• 제목/요약/키워드: central heating

검색결과 205건 처리시간 0.024초

온수분배기용 유량제어밸브의 개발 (Development of Flow Control Valves for Hot Water Distribution Manifolds)

  • 권우철;윤준용;유선학
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

유도 가열을 이용한 강판의 곡면 성형 시뮬레이션 (Simulation of Curved Surface Forming of Steel Plate by Induction Heating)

  • 유현수;김호경;고대은
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4381-4387
    • /
    • 2015
  • 선체의 외판은 복잡한 곡면 형상이며 대부분의 조선소에서는 이의 제작을 위해 가스 토치를 이용한 선상 가열 방법을 사용하고 있다. 가스 토치를 이용한 전통적인 선상 가열 방법은 입열량의 제어가 어려울 뿐만 아니라 고압의 가스 분출에 따른 소음과 대기 오염 등 열악한 작업 환경의 문제점을 안고 있다. 최근에는 입열량의 제어가 비교적 용이하고 친환경적인 고주파 유도 가열에 주목하여 이를 가열 열원으로 하는 강판의 성형 자동화 연구들이 진행되고 있다. 본 연구에서는 강판의 곡면 성형을 위한 유도 가열 시뮬레이션 방법을 개발하였으며 유도 가열 실험 결과와 비교하여 그 유효성을 검증하였다. 개발된 유도 가열 시뮬레이션 방법은 효율적인 유도 가열 코일 설계와 최적 성형 조건 산출 등 유도 가열을 이용한 선체 외판의 곡가공 자동화 시스템 개발에 유용한 해석적 툴로 활용될 수 있을 것으로 기대된다.

Comparison of Pyrolysis Patterns of Different Tobacco Leaves by Double-Shot Pyrolysis-GC/MSD Method

  • Lee, Chang-Gook;Lee, Jae-Gon;Jang, Hee-Jin;Kwon, Young-Ju;Lee, Jang-Mi;Kwag, Jae-Jin;Kim, Soo-Ho;Sung, Yong-Joo;Shin, Chang-Ho;Kim, Kun-Soo;Rhee, Moon-Soo
    • 한국연초학회지
    • /
    • 제30권2호
    • /
    • pp.94-102
    • /
    • 2008
  • In this paper, we describe our study on the characterization of tobacco leaves by their pyrolysis patterns. Two kinds of tobacco leaves were pyrolyzed and analyzed by Double-Shot Pyrolysis-Gas Chromatography/Mass Spectroscopy (Py-GC/MS) methods. Three grades of Korean flue-cured tobacco leafsuch as B1O, AB3O, CD3L and burley tobacco leaves such as B1T, AB3T, CD3W were pyrolyzed with six discrete but stepwise heating temperature ranges, those are from 100$^{\circ}C$ to 150$^{\circ}C$, 150$^{\circ}C$ to 200$^{\circ}C$, 200$^{\circ}C$ to 250$^{\circ}C$, 250$^{\circ}C$ to 300$^{\circ}C$, 300$^{\circ}C$ to 350$^{\circ}C$ and finally from 350$^{\circ}C$ to 400$^{\circ}C$. Using the resultant 52 pyrolytic components identified in the programs as components, principal component analysis (PCA) showed statistical classification between flue-cured and burley tobacco lamina. Among six pyrolysis temperature ranges, the best discrimination was achieved at the temperature range from 250$^{\circ}C$ to 300$^{\circ}C$ and from 300$^{\circ}C$ to 350$^{\circ}C$.

건축물에너지효율등급 평가프로그램에 의한 공동주택 난방에너지 소요량과 실제 사용량 비교 (Comparing the actual heating energy with calculated energy by the amended standard building energy rating system for apartment buildings)

  • 이아람;김정국;김종훈;정학근;장철용;송규동
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.103-107
    • /
    • 2015
  • Purpose: Since September 1st, 2013, subjects of the evaluation have been expanded, and the evaluation standard has been detailed to enable Building energy rating system for all buildings. Accordingly, the new evaluation program (ECO2) has been developed, and therefore, apartment applied after September 1st, 2013 were evaluated with the new evaluation program. Therefore, this research suggests the improvement plan to figure out reasons for the evaluation result calculation and to calculate the evaluation results close to the actual energy usage by analyzing and comparing primary energy consumption as a result of the new evaluation program (ECO2) and actual heating energy usage on the same building. Method: When comparing evaluation results of the new evaluation program (ECO2) and actual heating energy usage, the tendency was similar but different. Also when comparing seasonally, the tendency was similar, but the different between actual heating energy usage and primary energy consumption during winter is greater than during spring or fall, and when comparing seasonal electric usage, heating alternatives were used through increased electrical usage during winter compared to during spring or fall. Result: Therefore, when evaluating apartment with the new program (ECO2) in the future, evaluation items relevant to the use of heating alternatives should be added, and the modification factor should be added according to the region. Based on the evaluation results of the research and actual energy usage, the Modification factors of the central part and the southern part were calculated respectively as 0.5 and 0.8.

부분부하 특성을 고려한 열원기기의 운전성능 평가 (EA Study on the Operation Performance of Central Plant Equipment According to Part Load Characteristics)

  • 이왕제;강은철;이의준;오병칠;신우철
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.392-397
    • /
    • 2013
  • To fulfill the demands concerning energy efficiency for zero energy buildings, various technologies of architects and engineers are required. This study aims to estimate the thermal performance of heat source equipment in which part load characteristics are considered in an office building. Overestimation of heat source equipment was reviewed through literature survey, and heating and cooling loads depending on the capacity and division of the equipment were analyzed through a simulation program (DOE-2.1E). The conclusions gained from this study are as follows; 1) The more the division of equipment, the less the heating and cooling energy consumption. 2) When a large item of equipment is divided into two small items of equipment, the optimum application rate showed as 5:5 for chiller, and 7:3 for boiler, respectively.

러시아 거주 고려인의 주거에 관한 연구 -연해주 (Yunhaju: 연해주) 지역을 중심으로- (A Study on the Dwellings of Korean Diaspora in Yunhaju of Russia)

  • 이영심;조재순
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.51-62
    • /
    • 2004
  • Koreans had started moving to Yunhaju in Russia for escaping from the tyrannical rule and famine in 1860's in Korea. It had been veiled and nearly known about Korean's life there because of social and political situation of Russia until the Perestroyka. This study examined the dwellings of Korean Diaspora in Yunhaju through visiting their houses and having an interview. Results of research were as following: 1) Russian traditional houses which Koreans built was followed by Russian style basically and Koreans used the space slightly different way. Korean Diaspora have been adopted Russian life style with keeping their own traditional way of living. 2) Some Korean Diaspora still have been kept traditional heating system 'Ondol' in their houses until now in Yunhaju. Moreover over, it is known that people of Central Asia prefer to set 'Ondol' recently as a very specific and expensive heating system. 3) Korean's food style in Yunhaju is the one mixed with Russian, Korean, and Central Asian foods. This study could be a first step to supply for a basic information for studying of Korean Diaspora in Russia and it is needed to take more deep research in other areas in Russia.

지역난방용 매설배관의 열응력 흡수에 관한 연구 (A Study on the Absorption of Thermal Stress on the Underground piping for the District heating)

  • 공재향;신병국
    • 한국공작기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.81-88
    • /
    • 2005
  • There have been many studies on generation equipment and plant piping, but there is no significant study result on the heat transportation pipe. As such, this study established basic theory on the compensated method among buried pipe for regional heating, and further obtained the following results by applying the conditions of AGFW and NCHPP respectively in calculation of friction and maximum installation distance for the buried pipe. Friction coefficient according to the types and physical properties of soil, friction and maximum installation distance were compared to set the application value of friction coefficient according to the location of works. Calculation formula of clay load to be applied for calculation of friction was introduced to the formula of AGFW and the formula of NCHPP that has been used in Nowon district since 1997 to determine the difference and applicability. $120^{\circ}C$ and $95^{\circ}C$ were applied in temperature difference for expansion volume to compare the arm length at the curve pipe so thai it can be reflected in the design in the future. Maximum installation distance according to thickness of pipe was compared to present the necessity of unified specification so that same kinds of pipe materials can be used for same kinds of works.

건물일체형 지열히트펌프시스템의 난방 성능 분석 (Heating Performance Analysis of Building Integrated Geothermal System)

  • 김상진;이진욱;김태연;이승복
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.206-210
    • /
    • 2012
  • Ground source heat pump is a central heating and cooling system that pumps heat to or from the ground. Building Integrated Geothermal system used in this experiment is one of the Ground Source Heat Pump Systems which utilize energy pile. The purpose of this study is to evaluate heating performance of the system. The building is a low-energy experiment apartment in Yonsei University Songdo Campus and the subject is one of the energy reduced houses in this apartment. In the experiment, indoor temperature, outdoor temperature and the inlet and outlet temperature of ground heat exchanger and subject model, were measured. Then the heat pump's Coefficient of performance(COP) of the heat pump was calculated. As a result, the COP of heat pump is 4-5. Although the depth of the ground heat exchanger in this experiment is shallower than usual heat exchanger, the result of heating performance of this system was good as well.

  • PDF

중앙집중난방방식 공동주택의 난방열량 계량 및 요금부과방안 연구 (A Study on the Metering and the Rating Methods of Heat in Apartment Houses with Centralized Heating System)

  • 이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.27-32
    • /
    • 2009
  • The measuring apparatus such as heat meter is legally obliged to be installed and used for heat rating with heat or flow rate in residential buildings in Korea. There are two kinds of apparatus to measure heat consumed at each households, i.e., heat meter and hot water flowmeter. Contrast to the most of buildings with hot water flowmeter well being used for rating, heat meters have been used only 42.6% in the buildings with central heating system. But there is a critical problem in the course of using hot water flowmeter for heat rating, yielding distorted and unfair result which is different from the real value of heat supplied. Experiments with several parameters were carried out in this study to analyze this phenomenon quantively and alternative methods were proposed for rational heat rating.

  • PDF