• Title/Summary/Keyword: cement dust

Search Result 143, Processing Time 0.037 seconds

Cancer Mortality and Incidence in Cement Industry Workers in Korea

  • Koh, Dong-Hee;Kim, Tae-Woo;Jang, Seung-Hee;Ryu, Hyang-Woo
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.243-249
    • /
    • 2011
  • Objectives: Cement contains hexavalent chromium, which is a human carcinogen. However, its effect on cancer seems inconclusive in epidemiologic studies. The aim of this retrospective cohort study was to elucidate the association between dust exposure in the cement industry and cancer occurrence. Methods: The cohorts consisted of male workers in 6 Portland cement factories in Korea. Study subjects were classified into five groups by job: quarry, production, maintenance, laboratory, and office work. Cancer mortality and incidence in workers were observed from 1992 to 2007 and 1997-2005, respectively. Standardized mortality ratios and standardized incidence ratios were calculated according to the five job classifications. Results: There was an increased standardized incidence ratio for stomach cancer of 1.56 (27/17.36, 95% confidence interval: 1.02-2.26) in production workers. The standardized mortality ratio for lung cancer increased in production workers. However, was not statistically significant. Conclusion: Our result suggests a potential association between cement exposure and stomach cancer. Hexavalent chromium contained in cement might be a causative carcinogen.

A Study on the Engineering Properties of Concrete Using Cement Kiln Dust (킬른더스트를 사용한 콘크리트의 공학적 특성에 관한 연구)

  • 김기정;황인성;차천수;김성수;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.267-270
    • /
    • 2003
  • This study is intended to investigate the engineering properties of concrete, in which cement and fine aggregate are replaced with cement kiln dust(CKD), such as the properties of fresh concrete and hardened concrete and hydration heat history, for effective using method of CKD, a by-product produced in the process of making cement. According to the results, as the replacing ratio of CKD increases, slump and air content of concrete decreases remarkably due to an increase of viscosity and filling of the pores. As the properties of setting, initial and final setting time are shortened with an increase of the replacing ratio of CKD, and as the replacement of CKD for fine aggregate increases, setting time is shortened more greatly. Compressive strength increases due to filling of the pores and reduction of air content in comparison with plain concrete. When the replacement ratio of CKD for cement is 10% and 15%, peak temperature of hydration heat lowers slightly, but it goes up in the case of replacement of CKD for fine aggregate. Also, when cement and fine aggregate is replaced with CKD by 2.5% and 7.5% respectively(1C3S) in the case of replacement of CKD for cement and fine aggregate, it is highest.

  • PDF

Effects of waste marble and glass powders on concrete properties and performance

  • Nouraldin Abunassar;Tulin Akcaoglu
    • Advances in concrete construction
    • /
    • v.17 no.4
    • /
    • pp.211-220
    • /
    • 2024
  • Concrete, consisting mainly of cement, water and aggregates; is the most used construction material all over the world. Cement manufacturing industry is one of the carbon dioxide producing sources that contributes to global warming. Therefore, in the last few years, there is a growing interest in using waste materials and by-products as cement replacement materials. Using these kinds of materials as a part of cement replacement reduces the air pollution, cost and also enhances some properties of concretes. In the present work, marble dust (MD) was examined as a partial cement replacement material with seven proportions as 0%, 10%, 20%, 30%, 40%, 50%, 60% and glass powder (GP) was used as an additive, 8% by cement weight, in a 0.55 water-binder ratio concrete. In order to evaluate their effects; workability, strength (compressive, flexural and split tensile), alkalinity, sulphate resistance and ultrasonic pulse velocity tests were performed. Experimental results indicated that with MD replacement and GP addition; there is a loss in the workability but improvement in mechanical properties. With 10% replacement of MD compressive, flexural and tensile strengths increased by 10.7%, 6.2% and 5.3% respectively. Moreover, up to 30% replacement of MD reasonable strength values were obtained.

suspension preheater thermal efficiency 에 대한 종합

  • 한국양회공업협회
    • Cement
    • /
    • s.48
    • /
    • pp.20-28
    • /
    • 1972
  • 본 논문은 Frankenberger씨의 논문을 번역한 것이다. preheater의 열적 성능 평가를 위해선 calcining degree, thermal efficiency 및 calorific efficiency를 이용하고 있으며 1kg의 dust circulation으로 30kcal/kg$\cdot$cli의 연료 소모량을 증가시키고 있어 4단 이상으로 증가시키는 문제도 대두 연구하고 있다.

  • PDF

Control of Suspended Dust in Various Ventilation Systems of Cement Packaging Process (시멘트 포장공정에서 환기시스템에 따른 발생분진의 제어)

  • Lee, Seung-Chul;Kim, Soo-Chang;Noh, Kwang-Chul;Park, Myoung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.463-469
    • /
    • 2009
  • We performed the experimental study on the control of suspended dust in a cement packaging process for various ventilation systems. To effectively remove the dust generated in the cement packaging process, three different kinds of ventilation system, such as local exhaust ventilation, electrostatic scrubber, and local air supply system, were adopted. Dust concentrations in the packaging process were measured with the variation of the airflow rate of the ventilation systems and then their ventilation performance were evaluated. From the results, we knew that the ventilation performance was the best when the local exhaust ventilation and the electrostatic scrubber were simultaneously operated in the packaging process. In the electrostatic scrubber system, the effect of the airflow rate on the indoor dust removal efficiency was negligible so hat he system ust be operated at $2,700m^3/h$ for saving power consumption.

Physical Effect of Adding Stone Dust Sludge on the Properties of Cement Mortar (석분슬러지 혼입이 시멘트 모르타르 특성에 미치는 물리적 영향)

  • Seo, Jun-Yeong;Choi, Seon-Jong;Kang, Su-Tae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.2
    • /
    • pp.152-158
    • /
    • 2015
  • In order to investigate the feasibility of stone dust sludge as fine aggregate, an experimental study was performed on cement mortar with stone dust sludge. fresh mortar properties and strength with various stone dust sludge replacement ratios were estimated. the replacement ratio adopted in this study was 0, 10, 20, 30%. Flow, air content, and rheological properties were considered as properties of fresh mortar. Compressive strength and flexural tensile strength were measured for strength. The results are as follows. Higher amount of stone dust sludge caused reduction in slump and air content. In the rheological properties, both yield stress and plastic viscosity increased as stone dust sludge content increased up to 20% replacement ratio, but there were no remarkable difference between 20 and 30%. Yield stress increased drastically between 10 and 20%. Compressive and flexural tensile strength results indicated that the strength variation was not significant according to stone dust sludge content, but the strength gain in the early age by adding stone dust sludge was evident. the strength at the age of 28 days however did not show noticeable effect of adding stone dust sludge.

Understanding the Properties of Cement Mortar with Employment of Stone Dust considering Particle Size Distribution (입도분포를 고려한 석분 사용에 따른 시멘트 모르타르 성질의 변화 이해)

  • Kang, Su-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.715-723
    • /
    • 2017
  • This study investigates the properties of a high-performance cementitious composite with partial substitution of stone dust for fine aggregate. The relationship between the properties and particle size distribution was analyzed using several analytical models. Experiments were carried out to examine the flowability, rheology, and strength of cement mortars with different stone-dust replacement ratios of 0-30 wt.%. The results showed improved flowability, lower rheological parameters (yield stress and plastic viscosity), and improved strength as the amount of stone dust increased. These results are closely related to the packing density of the solid particles in the mortar. The effect was therefore estimated by introducing an optimum particle size distribution (PSD) model for maximum packing density. The PSD with a higher amount of stone dust was closer to the optimum PSD, and the optimization was quantified using RMSE. The improvement in the PSD by the stone dust was proven to affect the flowability, strength, and plastic viscosity based on several relevant analytical models. The reduction in yield stress is related to the increase of the average particle diameter when using stone dust.

Development and Basic Performance Characterization of Neutralized Fabric Filter (제전사여과포의 개발 및 기초성능 규명)

  • 박영옥;구철오;임정환;김홍룡;손재익;이영우
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 1998
  • A neutralized fabric filter of which major raw materials were polyester and stainless steel fibers was developed and its physiochemical properties and basic filter characteristics were investigated. Four finds of dusts generated in the typical domestic industry were used, which were coke dust from a steel manufacturing process, cement dust from a cement manufacturing process, flu ash from a fluidized-bed combustor, and incinerator ash from a waste plastics incinerator. The physicochemical properties of the neutralized fabric filter were analyzed in terms of changes in tensile strength and initial elastic modulus under $SO_2$ and $NO_2$ atmospheres, mean flow pore pressure, bubble point pore diameter, mean flow pore diameter, and pore size distribution. In addition, the pressure drop, dust penetration, and figure of merit for the fabric filter were investigated in a bench-scale filter testing unit. The pressure drop increased as the filtration velocity and dust loading increased, and its increasing shape depended on the type of dust. The dust penetration rapidly decreased as the dust loading increased irrespective of the type of dust. The figures of merit for the fabric filters increased in the early stage of filtration and then showed rapid decreases followed maintaining a constant level.

  • PDF

Fresh and hardened properties of concrete containing cold bonded aggregates

  • Thomas, Job;B., Harilal
    • Advances in concrete construction
    • /
    • v.2 no.2
    • /
    • pp.77-89
    • /
    • 2014
  • The properties of fresh and hardened concrete made using three types of artificial cold bonded aggregates are determined. The properties, namely, slump, water absorption, compressive strength and splitting tensile strength of concrete containing artificial aggregate are reported. The variables considered are aggregate type and water-to-cement ratio. Three types of cold bonded aggregates are prepared using fly ash and quarry dust. The water-to-cement ratio of 0.35, 0.45, 0.55 and 0.65 is used. The test result indicates that artificial aggregates can be recommended for making the concrete up to a strength grade of 38 MPa. The use of quarry dust in the production of artificial aggregate mitigates environmental concerns on disposal problems of the dust. Hence, the alternate material proposed in this study is a green technology in concrete production.