• Title/Summary/Keyword: central electrode

Search Result 106, Processing Time 0.032 seconds

Temperature Dependence Characteristics of Double Cylindrical Type Ozonizer (2중 원통형 오존발생기의 온도의존특성)

  • Chun, Byung-Joon;Lee, Sang-Keun;Song, Hyun-Jik;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.953-955
    • /
    • 1998
  • In this paper, a double cylindrical type ozonizer has been designed and manufactured to improve ozone yield by cooling external electrode. The ozonizer equipped with three electrodes( central, internal and external electrodes ) and two gaps. Discharge and ozone characteristics are described in this paper by varying flux( Q ) of oxygen supplied gas, temperature of cooling gas and supplied voltage.

  • PDF

$NO_x$ Measurement of Exhaust Gas plasma by Laser Induced Fluorescence Spectroscopy (배기가스 플라즈마에서의 레이저유기형광법(LIF)에 의한 $NO_x$ 계측)

  • 전용우;하장호;박원주;이광식;최상태;윤영대
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.95-98
    • /
    • 1999
  • This paper describes preliminary discussions on spatial distribution of NO density, which is mostly contained in simulated NOX exhaust, between a wire-cylinder geometry discharge gaps by using Laser Induced Fluorescence(LIF) Spectroscopy. Spatial distribution of NO density will be measured with varying NO concentrations from 166 to 644[ppm] and diameters of central electrode from 6 to 10mm. Pulsed Nd:YAG laser, Optical Parametric Oscillator(OPO), and Frequency Doubler are used to excite NO molecules to their excited state.

  • PDF

Neural Recordings Obtained from Peripheral Nerves Using Semiconductor Microelectrode (반도체 미세전극을 이용한 말초 신경에서의 신경 신호 기록)

  • Hwang, E.J.;Kim, S.J.;Cho, H.W.;Oh, W.T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.31-34
    • /
    • 1997
  • A semiconductor microelectrode array has been successfully used in obtaining single unit recordings from medial giant nerve of clay fish, rat saphenous nerve and abdominal ganglia of aplysia. The recording device fabricated using silicon microfabrication techniques is a depth-probe type and, previously, has been mostly used to record from central nerve system of vertebrates. From invertebrates, and also from peripheral nerves of vertebrates, however, the quality of the recorded signal depends heavily on the recording conditions, such as the proximity of the electrode site to the nerve cells and the size of the neuron. We have modeled the signal to noise ratio as unctions of these parameters and compared the experimental data with the calculated values thus obtained.

  • PDF

NOx Measurement of Diesel Exhaust Gas by Laser Induced Fluorescence (디젤배기가스의 레이저유기형광법에 의한 NOx 계측)

  • Jun, Yong-Woo;Choe, Joon-Yeong;Ha, Chang-Ho;Park, Won-Zoo;Lee, Kwang-Sik;Choi, Sang-Tae;Youn, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2256-2258
    • /
    • 1999
  • This paper describes preliminary discussions on spatial distribution of NO density, which is mostly contained in simulated NOx exhaust, between a wire-cylinder geometry discharge gaps by using Laser Induced Fluorescence(LIF) Spectroscopy, Spatial distribution of NO density will be measured with varying NO concentrations from 166 to 644 [ppm] and diameters of central electrode from 6 to 10mm. Pulsed Nd:YAG laser. Optical Parametric Oscillator(OPO), and Frequency Doubler are used to excite NO molecules to their excited state.

  • PDF

The Characteristics of a Superposed Discharge Type Ozonizer with variation of Mesh (Mesh 형 전극의 조밀도 변화에 따른 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig;Lee, Dong-Heon;Kim, Tae-Ju;Lee, Kwang-Sik;Chun, Byung-Jun;Ha, Jang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1834-1836
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer(SDO) has been designed and manufactured. SDO is equipped with three electrodes(central, internal and external electrodes), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. At this time, Internal electrode consists of a mesh type. This paper describes the discharge and ozone generation characteristics of SDO with variation of mesh and discharge wattage.

  • PDF

Synthesis of the New 1,2-Dithiolene Metal Complexes[M$(BDDT)_2^-$] (M=Ni, Cu) and Their Electrode Structures

  • 전기원;Robert D. Bereman
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.7
    • /
    • pp.612-616
    • /
    • 1996
  • The new 1,2-dithiolene, 1,4-butanediyldithioethylene-1,2-dithiolate (BDDT2-), has been isolated. In addition, new monoanionic bis-complexes with nickel and copper have been prepared and characterized. In order to investigate the detailed electronic structure of the metal complexes of the new ligand, BDDT2-, in terms of the oxidation state of the central metal ions, we have carried out molecular orbital (MO) calculations of Ni(BDDT)2-and Cu(BDDT)2- utilizing an Extended Huckel method. Cyclic voltammetry data for both complexes were obtained with a potentiostat. We have also compared these results to the previously synthesized Ni(PDDT)2-, Ni(DDDT)2-,Cu(PDDT)2-, and Cu(DDDT)2-.

HASEL Actuator Study for Tactile Feedback Device (촉감 피드백을 위한 유압증폭자기치유형 정전식 액추에이터 연구 개발)

  • Song, Kahye
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2021
  • Attempts are being made to provide various tactile feedbacks to user. In particular, a variety of soft actuators are being inserted into the tactile feedback device to give a more flexible, soft and strong stimulation. In this study, a basic study was performed to utilize a hydraulically amplified self-healing electrostatic (HASEL) actuator as a tactile feedback actuator. The HASEL actuator showed great displacement and force with a simple circuit configuration. In particular, by making the actuator in a circular shape, the angle was reduced and the electrode was arranged in a ring shape to maximize the displacement of the central part. As a result, the HASEL actuator showed a displacement difference according to the input waveform. In addition, in order to use it safely as an actuator for tactile feedback, we covered the surface with silicone and confirmed that the actuator works well. Using these actuators, it will be possible to manufacture a lightweight, portable tactile feedback device.

Effect of $Ar^+$ RF Plasma Treatment Conditions on Interfacial Adhesion Energy Between Cu and ALD $Al_2O_3$ Thin Films for Embedded PCB Applications ($Ar^+$ RF 플라즈마 처리조건이 임베디드 PCB내 전극 Cu박막과 ALD $Al_2O_3$ 박막 사이의 계면파괴에너지에 미치는 영향)

  • Park, Sung-Cheol;Lee, Jang-Hee;Lee, Jung-Won;Lee, In-Hyung;Lee, Seung-Eun;Song, Byoung-Ikg;Chung, Yul-Kyo;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • Interfacial fracture energy(${\Gamma}$) between $Al_2O_3$ thin film deposited by Atomic Layer Deposition(ALD) and sputter deposited Cu electrode for embedded PCB applications is measured from a $90^{\circ}$ peel test. While the interfacial fracture energy of $Cu/Al_2O_3$ is very poor, Cr adhesion layer increases the interfacial fracture energy to $39.8{\pm}3.2g/mm\;for\;Ar^+$ RF plasma power density of $0.123W/cm^2$, which seems to come from the enhancement of the mechanical interlocking and Cr-O chemical bonding effects.

  • PDF

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

Pore Gradient Nickel-Copper Nanostructured Foam Electrode (기공 경사화된 나노 구조의 니켈-구리 거품 전극)

  • Choi, Woo-Sung;Shin, Heon-Cheol
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.4
    • /
    • pp.270-276
    • /
    • 2010
  • Nickel-copper foam electrodes with pore gradient micro framework and nano-ramified wall have been prepared by using an electrochemical deposition process. Growth habit of nickel-copper co-deposits was quite different from that of pure nickel deposit. In particular, the ramified structure of the individual particles was getting clear with chloride ion content in the electrolyte. The ratio of nickel to copper in the deposits decreased with the distance away from the substrate and the more chloride ions in the electrolyte led to the more nickel content throughout the deposits. Compositional analysis for the cross section of a ramified branch, together with tactical selective copper etching, proved that the copper content increased with approaching central region of the cross section. Such a composition gradient actually disappeared after heat treatment. It is anticipated that the pore gradient nickel-copper nanostructured foams presented in this work might be a promising option for the high-performance electrode in functional electrochemical devices.