• Title/Summary/Keyword: cascade estimation

Search Result 45, Processing Time 0.02 seconds

Fast Transcoding from H.264 to MPEG-4 (H.264에서 MPEG-4로 빠른 트랜스코딩)

  • 권혁균;이영렬
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.6
    • /
    • pp.91-99
    • /
    • 2004
  • This paper proposed two transcodiing methods, which maintain the same spatio-temporal resolution and reduce a spatial resolution, to convert a H.264 video bitstream into an MPEG-4 video bitstream. When the H.264 video bitstream is transformed into the MPEG-4 video bitstream, the conversions between H.264 block types and MPEG-4 block types are performed by minimizing distortion and the ${\times}4$ block-based motion vector mapping is performed. The proposed two transcoding methods run 4.14~5.1 times as fast as the cascaded transcoding methods in MPEG-4 encoder side, while the PSNR (peak-signal-to ratio) is slightly degrade with maximum 0.3dB.

Estimation of Reduction Rate in Coastal Sediment Discharge by Dam Construction (댐 건설로 인한 해안 유입 토사 감소율의 산정)

  • Lee, Sahong;Bae, Soen Han;Lee, Jung Lyul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.194-200
    • /
    • 2015
  • 본 연구에서는 하천부터 하구까지의 댐 구조물 건설로 인해 해안으로의 표사 공급원이 감소하는 것을 정량적으로 검토하였다. 내륙과 해양의 전이역인 연안은 농수산업, 임해산업단지, 발전소 및 항만과 같은 산업 인프라, 관광 및 레크리에이션 등의 다양한 편익을 제공하여 높은 경제 사회 환경적 가치가 있다. 그러나 80년대 이후 무분별하게 추진되어온 각종 연안 개발은 직 간접적인 해안의 침식문제를 발생시켰다. 우리나라 서해의 경우 하천으로부터의 토사 유입 차단은 심각한 수준이다. 아직 그 영향이 해안으로 완전히 파급되지 못하여 그로 인한 장기 해안 침식이 두드러지지 않고 있으나 고파랑에 의한 빈번한 침식과 저질의 세립화 현상을 통하여 현재 진행형임을 알 수 있다. 그러나 일단 피해가 심각해지기 시작하면 돌이킬 수 없는 재앙이 될 측면도 많다. 따라서 우리나라 유역의 개발과 수리구조물 건설 현황을 살펴 이로 인한 해안 침식 결과가 얼마나 심각할 수 있는 지를 살펴본다. 본 연구에서는 수리구조물로 인한 토사량 감소 중 가장 주요한 토사 공급원 감소 원인인 댐으로 인한 토사량 감소율에 대한 연구를 진행한다. 먼저 각 댐의 건설 전, 유역면적당 토사량과 댐 건설 후, 해안 유입 토사량 사이에 감소율을 계산하고, cascade 방법에 의하여 댐군에 의한 토사감소율을 산정한다. 유입 토사량 감소율을 산정하고 토사 공급원 감소로 인한 표사 수지 분석을 통해 해안 침식 폭의 위험도 평가를 실시한다.

  • PDF

A Realization of Real Time Algorithm for Fault and Health Diagnosis of Turbofan Engine Components (터보팬엔진의 실시간 구성품 결함 및 건전성 진단 알고리즘 구현)

  • Han, Dong-Ju;Kim, Sang-Jo;Lee, Soo-Chang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.10
    • /
    • pp.717-727
    • /
    • 2022
  • An algorithm is realized for estimating the component fault and health diagnosis such as a deterioration. Based on the turbofan engine health diagnosis model, from the health parameters which are estimated by a real time tracking filter, the outliers are eliminated efficiently by an effective median filter to minimize an false alarm. The difference between the fault and deterioration trends is identified by the detection measure for abrupt change, thereby the clear diagnosis classifying the fault and the health condition is possible. The effectiveness of the algorithm for fault and health diagnosis is verified from the simulated results of engine component faults and deterioration.

Characteristics of Ambient Metals: Size Segregated Ambient Concentrations and Dry Deposition Fluxes at Four Sites in Kunpo in 2000

  • Kim, Yong-Pyo;Yun, Hui-Jung;Yi, Seung-Muk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.57-68
    • /
    • 2002
  • Atmospheric dry deposition fluxes and size segregated concentrations of particulate metal elements were measured at four sites in Kunpo, a small city in the Seoul metropolitan area in Korea. At each site, aerosol samples were collected by dry deposition plates, a cascade impactor, and a coarse panicle rotary impactor during four sampling periods. At all sites, the average fluxes of metals measured during daytime were higher than nighttime fluxes due to higher wind speeds and higher ambient concentrations during daytime. The average fluxes of crustal elements (Al, Ca) were 1∼2 orders of magnitude higher than anthropogenic elements (As, Cd, Cu, Mn, Ni, Pb, and Zn). The daytime fluxes of Al and Ca were between 90 and 12000 $\mu\textrm{g}$ m$\^$-2/ day$\^$-1/, and the nighttime fluxes of Al and Ca were between 20 and 2200 $\mu\textrm{g}$ m$\^$-2/ day$\^$-1/. The daytime fluxes of Pb, a typical anthropogenic element, were between 20 and 160$\mu\textrm{g}$ m$\^$-2/ day$\^$-1/, and the nighttime fluxes of Pb were between ND and 100$\mu\textrm{g}$ m$\^$-2/ day$\^$-1/. Also the ambient metal concentrations during daytime were higher than nighttime. Based on a dust emission estimation study in Kunpo, it was found that dust emissions during daytime are higher than nighttime. The concentrations of crustal elements were higher than anthropogenic elements. The distributions of heavy metals were mainly in small particles (D$\_$p/ 9㎛). The fraction of crustal elements in the large particles (D$\_$p/> 9㎛) were higher than anthropogenic elements.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.