• Title/Summary/Keyword: chair

Search Result 952, Processing Time 0.024 seconds

Trends of Industrial Injuries among Long-Term Health Care Workers in Korea (한국 요양보호사 산업재해의 연도별 변화추이)

  • Son, Mia;Jeon, Geo-Song;Bae, Dong-Chul;Son, Byungchang;Kim, Taeun;Yun, Jae-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.2
    • /
    • pp.156-172
    • /
    • 2021
  • Objectives: To investigate the trends of industrial injuries among long-term health care workers in Korea Methods: T7866 injuries were selected from the total industrial injuries approved by the Industrial Accident Compensation Insurance Act(Occupational Safety and Health Act) among long-term health care workers between 2007 and 2016 in Korea. We analyzied the trends of industrial injuries according to work process, occurrence type, and causes. Results: The industrial injuries among long-term health care workers increased since 2012. The mostly occurred area for industrial injuries were low back areas, which is related that the most serious industrial injuries occurred when the one long-term healthcare worker lift manually the recipient, from bed(ondol, Korean floor heating system) to a wheelchair, bed to bath bed, and wheelchair to bath chair. In addition to this, lack of workforce, increased work intensity due to overwork contributed the increasing of occupational injury. Conclusions: This study suggests that the main causes of industrial injuries were Lack of facilities and equipment for small private long-term care institutions, The physical load that goes into lifting the recipient directly, work intensity such as excessive workload and increased work speed. We suggest that the social publicization of long-term care service for the elderly, avoiding ways to lift recipients directly, introducing lifting machines as well as improving working methods, and reducing the workload of caregivers are required.

Two Polymorphs of Structures of $\alpha,\alpha$-Trehalose Octaacetate Monohydrate

  • Park, Young-Ja;Shin, Jung-Mi
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.2
    • /
    • pp.200-206
    • /
    • 1993
  • Structures of two polymorphs of ${\alpha},{\alpha}$-trehalose octaacetate monohydrate, $C_{28}H_{38}O_{19}\;{\cdot}\;H_2O$, have been studied by X-ray diffraction method. ${\alpha},{\alpha}$-trehalose (${\alpha}$-D-glucopyranosyl ${\alpha}$-D-glucopyranoside) is a nonreducing disaccharide. The polymorph I belongs to the monoclinic $P2_1$, and has unit cell parameters of a=10.725(l), b=15.110(4), c=11.199(5) ${\AA}$, ${\beta}=108.16(2)^{\circ}$ and Z=2. The polymorph II is orthorhombic $P2_12_12_1$, with a=13.684(4), b=15.802(4), c=17.990(9) ${\AA}$ and Z=4. The final R and R$_w$ values for monoclinic polymorph I are 0.043 and 0.048 and for orthorhombic polymorph II are 0.116 and 0.118, respectively. Those R values of polymorph II are high because the large thermal motions of acetyl groups and the poor quality of the crystal. The molecular conformations in the two polymorphs are similar. Both D-glucopyranosyl rings have chair $^4C_1$ conformations and atoms of glycosidic chain ${\alpha}(1{\rightarrow}1)$ linkage are coplanar. The primary acetate groups of the pyranose residues assume both gauche-trans conformations. The molecules of two polymorphs have pseudo-C$_2$ symmetry at glycosidic O(1) atom. The bond lengths and angles are normal compared with those in other acetylated sugar compounds. The molecules in the monoclinic crystal are held by the hydrogen bonds with the water molecules and by van der Waals forces.

Effects of Muscle Activity and Muscle Strength According to Verbal Command Volume in Isokinetic and Isometric Exercise of Quadriceps (넙다리네갈래근의 등속성 및 등척성 운동에서 구두명령 크기에 따른 근 활성도와 근력에 미치는 영향)

  • Lee, Hyoungsoo;Kim, Yoonhwan
    • Archives of Orthopedic and Sports Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.45-53
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of muscle activity and muscle strength according to verbal command volume during isokinetic and isometric quadricep exercises. Methods: To measure muscle activity and muscle strength, surface electrodes were attached to the participants, as they sat on a Biodex chair. The isometric exercise was performed three times, with maximum exercise at $30^{\circ}$ bending angle, based on a maximum extension state of the knee at $0^{\circ}$. The average holding time was unified to three seconds. In addition, the isokinetic exercise was performed three times, at $60^{\circ}/sec$. The verbal command ranged between 0∾60 dB and 0∾75 dB. Muscle activity was measured using surface electromyography (4D-MT, Relive, Gimhae, Korea). The Biodex System 4 was used to measure the isometric and isokinetic strength of the nodal line, and 4D-MT was used to measure muscle activity. Results: There were significant improvements in the maximal and relative muscle strengths, when the 0∾ 60 dB and 0∾75 dB verbal commands were applied with isokinetic extension/flexion (p<.05). The isokinetic exercise (0∾75 dB) group showed a significant difference in the vastus medialis oblique muscle activity change (p<.05), while the isometric exercise (0∾75 dB) group showed a significant difference in the rectus femoris muscle activity change (p<.05). Conclusions: Our results reveal that verbal commands effectively improve muscle activity and muscle strength during isokinetic and isometric quadricep exercises.

Relationship Between a New Functional Evaluation Model and the Fugle-Meyer Assessment Scale for Evaluating the Upper Extremities of Stroke Patients

  • Kim, Jung-Hyun;Kim, Hyun-Jin;Lee, Seung-Gu;Song, Chang-Ho
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.305-313
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the relationship between a functional evaluation model and the Fugl-Meyer assessment (FMA) scale in evaluating the upper extremities of stroke patients Methods: Thirty-eight stroke patients were evaluated using the FMA and performed reaching and grasping motions using a three-dimensional motion analysis (Qquas 1 series, Qualisys AB, Sweden). The participants sat on a chair with a backrest. The position of the cup was located at a distance of 80% to the front arm length. The markers were attached to the sternum, acromion, elbow lateral epicondyle, ulnar styloid process, three metacarpal heads, and the distal phalanges of the thumb and index finger. The variables of the correlation between the functional evaluation model and the FMA scale were analyzed. Multiple regression (stepwise) was used to investigate the effect of the kinematic variables. Results: A significant negative correlation was found between the movement time (p < 0.05), movement unit (p < 0.05), and trunk displacement values (p < 0.05) in the FMA total scores, while a positive correlation was found between the peak velocity (p < 0.05) and maximum grip aperture values (p < 0.05). As a result of the multiple regression analysis, the most significant factor was the movement unit, followed by the general movement assessment and trunk displacement. The explained FMA total score value was 62%. Conclusion: This study presents a new functional evaluation model for assessing the reaching and grasping ability of stroke patients. The factors of the proposed functional evaluation model showed significant correlations with the FMA scale scores and confirmed that the new functional evaluation model explained the FMA by 67%. This suggests a new functional evaluation model for reaching and grasping stroke patients.

Usability Test of Rollator Walkers and Effect of Rollator Walkers on The Lives of The Senior Citizens (보행보조차의 사용성평가와 고령자의 생활에 미치는 영향)

  • Kang, Sua;Kim, Soohyun;Park, Chiwook;Sin, Hyewon;Lee, Jiyoung;Lee, Hyowon;Jeong, Myeongjin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.385-390
    • /
    • 2021
  • This study aims to provide primary data for R&D on rollator-walking frame through researching the usability test of the rollator-walking frame and the effect of rollator-walking frames on the lives of senior citizens. This study surveyed 60 senior citizens living in Sungnam City in South Korea. As the result of the usability test, we can find users' dissatisfaction with the folding, weight, shape of backrest and material of chair. The survey shows that the frequency of outdoor activity is mostly increased by the convenience of product. However, the inconvenience while using facilities, such as elevators or public transportations, gave a significant impact on the decrease in going out experiences. Therefore, for better outside lifestyle of senior citizens, it is important to improve the function of the product, however, we need to make improvement of urban infrastructure.

Dental hygienist's knowledge measurement tool for emergency treatment related to systemic disease (치과위생사의 전신질환과 관련된 응급처치 지식 측정도구 개발)

  • Yoon, Yong-Ha;Lee, Jung-Hwa;Noh, Hie-Jin;Han, Sun-Young;Mun, So-Jung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.133-142
    • /
    • 2022
  • Objectives: This study was conducted by clinical dentistry hygienists to develop knowledge measurement tools and evaluate knowledge necessary to cope with emergencies related to systemic diseases occurring in dentistry. Methods: Basic questions were developed on the six most frequently occurring diseases in the dental office: diabetes, syncope, respiratory disease, coronary artery disease, cerebrovascular disease, and epilepsy. Fifty-eight preliminary questions were composed in a survey format through expert validation. The survey was then conducted on 290 dental hygienists to verify the composition validity and reliability. Factor and reliability analyses were performed using the SPSS 23.0 program, and the correct answer rate for each question was calculated. Results: 49 items of a total of 13 factors were adopted as the final items for signs, symptoms, prevention and treatment of five diseases. The question with the highest percentage of correct answers for each question was "Slowly set up the unit chair when raising the patient"(97.9%) during the prevention of unconsciousness and question with the lowest correct answer rate was "soft substances such as cloth should be put in the mouth to prevent trauma while the seizure persists" (16.6%). Conclusions: A total of 49 questions have been developed as tools to measure the knowledge of dental hygienists' first aid related to systemic diseases and it is expected that related curriculum can be operated or evaluated by using them.

Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based

  • Graf, Tobias;Guth, Jan-Frederik;Diegritz, Christian;Liebermann, Anja;Schweiger, Josef;Schubert, Oliver
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.351-360
    • /
    • 2021
  • PURPOSE. The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS. A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS. Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 ㎛ in group CF and 34 ± 6 ㎛ in group PC. RMSE of total adjustments was 61 ± 11 ㎛ in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION. Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.

Correlation Analysis of Pelvic Tilt and Gait according to the Paralytic Side of Stroke Patients (뇌졸중 환자의 마비쪽에 따른 골반의 기울임과 보행의 상관관계 분석)

  • Yong Seon, Lee;Jong-Hyuk, Yun
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.4
    • /
    • pp.111-120
    • /
    • 2022
  • Objective: This study investigated the effect of pelvic tiltng according to the paralytic side on gait in stroke patients during a 10 m functional movement timed up and go (TUG) test. Method: In this study, gait parameters were measured using a gait analyzer for 20 stroke patients and their gait was analyzed during a 10 m TUG test. For statistical analysis, an independent sample t-test were performed for age, height, and weight among general characteristics of subjects and homogeneity was tested by performing a chi-square test for gender, paralysis side, period of onset, and K-MMSE score. In order to understand the relationship between each variable, Pearson correlation analysis was performed on the variables. Results: First, the right-hand paralyzed group showed correlations in cadence and gait velocity in the up and down tilt of the pelvis, and the left-hand paralyzed group showed correlations in cadence and step length in the anterior and posterior tilt of the pelvis. Second, the tilt of the pelvis was correlated with the Sit to stand, walk forward, walk backwards, turn around at the end point, sit on a chair and the total TUG time in the right hemiplegic group compared to the left hemiplegic group. Conclusion: In this study, a significant correlation was confirmed as a result of gait analysis of right-handed stroke patients divided into a right paraplegic group and a left paraplegic group. In the future, it is suggested that treatment for improving gait of stroke patients should be treated differently for the right and left paralyzed side.

Implementation of a Sensor to Detect the Foot-pushing Force for an Agricultural Transport-convenience Vehicle (농업용 이동편의장치를 위한 발로 미는 힘을 감지하는 센서 구현)

  • Seung-hee, Baek;Ik-hyun, Kwon;Cheong-worl, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.411-417
    • /
    • 2022
  • In this paper, we propose a sensor with a C-shaped load cell to detect force change when a person sitting on the chair in an electrical transport-convenience vehicle is pushing ground by both heels. The load cell built in the vehicle is mechanically deformed by the vertical force owing to the human weight and the horizontal force by ground-pushing feet. The deformation rate of the load cell and its distribution are simulated using finite element analysis. In the simulation, the applied loads are preset in the range of 10 kg - 100 kg with a step size of 10 kg, and the ground-pushing force by feet is increased to 40 N with a step size of 5 N with respect to each applied load level. The resistance change of the load cell was observed to be linear in simulation as well as in measurement. the maximum difference between simulation and measurement was 0.89 % when the strain gauge constant was 2.243. The constant has a large influence on the difference. The proposed sensor was fabricated by connecting an instrument amplifier and a microcontroller to a load cell and used to detect the force by ground-pushing feet. To detect foot driving, the reference signal was set to 130% of the load, and the duration of the sensor output signal exceeding the reference signal was set to 0.6 s. In a test of a vehicle built with the proposed sensor, the footpushing force by the worker could be successfully detected even when the worker was working.

Center of Pressure and Ground Reaction Force Analysis of Task-oriented Sit-to-stand in Stroke Patients (뇌졸중 환자의 과제지향적 일어서기 시 신체압력중심과 지면반발력 특성 )

  • Yoo-Jung, Lim;Joong-Hwi, Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.45-52
    • /
    • 2022
  • PURPOSE: This study examined the center of pressure (COP) and ground reaction force (GRF) characteristics during each task-oriented sit-to-stand in stroke patients. METHODS: Twenty stroke subjects were included in this study. The task consisted of sit-to-stand (SS), sit-to-stand for reaching (SR), and sit-to-stand for walking (SW). The response time, COP, and GRF were measured during each task. The COP and GRF data were obtained using a two-force plate. The force plates were placed on a chair (below the buttock) and floor (below the feet). RESULTS: Significant differences were observed between SS (1.48 ± .48 s) and SR (2.09 ± 0.82 s) and between SS and SW (2.27 ± .72 s) in the preparatory phase time during each sit-to-stand exercise (p = .002) and showed significant differences between SS (13.90 ± 6.44 cm) and SW (34.62 ± 39.38 cm) and between SR (16.14 ± 8.04 cm) and SW in the mediolateral COP range during each sit-to-stand exercise (p = .013). CONCLUSION: These findings suggest that more complex task-oriented sit-to-stand exercise requires a high-level motor programming process than a simple sit-to-stand task. Therefore, a variety of tasks-oriented sit-to-stand exercises will be useful training to achieve better ADL ability for stroke patients.