• Title/Summary/Keyword: cell ELISA

Search Result 921, Processing Time 0.03 seconds

Enzyme-linked immunosorbent assay (ELISA) for the detection of RVS (Retrovirus of Salmonid) (ELISA법을 이용한 연어과 어류의 RVS 검출(Retrovirus of Salmonid) 검출)

  • Oh, Myung-Joo;Yoshimizu, Mamoru
    • Journal of fish pathology
    • /
    • v.9 no.2
    • /
    • pp.169-176
    • /
    • 1996
  • An indirect double antibody enzyme-linked immunosorbent assay (ELISA) was developed for rapid detection of a new virus isolated from abnormally swimming salmonid fish, RVS (Retrovirus of salmonid). Results using brain tissue homogenates, and infected cell cultures are described. The sensitivity of the methods is $10^{2.6}$ $TCID_{50}/100{\mu}l$ of the examined cell culture fluid. The specificity was confirmed by the ELISA inhibition test and virological examinations. Viral antigen could be detected in artificially infected fish tissue homogenates. The assay will allow the diagnosis of RVS-infected fish within a day.

  • PDF

Development of ELISA System for Screening of Specific Binding Inhibitors for Src Homology (SH)2 Domain and Phosphotyrosine Interactions

  • Lee, Sang-Seop;Lee, Kyung-Im;Yoo, Ji-Yun;Jeong, Moon-Jin;Park, Young-Mee;Kwon, Byoung-Mog;Bae, Yun-Soo;Han, Mi-Young
    • BMB Reports
    • /
    • v.34 no.6
    • /
    • pp.537-543
    • /
    • 2001
  • In the present study, an in vitro ELISA system to assess the interaction between Src homology (SH)2 domains and phosphotyrosine that contain peptides was established using purified GST-conjugated SH2 proteins and synthetic biotinylated phosphotyrosine that contain oligopeptides. The SH2 domains bound the relevant phosphopeptides that were immobilized in the streptavidin-coated microtiter plate in a highly specific and dose-dependent manner. The epidermal growth factor receptor (EGFR)-, T antigen (T Ag)-, and platelet-derived growth factor receptor (PDGFR)-derived phosphopeptides interacted with the growth factor receptor binding protein (Grb)2/SH2, Lck/SH2, and phosphatidyl inositol 3-kinase (PI3K) p85/SH2, respectively. No cross-reactions were observed. Competitive inhibition experiments showed that a short phosphopeptide of only four amino acids was long enough to determine the binding specificity. Optimal concentrations of the GST-SH2 fusion protein and phosphopeptide in this new ELISA system for screening the binding blockers were chosen at 2nM and 500nM, respectively. When two candidate compounds were tested in our ELISA system, they specifically inhibited the Lck/SH2 and/or p85/SH2 binding to the relevant phosphopeptides. Our results indicate that this ELISA system could be used as an easy screening method for the discovery of specific binding blockers of protein-protein interactions via SH2 domains.

  • PDF

Comparative Analysis of Screening Results from Various ELISA Formats Used for Detection of Anti-Erythropoietin Antibodies in Korean Patients

  • Ha, Sung-Kyu;Yang, Seung-Ju;Shin, Sug-Kyun;Jo, Young-Il;Baek, Kyung-Min;Hong, Seung-Hwa;Pack, Seung-Pil;Kim, Sung-Jo;Heo, Tae-Hwe
    • Biomolecules & Therapeutics
    • /
    • v.18 no.2
    • /
    • pp.184-190
    • /
    • 2010
  • Clinical cases of pure red cell aplasia (PRCA) have been reported during the recombinant human erythropoietin (EPO) therapy for the anemia patients. PRCA is a rare hematological disorder leading to a severe anemia due to an almost complete stop of red blood cell production. Antibody (Ab)-associated PRCA is caused by the EPO-neutralizing Abs that eliminate the biological activity of EPO. In order to detect anti-EPO Abs in human sera, we performed conventional ELISA, directly coated bridging ELISA, and streptavidin coated bridging ELISA, and compared their sensitivity and specificity. Some false positive results were obtained in the conventional ELISA. One positive sample was detected successfully by streptavidin coated bridging ELISA, which was not appeared in the directly coated bridging ELISA. In conclusion, streptavidin coated bridging ELISA was substantially sensitive and specific format and one out of sixty-eight serum samples was proved to be anti-EPO positive.

Application of the Enzyme-linked Immunosorbent Assay to the Serodiagnosis of Typhoid Fever (장티푸스의 혈청학적 진단에 효소결합면역측정법(Enzyme-linked Immunosorbent Assay)의 적용 실험)

  • Kye, Ki-Shik;Kim, Yae-Hum;Choi, Kang-Won;Hwang, Eung-Soo;Kook, Yoon-Ho;Lee, Seung-Hoon;Cha, Chang-Yong
    • The Journal of the Korean Society for Microbiology
    • /
    • v.18 no.1
    • /
    • pp.73-85
    • /
    • 1983
  • The advantages of the enzyme-linked immunosorbent assay(ELISA) are its sensitivity and its simplicity in detecting IgM and IgG antibodies. For applying the ELISA to the diagnosis of typhoid fever, first of all, experiments were performed to determine which concentration of killed whole cell antigens and lipopolysaccharide(LPS) antigens of S. typhi(0.901 w) were optimally coated to the wells of the polystyrene and polyvinylchloride microplate, using the hyperimmune sera from rabbits against S. typhi. By using both kinds of antigens of S. typhi adsorbed to the ELISA microplate, the changing patterns of IgG and IgM antibodies in the sera from rabbits responding to the killed whole cell antigens of S. typhi(0901 w) during the prolonged immunization were serially traced by the ELISA. At the same time, the level of antibodies against S. typhi in sera fron patients with typhoid fever and from normal healthy persons were measured by the ELISA employing the killed whole cell antigens and LPS antigens as the coating antigens. The results obtained were summerized as follow: 1. The optimal concentration of the killed whole cell antigens, which were more easily adsorbed to the polystyrene plate than the polyvinylchloride plate, was $10^8cells/ml$ of carbonate buffer(pH. 9.6) on the wells of the polystyrene plate when treated at $37^{\circ}C$ for 4 hours. On the other hand, the optimal concentration of lipopolysaccharide antigens, which were adsorbed only to the polyvinylchloride plate, was $100{\mu}g/ml$ of carbonate buffer(pH. 9.6) on the wells of the polyvinylchloride plate when treated at $37^{\circ}C$ for 4 hours. 2. IgM antibody response were dominating in rabbits responding to the killed whole cell antigens of S. typhi(0.901 w), and were more specific to the LPS antigens than to the killed whole cell antigens in the ELISA. Good correlations were made between the IgM titers by the ELISA and the aggglutinating titers of sera from the immunized rabbits. 3. Both IgG and IgM agglutination titers by the ELISA in sera from most of patients with typhoid fever were above 1:320 but those in sera from most of normal, healthy persons were below 1:80. 4. There were close correlations between the antibody titers by the ELISA and the agglutinating titers to the killed whole cell antigens in the tested human sera, IgM titers being more correlated with the agglutinating titers than IgG titers. But a little correlations were made between the antibody titers by the ELISA and the agglutinating titers to the LPS antigens. 5. IgM titers in the tested human sera were similar to IgG titers detected by the ELISA employing the killd whole cells antigens and the LPS antigens. 6. Good correlations were made between the antibody titers demonstrated by the ELISA performed on the killed whole cell antigens and the LPS antigens as the different, coating antigens on the ELISA microplates.

  • PDF

Development of an Enzyme-Linked Immunosorbent Assay Method for Residual Host Cell derived Proteins in Recombinant Antibody Drug Production (재조합 항체의약품의 생산시 생산세포주 유래 단백질 검출을 위한 ELISA 방법 개발)

  • Joung, Chan-Hi;Lim, Sang-Min;Koo, Yoon-Mo;Lee, Yong-Yoon;Son, Young-Su;Kim, Hyun-Il;Park, Heung-Rok
    • KSBB Journal
    • /
    • v.21 no.3
    • /
    • pp.212-219
    • /
    • 2006
  • The purpose of this study was to develop a assay system of host cell-derived residual proteins in final pharmaceutical products. Accurate and simple assay system for host cell-derived proteins(HCPs) is very important test item in pharmaceutical qualification control. In this study, methods for quantification of residual HCPs in recombinant anti-GPIIbIIIa antibody were developed using a process-specific immunoligand assay which was based on the Enzyme linked Immunosorbent assay(ELISA) system. The assay had a detection limit of 10.8 ng/ml of HCPs with a product concentration of 1 mg/ml. The practical implication of these results is that the developed ELISA system can be used for HCPs qualification control and this system will be applicable to develop another ELISA system of different antibody drug.

EFFECT OF TITANIUM SURFACE ROUGHNESS ON CELL ADHESION OF HUMAN OSTEOBLAST-LIKE CELLS (MG63)

  • Yim Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.3
    • /
    • pp.261-266
    • /
    • 2004
  • Statement of problem. The effects of surface roughness have not or insufficiently been analyzed on earlier events such as cell adhesion though cell behavior most germane to implant performance is cell adhesion. Purpose. The purpose of this study was to evaluate cell adhesion of osteoblast-like cells (MG63) onto three types of titanium disks with varying roughness using the Elisa assay. Materials and methods. Representative disks from each group (SLA, HA, machined) were subjected to surface analysis and surface roughness was measured by the optical interferometer (Accura 2000, Intekplus Co., Seoul, Korea). Following this, MG63 cells were cultured on the titanium disks and released. Cell adhesion measurements using the Elisa assay were performed specifically at three points: after 24, 48, and 72 hours of culture. Results. Among the 3 types of surface analyzed, the SLA surface was the roughest with a Ra value of $1.114{\mu}m$ followed by HA coated surface and machined surface, consecutively. The optical density values for the SLA surface group was significantly higher than that of the machined and HA coated surface groups following 24 and 48 hours of culture. The cell culture on HA coated surface showed significantly higher values compared to the machined surface following 24, 48 and 72 hours of culture. Conclusion. The results suggest that surface treatment of titanium surfaces enhanced cell adhesion of human osteoblast-like cells (MG63).

Protein A of Staphylococcus hyicus subsp hyicus isolated from pigs (돼지에서 분리한 Staphylococcus hyicus subsp hyicus의 protein A)

  • Kim, Do-kyoung;Yeo, Sang-geon
    • Korean Journal of Veterinary Research
    • /
    • v.30 no.2
    • /
    • pp.187-192
    • /
    • 1990
  • The Presence and quantity of protein A in Staphylococcus hyicus subsp hyicus isolates from pigs were determined by indirect hemagglutination test and enzyme-linked immunosorbent assay(ELISA). Cell-bound and extracellular protein A was demonstrated in 87.7% and 36.0% of 489 isolates, respectively, by indirect hemagglutination test. When contents of the protein A were estimated by ELISA method, all of the isolates that were positive to protein A in indirect hemagglutination test produced extracellular protein A of less than 1ng/ml. Most of the isolates produced cell-bound protein A of less than 1ng/ml, whereas 28 isolates produced 1 to 35ng/ml and 11 isolates produced 25 to 108ng/ml.

  • PDF

Development of an Indirect Non-Competitive Enzyme-Linked Immunosorbent Assay for the Detection of Cronobacter muytjensii in Infant Formula Powder (유아용 조제분유 내 Cronobacter muytjensii 검지를 위한 간접 비경합 면역분석법의 개발)

  • Song, Xinjie;Kim, Myunghee
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.4
    • /
    • pp.936-944
    • /
    • 2013
  • Cronobacter muytjensii is an important foodborne pathogen as a potential risk in infant formula powder (IFP). To develop a new and sensitive method for the detection of Cronobacter spp. in IFP, an immunoglobulin G (IgG) specific for C. muytjensii (formerly known as Enterobacter sakazakii ATCC 51329) was developed. Further, an indirect noncompetitive enzyme-linked immunosorbent assay (INC-ELISA) was developed by using the anti-C. muytjensii IgG. As a result, this newly developed INC-ELISA method was found very sensitive for C. muytjensii with detection limit of $6.5{\times}10^3CFU/ml$ in pure culture and 1 cell/25 g of IFP. This INC-ELISA method also displayed excellent specificity for C. muytjensii showing no cross-reactivity with other strains of Cronobacter genus and 11 other foodborne pathogenic strains. These results show that the developed INC-ELISA method was very sensitive, efficient, and rapid for the detection of C. muytjensii. Hence, this method could be applied to the development of diagnostic kits for the rapid and easy detection of C. muytjensii.

Study on the production and management of aquatic animals : direct detection of Edwardsiella tarda using an enzyme linked immunosorbent assay (수생산물의 생산과 관리에 관한 기초연구 : ELISA법을 이용한 Edwardssiella tarda의 직접 검출)

  • Chung, Soon-Yoon;Sohn, Sang-Gyu;Chung, Joon-Ki;Huh, Min-Do;Jeong, Hyun-Do
    • Journal of fish pathology
    • /
    • v.10 no.2
    • /
    • pp.75-86
    • /
    • 1997
  • Solid phase enzyme linked immunosorbent assay (ELISA) was developed to detect the whole cells of Edwardsiella tarda from infected tissues of flounder. Cross-reaction test was performed by ELISA against fish pathogens such as A. hydrophila ATCC7966. V. anguillarum HYUFP5001, Y, ruckeri 11-4, E. ictaluri and Streptococcus sp. NG8206. Rabbit anti-E, tarda Edk-2 sera highly cross-reacted with A. hydrophila ATCC7966 and V. anguillarum HUFP5001. However, the cross-reaction was removed by using the anti-serum pre-adsorbed with A, hydrophila ATCC7966 FKC. The intra-species cross-reaction among E. tarda isolates was very high. ELISA with the whole cell antigens present in tissue homogenate appeared with highly decreased sensitivity, presumably by the co-coating of lipid or proteins in tissues. Thus, it would be necessary to use the infected tissue homogenates diluted more than 100 times with PBS for diagnosis. Interestingly, compared with the using of FKC antigen, the direct detection of viable cells in tissue homogenate showed more sensitive results with detection limit of $1{\times}10^3$ cells/ml in buffer or diluted tissue homogenate. Consequently, the ELISA method developed in this study was specific, rapid and sensitive for diagnosing edwardsiellosis.

  • PDF

Development of Direct Competitive Enzyme-Linked Immunosorbent Assay using Monoclonal Antibody (MAb) against Sulfamthazine (SMZ) and Establishment of Application Condition for Milk Sample (설파메타진에 단클론성 항체를 이용한 직접경쟁효소면역분석법의 개발과 우유 시료 적용 조건 확립)

  • Shim, Won-Bo;Mun, Chun-Sun;Kim, Jung-Sook;Choe, Ju-Mi;Kim, Ji-Hun;Park, Seon-Ja;Kang, Sung-Jo;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.176-182
    • /
    • 2006
  • Sensitive and specific monoclonal antibody (MAb) was produced from hybridoma (1H11-5) obtained by fusion of myeloma cell (V653) and spleen cell isolated from mouse immunized sulfamthazine (SMZ)-HG-KLH. Direct competitive ELISA was developed for rapid detection of SMZ in milk samples using MAb against SMZ with optimized conditions between MAb and SMZ-HG-HRP conjugate, and applicable conditions for analysis of milk samples were established. Detection range of immunoassay was 0.1 to 100 ppb. Recoveries from spiked raw milk and processed milk samples averaged 82.1-120.7 and 82.1-97.1%, respectively.