• Title/Summary/Keyword: central difference method

Search Result 359, Processing Time 0.025 seconds

In Vivo Measurement of Extracellular Monoamines and Their Metabolites in the Rat Posterior Hypothalamus Using Microdialysis Technique (미세투석법을 이용하여 흰쥐 후 사상하부에서 세포외액의 모노아민과 대사체들의 생체내 측정)

  • Sung, Ki-Wug;Kim, Seong-Yun;Cho, Young-Jin;Lee, Kweon-Haeng;Lee, Sang-Bok
    • The Korean Journal of Pharmacology
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 1992
  • Catecholamines, serotonin and their metabolites were measured in the posterior hypothalamus of urethane-anesthetized normotensive Wistar Kyoto rats (WKY) and spontaneously hypertensive rats (SHR) using brain microdialysis which is a recently developed experimental method to measure the release of neurotransmitters and their metabolites at the localized brain area in vivo. Microdialysis probe was implanted stereotaxically to the rat posterior hypothalamus and perfused by Ringer's solution. Monoamines and their metabolites were quantified by reverse phase high performance liquid chromatography with electrochemical detection. In vitro recovery test of microdialysis showed that there exist inverse relationship between the perfusion flow rate and the relative recovery of neurochemical compounds. The estimated extracellular concentration of dopamine was about 32 nM, of norepinephrine 50 nM, of epinephrine 50 nM, of serotonin 73 nM, of 3, 4-dihydroxyphenylacetic acid (DOPAC) 281 nM, of homovanillic acid (HVA) 181 nM, and of 5-hydroxyindoleacetic acid (5HIAA) 3767 nM in the hypothalamic perfusate of the normotensive rat. There was no difference in the basal level of monoamines between the SHR and the WKY. In contrast, the level of DOPAC, HVA and 5HIAA in SHR was higher than that in the WKY, This study demonstrated that the microdialysis technique should be an applicable tool for in vivo measurement of central neurochemical substances.

  • PDF

No Association of Hypoxia Inducible Factor-1α Gene Polymorphisms with Breast Cancer in North-West Indians

  • Sharma, Sarika;Kapahi, Ruhi;Sambyal, Vasudha;Guleria, Kamlesh;Manjari, Mridu;Sudan, Meena;Uppal, Manjit Singh;Singh, Neeti Rajan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9973-9978
    • /
    • 2014
  • Background: Hypoxia inducible factor-1 alpha (HIF-$1{\alpha}$) is the key regulator of cellular responses to hypoxia and plays a central role in tumour growth. Presence of Single nucleotide polymorphisms (SNPs) in the critical regulatory domains of HIF-$1{\alpha}$ may result in the overexpression of the protein and subsequent changes in the expression of the downstream target genes. The aim of study was to investigate the association of three SNPs (g.C111A, g.C1772T and g.G1790A) of HIF-$1{\alpha}$ with the risk of breast cancer in North Indian sporadic breast cancer patients. Materials and Methods: A total of 400 subjects, including 200 healthy controls and 200 patients with breast cancer were recruited in this study. Genotypes were determined using polymerase chain reaction - restriction fragment length polymorphism (PCR-RFLP) method. Results: The CC and CA genotype frequency of HIF-$1{\alpha}$ g.C111A polymorphism was 100 vs 99% and 0 vs 1% in breast cancer patients and healthy controls respectively. The frequencies of CC, CT and TT genotype of g.C1772T polymorphism were 76 vs 74.5%, 19 vs 21% and 5 vs 4.5% in breast cancer patients and control individuals respectively. There was no significant difference in genotype and allele frequencies of HIF-$1{\alpha}$ g.C1772T polymorphism between cases and control individuals (p>0.05). For g.G1790A genotypes, all patients and controls had only GG genotype. Conclusions: The three HIF-$1{\alpha}$ polymorphisms (g.C111A, g.C1772T and g.G1790A) are not associated with breast cancer risk in North-West Indian patients.

Extracorporeal Membrane Oxygenation in Pediatric Patients with Respiratory Failure: Early Experience with the Double-Lumen Cannula Over 2 Years

  • Kim, Woojung;Kwon, Hye Won;Min, Jooncheol;Cho, Sungkyu;Kwak, Jae Gun;Kim, Woong Han
    • Journal of Chest Surgery
    • /
    • v.53 no.3
    • /
    • pp.132-139
    • /
    • 2020
  • Background: The double-lumen cannula (DLC) has begun to be used worldwide for venovenous (VV) extracorporeal membrane oxygenation (ECMO). We aimed to examine whether the DLC could be an effective tool in the treatment of pediatric respiratory failure in Korea. Methods: We reviewed the records of patients weighing under 15 kg who underwent ECMO due to respiratory failure between January 2017 and December 2018. Outcomes of ECMO using a DLC and conventional ECMO using central method or 2 peripheral cannulas were compared. Results: Twelve patients were treated with ECMO for respiratory failure. Among them, a DLC was used in 5 patients, the median age of whom was 3.8 months (interquartile range, 0.1-49.7 months). In these patients, the median values of pH, partial pressure of carbon dioxide, and partial pressure of oxygen were 7.09, 74 mm Hg, and 37 mm Hg before ECMO and corrected to 7.31, 44 mm Hg, and 85 mm Hg, respectively, after ECMO cannulation. Median blood flow rate in the patients treated with ECMO using a DLC was slightly higher than that in the conventional ECMO group, but this difference was not statistically significant (86.1 mL/kg/min and 74.3 mL/kg/min, respectively; p=1.00). One patient from the DLC group and 3 patients from the conventional group were weaned off ECMO. Conclusion: VV ECMO using a DLC provided adequate oxygenation, ventilation, and blood flow rate in Korean pediatric patients with respiratory failure. Further prospective and randomized studies are warranted.

EVALUATION OF MICROLEAKAGE WITH RETROGRADE FILLING MATERIALS IN BLOOD CONTAMINATION USING FLUID TRANSPORT MODEL (Fluid transport model을 이용한 치근단 역충전 재료의 혈액오염시 미세누출평가)

  • Ahn, Hyo-Soon;Jang, In-Ho;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Leakage studies have been performed frequently, since a fluid-tight seal provided by various dental fill-ing materials has been considered clinically important. The leakage of the various root-end filling materials has been widely investigated mostly dye penetration method. These dye studies cannot offer any information about the quality of the seal of a test material over a long period of time The purpose of this study was to evaluate the microleakage of root end cavities in blood contamination filed amalgam, intermediate restorative material(IRM), light cured glass ionomer cement(GI) and mineral trioxide aggregate(MTA) by means of a modified fluid transport model. Fifty standard human root sections, each 5mm high and with a central pulp lumen of 3mm in diameter, were and filled with our commonly used or potential root end fill ing materials after they were contaminated with blood. At 24h. 72h, 1, 2, 4, 8, and 12 weeks after filling, leakage along these filling materials was determined under a low pressure of 10KPa(0.1atm) using a fluid transport model. The results were as follows : 1 MTA group showed a tendency of decreasing percent of gross leakage (20m1/day) in process of time, whereas the other materials showed a tendency of increasing in the process time. 2. At the all time interval, GI group leaked significantly less than amalgam group and IRM group (p<0.05). 3. At the 4 weeks, the percentage of gross leakage in MTA group decreased to 0% thereafter, the low per-centage of gross leakage was maintained in MTA group until the end of the experiment, whereas the percentage in IRM group increased to 100% 4. At the 12 weeks, percentage of gross leakage was significantly low in MTA group(0%), comparison with GI group(40%), amalgam group(90%) and IRM group(100%), but there was no significant difference between latter two materials.

Efficient Data Acquisition Technique for Clinical Application of Multileaf Collimator (다엽콜리메이터의 임상적용을 위한 효율적인 정보 취득 기술)

  • Lee, Jae-Seung;Kim, Jung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.182-188
    • /
    • 2008
  • The MLC(multi leaf collimator) in charge of important role in radiation therapy field recently have been exchanging from shielding block into it rapidly, owing to being convenient. However, MLC can be occurred the leakage dose of inter_leaves and the error of algorithm in imput and output from digital signal. We compared the difference of imput method to MLC made by Varian Cop. with the error and effective field induced by MLC shaper and film scanner based on XimaVision value as using MLC layer of various shapes. According to comparing standard value with them to basic MLC layer (test1-5), MLC shaper was $0{\sim}0.29cm$, $0.23{\sim}3.59cm^2$ and film scanner was $0{\sim}0.78cm$, $0.24{\sim}3.89cm^2$. At the MLC layer to be applied in clinic, MLC shaper was $0{\sim}0.54cm$, $0.04{\sim}1.68cm^2$ and film scanner was $0{\sim}0.78cm$, $0.24{\sim}3.89cm^2$. The more distance and field from axis of central line increase, the more bigger the error value increases. There is a few mm error from standard point at the process which imput various information to apply MLC in clinic. and effective field did not have variation of monitor unit and dose owing to being a few cm2 error against real field. But there are some problem to shield critical organs because some part of target volume induced by the movement of organs can be not included, therefore we have to pay attention on the process to imput MLC layer

Ball Velocity Changes Depending on the Different Linear Momentum of Putter Head during the Putting Strokes (퍼팅 스트로크에서 퍼터의 선 운동량 크기에 따른 볼의 이동 속도 변화에 관한 연구)

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.83-88
    • /
    • 2007
  • The purpose of this study was to investigate the ball velocity changes depending on the different linear momentum of putter head. For this study, two different moving conditions(25cm free fall and 35cm free fall) of putter head were set. And two different types of ground conditions were used which are artificial grass green($180cm{\times}600cm{\times}1cm$) and glass green($40cm{\times}130cm{\times}1cm$). Movements of putter head and ball were recorded with 2 HD video cameras(60 Hz, 1/500s shutter speed). Small size control object($18.5cm{\times}18.5cm{\times}78.5cm$) was used in this study. Ball and putter head velocities were calculated by the First Central Difference Method(Hamill & Knutzen, 1995). Linear momentum of ball and putter head were calculated with mass and its velocities. Before impact, the velocity of the putter head of 35cm free fall was about 30% greater than that of the putter head of 25cm free fall. Linear momentum of putter head of 35cm free fall was about 0.355-0.364kg m/s and 25cm free fall was 0.251 kg m/s. After impact, putter head lost its linear momentum about 14-19% and adjusting time of putter head after impact would be 0.1 second. After 0.1 second, putter moved the route same as before impact. Maximum ball velocities were appeared 0.08s-0.10s after impact no matter what the ground conditions are. Ball velocities struck by 35cm free fall were 30 % faster than 25cm free fall. Linear momentum of ball struck by putter head was greater than that of expected amount because the moving ball has translational energy and rotational energy. Future study must treat three things. One is ball must struck by the different putters with different materials. Another is two-piece ball and three-piece ball should be used for the same condition studies. The other is height of center of rotation of club should be changed. In this study, the height of center of rotation of club head is 71cm from the ground. But recently many golfers used the long putter. Therefore next study should apply the different height of center of rotation of club head.

Fatigue Durability Evaluation of Refraction Expansion Joints (굴절형 신축이음장치의 피로내구성 평가)

  • Na, Jun-Su;Lee, Ta;Han, Eui-Seok;Sung, Won-Kyu;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.10-15
    • /
    • 2017
  • The refraction expansion joints have been newly developed by complementing the problems of shock, noise, replaceability, displacement in the direction perpendicular to bridge, vertical difference, which are problems of existing expansion joints. The Refraction expansion joints are characterized by continuous surfaces with small impact and low noise. The behavior of the Refraction expansion joints performs the bridge expansion behavior by rotation of the link. In the rotational behavior of the link, the bolt is the central axis of the behavior. Therefore, it can be said that the durability of the bolt is very important. However, the theoretical and experimental verification of the bolt durability of the Refraction expansion joint is lacking. In this paper, to verify the fatigue durability of the bolt, test specimens with a 300 mm Refraction expansion joint were fabricated. A strain gauge dedicated to the bolt was installed inside the manufactured test specimen bolt. The test method was applied in accordance with KS F 4425. The fatigue durability of the bolts assembled inside the diaphragm expansion joint was confirmed by the repeated fatigue test of 2,000,000 cycles.

Optimization of microwave-assisted extraction process of Hordeum vulgare L. by response surface methodology (반응표면분석법을 이용한 새싹보리 마이크로웨이브 추출공정의 최적화)

  • Lee, Jae-Jun;Park, Dae-Hee;Lee, Won-Young
    • Food Science and Preservation
    • /
    • v.24 no.7
    • /
    • pp.949-956
    • /
    • 2017
  • This study attempted to find optimum extract range of active ingredient for barley sprouts (Hordeum vulgare L.). Extracts from Hordeum vulgare L. were made by microwave extraction method and total polyphenol content (TPC), total flavonoid content (TFC), DPPH radical scavenging activity (DPPH) were measured with extract of Hordeum vulgare L.. Response surface methodology (RSM) was applied to a extraction process, and central composite design (CCD) was also used for this process to examine the optimum condition. Independent variables ($X_n$) are concentration of ethanol ($X_1$: 0, 25, 50, 75, 100%), microwave power ($X_2$: 60, 120, 180, 240, 300 W), extraction time ($X_3$: 4, 8, 12, 16, 20 min). Dependent variables ($Y_n$) are TPC ($Y_1$), TFC ($Y_2$), DPPH radical scavenging ($Y_3$). It is formed by sixteen conditions to extract. The $R^2$ value of dependent variables is ranged from 0.90 to 0.97 (p<0.05). Experiments values within the optimal range (40% of ethanol concentration, 120 W of microwave power, 18 min of extraction time) were 3.74 mg GAE/g (TPC), 3.00 mg RE/g (TFC), 35.43% (DPPH), respectively. Under the optimized conditions, predicted value showed no significant difference comparing with the experimental values.

Changes of Various Balls Velocity under the Different Surface Conditions after Impact (충돌 후 지면 조건에 따른 다양한 볼의 속도변화에 관한 연구)

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.91-97
    • /
    • 2007
  • The purpose of this study was to investigate the changes of various balls velocity under the different surface conditions after impact. For this study, four different balls were used which are golf ball, tang-tang ball, table tennis ball, and iron ball. And two different types of ground conditions were used which are artificial grass green and glass green. Movements of putter head and ball were recorded with 2 HD video cameras(60 Hz, 1/500s shutter speed). Small size control object($18.5cm{\times}18.5cm{\times}78.5cm$) was used in this study. To transfer the same amount of kinetic energy to the ball, pendulum putting machine was used. Analyzing the process of impact and the ball movement, a putter was digitized the whole movement but the ball was digizited within the 50cm movement. Velocities were calculated by the first central difference method(Hamill & Knutzen, 1995). Putter head velocities were about 112.2cm/s-116.2cm/s at impact. Maximum ball velocities were appeared 0.08s-0.10s after impact no matter what the ground conditions are. Table tennis ball recorded higher ball velocities than the other ball velocities and iron ball recorded the lowest ball velocity in this group. But Table tennis ball was influenced with the frictional force and immediately was decreased at the artificial grass green condition. If an object is received the kinetic energy under the static condition(v=0cm/s), the object recorded the maximum velocity shortly after the impact and then decreased the velocity because of the frictional force. The ball distance from the start position to the peak velocity position is about 6cm-10cm under the 112.2cm/s-116.2cm/s putting velocity with putter. 0.25 seconds later after impact balls were placed 40cm distance from the original position except iron ball. In this study, ball moving distances were too short therefore it was not possible to investigate the reactions after the translational force is disappeared. Rotational force would play a major role at the end of the ball movement. Future study must accept two things. One is long distance movement of ball and the other is balanced ground. Three-piece ball is a good item to investigate the golf ball movement on the different surface conditions.

Diagnostic Efficacy and Complications by Transthoracic Fine Needle Aspiration Biopsy of Localized Lung Lesions (국소성 폐결절에 대한 경피적 세침 흡인술의 진단적 유용성 및 합병증)

  • Seong, Nak-Cheon;Kim, Ki-Joong;Yoon, Ki-Heon;Yoo, Jee-Hong;Kang, Hong-Mo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.339-347
    • /
    • 1996
  • Background : Transthoracic fine needle aspiration and biopsy(TNAB) has become a frequently used technique in the investigation of the intrathoracic lesions because of its safety, reliability, and accuracy. Method : Data on 125 patients who underwent TNAB from 1990 through 1994 were studied to determine the diagnostic sensitivity, accuracy and complications of this procedure as related to lesion type and location. Results : 1. The over-all diagnostic sensitivity of TNAB was 61.6%(77 of 125 patients). 2. The diagnostic yields were as high as 89.9% for malignant lesions, but a specific diagnosis of benign lesions were obtained only in 30% of benign lung lesions. 3. The correlation between results of TNAB cytology and of final histology was as high as 88.2%. 4. Lung lesions that were greater than 3cm in size had a higher proportion of correct diagnosis(73.3%) as compared with lesions 3cm or less in size(38.1%). But there was no significant difference between the central and peripheral lung lesions. 5. There were no serious complications to TNAB. In 12.8% of the procedures a pneumothorax developed, indicating a chest tube in 1.6% of the procedures. In 2 cases, minimal hemoptysis developed which did not require treatment. Conclusion : In our experience, TNAB represents a minor and safe procedure, which permits a direct approach to localized malignant lung lesions with a high degree of accuracy.

  • PDF