• Title/Summary/Keyword: cathode ray tube

Search Result 100, Processing Time 0.056 seconds

A study on the non-contact measurement for the temperature of shadow mask of Cathode Ray Tube using InSb photo sensor (인듐안티모나이드 포토 센서를 이용한 CRT 섀도우 마스크의 비접촉 온도 측정에 관한 연구)

  • 강대진;박정우;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.15-20
    • /
    • 1997
  • This paper presents the experimental study of the non-contact temperature measurement for the shadow mask of cathode ray tube using InSb sensor. At present, High resolution of CRT(Cathode Ray Tube) is needed broadly; therefore, the measurement of temperature distribution of shadow mask in CRT during operation is important to analyze the thermal deformation of shadow mask. Most of the studies could not measure the temperature distribution of shadow mask precisely. We studied the temperature dis- tribution of shadow mask using InSb photo sensor for 17" cathode ray tube (CRT). Experiments using ther- mocouple are performed to validate the results of non-contact measurement. The results agree well with those results of non-contact method using InSb sensor.nsor.

  • PDF

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.

Application of Carbon Naotube to the Electron Gun of the Cathode Ray Tube (탄소 나노 튜브의 음극선관용 전자총 응용)

  • Ju, Byeong-Gwon;Jang, Yun-Taek;Lee, Yun-Hui
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.3
    • /
    • pp.121-124
    • /
    • 2002
  • CNTs(Carbon Nano Tube) were employed as an electron source in electron-gun of CRT(Cathode-Ray Tube). The CNTs were grown on the Si substrates and the electron gun by LP-CVD(Low Pressure-Chemical Vapor Deposition). Their physical and field emission property satisfied the requirements of the electron gun of CRT. The fabricated electron gun was inserted into 19 inch-sifted CRT and its operating properly was evaluated for practical usage.

Design of Soft X-ray Tube and Simulation of Electron Beam by Using an Electromagnetic Finite Element Method for Elimination of Static Electric Field (전자기 유한요소법 전자빔 시뮬레이션을 이용한 정전기장 제거용 연한 X-선관 설계 특성 연구)

  • Park, Tae-Young;Lee, Sang-Suk;Park, Rae-Jun
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.2
    • /
    • pp.66-69
    • /
    • 2014
  • The spreading tube of X-ray cathode tube displayed with an electromagnetic finite element method was designed. To analyze a feature design and the concrete coordinate performance of soft X-ray tube modeling, the orbit of electron beam was simulated by OPERA-3D SW program. The fixed conditions were the applied voltage, the temperature, the work function of thermal electron between cathode and anode of tungsten. Through the analysis of distribution of electron beam and the variation of dividing region, the design of soft X-ray spreading tube equipped with two cross filaments was optimized.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

A Study on the Thermal Properties of Glass for Effective Salvage Process of Flat Cathode-ray Tube (평면 음극선관의 재생률 향상을 위한 유리재료의 열적 특성에 관한 연구)

  • Park, Sang-Hu;Lee, Bu-Yun;Kim, Won-Jin;Heo, Bo-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.1988-1994
    • /
    • 2001
  • The CRT(Cathode-ray Tube) of salvage is a process of separating the panel and funnel to recycle a cathode-ray tube. In this paper, the thermal properties of glass for CRT were studied to improve its recycling ratio. In the salvage process, several patterns of breakage, as called 'comer pull', were easily generated on the sealing surface of panel or funnel glass due to the residual tensile stress, which had correlations with some parameters of the manufacturing process of CRT and the initial material properties of glass. Finite element analyses and experimental approaches on the flit sealing process were carried out to obtain the major characteristic of glass related to the residual stress. From this study, it was identified that the thermal expansion coefficient of glass had much influence on the residual stress of panel glass after frit sealing process. Therefore, the optimal conditions of thermal properties for CRT glass were proposed to achieve an effective salvage process. By using these optimal conditions, the size of comer pull on the panel and funnel glass was reduced to 10% level compared with the original size, and the recycling ratio of CRT was increased in the salvage process.

Structural Design of a Cathode-ray Tube (CRT) to Improve its Mechanical Shockproof Character

  • Park, Sang-Hu;Kim, Won-Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.9
    • /
    • pp.1361-1370
    • /
    • 2006
  • An electronic beam mis-landing phenomenon on the RGB (red/green/blue) -fluorescent surface has been considered as one of serious problems to be solved in cathode-ray tube (CRT), which is generally caused by mechanical shock and vibration. In this work, structural design concepts on the major parts of the CRT, such as a frame, a shadow mask, and a spring, are studied to improve the mechanical shockproof character of a CRT by FEM-analyses and experimental approaches ; a frame is newly designed to have strength employing the double-corner-beads which reduces considerably the distortion of the frame and the shadow mask : the edge-bead of a shadow-mask is redesigned to maintain the wide curved surface of a shadow-mask after mechanical shock : finally, a spring supporting the frame and the shadow-mask is designed to have enough flexibility along drop-direction. As an example, a conventional type of a 15inch CRT was utilized to demonstrate the feasibility and usefulness of this work. Overall, some favorable information on the structural design of the CRT is achieved, and the mechanical shockproof character of a 15-inch CRT is improved in the degree of 3G $(1G=9.81m/s^2)$ as an average-value.

Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method (유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구)

  • Park, Tae-Young;Noh, Young-Il;Lee, Sang-Suk;Park, Rae-Jun;Kim, Ki-Seon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The focal spot of electron beam depending on the anode angle in the structure and major parts of the X-ray tube was investigated by the OPERA-3D/SCALAR simulation program. The simulation worked on four spaces with with two spaces, including anode and cathode of X-ray tube, by applying the finite element method analysis. The analytical model and dimension for the emission orbit of thermal electrons made from one filament of the focused X-ray cathode is affected to the penumbra of detector for the X-ray depending on any real focal spot size. The model shape of focusing cap and focusing tube with an anode target angle and a cathode filament is analyzed by the current density distribution of thermal electrons. The focusing width of thermal electrons for the X-ray tube depended on the anode angle (${\theta}$). The focusing value of electron beams at a region of anode angle having $10^{\circ}{\sim}17^{\circ}$ maintained to below value of $70{\mu}m$. The minimum focal size of the electron beam was $40{\mu}m$ at an anode angle of $15^{\circ}$. The focused X-ray tube of many variables depended on the thermionic emission of hot electrons from the target trajectory. The focusing tube will contribute to the real design of X-ray for the development of future diagnosis medical device.

Development of Registration Method of Panel and Mask for FTM Tube (FTM 튜브의 판넬과 마스크의 일치방법 개발)

  • Yun, Jong-Soon;Jung, Jong-Yun
    • IE interfaces
    • /
    • v.11 no.2
    • /
    • pp.107-117
    • /
    • 1998
  • This paper presents a useful method of registration in manufacturing of shadow color mask for cathode ray tubes of the FTM (Flat Tension Mask) type, wherein the shadow mask and front panel are interchangeable when mask-panels are assembled, which is called ICM system. Theoretical analysis and alignment process are presented. The pattern of mask aperture is registered with a screen pattern of corresponding geometry of the panel in flat tension mask tube. Registration accuracy of panel and mask affects the purity of color cathode ray tube concerned with mislanding. It tries to minimize the misregistration caused by variances, which are mechanical error, mask stretching position error, restrictive number of fiducial point, etc.

  • PDF