• Title/Summary/Keyword: carrier state

Search Result 428, Processing Time 0.037 seconds

Decrease of Distribution Volume of a Basic Drug in Rats of Experimental Renal Failure (신장해에 의한 염기성약물의 분포용적감소예와 그 기전)

  • 심창구
    • YAKHAK HOEJI
    • /
    • v.27 no.1
    • /
    • pp.21-28
    • /
    • 1983
  • Distribution volume (Vd$_{ss}$ ) of a model basic drug, tetraethylammonium bromide (TEA) at a steady-state decreased sinificantly in glycerol and uranium-renal failure rats. Assuming carrier-mediated transport of TEA into tissues, the theoretical $Vd_{ss}$ of TEA decreases in an exponential way as the plasmal concentration of TEA increases. The relationship between $Vd_{ss}$ and plasma concentration of TEA in the experimental renal failure (ERF)-rats was similar. Therefore, the decrease in $Vd_{ss}$ of TEA in the ERF-rats seemed to be due to the saturation of the carrier system that are responsible for the tissue distribution of TEA, by the elevated plasma concentration of TEA in the ERF-rats. ERF was induced to rats with glycerol, folate, salicylate, uranium and gentamicin, respectively..

  • PDF

A study on the Conducted Noise Reduction in Three-Phase Boost Converter using Random Pulse Width Modulation (Random PWM 기법을 이용한 3상 승압형 컨버터 전도노이즈 저감에 관한 연구)

  • Jung, Dong-Hyo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.3
    • /
    • pp.120-125
    • /
    • 2002
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. Generally, to reduce the EMI and improve the immunity of converter system, the switching frequency of converter needs to be properly modulated during a rectified line period instead of being kept constant. Random Pulse Width Modulation (RPWM) is performed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300V/1kW with 5%~30% white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

High-Speed Access over Copper: Rate Optimization and Signal Construction

  • Enteshari, Ali;Fadlullah, Jarir M.;Kavehrad, Mohsen
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.489-499
    • /
    • 2009
  • This paper focuses on assessment and design of transmission systems for distribution of digital signals over standard Category-7A copper cables at speeds beyond 10 Gbps. The main contribution of this paper is on the technical feasibility and system design for data rates of 40 Gbps and 100 Gbps over copper. Based on capacity analysis and rate optimization algorithms, system parameters are obtained and the design implementation trade-offs are discussed. Our simulation results confirm that with the aid of a decision-feedback equalizer and powerful coding techniques, namely, TCM or LDPC code, 40 Gbps transmission is feasible over 50 m of CAT-7A copper cable. These results also indicate that 100 Gbps transmission can be achieved over 15 m cables.

Analysis and Degradation of leakage Current in submicron Device (미세소자에서 누설전류의 분석과 열화)

  • 배지철;이용재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.113-116
    • /
    • 1996
  • The drain current of the MOSFET in the off state(i.e., Id when Vgs=0V) is undesired but nevertheless important leakage current device parameter in many digital CMOS IC applications (including DRAMs, SRAMs, dynamic logic circuits, and portable systems). The standby power consumed by devices in the off state have added to the total power consumed by the IC, increasing heat dissipation problems in the chip. In this paper, hot-carrier-induced degra- dation and gate-induced-drain-leakage curr- ent under worse case in P-MOSFET\`s have been studied. First of all, the degradation of gate-induced- drain-leakage current due to electron/hole trapping and surface electric field in off state MOSFET\`s which has appeared as an additional constraint in scaling down p-MOSFET\`s. The GIDL current in p-MOSFET\`s was decreased by hot-electron stressing, because the trapped charge were decreased surface-electric-field. But the GIDL current in n-MOS77T\`s under worse case was increased.

  • PDF

Residual Synchronization Error Elimination in OFDM Baseband Receivers

  • Hu, Xingbo;Huang, Yumei;Hong, Zhiliang
    • ETRI Journal
    • /
    • v.29 no.5
    • /
    • pp.596-606
    • /
    • 2007
  • It is well known that an OFDM receiver is vulnerable to synchronization errors. Despite fine estimations used in the initial acquisition, there are still residual synchronization errors. Though these errors are very small, they severely degrade the bit error rate (BER) performance. In this paper, we propose a residual error elimination scheme for the digital OFDM baseband receiver aiming to improve the overall BER performance. Three improvements on existing schemes are made: a pilot-aided recursive algorithm for joint estimation of the residual carrier frequency and sampling time offsets; a delay-based timing error correction technique, which smoothly adjusts the incoming data stream without resampling disturbance; and a decision-directed channel gain update algorithm based on recursive least-squares criterion, which offers faster convergence and smaller error than the least-mean-squares algorithms. Simulation results show that the proposed scheme works well in the multipath channel, and its performance is close to that of an OFDM system with perfect synchronization parameters.

  • PDF

Leg-Balancing Control of the DC-link Voltage for Modular Multilevel Converters

  • Du, Sixing;Liu, Jinjun;Lin, Jiliang
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.739-747
    • /
    • 2012
  • This paper applies carrier phase shifted pulse-width modulation (CPS-PWM) to transformerless modular multilevel converters (MMC) to improve the output spectrum. Because the MMC topology is characterized by the double-star connection of six legs consisting of cascaded modular chopper cells with floating capacitors, the balance control of the DC-link capacitor voltage is essential for safe operation. This paper presents a leg-balancing control strategy to achieve DC-link voltage balance under all operating conditions. This strategy based on circulating current decoupling control focused on DC-link balancing between the upper and lower legs in each phase pair by considering the six legs as three independent phase-pairs. Experiments are implemented on a 100-V 3-kVA downscaled prototype. The experimental results show that the proposed leg-balancing control is both effective and practical.

Charge Transfer Mechanism of Electrically Bistable Switching Devices based on Polyimide

  • Lee, Gyeong-Jae;Im, Gyu-Uk;Kim, Dong-Min;Lee, Mun-Ho;Gang, Tae-Hui;Jeong, Seok-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.374-374
    • /
    • 2010
  • Charge transfer mechanism of poly(4,4'-aminotriphenylene hexafluoroisopropylidenediphthalimide) (TP6F PI) which exhibits bistable ON and OFF switching has been studied using photoemission electron spectroscopy (PES) and near-edge x-ray absorption fine structure (NEXAFS). Here, we demonstrate novel set-up in which holes are injected by photoemission process instead of direct charge carrier injection via metal electrode. The accumulated charges on the PI surface in the OFF state abruptly flow across the PI film when the bias voltage of a back electrode reaches a specific value, indicating that the film is changed to the ON state. Core level and x-ray absorption spectra probed at charge injection region via photoemission process do not show any evidences implying structural modification of TP6F PI during the phase change. Whereas, in valence band spectra, the highest occupied molecular orbital (HOMO) is shifted toward Fermi level, responsible for improved hole-mobility of TP6F PI of ON state.

  • PDF

The Measurement of 3-Phase Current with Single Current Sensor and the Compensation of Voltage Distortion in Carrier-Based PWM Technique (삼각파 비교 PWM 기법에 있어서 단일 전류센서에 의한 삼상 전류 측정 및 전압 왜곡 보상)

  • 김경서
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.292-298
    • /
    • 2003
  • Most of the three phase inverters for adjustable speed drive of AC machines are equipped with two or three current sensors for measurement of three phase current. One method to reduce the number of current sensors is that single current sensor measures the DC link current, then three phase current is reconstructed using the measured value and the switching status. To improve the measurement accuracy, switching state should be maintained for more than minimum switching time. Many papers have been published, which focused on the readjustment of pulse width and compensation of voltage distortion. Those methods are suitable for space vector modulation. But there are some difficulties in applying these methods to carrier-based PWM which is widely used in industry. In this paper, new current measurement method and voltage compensation method are proposed which are suitable for carrier-based PWM, then, the validity of proposed method is confirmed through experiment.

A Carrier-Rotation Strategy for Voltage Balancing of Flying Capacitors in Flying Capacitor Multi-level Inverter (플라잉 커패시터 멀티-레벨 인버터의 플라잉 커패시터 전압 균형을 위한 캐리어 로테이션 기법)

  • 이원교;김태진;강대욱;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.469-477
    • /
    • 2003
  • This paper proposes a Carrier-Rotation (CR) PWM technique that is a new solution for the voltage unbalancing problem of flying capacitors in the Flying Capacitor Multi-level Inverter (FCMI). The proposed technique equalizes the utilization of phase leg voltage redundancies corresponding to the charging and the discharging state of individual flying capacitors during each switching period of all the switches. Therefore, the charging and the discharging quantity of flying capacitors are equal, which makes the average variation of flying capacitor voltages become zero and keeps their voltage stable during minimum specified period. It also has the reduced harmonic contents of output voltage and the same switch utilization since all the carrier signals are in phase and the switching frequency of each switch is identical. The proposed technique is analyzed precisely in flying capacitor 3-level inverter and then it has expanded to the FCMI (N-level, N>3). Experimental results on the laboratory prototype flying capacitor 3-level inverter confirm the validity of the proposed technique.

Resilient Reduced-State Resource Reservation

  • Csaszar Andras;Takacs Attila;Szabo Robert;Henk Tamas
    • Journal of Communications and Networks
    • /
    • v.7 no.4
    • /
    • pp.509-524
    • /
    • 2005
  • Due to the strict requirements of emerging applications, per-flow admission control is gaining increasing importance. One way to implement per-flow admission control is using an on­path resource reservation protocol, where the admission decision is made hop-by-hop after a new flow request arrives at the network boundary. The next-steps in signaling (NSIS) working group of the Internet engineering task force (IETF) is standardising such an on-path signaling protocol. One of the reservation methods considered by NSIS is reduced-state mode, which, suiting the differentiated service (DiffServ) concept, only allows per-class states in interior nodes of a domain. Although there are clear benefits of not dealing with per-flow states in interior nodes-like scalability and low complexity-, without per-flow states the handling of re-routed flows, e.g., after a failure, is a demanding and highly non-trivial task. To be applied in carrier-grade networks, the protocol needs to be resilient in this situation. In this article, we will explain the consequences of a route failover to resource reservation protocols: Severe congestion and incorrect admission decisions due to outdated reservation states. We will set requirements that handling solutions need to fulfill, and we propose extensions to reduced-state protocols accordingly. We show with a set of simulated scenarios that with the given solutions reduced-state protocols can handle re-routed flows practically as fast and robust as stateful protocols.