaric chamber, then hematocrits and 72 hours $^{59}Fe$ red cell upatke ratio of the polycythemic mice induced by hypoxia after removal from the hypobaric chamber. We designed the method of erythropoietin bioassay according to the results obtained by above experiments. Then we measured the 72 hours $^{59}Fe$ red cell uptake ratio of the polycythemic mice with normal saline, normal plasma and anemic plasma according to the method we designed. The results are followed: 1. The hematocrits of the mice in hypobaric chamber increased to 74% in 14 days It is preferable to maintain the pressure of the chamber to 400mmHg for first 4 days then 300mmHg for last 10 days to reduce the death rate and time consuming in hypobaric chamber. 2. After removal from the hypobaric chamber, the 72 hours $^{59}Fe$ red cell uptake ratio decreased rapidly and maintained the lowest level from the fourth day to tenth day. 3. We design the method of erythropoietin bioassay according to the results of above experiment and to the half life of erythropoietin. 4. The Korean product S9Fe is mixture of $^{59}Fe\;and\;^{55}Fe$. And the $^{59}Fe$ red cell uptake ratio in normal mice was far less with Korean product $^{59}Fe$ than with pure $^{59}Fe$ of foreign product. So it is desirable to use pure $^{59}Fe$ in this method of erythropoietin bioassay. 5. Considering the cost, the technique, the time consuming and the sensitivity it is the most preferable method of erythropoietin bioassay in Korea using hypobaric chamber to induce the polycythemia.

  • PDF

Sensing characteristics of Polypyrrole-based methanol sensors preparedbyin-situ vapor state polymerization

  • Linshu Jiang;Jun, Hee-Kwon;Hoh, Yong-Su;Lee, Duk-Dong;Huh, Jeung-Soo
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.137-137
    • /
    • 2003
  • Conducting PPy/PVA composite and pure PPy gas sensors were prepared by in-situ vaporstate polymerization method in a vaporization chamber under N2 condition, by exposing the pre-coated electrode with PVA/FeC13 to distilled pyrrole monomer. The various electrical sensing behaviors of both types of sensors were systematically investigated by a flow measuring system including mass flow controller (MFC) and bubbling bottle. The FT-Raman spectroscopy of vapor state polymerized PPy was identical to that of chemically polymerized PPy, confirming the same chemical structure. Both types of sensors had positive sensitivity when exposed to methanol gas. The sensitivity varied linearly with gas concentration in the range of 50ppm to 1059ppm. The detection limit of PPy/PVA sensor was believed to be as low as 10ppm. The sensitivity of PPy/PVA composite sensor was higher than that of pure PPy sensor. Both the response time and recovery time of PPy/PVA composite sensors were longer than those of pure PPy sensors. The thickness of the sensing film affected the sensitivity this way that the sensor having thinner film had higher sensitivity, indicating that the resistance of polymer film involved in the sensing behavior was bulk resistance rather than surface resistance. The reproducibility of PPy/PVA composite sensor was excellent during eight on-off cycles by switching between N2 and 3000ppm methanol gas. The sensitivity of PPy/PVA composite sensor was only maintained for two weeks, while the sensitivity of pure PPy sensor was maintained over two months.

  • PDF

Genetic variation of sensitivity to photoperiod and accumulated temperature in soybean mini core collection lines

  • Islam, Md Rasadul;Fujita, Daisuke;Zheng, Shao-Hui
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.77-77
    • /
    • 2017
  • The sensitivities to photoperiod and temperature give guidance to choose an adaptable genotype for specific area in soybean production. However, there is insufficient information about the variation of sensitivities to photoperiod and temperature with wide genetic background. We investigated the sensitivities to photoperiod and temperature using 82 soybean mini core collection lines provided by NIAS gene bank of Japan. The seeds were sown on 28 May and 4 August in 2015, 24 May and 5 August in 2016 at field in Saga, Japan ($33^{\circ}$ 14' 32'' N, $130^{\circ}$ 17' 28'' E) for the early (average photoperiod and temperature: 15.2 h and $25.1^{\circ}C$) and late (13.6 h and $27.2^{\circ}C$) sowing respectively. The plants were also grown in the growth chamber under 12 h photoperiod with three temperature regimes (day/night temperature: $25/18^{\circ}C$, $28/22^{\circ}C$ and $33/28^{\circ}C$). Emergence date, days to first flower were recorded with 10 plants in the field and 2 plants in the growth chamber for each line. The data for daily average temperatures and photoperiodic hours were collected from weather station. The days from emergence to first flower open (DEF) were varied from 23-92 (2015 and 2016) in early sowing whereas 18-68 (2015) and 18-59 (2016) in late sowing. The shortened DEF in late sowing could be caused by both short photoperiod and high temperature in late sowing. However, the accumulated temperatures during emergence to first flower open (ATEF) were less variable in comparison with DEF, suggesting the ATEF is dependent mostly on the photoperiod. The ATEF were found same between early and late sowing in some early flowering lines (e.g. $686.7^{\circ}C$ and $687.6^{\circ}C$ in HEUKDAELIPS, $728.8^{\circ}C$ and $706.3^{\circ}C$ in WILLIAMS'82) which indicated that these would be insensitive to day length. In the growth chamber experiment, the variation in both DEF and ATEF was a little greater at low temperature ($25/18^{\circ}C$) but almost same at middle ($28/22^{\circ}C$) and high ($33/28^{\circ}C$) temperatures. Since the less differences in ATEF were found between the three temperatures, it is suggested that the temperature plays only a quantitative effect on the flower initiation, and the large ATEF in some lines may indicate the stronger photosensitivity even at 12 h or longer juvenile phase. Some lines with the lowest ATEF regardless of growth conditions, such as FISKEBY V, KE 32 (ATEF: 559.6-666.5, 587.7-709.5) might lack the sensitivities to both photoperiod and temperature. The results suggested that soybean genotypes has wider variation in sensitivity to photoperiod, whereas less variation to temperature.

  • PDF

Sensitivity and Rejection Capability of Thermal Asperity Induced by Sub-Micron Contamination Particles (미세 입자에 의한 thermal asperity의 민감도 해석 및 감소 방안)

  • 좌성훈
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.6
    • /
    • pp.310-317
    • /
    • 2000
  • With use of (G)MR head, thermal asperity (TA) has been a big concern in drive industry. In this study, we investigated several factors of heads and disks which affects the TA sensitivity of the drive. TA experiments were conducted by introducing the particles on the drives using a particle injection chamber. It was found that the slider ABS shape can help to reduce TA or contamination in the head/media interface. However, TA sensitivity of the drive mainly depend on the intrinsic property of (G)MR sensor. GMR head is much less sensitive to TA compared with MR head. However, in case that the same bias current was applied for both of MR and GMR head, TA sensitivity of GMR head became almost identical to that of MR head. Therefore it was found that the bias current is a dominant factor in determining TA sensitivity of the head. TA sensitivity of different types of disks was also studied. The scratch resistance of the carbon overcoat layer is the one of the main factors which influence TA rejection capability of the disks.

  • PDF

236U accelerator mass spectrometry with a time-of-flight and energy detection system

  • Li Zheng;Hiroyuki Matsuzaki;Takeyasu Yamagata
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4636-4643
    • /
    • 2022
  • A time-of-flight and energy (TOF-E) detection system for the measurement of 236U accelerator mass spectrometry (AMS) has been developed to improve the 236U/238U sensitivity at Micro Analysis Laboratory, Tandem accelerator (MALT), The University of Tokyo. With observing TOF distribution of 235U, 236U and 238U, this TOF-E detection system has clearly separated 236U from the interference of 235U and 238U when measuring three kinds of uranium standards. In addition, we have developed a novel method combining kernel-based density estimation method and multi-Gaussian fitting method to estimate the 236U/238U sensitivity of the TOF-E detection system. Using this new estimation method, 3.4 × 10-12 of 236U/238U sensitivity and 1.9 ns of time resolution are obtained. 236U/238U sensitivity of TOF-E detection system has improved two orders of magnitude better than that of previous gas ionization chamber. Moreover, unknown species other than uranium isotopes were also observed in the measurement of a surface soil sample, which has demonstrated that TOF-E detection system has a higher sensitivity in particle identification. With its high sensibility in mass determination, this TOF-E detection system could also be used in other heavy isotope AMS.

The Effects of Some Environmental Factors on the Seed Germination of Albizzia julibrissin Durazz. (藪種 環境要因이 자귀나무의 種子發芽에 미치는 影響)

  • Lee, Ho Joon;Seon Ho Kim;Hae Won Kang
    • The Korean Journal of Ecology
    • /
    • v.8 no.2
    • /
    • pp.69-73
    • /
    • 1985
  • Germination respone to sulfuric acid treatment, temperature, light and underwater condition were experimented for Albizzia julibrissin Durazz. seed. It took 60 minutes to break the dormancy of impermeable seed for the effective sulfuric acid treatment, and temperature sensitivity was decreased by 90 minutes' treatment. The germination rate of the seed was highest, i.e. 96% at 60 minutes acid treatment in a 21。C growth chamber. On the occasion of light sensitivity, the seed was light indifferent. The imbibition rate of seed was higher at 27。C than 21。C and in proportion to the period of acid treatment time. A. julibrissin Durazz. seed were well germinated at underwagter condition.

  • PDF

A Study on the Influence of Design Parameters on the Automotive Shock Absorber Performance (차량용 충격흡수기의 설계변수에 따른 성능고찰)

  • 이춘태;이진걸
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.167-177
    • /
    • 2003
  • In this study, a mathematical nonlinear dynamic model is introduced to predict the damping force of automotive shock absorber. And 11 design parameters were proposed for the sensitivity analysis of damping force. Design parameters consist of 5 piston valve design parameters, 5 body valve design parameters and 1 initial pressure of reservoir chamber air. All of these design parameters are main design parameters of shock absorber in the procedure of shock absorber design. The simulation results of this paper offer qualitative information of damping force variation according to variation of design parameters. Therefore, simulation results of this paper can be usefully use in the design procedure of shock absorber

Automation of electrical acoustic experimental apparatus for the directivity measurement of sound (소리의 지향성 측정을 위한 전기음향실험기기의 자동화)

  • Jarng, Soon-Suck;Ko, Jae-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.574-576
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a sloping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF