• Title/Summary/Keyword: central electrode

Search Result 106, Processing Time 0.026 seconds

Response Mechanism of 5, 10, 15, 20-tetraphenyl(porphyrinato) Manganase(III) chloride-Based Ion-Selective Membranes (망간포르피린을 함유한 고분자형 이온선택성 막전극의 감응 메카니즘)

  • Hong, Young Ki;Kang, You Ra;Shin, Dae Ho;Shin, Doo Soon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.270-278
    • /
    • 1996
  • Response mechanism for the chloride-selective membrane doped with 5, 10, 15, 20-tetraphenyl(porphyrinato)manganase(III) chloride(Mn(TPP)Cl) in PVC/DOS matrix is proposed by examining the visible spectra of the corresponding optode membrane. The visible spectra of Mn(TPP)Cl-doped membrane placed in aqueous solution show that the chloride ligand is easily replaced with water molecule. When other halogen ions, such as $F^-$, $Br^-$ and $I^-$, are added to the sample solution, they replace the water ligand, exhibiting distinctive change in the Soret band of Mn(TPP). On the other hand, bulky anions, such as SCN and salicylate, do not form a bond with the central metal. These results suggests that the potentiometric response of Mn(TPP)-based membrane results either from the ligand exchange (water with halides) at the central metal or from the counter ion exchange (chlorides with bulky lipophilic anions) around the positively charged porphyrin molecule in membrane phase. It was also noted that both hydration enthalpies of anions and their binding constants to Mn(TPP) play critical role in determining the potentiometric selectivity pattern of the membrane.

  • PDF

N100 Amplitude Slopes in Major Depressive Disorder, Bipolar Disorder, Schizophrenia and Normal Controls (주요 우울 장애, 정신분열병, 양극성 장애 및 정상 대조군에서의 N100 진폭경사)

  • Yang, Eunkyoung;Lee, Seung-Hwan;Oh, Sunghee;Kim, Sangrae
    • Korean Journal of Biological Psychiatry
    • /
    • v.16 no.3
    • /
    • pp.181-189
    • /
    • 2009
  • Objectives : N100 amplitude slope(the intensity dependence of the cortical auditory evoked potentials) is widely considered as an indirect indicator of central serotonergic neurotransmission. However, there are only a few studies about N100 amplitude slopes of major psychiatric disorders. In this study, we examined N100 amplitude slope differences among major depressive disorder(MDD), bipolar disorder(BD), schizophrenia (SCZ) and normal controls(NC). Methods : We measured the N100 amplitude slopes of 35 patients with MDD, 33 patients with BD, 27 patients with SCZ and 35 NC subjects. Amplitude differences from N1 to P2 at the five different sound intensities(55, 65, 75, 85 and 95dB) were examined at Cz electrode. The N100 amplitude slope was calculated as the linear regression of five N1/P2 peak-to-peak amplitudes across stimulus intensities. Results : BD patients showed significantly reduced N100 amplitude slope compared with NC(0.54${\pm}$0.70 vs. 0.96${\pm}$0.72, p=0.035). N100 amplitude slope of SCZ patients was significantly reduced compared with NC(0.50${\pm}$0.47 vs. 0.96${\pm}$0.72, p=0.027). N100 amplitude slope of BD patients was significantly lower than that of MDD patients(0.54${\pm}$0.70 vs. 0.94${\pm}$0.60, p=0.046). SCZ patients also showed significant reduction of N100 amplitude slope compared with MDD patients(0.50${\pm}$0.47 vs. 0.94${\pm}$0.60, p=0.036). There was no significant difference of N100 amplitude slope between MDD patients and NC(0.94${\pm}$0.60 vs. 0.96${\pm}$0.72, p=1.000). Conclusion : Interestingly, the N100 amplitude slopes of BD and SCZ were reduced compared to NC and MDD patients. Our results suggest the predictive use of N100 amplitude slope in making differential diagnoses of major psychiatric disorders. Clinical implications of N100 amplitude slope in major psychiatric disorders were discussed.

  • PDF

A Fabrication and Properties of Ionization Chamber Using Madium Exposure Rate (중준위 조사선량율 측정용 전리함의 설계 및 특성)

  • Woo, Hong;Kim, Sung-Hwan;Kang, Hee-Dong
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.29-40
    • /
    • 1996
  • We had designed and made the cylindrical ionization chamber which operated above 5 mR/h. Using commercial electrometer, we investigated the characterictic of charge collection in the ion chamber. The active volume was 190.4㎤ and overall length and diameter in the chamber was 15.5cm, 5.22cm, respectively. The chamber had three electrodes(inner, central, wall electrode). And background current was 8.39${\times}$10$\^$-14/${\pm}$1.5${\times}$10$\^$-15/A to arrange the electrodes which were coaxial in chamber axis. The collection efficiency of chamber for Cs$\^$137/ was 99.7% when the opreating voltage was applied 400V. Comparing with the commertial dosimetry system, the exposure calibration constant was 4.531${\times}$19$\^$7/R/C. By normalizing to CS$\_$137/ the relative energy response of the chamber was 1.30 for Am$\_$24/, 1.05 for C0$\_$60/, respectively. When the irrarition tranversed to the chamber axis, the isotropic effect of the chamber was not considerable.

  • PDF

Measurement of EUV Emission and its Plasma Parameters Generated from the Coaxial Plasma Focus of Mather and Hypocycloidal Pinched Electrodes

  • Lee, Sung-Hee;Lee, Kyung-Ae;Hong, Young-June;Uhm, Han-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.332-332
    • /
    • 2011
  • The extreme ultraviolet (EUV) radiation, whose wavelength is from 120 nm down to 10 nm, and the energy from 10 eV up to 124 eV, is widely utilized such as in photoelectron spectroscopy, solar imaging, especially in lithography and soft x-ray microscopy. In this study, we have investigated the plasma diagnostics as well as the debris characteristics between the two types of dense plasma focusing devices with coaxial electrodes of Mather and hypocycloidal pinch (HCP), respectively. The EUV emission intensity, electron temperature and plasma density have been investigated in these cylindrical focused plasma along with the debris characteristics. An input voltage of 5 kV has been applied to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ar gas at pressure ranged from 1 mTorr and 180 mTorr. The inner surface of the cathode was covered by polyacetal insulator. The central anode electrode has been made of tin. The wavelength of the EUV emission has been measured to be in the range of 6~16 nm by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission has also been measured by the spectrometer with the wavelength range of 200~1,100 nm. The electron temperature and plasma density have been measured by the Boltzmann plot and Stark broadening methods, respectively, under the assumption of local thermodynamic equilibrium (LTE).

  • PDF

TEVC Studies of potent Antagonists of Human $P2X_3$ Receptor

  • Moon, Hyun-Duk;Lee, Jung-Sun;Park, Chul-Seung;Kim, Yong-Chul
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.55-55
    • /
    • 2003
  • P2X$_3$ receptor, a member of P2 purine receptors, is a ligand-gated ion channel activated by extracellular ATP as an endogenous ligand, and highly localized in peripheral and central sensory neurons. The activation of P2X3 receptor by ATP as the pronociceptive effect has been known to initiate the pain signaling involved in chronic inflammatory nociception and neuropathic pain by nerve injury, implicating the possibility of new drug development to control pains. In this study, we have developed a two electrode voltage clamp (TEVC) assay system to evaluate the inhibitory activity of several newly synthesized PPADS and a novel non-ionic antagonist against ATP activation of human P2X3 receptor. PPADS derivatives include several pyridoxine and pyridoxic acid analogs to study the effects of phosphate and aldehyde functional groups in PPADS. All new PPADS analogs were less potent than PPADS at human P2X$_3$ receptors, however, LDD130, a non-ionic analog showed potent antagonistic property with $IC_{50}$/ of 8.34 pM. In order to uncover the structure activity relationships of LDD130, and design new structural analogs, we synthesized and investigated a few structural variants of LDD130, and the results will be discussed in this presentation.

  • PDF

Development of Wireless ECG Clothing for Dogs with Improved Signal Detection (신호 감지성이 향상된 반려견용 무선 심전도 측정 의복 개발)

  • Kim, Soyoung;Lee, Okkyung;Kwon, Eunsun;Lee, Yejin;Min, Seungnam;Lee, Heeran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.760-771
    • /
    • 2022
  • This study sought to develop clothing for a companion animal that can provide stable ECG measurements. A pattern for the smart clothing of a companion dog was manufactured using the replica method to select a location and method that best suited the stable measurement of ECG and improved the clothing's fitness. The smart clothing was developed as the following three types: strap type, top type, and combined top and vest type with a detachable wireless ECG monitor. The detection abilities of these were observed using the PQRST rate taken after ECG measurements while the three companion dogs were tested while resting and moving. The results revealed that apart from using an electrode, applying a gel pad is the most effective way to achieve stable ECG measurements, and the central chest region is more reliable than the left armpit for providing steady readings. The combined top and vest type showed the highest average ECG PQRST detection number, meaning that the ECG signal measurement was steady. These results may contribute to the measurement of ECG in smartwear for U-Healthcare to measure other biometric data of a companion dog.

Review on CNT-based Electrode Materials for Electrochemical Sensing of Ascorbic Acid

  • P Mary Rajaitha;Runia Jana;Sugato Hajra;Swati Panda;Hoe Joon Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.131-139
    • /
    • 2023
  • Ascorbic acid plays a crucial role in the regulation of neurotransmitters and enzymes in the central nervous system. Maintaining an optimal level of ascorbic acid, which is between 0.6-2 mg/dL, is vital for preventing oxidative stress and associated health conditions, such as cancer, diabetes, and liver disease. Therefore, the detection of ascorbic acid is of the utmost importance. Electrochemical sensing has gained significant attention among the various detection methods, owing to its simplicity, speed, affordability, high selectivity, and real-time analysis capabilities. However, conventional electrodes have poor signal response, which has led to the development of modified electrodes with better signal response and selectivity. Carbon nanotubes (CNTs) and their composites have emerged as promising materials for the electrochemical detection of ascorbic acid. CNTs possess unique mechanical, electrical, and chemical properties that depend on their structure, and their large surface area and excellent electron transport properties make them ideal candidates for electrochemical sensing. Recently, various CNT composites with different materials and nanoparticles have been studied to enhance the electrochemical detection of ascorbic acid. Therefore, this review aims to highlight the significance of CNTs and their composites for improving the sensitivity and selectivity of ascorbic acid detection. Specifically, it focuses on the use of CNTs and their composites in electrochemical sensing to revolutionize the detection of ascorbic acid and contribute to the prevention of oxidative stress-related health conditions. The potential benefits of this technology make it a promising area for future research and development.

Molybdenum-Based Electrocatalysts for Direct Alcohol Fuel Cells: A Critical Review

  • Gaurav Kumar Yogesh;Rungsima Yeetsorn;Waritnan Wanchan;Michael Fowler;Kamlesh Yadav;Pankaj Koinkar
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.67-95
    • /
    • 2024
  • Direct alcohol fuel cells (DAFCs) have gained much attention as promising energy conversion devices due to their ability to utilize alcohol as a fuel source. In this regard, Molybdenum-based electrocatalysts (Mo-ECs) have emerged as a substitution for expensive Pt and Ru-based co-catalyst electrode materials in DAFCs, owing to their unique electrochemical properties useful for alcohol oxidation. The catalytic activity of Mo-ECs displays an increase in alcohol oxidation current density by several folds to 1000-2000 mA mgPt-1, compared to commercial Pt and PtRu catalysts of 10-100 mA mgPt-1. In addition, the methanol oxidation peak and onset potential have been significantly reduced by 100-200 mV and 0.5-0.6 V, respectively. The performance of Mo-ECs in both acidic and alkaline media has shown the potential to significantly reduce the Pt loading. This review aims to provide a comprehensive overview of the bifunctional mechanism involved in the oxidation of alcohols and factors affecting the electrocatalytic oxidation of alcohol, such as synthesis method, structural properties, and catalytic support materials. Furthermore, the challenges and prospects of Mo-ECs for DAFCs anode materials are discussed. This in-depth review serves as valuable insight toward enhancing the performance and efficiency of DAFC by employing Mo-ECs.

MR Imaging-Histopathologic Correlation of Radiofrequency Thermal Ablation Lesion in a Rabbit Liver Model: Observation during Acute and Chronic Stages

  • Jong Deok Lee;Jeong Min Lee;Sang Won Kim;Chong Soo Kim;Woo Sung Mun
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.151-158
    • /
    • 2001
  • Objective: To determine the ability of MR imaging to detect the pathological changes occurring in radiofrequency (RF) thermal lesions and to assess its accuracy in revealing the extent of tissue necrosis. Materials and Methods: Using an RF electrode, thermal lesions were created in the livers of 18 rabbits. The procedure involved three phases. In the acute phase, six animals were killed the day after performing thermal ablation with RF energy, and two on day 3. In the subacute and chronic phases, eight rabbits underwent percutaneous hepatic RF ablation. After performing MR imaging, two animals were sacrificed at 1, 2, 4, and 7 weeks after the procedure, and MRpathologic correlation was performed. Results: In the acute phase, the thermal ablation lesions appeared at gross examination as well-circumscribed, necrotic areas, representing early change in the coagulative necrosis seen at microscopic examination. They were hypointense on T2-weighted images, and hyperintense on T1-weighted images. Gadolinium-enhanced MR imaging showed that a thin hyperemic rim surrounded the central coagulative necrosis. In the subacute phase, ablated lesions also showed extensive coagulative necrosis and marked inflammation at microscopic examination. Beyond two weeks, the lesions showed gradual resorption of the necrotic area, with a peripheral fibrovascular rim. The size of lesions measured by MR imaging correlated well with the findings at gross pathologic examination. Conclusion: MR imaging effectively demonstrates the histopathological tissue change occurring after thermal ablation, and accurately determines the extent of the target area.

  • PDF

Preliminary Report of Gamma Knife Radiosurgery for the Movement Disorders (운동성 장애에 대한 감마나이프 시술의 초기경험)

  • Hong, Joon Ki;Kim, Moo Seong;Lee, Sun Il;Jung, Yong Tae;Kim, Soo Chun;Sim, Jae Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1024-1029
    • /
    • 2000
  • Objectives : With recent improvements in neuroimaging and the development of third and fourth-generation radiosurgical dose-planning soft ware, came a renewed interest in using radiosurgery for the treatment of movement disorders. Radiosurgery involves no opening of the cranium and no incisions, eliminating both the risk of hemorrhage from passing an electrode to the depths of meningitis from operative infection. It is for these reasons stereotactic radiosurgical treatment of movement disorders has value in a small subgroup of patients. The authors report four cases of Parkinson's disease and one case of dystonia that were treated by Gamma knife. Methods : Radiosurgical nucleus ventralis intermedius thalamotomy using the gamma knife unit was performed to make lesion in two Parkinson's disease patients. A radiation dose of 120Gy was delivered to nucleus using a single 4-mm collimator plug pattern following classic anatomical landmarks. Patients were followed for a median of 10.5 months(range 9-12 months). An independent neurological evaluation of tremor, based on the change in the United Parkinson's Disease Rating Scale tremor score(UPDRS), was correlated with a subjective evaluation. Gamma knife ventrolateral(V.O.P) thalamotomy was performed in one case of dystonia. A central dose of 150Gy was delivered and the patient was followed for 18 months. Gamma knife globus pallidus interna pallidotomy was performed in two Parkinson's disease patients. A radiation dose of 130Gy(range 120-140Gy) was delivered. Patients were followed for a median of 13 months(range 9-14 months). Result : Ventrolateral thalamotomy in dystonia produced regained left hand usage in order to be able to use the telephone. Ventralis intermedius thalamotomy produced an excellent improvement of the tremor in one case, mild improvement of the tremor in the other case of Parkinson's disease. A globus pallidus internalis(GPi) pallidotomy produced improvement of rigidity and dyskinesia : one other showed no change. There were no neurological complications. Conclusion : Gamma Knife thalamotomy considered a safe and effective technique for the treatment of tremor in Parkinson's disease. Although the results from Longer follow-up is not available yet, the short-term results seem to be encouraging.

  • PDF