• 제목/요약/키워드: central heating

검색결과 205건 처리시간 0.023초

다목적 복합건물의 하절기 열원기기 운전시 소비전력에 관한 시뮬레이션 (Simulation on Energy Consumption in the Summer Season Operation of primary HVAC system for Multipurpose Building Complex)

  • 서재경;최승길;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.903-908
    • /
    • 2006
  • Building energy simulation has become a useful tool for predicting cooling, heating and air-conditioning loads for facilities. It is important to provide building energy performances feed back to the mechanical and electrical system operator and engineer for energy conservation and maintenance of building. From this research, we set up the typical weather data of location, basic description of building, geometric modelling data and the specification of Installed primary HVAC system for establishing the simulation model about energy consuming that take place in multipurpose building complex. The simulation tool of building energy - EnergyPlus (DOE and BLAST based simulation S/W), it has been used and accomplished calculations and analyses for evaluating the effect of the system types and operating condition of central HVAC plant on the building energy consumption. In this paper, we offer comparison and simultaneous results those involve electricity consumption pattern and amount between actual operation versus EnergyPlus simulation to the object building during summer season.

  • PDF

Optimizing slow pyrolysis of banana peels wastes using response surface methodology

  • Omulo, Godfrey;Banadda, Noble;Kabenge, Isa;Seay, Jeffrey
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.354-361
    • /
    • 2019
  • Renewable energy from biomass and biodegradable wastes can significantly supplement the global energy demand if properly harnessed. Pyrolysis is the most profound modern technique that has proved effective and efficient in the energy conversion of biomass to yield various products like bio-oil, biochar, and syngas. This study focuses on optimization of slow pyrolysis of banana peels waste to yield banana peels vinegar, tar and biochar as bio-infrastructure products. Response surface methodology using central composite design was used to determine the optimum conditions for the banana wastes using a batch reactor pyrolysis system. Three factors namely heating temperature ($350-550^{\circ}C$), sample mass (200-800 g) and residence time (45-90 min) were varied with a total of 20 individual experiments. The optimal conditions for wood vinegar yield (48.01%) were $362.6^{\circ}C$, 989.9 g and 104.2 min for peels and biochar yield (30.10%) were $585.9^{\circ}C$, 989.9 g and 104.2 min. The slow pyrolysis showed significant energy conversion efficiencies of about 90% at p-value ${\leq}0.05$. These research findings are of primary importance to Uganda considering the abundant banana wastes amounting to 17.5 million tonnes generated annually, thus using them as pyrolysis feedstock can boost the country's energy status.

Thermal stress intensity factor solutions for reactor pressure vessel nozzles

  • Jeong, Si-Hwa;Chung, Kyung-Seok;Ma, Wan-Jun;Yang, Jun-Seog;Choi, Jae-Boong;Kim, Moon Ki
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2188-2197
    • /
    • 2022
  • To ensure the safety margin of a reactor pressure vessel (RPV) under normal operating conditions, it is regulated through the pressure-temperature (P-T) limit curve. The stress intensity factor (SIF) obtained by the internal pressure and thermal load should be obtained through crack analysis of the nozzle corner crack in advance to generate the P-T limit curve for the nozzle. In the ASME code Section XI, Appendix G, the SIF via the internal pressure for the nozzle corner crack is expressed as a function of the cooling or heating rate, and the wall thickness, however, the SIF via the thermal load is presented as a polynomial format based on the stress linearization analysis results. Inevitably, the SIF can only be obtained through finite element (FE) analysis. In this paper, simple prediction equations of the SIF via the thermal load under, cool-down and heat-up conditions are presented. For the Korean standard nuclear power plant, three geometric variables were set and 72 cases of RPV models were made, and then the heat transfer analysis and thermal stress analysis were performed sequentially. Based on the FE results, simple engineering solutions predicting the value of thermal SIF under cool-down and heat-up conditions are suggested.

스마트시티 에너지 감시를 위한 CIM(Common Information Model) 프로파일 설계 (Design of CIM(Common Information Model) Profile for Smart City Energy Monitoring)

  • 김영일;채창훈;김예리;이지훈
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.127-135
    • /
    • 2022
  • With the advent of high technologies such as the 4th Industrial Revolution and artificial intelligence and big data, efforts are being made to solve urban problems and improve the quality of life by applying new technologies in the smart city field. In addition, as carbon neutrality has emerged as an important issue due to global warming, smart city energy platform technologies such as urban energy management, efficiency improvement, and carbon reduction are in the spotlight. In order to effectively manage urban energy, energy resource information such as electricity, water, gas, hot water, heating, etc. must be collected from the management system of various energy utilities and managed on the central platform. The centrally integrated data is delivered to external city management systems that require city energy information through an energy platform. This study developed a CIM profile for smart city energy monitoring required to provide energy data to external systems. Electric data model were designed using the CIM class of IEC 61970, and water, gas, and heat data model were designed in compliance with the UML-based design ideas of IEC 61970.

Effect of reaction temperature and time on the formation of calcite precipitation of recycled concrete aggregate (RCA) for drainage applications

  • Boo Hyun Nam;Jinwoo An;Toni Curate
    • Geomechanics and Engineering
    • /
    • 제33권1호
    • /
    • pp.65-75
    • /
    • 2023
  • Recycled concrete aggregate (RCA) is widely used as a construction material in road construction, concrete structures, embankments, etc. However, it has been reported that calcite (CaCO3) precipitation from RCA can be a cause of clogging when used in drainage applications. An accelerated calcite precipitation (ACP) procedure has been devised to evaluate the long-term geochemical performance of RCA in subsurface drainage systems. While the ACP procedure was useful for the French Drain application, there remained opportunities for improvement. In this study, key factors that control the formation of calcite precipitation were quantitatively evaluated, and the results were used to improve the current prototype ACP method. A laboratory parametric study was carried out by investigating the effects of reaction temperature and time on the formation of calcite precipitation of RCA, with determining an optimum reaction temperature and time which maximizes calcite precipitation. The improved ACP procedure was then applied to RCA samples that were graded for Type I Underdrain application, to compare the calcite precipitation. Two key findings are (1) that calcite precipitation can be maximized with the optimum heating temperature (75℃) and time (17 hours), and (2) the potential for calcite precipitation from RCA is not as significant as for limestone. With the improved ACP procedure, the total amount of calcite precipitation from RCAs within the life cycle of a drain system can be determined when RCAs from different sources are used as pipe backfill materials in a drain system.

Validation of a New Design of Tellurium Dioxide-Irradiated Target

  • Fllaoui, Aziz;Ghamad, Younes;Zoubir, Brahim;Ayaz, Zinel Abidine;Morabiti, Aissam El;Amayoud, Hafid;Chakir, El Mahjoub
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1273-1279
    • /
    • 2016
  • Production of iodine-131 by neutron activation of tellurium in tellurium dioxide ($TeO_2$) material requires a target that meets the safety requirements. In a radiopharmaceutical production unit, a new lid for a can was designed, which permits tight sealing of the target by using tungsten inert gaswelding. The leakage rate of all prepared targets was assessed using a helium mass spectrometer. The accepted leakage rate is ${\leq}10^{-4}mbr.L/s$, according to the approved safety report related to iodine-131 production in the TRIGA Mark II research reactor (TRIGA: Training, Research, Isotopes, General Atomics). To confirm the resistance of the new design to the irradiation conditions in the TRIGA Mark II research reactor's central thimble, a study of heat effect on the sealed targets for 7 hours in an oven was conducted and the leakage rates were evaluated. The results show that the tightness of the targets is ensured up to $600^{\circ}C$ with the appearance of deformations on lids beyond $450^{\circ}C$. The study of heat transfer through the target was conducted by adopting a one-dimensional approximation, under consideration of the three transfer modes-convection, conduction, and radiation. The quantities of heat generated by gamma and neutron heating were calculated by a validated computational model for the neutronic simulation of the TRIGA Mark II research reactor using the Monte Carlo N-Particle transport code. Using the heat transfer equations according to the three modes of heat transfer, the thermal study of I-131 production by irradiation of the target in the central thimble showed that the temperatures of materials do not exceed the corresponding melting points. To validate this new design, several targets have been irradiated in the central thimble according to a preplanned irradiation program, going from4 hours of irradiation at a power level of 0.5MWup to 35 hours (7 h/d for 5 days a week) at 1.5MW. The results showthat the irradiated targets are tight because no iodine-131 was released in the atmosphere of the reactor building and in the reactor cooling water of the primary circuit.

업무용 건물의 이중외피 성능평가를 위한 해석기법의 고찰 - 이중외피 설계안의 에너지 저감 성능 및 환기성능을 중심으로 - (A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building)

  • 정환교;정광섭;이용준;신승철;김영일
    • 에너지공학
    • /
    • 제21권2호
    • /
    • pp.168-178
    • /
    • 2012
  • 본 연구는 업무용 건물에 적용되는 이중외피의 성능을 설계단계에서 평가할 수 있는 정량적인 평가방법을 정립하기 위한 기초적인 평가 수행을 목적으로 하였다. 이를 위하여 평가대상 건물을 선정하여 이중외피 적용을 위한 설계안에 대하여 이중외피 적용 전후의 연간 냉난방 부하를 동적 열부하 해석 프로그램을 이용하여 수행하였으며, 보다 현실적인 평가 결과의 도출을 위하여 CFD를 활용한 풍압계수 도출 및 이를 적용한 환기량 해석을 병행하였고, 이중외피의 환기구 및 중공층 내부의 차양 제어를 위한 모드 설정 및 제어를 통하여 이중외피의 적용 및 제어에 따른 효과를 보다 현실적으로 수행할 수 있는 기법을 제안하였다. 이를 통하여 대상 건물에 대한 이중외피 적용에 따른 연간 냉난방부하를 해석하여 적용 효과를 정량적으로 도출할 수 있는 가능성을 확인하였으며, 이중외피의 형태에 따른 중공층 환경 변화를 확인하였다.

티타늄琺瑯후릿트에 關한 硏究 (Studieson Titanium Enamel Frit)

  • 이종근;한기성
    • 대한화학회지
    • /
    • 제4권1호
    • /
    • pp.18-26
    • /
    • 1957
  • There are two problems to be solved by our efforts in the enamel frit. One is how we can cover the enamel frit thin with complete milk white as possible, and the other is how it can be, made resistant for chemicals than before one. The frit which can solved the two problems just mentioned above is titanium enamel frit. This frit has been developed in America after War Ⅱ, and now the research for concerning antimony frit into titanium frit is under development entirely. In order to develope the enamel industry in Korea, it is urgent problem to convert antimony frit into titanium frit. By the way the titanium frit is emulsified titanium oxide crystal which made through reheating the supersaturated solution of titanium oxide in the basis of glass. Unfortunately, there are many obscure points in active fact or which influence on its composition and characteristics yet. However, this task was tried for the first in Korea. As first step, the test was carried on the reference books, and we can be possible convert antimony frit into titanium frit as a result of this experiment. As a conclusion, for the purpose of developing the enamel industry in Korea, we studied that the research for converting antimony enamel frit which has been used popularly into titanium enamel frit which is more economic and resistant for chemicals. As a result of experiments, the following points concerning with titanium frit have become clearly. 1. It is better when the composition of titanium enamel frit has as following table.Man Duck San Silica 24 An Yang Feldspar 20 Borax 28 Sodium Nitrate 4 Cryolite 7 Calcium Carbonate 3.6∼1 Titanium Oxide 10 Calcium phosphate 0 ∼3.2 Calcium Fluoride 0∼1.8 Antimony Oxide 0∼0.5 2. The amount of $TiO_2$, to be added is $10%\;to\;12{%,\;CaF_2\;is\;under\;1.8%,\;P_2O_5\;is\;under\;1.6%,\;Sb_2O_3\;is\;under\;0.5%$. 3. In the titanium frit, the limit of iron oxide amount to be included is under 0. 5%. 4. Comparing the titanium enamel frit with antimony enamel frit not only the titanium frit can be savely 20.6% in the price of raw materials, but one time of glazing and heating process is omitted in each case, and it is known the titanium frit is more resistant for chemicals than antimony frit.

  • PDF

유리섬유 및 알루미늄 금속 혼합물 유리조성 개발 (Development on Glass Formulation for Aluminum Metal and Glass Fiber)

  • 조현제;김천우
    • 방사성폐기물학회지
    • /
    • 제10권4호
    • /
    • pp.247-254
    • /
    • 2012
  • 원전에서 발생되는 방사성폐기물에 대한 고화처리 방법 중 하나인 유리화기술이 일부 가연성폐기물에 대해 적용되고 있다. 국내외적으로 중저준위 방사성폐기물의 효과적인 감용과 안정적인 처분을 위해 다양한 폐기물에 대한 유리화기술 적용방안이 확대 연구되고 있으며, 최근에는 가연성폐기물 뿐만 아니라 알루미늄 금속과 같은 비가연성폐기물에도 유리화 연구가 활발하게 진행되고 있다. 공기조화계통 (HVAC)에는 주로 필터가 이용되고 있으며, 사용 후 필터는 여과재 (유리섬유 및 알루미늄)를 이용하여 배기체를 흡착하기 때문에 방사성폐기물로 처리가 되어야 한다. 본 연구는 필터에 대한 처리기술 연구를 위해 유도가열식 저온용융로 (Cold Crucible Induction Melter: CCIM)를 이용한 유리화 타당성 연구를 수행하였다. 사용후 필터에 대한 유리화 (Vitrification)는 먼저 유리섬유 및 알루미늄 함량을 고려한 최적의 유리조성을 개발 하였으며, 개발된 유리 조성을 이용하여 최적의 폐기물 저감을 위한 용융변수와 최종 생성된 유리고화체의 특성을 분석하였다. 사용후 필터 유리화용 조성유리는 주로 $SiO_2$$B_2O_3$로 구성되어 있다. 전기로를 이용한 용융물 특성시험에서는 폐기물 투입률 및 최종 생성물인 유리고화체의 특성이 검토되었다. 본 연구에서는 알루미늄 금속과 유리섬유로 구성된 필터에 대한 유리조성 개발과 이를 통해 생성된 유리고화체의 물리화학적 특성을 검토하고 유리화 타당성을 확인하였다.

신포광산(新浦鑛山) 형석(螢石)의 유체포유물(流體包有物에)에 관(關)한 연구(硏究) (Study on Fluid Inclusions in Fluorite from the Sinpo Mine)

  • 이춘우
    • 자원환경지질
    • /
    • 제2권4호
    • /
    • pp.1-21
    • /
    • 1969
  • The Sin po fluorite deposit is of a fissure vein type which strikes $N75^{\circ}E$, dips $80^{\circ}SE$, and is embedded in the pre-Cambrian crystalline schist. The vein is 1 meter in average in thickness, about 800 meters in length and nearly 400 meters in depth. Narrow veins of crustified fluorites and agatic quartz are discontinuously embedded in the quartz gangue. Two-phase fluid inclusions, which are available for the homogenization method by using the Heating Stage Microscope 350, are found in the fluorite crystals. Most of the fluid inclusions are primary in origin and mainly composed of liquid phase associated with minor gas phase. They are tetrahedral, rounded-tubular, wedge shaped, rectangulartrapezoid, and irregular in shape. The maximum diameter of inclusions is 0.5mm and the minimum, 0.03mm, ranging from 0.2mm to 0.08mm in an average. The homogenization temperatures obtained from the test are $135-147^{\circ}C$, $125-138^{\circ}C$, $121-137^{\circ}C$, $116-133^{\circ}C$ and $106-128^{\circ}C$ in greenish, bluish, violet, light grayish blue, colorless and pinkish fluorites respectively. The range of formation temperatures of fluorites is $106-147^{\circ}C$. Therefore, the fluorite deposit of Sinpo Mine is considered to be of low temperature hydrothermal origin. The isothermal lines were drawn on the longitudinal section of the vein from the data of homogenization test. According to the results, the central and lower parts of the ore shoot in the west ore body show the higher temperatures of $130-138^{\circ}C$ and the peripheral and upper parts of it show the lower temperatures of $108-128^{\circ}C$. It seems that the isothermal trend roughly coinside with the pitch of the ore shoot.

  • PDF