• Title/Summary/Keyword: catalytic reduction

Search Result 767, Processing Time 0.028 seconds

A Comparative Study on the NOx Removal Activities of Metal-ion-exchanged Mg/Cu-ZSM-5 Catalysts in the Treatment of Flue Gas from Stationary Sources (금속이온교환된 Mg/Cu-ZSM-5 촉매를 사용한 배연 탈질 공정에서 De-NOx활성 비교연구)

  • 김재천;이병용;정석진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.421-428
    • /
    • 1996
  • In this study, in order to make up its draw-back in Cu-ZSM-5 catalytic system, some of transition metals or alkaline earth metals were cocation-exchanged in Cu-ZSM-5. Among various cocation-ion-exchanged ZSM-5 catalysts, Mg/Cu-ZSM-5 has been found the most active and durable in NOx reduction even at high oxygen content as well as at the presence of water vapor. The role of Mg in ZSM-5 is supposed to prevent the dealumination of aluminum ions in super-cage even at harsh hydro-thermal conditions, and also it seems to stabilize the Cu ions in the structure. In order to prepare commercially available catalysts, Mg/Cu-ZSM-5 catalysts were wash-coated on the surface of honeycomb type monolith, and tested in terms of catalytic activities. As a result, it was found that the catalyst prepared bt the wash-coating showed satisfactorily high NOx conversion for the practical use in SCR process.

  • PDF

Site-directed Mutagenesis of Arginine 13 Residue in Human Glutathione S-Transferase P1-1

  • Koh, Jong-Uk;Cho, Hyun-Young;Kong, Kwang-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.772-776
    • /
    • 2007
  • In order to study the role of residue in the active site of glutathione S-transferase (GST), Arg13 residue in human GST P1-1 was replaced with alanine, lysine and leucine by site-directed mutagenesis to obtain mutants R13A, R13K and R13L. These three mutant enzymes were expressed in Escherichia coli and purified to electrophoretic homogeneity by affinity chromatography on immobilized GSH. Mutation of Arg13 into Ala caused a substantial reduction of the specific activity by 10-fold. Km GSH, Km DCNB and Km EPNP values of R13A were approximately 2-3 fold larger than those of the wild type. Mutation of Arg13 into Ala also significantly affected I50 values of S-methyl-GSH that compete with GSH and ethacrynic acid, an electrophilic substrate-like compound. These results appeared that the substitution of Arg13 with Ala resulted in significant structural change of the active site. Mutation of Arg13 into Leu reduced the catalytic activity by approximately 2-fold, whereas substitution by Lys scarcely affected the activity, indicating the significance of a positively charged residue at position 13. Therefore, arginine 13 participates in catalytic activity as mainly involved in the construction of the proper electrostatic field and conformation of the active site in human GST P1-1.

Preparation of Well-Dispersed Nanosilver in MIL-101(Cr) Using Double-Solvent Radiation Method for Catalysis

  • Chang, Shuquan;Liu, Chengcheng;Fu, Heliang;Li, Zheng;Wu, Xian;Feng, Jundong;Zhang, Haiqian
    • Nano
    • /
    • v.13 no.12
    • /
    • pp.1850145.1-1850145.8
    • /
    • 2018
  • In this study, a double-solvent radiation method is proposed to prepare silver nanoparticles in the pores of metal-organic framework MIL-101(Cr). The results reveal that well-dispersed silver nanoparticles with a diameter of about 2 nm were successfully fabricated in the cages of monodisperse octahedral MIL-101(Cr) with a particle size of about 400 nm. The structure of MIL-101(Cr) was not destroyed during the chemical treatment and irradiation. The resulting Ag/MIL-101 exhibits excellent catalytic performance for the reduction of 4-nitrophenol. This method can be extended to prepare other single or bimetallic components inside porous materials.

Effects of Organic and Inorganic Additives on Selective Non Catalytic Reduction Reaction of NOx in a Pilot Scale Flow Reactor (파일럿 규모의 흐름반응기에서 유기 및 무기 첨가제가 질소산화물의 선택적 무촉매 환원반응에 미치는 영향)

  • Park, Soo Youp;Yoo, Kyung Seun;Lee, Joong Kee;Park, Young Kwon
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.540-546
    • /
    • 2006
  • Effects of organic and inorganic additives on the SNCR reaction of NOx were investigated in a pilot scale flow reactor with a variation of operating parameters. NOx reduction efficiency increased with the increase of a residence time and an initial NOx concentration. NOx reduction reaction by urea solution started to appear about 850 and then reached to maximum value around $970^{\circ}C$. NOx reduction efficiency also increased with the increase of NSR (Normalized Stoichiometric Ratio) up to 2.0. Addition of ethanol and phenol as an organic additives shifted the optimum temperature window to lower region with decreasing the maximum NOx reduction efficiency. This might be due to the side reaction of hydrocarbon in ethanol structure. NaOH addition widened the temperature window and enhanced the NOx reduction efficiency about 10% due to the chain reaction of NaOH and the reduction of $N_2O$.

Numerical Study on Optimization of the SCR Process Design in Horizontal HRSG for NOx Reduction (수평형 폐열회수보일러 배기탈질 SCR시스템의 최적설계를 위한 수치해석적 연구)

  • Kim, Kyeongsook;Lee, Kyeongok
    • Journal of Environmental Science International
    • /
    • v.22 no.11
    • /
    • pp.1481-1498
    • /
    • 2013
  • The SCR (selective catalytic reduction) system is highly-effective technique for NOx reduction from exhaust gases. In this study, the effects of the direction and size of nozzle and the ammonia injection concentration on the performance of SCR system are analyzed by using the computational fluid dynamics method. When the nozzle is arranged in zigzaged direction which is normal to exhausted gas flow, it is shown that the uniformity of gas flow and the NH3/NO molar ratio is improved remarkably. With the change of the ammonia injection concentration from 0.2 vol%(wet) to 1.0 vol%(wet), the uniformity of gas flow shows a good results. As the size of nozzle diameter changes from 6 mm to 12 mm, the uniformity of gas flow is maintained well. It is shown that the uniformity of the $NH_3/NO$ molar ratio becomes better with decreasing the ammonia injection concentration and the size of nozzle diameter.

Ammonia flow control for NOx reduction in SCR system of refuse incineration plant (소각로의 NOx 제어용 SCR 시스템의 암모니아 공급량제어)

  • Kim, In-Gyu;Yeo, Tae-Gyeong;Kim, Hwan-Seong;Kim, Sang-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.451-457
    • /
    • 1998
  • This paper describes a modelling method for SCR(selective catalystic reduction) system in refuse incineration plant. We consider the SCR system as a single input and single output system. For modelling the SCR system, an auto regressive exogeneous(ARX) modelling method is used. In this case, we should design the white noise input for modelling and put it on the system as an input$(NH_3)$, and take an outlet NOx as an output. From these two relations, we design the ARX model with 45 second delay time and transform to a discrete system with sampling time of 0.5 second. Using the obtained SCR model, we verify that the outlet NOx is deeply related with stoker`s moving in boiler of refuse incineration plant.

Unified Modeling and Performance Prediction of Diesel $NO_x$ and PM Reduction by DOC-DPF-SCR System (DOC-DPF-SCR 시스템에 의한 디젤 배기 내 $NO_x$, 입자상 물질 저감 과정의 일관 모델링 및 성능 예측)

  • Jung, Seung-Chai;Yoon, Woong-Sup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.110-119
    • /
    • 2008
  • Computer methods with simplified mathematical models in conjunction with empirical model parameters can be efficiently practiced into an optimization of a diesel aftertreatment system. Components of prime interests are diesel particulate filter, diesel oxidation catalyst and de-$NO_x$ catalytic converter. de-$NO_x$, de-PM, and de-HC processes in each part are individually modeled, formulated and then combined into an integrated analysis procedure for a unified simulation of the diesel emission aftertreatment. The model is empirically tuned and validated with comprehensive engine and laboratory data. The effects of emission species and space velocity on the $NO_x$ and soot reductions are parametrically investigated. A lowered $NO_2/NO_x$ ratio due to PM oxidation in DPF contributes to promote the $NO_x$ reduction by SCR at intermediate gas temperatures. $NO_x$ reduction is inert to the PM oxidation at high temperatures. Rate of PM trapping strongly depends on temperature and $NO_x$ concentration.

Research on the NOx Reduction Rate of Diesel Vehicle for Euro-6 (Euro-6 대응 경유 차량의 NOx 저감율 분석 연구)

  • Kang, Minkyung;Kwon, Seokjoo;Seo, Youngho
    • Journal of Institute of Convergence Technology
    • /
    • v.7 no.1
    • /
    • pp.15-18
    • /
    • 2017
  • As emission gas regulation of deisel vehicles is strengthened to Euro-6, It becomes difficult to deal with NOx regulated value mainly by EGR without additional after-treatment system. In addition, RDE(Real Driving Emissions) test will be introduced after september 2017. Therefore, It is essential to develop the after-treatment of diesel vehicles which reduce NOx emissions. It is possible to use DOC, DPF, LNT or DOC, DPF and SCR as a after-treatment system for reducing NOx. However, It is expected that the SCR will be applied widely because LNT alone does not have sufficient NOx purification efficiency. In this study, It tried to analyze the efficiency of reducing NOx emissions during the mode test by attaching a NOx sensor to test vehicle. As a result, It was confirmed that NOx emissions was significantly reduce through the after-treatment system from engine. And the NOx reduction efficiency of SCR was about 4.5 times better than DOC, DPF.

A Study on the Improvement of Radiated Noise in SCR Muffler of Commercial Vehicle (상용차용 SCR 머플러의 방사소음 개선에 관한 연구)

  • Lee, Dong-Won;Kim, Wan-Su;Bae, Chul-Yong;Kim, Chan-Jung;Kwon, Sung-Jin;Lee, Bong-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.816-822
    • /
    • 2008
  • This study presents the design modification for SCR muffler of a commercial vehicle. Its main objective is the reduction of radiated noise at SCR muffler. For this study, the research of five steps were achieved by experimental and CAE analysis. First step is the measurement of radiated noise using impact-acoustic test. Second step is the source identification using experimental modal analysis. The cause of radiated noise source is confirmed by the resonance of end plates at SCR muffler. Third step confirms the possibility of resonance avoidance using SDM analysis applied the mass control. Fourth step is the suggestion of design modification which is the change of mode shape by CAE analysis. Last step is the verification of design modification using SYSNOISE analysis. Finally, the prototype product applied the countermeasure of resonance evasion was manufactured and the reduction of radiated noise at SCR muffler was confirmed by pass-by noise test.

Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol (복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과)

  • Kim, Ki-Youn;Kim, Chi-Nyon;Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.