• Title/Summary/Keyword: central line

Search Result 917, Processing Time 0.043 seconds

Determination of stress state in chip formation zone by central slip-line field

  • Andrey Toropov;Ko, Sung-Lim
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.577-580
    • /
    • 2003
  • Stress state of chip formation zone is one of the main problems in metal cutting mechanics. In two-dimensional case this process is usually considered as consistent shears of work material along single of several shear surfaces. separating chip from workpiece. These shear planes are assumed to be trajectories of maximum shear stress forming corresponding slip-line field. This paper suggests new approach to the constriction of slip-line field, which Implies uniform compression in chip formation zone. On the base of given model it has been found that imaginary shear line in orthogonal cutting is close to the trajectory of maximum normal stress and the problem about its determination have been considered. It has been shown that there is a second central slip-line field inside chip, which corresponds well to experimental data about stress distribution on tool rake face and tool-chip contact length. The suggested model could be useful in solution of various problems of machining.

  • PDF

Development of a Remote Central Monitoring System of Street Lights (가로등 원격감시 중앙관제시스템 개발)

  • Ha, Kwan-Yong;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.43-45
    • /
    • 2004
  • A remote monitoring system was developed to improve inconveniences of manual work such as monitoring street lights by using current sensors, microprocessor and RF communication system. In order to control the street lights on the roads effectively and monitor them in real time, we can attach current sensor to the street lights which monitors Lamp, the broken part and state of the Balast, and the amount of an electric leak precisely we developed a system which makes it possible to transmit the data on monitoring results in breakdown of street lights and Balasts to the central monitoring computer without setting up extra data transmission line. The system we devised can transmit data through Power Line Modem and RF communication using relay method to the central controlling computer without any loss of data.

  • PDF

On the Optimization of the Coaxial-Conical-Radial Type Power Divider/Combiner and the Improvement of Isolation Characteristics (동축-원추-방사형 전력분할/합성기의 중심부 높이에 따른 최적설계와 아이솔레이션 특성 향상)

  • Choi, Young-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1727-1732
    • /
    • 2011
  • In order to realize a high performance(low loss, high isolation) microwave power divider/combiner, we have designed the power combiner/divider precisely in accordance with the different hight of central part. In the case of the high central part of the hight of $h_r$=10.2, a compensating part of the conical line is inserted in the conical conversion transmission line, and in the case of low central part of the hight of $h_r$=5.0, the conical conversion transmission line is remodeled into the 2-stage bend structure. In both case, the reflection characteristics are improved to 30dB over the operating frequency range of 5GHz bandwidth. A resistance is inserted between the peripheral ports so as to try to improve the isolation characteristics of the device. For the 16-divider/combiner, the isolation characteristics are improved to 10dB over the operating frequency range of 5GHz bandwidth.

Two-Year Hospital-Wide Surveillance of Central Line-Associated Bloodstream Infections in a Korean Hospital

  • Seo, Hye Kyung;Hwang, Joo-Hee;Shin, Myoung Jin;Kim, Su young;Song, Kyoung-Ho;Kim, Eu Suk;Kim, Hong Bin
    • Journal of Korean Medical Science
    • /
    • v.33 no.45
    • /
    • pp.280.1-280.9
    • /
    • 2018
  • Background: Surveillance and interventions of central line-associated bloodstream infections (CLABSIs) had mainly been targeted in intensive care units (ICUs). Central lines are increasingly used outside ICUs. Therefore, we performed a hospital-wide survey of CLABSIs to evaluate the current status and develop strategies to reduce CLBASI rates. Methods: All hospitalized patients with central venous catheters (CVCs) were screened for CLABSIs from January 2014 through December 2015 at a 1,328 bed tertiary care teaching hospital in Korea using an electronic data-collecting system. Clinical information including type of CVC was collected. CLABSI rates were calculated using the definitions of the National Health and Safety Network after excluding mucosal barrier injury laboratory-confirmed bloodstream infection (BSI). Results: A total of 154 CLABSIs were identified, of which 72 (46.8%) occurred in general wards and 82 (53.2%) in ICUs (0.81 and 2.71 per 1,000 catheter days), respectively. Nontunneled CVCs were most common (68.6%) among 70 CLABSI events diagnosed within one week of their maintenance. On the other hand, tunneled CVCs and peripherally inserted central catheters (PICCs) were more common (60.5%) among 114 CLABSI events diagnosed more than a week after maintenance. Whereas the majority (72.2%) of CLABSIs in ICUs were associated with non-tunneled CVCs, tunneled CVCs (38.9%) and PICCs (36.8%) were more common in general wards. Conclusion: CLABSIs are less common in general wards than in ICUs, but they are more often associated with long-term indwelling catheters. Therefore, interventions to prevent CLABSIs should be tailored according to the type of ward and type of catheter.

High density line patterns fabricated by thermal imprint (Thermal imprint를 이용한 고밀도 line패턴 형성방법)

  • Lee, Sang-Moon;Kwak, Jung-Bok;Lee, Hwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.270-270
    • /
    • 2008
  • We present details of experimental results in the fabrication of high density line patterns, using imprint technique that can provide a simple and comparatively cost-effective manufacturing means. Barrier array structures for display or interconnects for semiconductor applications were the aims of this study. For pattern fabrication, a polymer layer (Ajinomoto GX-13 dielectric film) with a thickness of 38um that can act as either an insulating or a dielectric layer was laminated on a substrate. Fine tracks were then formed using a patterned stamp under isostatic pressure. The line width was ranged between 10 to 60 mm. A self-assembled monolayer (SAM) of fluorinated alkylchlorosilane [$CF_3(CF_2)5(CH_2)2SiCl_3$] as an anti-sticking layer was coated on the surface of the stamp prior to thermal imprint to improve the de-molding characteristic.

  • PDF

Expression of Heterotic Genetic Interaction among Multivoltine Recurrent Backcross/Congenic Lines for Higher Shell Weight of Silkworm, Bombyx mori L.

  • Verma, A.K.;Chattopadhyay, G.K.;Sengupta, M.;Sengupta, A.K.;Das, S.K.;Urs, S.Raje
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.7 no.1
    • /
    • pp.21-27
    • /
    • 2003
  • Manifestation of heterotic genetic interaction was studied in different hybrids made between multivoltine recurrent backcross (RBL)/congenic lines (Con. L) during unfavourable season when temperature and relative humidity are > $30^{\circ}C$ and 86%, respectively. A few number of silkworm race or strain or breed like Nistari (N + p or Np) can sustain the temperature above 3$0^{\circ}C$ and RH above 86%. The present heterosis study screened a hybrid i.e., CB$_{5}$Lm5RBL1M$_{6}$DPC-LmE$^1$RBL and its reciprocal provided heterobeltiotic effect on survival by number and pupation rate at a magnitude of 20% (p < 0.01) and yield by weight of 10% (p < 0.01). Beside all the hybrids expressed heterosis over check - Nistari (N + p) with better quality silk. Therefore, aforesaid hybrid may be useful for utilization at commercial level during adverse seasons of West Bengal.gal.

Regulation of Genetic Aggression by Central Dopamine System - Plurality of Dopamine Receptor -

  • Lee, Soon-Chul
    • Archives of Pharmacal Research
    • /
    • v.14 no.2
    • /
    • pp.109-113
    • /
    • 1991
  • Two types of aggressive behavior were produced by selective breeding in ICR mimce. NC900 line mice exhibited high level of species-typical, isolation-induced aggression, conversely, NC100 line mice exhibited little aggression. The present study tested the hypothesis that these differences involved brain monoamine systems. Comparisons of microdissected samples from various brain regions showed that NC100 line mice had significantly lower concentrations of dopamine. DOPAC and HVA in the nucleus accumbens (NAB) and caudate nucleus (NCU) than NC900 line. Homogenate binding studies demonstrated that NC100 mice had significantly increased density of $D_1$ dopamine receptor, but not $D_2$ dopamine receptor in the caudate nucleus. These results support the hypothesis that central dopamine pathways play an important role in modulating the genetically selected differences in aggressive behavior, and of which intensity differs from TEX>$D_1$\;and\;$D_2$ dopamine receptors.

  • PDF

Computations of Line Reactor Parameters and DC Bus Capacitance for Inverter (인버터의 선형 리액터 파라미터와 DC 버스 용량 계산)

  • Chen, Dezhi;Chai, Wenping;Kwon, Byung-il
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.968-969
    • /
    • 2015
  • This paper proposes a novel analysis method for calculating inverter DC bus capacitance and line reactor parameters. In the realization process, DC bus capacitance parameter, and ripple current, life of DC bus capacitor, interaction between DC bus capacitance can be calculated by using Newton-Raphson procedure. The design scheme of DC bus capacitor and line reactor, specific parameters such as capacitance, loss, ripple current, central average temperature, life, ripple current, loss, size, central temperature of the reactor were given. Simulation results show that this scheme can accurately calculate the DC bus capacitance and line reactor parameters. Compared with calculation result of references, cost and volume are half. The indicators meet the demand of practical engineering. It had affirmed precision of the analytical method and verified correctness and feasibility of this method.

  • PDF

The Galactic Center: Not an Active Galactic Nucleus

  • An, Deokkeun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.58.1-58.1
    • /
    • 2013
  • We present $10{\mu}m-35{\mu}m$ Spitzer spectra of the interstellar medium in the Central Molecular Zone (CMZ), the central 210 pc ${\times}$ 60 pc of the Galactic center (GC). We present maps of the CMZ in ionic and $H_2$ emission, covering a more extensive area than earlier spectroscopic surveys in this region. The radial velocities and intensities of ionic lines and $H_2$ suggest that most of the $H_2$ 0-0 S(0) emission comes from gas along the line-of-sight, as found by previous work. We compare diagnostic line ratios measured in the Spitzer Infrared Nearby Galaxies Survey (SINGS) to our data. Previous work shows that forbidden line ratios can distinguish star-forming galaxies from LINERs and AGNs. Our GC line ratios agree with star-forming galaxies and not with LINERs or AGNs.

  • PDF