• Title/Summary/Keyword: cast-in-concrete

Search Result 499, Processing Time 0.024 seconds

Strength prediction and correlation of concrete by partial replacement of fly ash & silica fume

  • Kanmalai C. Williams;R. Balamuralikrishnan
    • Advances in concrete construction
    • /
    • v.16 no.6
    • /
    • pp.317-325
    • /
    • 2023
  • Strength prediction and correlation of concrete is done using experimental and analytical methods. Main objective is to correlate the experimental and simulated values of compressive strength of concrete mix using Fly Ash (FA) and Silica Fume (SF) by partial replacement of cement in concrete. Mix proportion was determined using IS method for M40grade concrete. Hundred and forty-seven cubes were cast and tested using Universal Testing Machine (UTM). Genetic Algorithm (GA) model was developed using C++ program to simulate the compressive strength of concrete for various proportions of FA and SF replacements individually at 3% increments. Experiments reveal that 12 percent silica fume replacement produced maximum compressive strength of 35.5 N/mm2, 44.5 N/mm2 and 54.8 N/mm2 moreover 9 percent fly ash replacement produced a maximum strength of 31.9 N/mm2, 37.6 N/mm2 and 51.8 N/mm2 during individual material replacement of concrete mix. Correlation coefficient for each curing period of fly ash and silica fume replaced mix were acquired using trend lines. The correlation coefficient is found to be approximately 0.9 in FA and SF replaced mix irrespective of the mix proportion and age of concrete. A higher and positive correlation was found between the experimental and simulated values irrespective of the curing period in all the replacements.

An experimental and numerical approach in strength prediction of reclaimed rubber concrete

  • Williams, Kanmalai C.;Partheeban, P.
    • Advances in concrete construction
    • /
    • v.6 no.1
    • /
    • pp.87-102
    • /
    • 2018
  • Utilization of waste tires may be considered as one of the solution to the problems faced by the local authorities in disposing them. Reclaimed rubber (RR) is being used in concrete for replacing conventional aggregates. This research work is focused on the strength prediction of reclaimed rubber concrete using a Genetic Algorithm (GA) for M40 grade of concrete and comparing it with experimental results. 1000 sets were taken and 100 iterations were run during training of GA models. A base study has been carried out in this research work partially replacing cement with three types of fillers such as Plaster of Paris (POP), Fly Ash (FA) and Silica Fume (SF). A total of 243 cubes were cast and tested for compression using a Universal Testing Machine. It was found that SF produced maximum strength in concrete and was used in the main study with reclaimed rubber. Tests were conducted on 81 cube samples with a combination of optimum SF percent and various proportions of RR replacing coarse aggregates in concrete mix. Compressive strength tests of concrete at 7, 14 and 28 days reveal that the maximum strength is obtained at 12 percent replacement of cement and 9 percent replacement of coarse aggregates respectively. Moreover the GA results were found to be in line with the experimental results obtained.

Experimental and numerical study of headed bars embedded in RC members under tension

  • Santana, Paulo F.M.;Silva, Patricia C.S.;Ferreira, Mauricio P.;Bezerra, Luciano M.;Oliveira, Marcos H.
    • Structural Engineering and Mechanics
    • /
    • v.84 no.4
    • /
    • pp.531-546
    • /
    • 2022
  • Headed bars are often used when there is insufficient space for a straight or curved bar to be fully developed to ensure the transference of forces between steel and concrete in several types of connections between structural members. In such cases, the concrete breakout strength of the headed bars can be a critical point of the design and must be considered appropriately. This paper evaluates the tensile strength of headed bars embedded in reinforced concrete members, failing due to concrete breakout. Four experimental tests on headed bars embedded in slender concrete members are presented and discussed, showing that strength previsions from the design codes can be significantly conservative as they ignore the contribution from the flexural reinforcement. 3D finite element models were developed using Abaqus Unified FEA to simulate the tested specimens, and it was observed that they were able to reproduce the formation of the concrete cone accurately, besides the response and resistance observed in tests. Furthermore, the experimental, numerical, and design code resistances are compared and discussed. A new equation to evaluate the concrete cone strength of the tested headed bars is proposed, which takes into account parameters not explicitly considered in the current design equations.

Precast concrete slab track - state of the art (프리캐스트 콘크리트 슬래브궤도 기술현황)

  • Jang Seung Yup;Yang Sin Chu;Kim Jeong Il;Kim Tae Wook
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.104-110
    • /
    • 2003
  • Precast concrete slab track has been already turned out to be more efficient than cast-in place concrete slab track in view of the easiness of construction and the quality control of concrete. Thus, there is a great need to bring in the precast slab track system. In order to develop the realistic precast slab track system that is well conformed to our circumstances, the performance criteria of slab track, and the state-of-the art of precast slab track systems that are used in other countries are briefly discussed here.

  • PDF

Adhesion Performance Change of Positive-side Installed Rubber Asphalt Waterproof Sheet Integrated with Water-Soluble Film in Accordance to Wetness Condition (수용성 필름이 일체화된 역타설 고무 아스팔트 방수시트의 콘크리트 타설시 가수 여부에 따른 부착성능 변화 연구)

  • An, Ki-Won;Kang, Hyo-Jin;Kim, Chun-Hag;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.229-230
    • /
    • 2019
  • Integrated water-soluble film is dissolved in the rubber asphalt waterproof sheet to secure adhesive strength on freshly cast concrete on the adhesion side of waterproofing layer on the floor slab. In addition, in order to determine whether the water in the concrete slurry can dissolve the water-soluble film sufficiently, the adhesive strength of the waterproofing sheet was compared between difference wetness condition at the upper part of the concrete specimen before the concrete casting.

  • PDF

Test study of precast SRC column under combined compression and shear loading

  • Chen, Yang;Zhu, Lanqi;Yang, Yong
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.265-275
    • /
    • 2022
  • A new type of precast steel reinforced concrete (PSRC) column was put forward in this paper. In order to study the static performance of PSRC column and hollow precast steel reinforced concrete (HPSRC) column subjected to combined compression and shear loading, a parametric test was carried out and effects of axial compression ratio, concrete strength and shear ratio on the mechanical behavior of composite PSRC column and HPSRC column were explored. In addition, the cracks development, load-span displacement relationship, strain distribution and shear bearing strength of column specimens were emphatically focused. Test results implied that shear failure of all specimens occurred during the test, and higher strength of cast-in-place concrete, smaller shear ratio and larger axial compression ratio could lead to greater shear resistance, but when the axial compression ratio was larger than 0.36, the shear capacity began to decrease gradually. Furthermore, truss-arch model for determining the shear strength of PSRC column and HPSRC column was proposed and the calculated results obtained from proposed method were verified to be valid.

Design of Vam Cong Cable Stayed Bridge in Vietnam (베트남 밤콩 사장교의 설계)

  • Lee, Yong-Jin;Kang, Jeong-Woon;Bae, Sang-Woon;Yun, Yeon-Suk;Lho, Byeong-Cheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.120-127
    • /
    • 2013
  • Vam Cong Cable Stayed Bridge which has 450m main span length is one of the Central Mekong Delta Region Connectivity Project and is located in Cuu Long Delta Region. It has steel-concrete composite girder with 4 lane and the type of cable is multi strand cable. The improved H-shape pylon and cast-in-place bored piles were applied. High strength concrete is applied for pylon, precast concrete slab and Cast-in-Situ concrete pile to ensure the structural safety. The present paper describe the design specifications and main features of Vam Cong Cable Stayed Bridge design.

Flexural behavior of prestressed hybrid wide flange beams with hollowed steel webs

  • Han, Sun-Jin;Joo, Hyo-Eun;Choi, Seung-Ho;Heo, Inwook;Kim, Kang Su
    • Steel and Composite Structures
    • /
    • v.38 no.6
    • /
    • pp.691-703
    • /
    • 2021
  • In this study, experiments were conducted to evaluate the flexural performance of prestressed hybrid wide flange (PHWF) beams with hollowed steel webs. A total of four PHWF beams were fabricated, where the width and spacing of the steel webs and the presence of cast-in-place (CIP) concrete were set as the main test parameters, and their flexural behavior and crack patterns, and the longitudinal strain distribution in a section with respect to the width and spacing of the steel webs were analyzed in detail. The experiment results showed that, as the ratio of the width to the spacing of the steel webs decreased, the flexural stiffness and strength of the PHWF beams without CIP concrete decreased. In addition, in the case of composite PHWF beam with CIP concrete, fully composite behavior between the precast concrete and the CIP concrete was achieved through the embedded steel member. Finite element analyses were performed for the PHWF beams considering the bond properties between the hollowed steel webs and concrete, and nonlinear flexural analyses were also conducted reflecting the pre-compressive strains introduced only into the bottom flange. From the comparison of the test and analysis results, it was confirmed that the analysis models proposed in this study well evaluated the flexural behavior of PHWF beams with and without CIP concrete.

Experimental Observation of Double Composite Box Girders subjected to Concrete Creep and Shrinkage (이중합성 박스 거더의 재령종속적 거동실험 및 해석)

  • 강병수;김정현;곽동석;홍인택;이용학
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.169-172
    • /
    • 2003
  • Time dependent deflections of double composite box girders are investigated based on the on going laboratory experiments scheduled for 3months long. Two of 2-span double composite box girders with 2.5m each span length are cast and time dependent behaviors are measured using 30 strain gages and 2 LVDTs after 5 days' curing. The measured experimental results are compared with the numerical predictions performed based on the one dimensional finite element method adopting beam element. The FEM formulation adopts the time dependent concrete constitutive model which is derived in an incremental format by expanding the total form of stress-strain relation by the first order Taylor series with respect to the reference time. A good agreement between the measured and predicted results are observed and the effects of the bottom concrete placed at the negative moment region of the bridge girder are discussed.

  • PDF

Nondestructive Evaluation of Concrete Strength Considering Aging Effect (재령을 고려한 콘크리트의 비파괴강도평가)

  • Kim, Young-Jin;Lee, Sang-Min;Choi, Hong-Shik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.157-165
    • /
    • 1999
  • The nondestructive testing methods are commonly used to determine the in-situ compressive strength of concrete. The correlation curves to evaluate the effect of aging on the development of concrete strength was proposed. Thirty two ${\Phi}10{\times}20cm$ cylinder specimens were cast from 5 batches having different strength levels. The correlation curves for rebound hammer method, ultrasonic pulse velocity method and combined method were derived from the laboratory tests and multiple regression analysis. To account for the change of condition such as surface hardness, internal moisture contents, the aging coefficients are applied to the correlation curves. From the comparison the nondestructive strength with the core strength taken from the existing reinforced concrete structures, the validity of the proposed correlation curves are verified.

  • PDF