• Title/Summary/Keyword: cavity volume

Search Result 329, Processing Time 0.024 seconds

An Experimental Study for Estimation of Compression Settlement on Embankment Material Under Self-weight (성토체 압축침하량 산정에 관한 연구)

  • Kwon, Jeongeun;Noh, Ilkwon;Jung, Juyoung;Im, Jongchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.33-40
    • /
    • 2009
  • In earthwork projects, the designer considers cut and fill balance for minimizing earthwork which may significantly decrease construction costs. Despite carrying out considerable earthwork design, the decrease in volume of earth occurs in construction sites because of embankment settlement under self-weight, consolidation settlement of soft ground, cavity filling and soil loss due to rainfall-runoff. To reflect the decrease in volume of earth, the specifications for road construction just give shrinkage factors in embankment for soils without consideration of embankment settlement under self-weight. In this study, the computational method is used to estimate the amount of embankment settlement under self-weight developed by Iseda (1972) and Ishii (1976). This research shows that the total compression settlements are between 3 to 10 percent of embankment height according to the property of embankment material and embankment height. As a result, the designer should consider the compression settlement on embankment material under selt-weight.

  • PDF

A Study of Small Radiation Dosimeter by Using Microfilm and Carbon Elecrtode (마이크로필름과 탄소막 전극을 이용한 소형방사선측정기 개발에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • We developed very small parallel plate radiation detector by using our existing experience of mating radiation dosimeter and capability of analyzing characteristics of dosimeter. The radiation detector was consisted of microfilm and carbon electrode. The detector was parallel plate type of all-filled ionization chamber. The ionization chamber had been fabricated using an acrylic plate for the air cavity and carbon coated microfilm for electrical configuration. The alr gap between two electrodes was 0.48 mm. The diameters of collect electrode and guard electrode were 3.3 mm, 5 mm respectively. The diameter of high voltage electrode was 5 mm. Nominal sensitive volume of the chamber was 0.016 ㎤. The major parameters of the chamber characteristics such as leakage current, reproducibility, dose rate effect, and polarity effect were measured. The experimental results were as followings. Leakage current was 0.1 pA. Standard deviation of reproducibility was less than 0.1%. Dose rate effect was less than 1.5%. Polarity effect was less than 2.4%. These data were comparable to those of commercially available dosimetric system for QA-purpose. As the result, we found that the radiation detector consisting of the ionization chamber, microfilm and carbon electrode, was satisfactory for the purpose of the small field dosimetry in size and characteristics. In the future, We will try to refine the dosimeter for use in very small volume.

  • PDF

Selection of Various Free Flap Donor Sites in Palatomaxillary Reconstruction (구개상악재건을 위한 유리피판술에서 다양한 공여부의 선택)

  • Yoon, Do-Won;Min, Hee-Jun;Kim, Ji-Ye;Lee, Won-Jae;Chung, Seum;Chung, Yoon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.8-13
    • /
    • 2011
  • Purpose: A palatal defect following maxillectomy can cause multiple problems like the rhinolalia, leakage of foods into the nasal cavity, and hypernasality. Use of a prosthetic is the preferred method for obturating a palate defect, but for rehabilitating palatal function, prosthetics have many shortcomings. In a small defect, local flap is a useful method, however, the size of flap which can be elevated is limited. In 12 cases of palatomaxillary defect, we used various microvascular free flaps in reconstructing the palate and obtained good functional results. Method: Between 1990 and 2004, 12 patients underwent free flap operation after head and neck cancer ablation, and were reviewed retrospectively. Among the 12 free flaps, 6 were latissimus dorsi myocutaneous flaps, 3 rectus abdominis myocutaneous flaps, and 3 radial forearm flaps. Result: All microvascular flap surgery was successful. Mean follow up time was 8 months and after the follow up time all patients reported satisfactory speech and swallowing. Wound dehiscence was observed in 4 cases, ptosis was in 1 case and fistula was in 1 case, however, rhinolalia, leakage of food, or swallowing difficultly was not reported in the 12 cases. Conclusion: We used various microvascular flaps for palatomaxillary reconstruction. For 3-dimensional flap needs, we used the latissimus dorsi myocutaneous flap to obtain enough volume for filling the defect. Two-dimensional flaps were designed with latissimus dorsi myocutaneous flap, rectus abdominis flap and radial forearm flap. For cases with palatal defect only, we used the radial forearm flap. In palatomaxillary reconstruction, we can choose various free flap techniques according to the number of skin paddles and flap volume needed.

  • PDF

Forging Effect of Al6061 in Casting/Forging Process (주조/단조 공정에서 Al6061의 단조효과에 관한 연구)

  • Kwon, Oh-Hyuk;Bae, Won-Byong;Cho, Jong-Rae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.45-50
    • /
    • 2005
  • In this study, the casting/forging process was applied in manufacturing a low control arm, in order to prove that application of casting/forging process to Al6061 is likely to get the effect of light weight compared with existing steel products and to reduce the cost of materials. Firstly, In order to set up the optimum casting condition of the forging material, Al6061, casting experiments were carried out by controlling pouring temperature of the aluminum for casting, mold temperature, and pouring time. $700^{\circ}C$ pouring temperature, $300^{\circ}C$ mold temperature and 10-second pouring time were taken into account as the optimum casting conditions. With respect to a hot forging test, it is practiced on the basis of a temperature of materials, strain rate, and reduction rate so as to observe each microstructure and examine strain-stress curve simultaneously; examine tensile test and hardness test; eventually set up the optimum hot forging condition. A hot forging test, tensile test, hardness experiment, and microstructure observation were carried out on condition of $70\%$ reduction rate, $500^{\circ}C$ temperature of materials, and 1 strain rate. As a result of those experiments, 330MPa tensile strength, $16.4\%$ elongation, and 122.8Hv hardness were recorded. In oder to get a sound preform which has no unfitting cavity and less flash, two preforms were proposed on the basis of volume rate of the final product; the optimum volume rate of preform for the low control arm was $115\%$. In conclusion, it is confirmed that using the forging material rather than casting materials in casting/forging process is likely to get more superior mechanical properties. Compared with Al6061, performed by means of general forging, moreover, cast/forged Al6061 can not only stimulate productivity by reducing production processes, but cut down the cost of materials by reusing forging scraps.

The Neuroprotective Effect of Treatment of Valproic Acid in Acute Spinal Cord Injury

  • Yu, Song-Hee;Cho, Dae-Chul;Kim, Kyoung-Tae;Nam, Kyung-Hun;Cho, Hee-Jung;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.4
    • /
    • pp.191-198
    • /
    • 2012
  • Objective: Valproic acid (VPA), as known as histone deacetylase inhibitor, has neuroprotective effects. This study investigated the histological changes and functional recovery from spinal cord injury (SCI) associated with VPA treatment in a rat model. Methods: Locomotor function was assessed according to the Basso-Beatlie-Bresnahan scale for 2 weeks in rats after receiving twice daily intraperitoneal injections of 200 mg/kg VPA or the equivalent volume of normal saline for 7 days following SCI. The injured spinal cord was then examined histologically, including quantification of cavitation. Results: Basso-Beatlie-Bresnahan scale scores in rats receiving VPA were significantly higher than in the saline group (p<0.05). The cavity volume in the VPA group was Significantly reduced compared with the control (saline-injected) group (p<0.05). The level of histone acetylation recovered in the VPA group, while it was significantly decreased in the control rats (p<0.05). The macrophage level was significantly decreased in the VPA group (p<0.05). Conclusion: VPA influences the restoration of hyperacetylation and reduction of the inflammatory reaction resulting from SCI, and is effective for histology and motor function recovery.

Finite Element Analysis of Powder Injection Molding Filling Process Including Yield Stress and Slip Phenomena (항복응력과 미끄럼현상을 고려한 분말사출성형 충전공정의 유한요소해석)

  • 박주배;권태헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1465-1477
    • /
    • 1993
  • Powder Injection Molding(PM) is an advanced and complicated technology for manufacturing ceramic or metal products making use of a conventional injection molding process, which is generally used for plastic products. Among many technologies involved in the successful PIM, injection molding process is one of the key steps to form a desired shape out of powder/binder mixtures. Thus, it is of great importance to have a numerical tool to predict the powder injection molding filling process. In this regard, a finite element analysis system has been developed for numerical simulations of filling process of powder injection molding. Powder/polymer mixtures during the filling pro cess of injection molding can be rheologically characterized as Non-Newtonian fluids with a so called yield phenomena and have a peculiar feature of apparent slip phenomena on the wall boundaries surrounding mold cavity. Therefore, in the present study, a physical modeling of the filling process of powder/polymer mixtures was developed to take into account both the yield stress and slip phenomena and a finite element formulation was developed accordingly. The numerical analysis scheme for filling simulation is accomplished by combining a finite element method with control volume technique to simulate the movement of flow front and a finite difference method to calculate the temperature distribution. The present study presents the modeling, numerical scheme and some numerical analysis results showing the effect of the yield stress and slip phenomena.

A prospective study on the effectiveness of newly developed autogenous tooth bone graft material for sinus bone graft procedure

  • Jun, Sang-Ho;Ahn, Jin-Soo;Lee, Jae-Il;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.528-538
    • /
    • 2014
  • PURPOSE. The purpose of this prospective study was to evaluate the effectiveness of newly developed autogenous tooth bone graft material (AutoBT)application for sinus bone graft procedure. MATERIALS AND METHODS. The patients with less than 5.0 mm of residual bone height in maxillary posterior area were enrolled. For the sinus bone graft procedure, Bio-Oss was grafted in control group and AutoBT powder was grafted in experimental group. Clinical and radiographic examination were done for the comparison of grafted materials in sinus cavity between groups. At 4 months after sinus bone graft procedure, biopsy specimens were analyzed by microcomputed tomography and histomorphometric examination for the evaluation of healing state of bone graft site. RESULTS. In CT evaluation, there was no difference in bone density, bone height and sinus membrane thickness between groups. In microCT analysis, there was no difference in total bone volume, new bone volume, bone mineral density of new bone between groups. There was significant difference trabecular thickness ($0.07{\mu}m$ in Bio-Oss group Vs. $0.08{\mu}m$ in AutoBT group) (P=.006). In histomorphometric analysis, there was no difference in new bone formation, residual graft material, bone marrow space between groups. There was significant difference osteoid thickness ($8.35{\mu}m$ in Bio-Oss group Vs. $13.12{\mu}m$ in AutoBT group) (P=.025). CONCLUSION. AutoBT could be considered a viable alternative to the autogenous bone or other bone graft materials in sinus bone graft procedure.

Combination of a new ultrasonic tip with rotary systems for the preparation of flattened root canals

  • Karina Ines Medina Carita Tavares ;Jader Camilo Pinto ;Airton Oliveira Santos-Junior ;Fernanda Ferrari Esteves Torres ;Juliane Maria Guerreiro-Tanomaru ;Mario Tanomaru-Filho
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.56.1-56.11
    • /
    • 2021
  • Objectives: This study evaluated 2 nickel-titanium rotary systems and a complementary protocol with an ultrasonic tip and a small-diameter instrument in flattened root canals. Materials and Methods: Thirty-two human maxillary second premolars with flattened canals (buccolingual diameter ≥4 times larger than the mesiodistal diameter) at 9 mm from the radiographic apex were selected. The root canals were prepared by ProDesign Logic (PDL) 30/0.01 and 30/0.05 or Hyflex EDM (HEDM) 10/0.05 and 25/0.08 (n = 16), followed by application of the Flatsonic ultrasonic tip in the cervical and middle thirds and a PDL 25/0.03 file in the apical third (FPDL). The teeth were scanned using micro-computed tomography before and after the procedures. The percentage of volume increase, debris, and uninstrumented surface area were analyzed using the Kruskal-Wallis, Dunn, Wilcoxon, analysis of variance/Tukey, and paired and unpaired t-tests (α = 0.05). Results: No significant difference was found in the volume increase and uninstrumented surface area between PDL and HEDM (p > 0.05). PDL had a higher percentage of debris than HEDM in the middle and apical thirds (p < 0.05). The FPDL protocol resulted in less debris and uninstrumented surface area for PDL and HEDM (p < 0.05). This protocol, with HEDM, reduced debris in the middle and apical thirds and uninstrumented surface area in the apical third (p < 0.05). Conclusions: High percentages of debris and uninstrumented surface area were observed after preparation of flattened root canals. The HEDM, Flatsonic tip, and 25/0.03 instrument protocol enhanced cleaning in flattened root canals.

Radiotherapic Valuation of Paraffin Wax for Patients with Oral Cancer (구강암 환자 치료시 치과용 기초상 왁스(Paraffin Wax)의 유용성 평가)

  • Na, Kyoung-Su;Seo, Seuk-Jin;Lee, Je-Hee;Yoo, Sook-Heun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • Purpose: This study is designed to investigate radiotherapic valuation of Paraffin Wax, which is newly formed for this study and generally utilized in dentistry, and Mouth Piece and Putty impression, which are commonly used in radiotherapy, for oral cavity as a compensator. Materials and Methods: Each compensator was formed by $10{\times}10{\times}1cm$ and measured radiation dose attenuation ratio with reference of water phantom which is made of tissue-equivalent materials. Two patients with oral cancer underwent DRR (Digitally Reconstructed Radiogrph) of Offline Review Program of Aria System and Portal vision for 5 times for each material to evaluate reproducibility by each filling materials. Moreover, MU (monitor unit) changes by dose absorption were considered in the case of inevitable implication of an filling materials in the range for radiotherapy. Results: Radiation dose attenuation ratios were shown -0.7~+3.7% for Mouth Piece, +0.21~+0.39% for Paraffin Wax and -2.71~-1.76% for Putty impression. Error ranges of reproducibility of positions were measured ${\pm}3mm$ for Mouth Piece, ${\pm}2mm$ for Paraffin Wax and ${\pm}2mm$ mm for Putty impression. Difference of prescription MU from dose absorption with an filling material increased +7.8% (250 MU) in Putty impression and -0.9% (230 MU) in Paraffin Wax as converted into a percentage from the standard phantom, Water 232 MU. Conclusion: Dose reduction of boundary between cavity and tissue was observed for Mouth Piece. Mouth Piece also had low reproducibility of positions as it had no reflection of anatomy of oral cavity even though it was a proper material to separate Maxilla and Mandible during therapy. On the other hand, Putty impression was a suitable material to correctly re-position oral cavity as before. However, it risked normal tissues getting unnecessary over irradiation and it caused radiation dose decrease by -2.5% for 1cm volume in comparison of it of water phantom. Dose reduction in Paraffin Wax, Fat Tissue-Equivalent Material, was smaller than other impressions and position reproducibility of it was remarkable as it was possible to make an anatomy reflected impression. It was also well fitted to oral cavity to transfer radiation dose planned in radiotherapy. Thus, Paraffin Wax will be an ideal material in radiotherapy for patients with oral cancer.

  • PDF

Studies on the Anticancer Effect of Apigenin in KB Cell Xenograft Nude Mouse Model (구강암 세포주를 이종 이식한 누드마우스에서 apigenin의 경구투여에 따른 항암효능에 관한 연구)

  • Lee, Jin-Seok;Seo, Hyeong-Seok;Kim, So-Jung;Kim, Hyeong-Jin;Kim, Jin;Lee, Seung-Ho;Park, Young-Seok;Park, Byung-Kwon;Kim, Byeong-Soo;Kim, Sang-Ki;Jung, Ji-Youn
    • Journal of Life Science
    • /
    • v.20 no.10
    • /
    • pp.1519-1524
    • /
    • 2010
  • Apigenin (4', 5, 7-trihydroxyflavone), a common dietary flavonoid abundantly present in fruits and vegetables, has shown remarkable anti-proliferative effects against various malignant cell lines. To observe the anti-proliferative effects, oral cavity cancer cell lines, $6{\times}10^3$ cells/well (96 well plate) of KB oral cavity tumor cells were plated and 24 hr later treated with apigenin for one day, after which MTT assay was performed. Apigenin induced cell death in a dose-dependent manner after incubation. Cell viability was significantly decreased in the group treated with 100 ${\mu}M$ apigenin for 24 hr (p<0.05) compared to the control group. To assess apoptosis, the nuclei of KB cells were stained with DAPI. The presence of chromatin condensation in the apigenin treated cells was detected on a fluorescent microscope (${\times}200$). We investigated the in vivo growth inhibitory effects of apigenin on oral cavity cancer KB tumor xenograft subcutaneously implanted in male nude mice. Apigenin was administered to mice by gavage at doses of 25 and 50 mg/kg/day in 0.2ml of PBS. Tumor volume was significantly decreased in 25 and 50 mg/kg apigenin-administration groups compared to the control group. For apoptosis analysis, TUNEL staining was performed. A significant increase in TUNEL positive cells was found in the 25 mg/kg apigenin administration group compared to the non- apigenin administration group. Histopathological changes were not observed. These results indicate that apigenin inhibits oral cavity cancer cell growth through the induction of apoptosis.