• Title/Summary/Keyword: cardiovascular monitoring

Search Result 185, Processing Time 0.029 seconds

A Review of Anesthesia for Lung Transplantation

  • Kim, Hye-Jin;Shin, Sang-Wook;Park, Seyeon;Kim, Hee Young
    • Journal of Chest Surgery
    • /
    • v.55 no.4
    • /
    • pp.293-300
    • /
    • 2022
  • Lung transplantation is the only treatment option for patients with end-stage lung disease. Although more than 4,000 lung transplants are performed every year worldwide, the standardized protocols contain no guidelines for monitoring during lung transplantation. Specific anesthetic concerns are associated with lung transplantation, especially during critical periods, including anesthesia induction, the initiation of positive pressure ventilation, the establishment and maintenance of one-lung ventilation, pulmonary artery clamping, pulmonary artery unclamping, and reperfusion of the transplanted lung. Anesthetic management according to the special risks associated with a patient's existing lung disease and surgical stage is the most important factor. Successful anesthesia in lung transplantation can improve hemodynamic stability, oxygenation, ventilation, and outcomes. Therefore, anesthesiologists must have expertise in transesophageal echocardiography, extracorporeal life support, and cardiopulmonary anesthesia and understand the pathophysiology of end-stage lung disease and the drugs administered. In addition, communication among anesthesiologists, surgeons, and perfusionists during surgery is important to achieve optimal patient results.

Accurate Evaluation and Treatment of Dyspnea in Patients with Gastrointestinal Cancer (소화기 암환자 호흡곤란의 정확한 평가와 치료)

  • Jong Yoon Lee
    • Journal of Digestive Cancer Research
    • /
    • v.11 no.2
    • /
    • pp.108-113
    • /
    • 2023
  • Dyspnea is a common symptom among patients with gastrointestinal cancer, and a comprehensive evaluation of their respiratory function is essential. Self-reporting aids in the assessment of the degree of dyspnea, while objective examination methods are performed to identify the potential underlying causes when subjective symptoms are present. Standard treatment protocols should be followed for potentially reversible and common causes of dyspnea, such as pleural effusion, pneumonia, airway obstruction, anemia, asthma, exacerbation of chronic obstructive pulmonary disease, pulmonary thromboembolism, or drug-induced interstitial lung disease. Careful and close monitoring is required due to the high frequency of pulmonary thromboembolism and the risk of cardiovascular accidents, drug-induced interstitial lung disease, or other complications from some anticancer drugs. In case of hypoxemia with an oxygen saturation of 90% or less, palliative treatment should comprise standard oxygen therapy such as nasal cannula, mask, or high-flow nasal cannula. If non-pharmacological oxygen therapy is not effective, pain control through systemic narcotic analgesics and anti-anxiety therapy with benzodiazepines may be helpful.

Significance of Microembolic Signals during Oxygen Inhalation in Patients with Prosthetic Mechanical Heart Valve (인공 기계 심장 판막 이식 환자에서 산소 흡입 중 미세색전 신호의 중요성)

  • 조수진;나찬영;이은일;민양기;권기한;이정주;백만종;오삼세;홍석근
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.50-55
    • /
    • 2004
  • Background: Transcranial Doppler ultrasonography (TCD) can detect microembolic signals (MES) in the patients with a potential embolic source. Clinical significance of MES has not been demonstrated in patients with prosthetic mechanical heart valves. We studied the correlation between cerebral thromboemoblic events after the mechanical heart valve surgery (MHVS) and residual MES during TCD monitoring with 100% oxygen inhalation in patients with mechanical heart valves. Material and Method: Twenty patients with previous cerebral thromboemoblic events after MHVS and a sex- and age-matched control group (n=30) were studied. TCD monitoring was performed from unilateral middle cerebral artery. After baseline monitoring for 20 minutes, 61 of oxygen was inspired for 40 minutes. Result: The site of valve and the duration after MHVS of the patients did not differ from those of controls. During baseline monitoring, there was no significant difference in MES prevalence or counts compared to controls. During oxygen inhalation, patients showed a higher MES prevalence (55%, 27.6%, p=0.045) and a more frequent MES counts (p=0.027) compared to controls. Conclusion: TCD monitoring with oxygen inhalation may be useful to differentiate clinically significant MES in patients with mechanical heart valve.

Effect of Magnesium Administration on Preventing Arrhythmias after Coronary Artery Bypass Graft (관상동맥 우회술 후 마그네슘 투여가 심 부정맥을 예방하는 효과)

  • Kim, Jun-Hyun;Song, Hyun;Kim, Yong-Hee;Lee, Eun-Sang;Lee, Jay-Won;Song, Myung-Kun
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.339-345
    • /
    • 1998
  • Arrhythmias are common after cardiac surgery and are multifactorial. Intravenous magnesium administration reduces the frequency of ventricular arrhythmias in patient with symptomatic heart failure or acute myocardial infarction. This study was designed to evaluate the role of magnesium in preventing PVCs(premature ventricular contractions) occurred frequently after coronary artery bypass graft(CABG). 50 consecutive patients were prospectively entered into a randomized trial to determine the efficacy of postoperative magnesium therapy on the incidence of cardiac arrhythmias after elective coronary artery bypass graft. The patients underwent coronary angiography, echocardiography, electrocardiography and clinical laboratory study preoperatively. Continuous electrocardiographic monitoring was done and magnesium level was checked 0, 3, 6, 12, 18, 24, 36, 48, 60 and 72 hours postoperatively. Study group of 25 patients were given 4g of magnesium continuously over the first 24 hours and then 2g/24hours from 25 to 72 hours. The clinical characteristics of both groups were similar(p<0.05). The preoperative mean serum magnesium concentration was similar in both study group, 1.59mg/dl and control group, 1.71mg/dl. The mean postoperative serum magnesium concentration in study group elevated significantly over postoperative 12hours through 36hours(p<0.05). The postoperative mean serum magnesium concentration in control group declined and remained significantly depressed over immediate postoperation through 72hours. The mean serum magnesium concentration was significantly greater in the study group compared with the control group over postoperative 3hours through 72hours(p<0.05). There was a significant decrease in the incidence of arrhythmias such as PVCs(p<0.01) which might jeopardize hemodynamics. There were no recognized adverse effects of magnesium Administration. In conclusion, prophylactic magnesium administration seems to lessen the incidence and severity of rrhythmias after coponary artery bypass graft.

  • PDF

Analysis of the Relationship between the Preoperative Pulmonary Artery Index and the Postoperative Cardiac Performance in Cyanotic Congenital Heart Disease. (폐혈류감소를 동반한 선천성 심장기형에서 술전 폐동맥발육과 조기 술후 혈역학적 변화와의 관계)

  • Han, Jae-Jin;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.601-608
    • /
    • 1989
  • We sought the relationship between the pulmonary artery development and cardiac performance from the analysis of the 36 cyanotic congenital heart disease patients [mainly TOF] who were operated and indwelled the pulmonary artery and left atrial pressure monitoring catheters for the postoperative care at the department of Thoracic and Cardiovascular Surgery SNUH in 1988. They were pre-evaluated of the pulmonary artery index from the cineangiographic films and post-operatively, calculated the cardiac index from the arterial and mixed venous blood gas and also measured the mean left atrial pressure and total inotropic supporting amount after operation. The post-operative cardiac indices were 3.46 * 1.03 1/min/M2 [immediate postoperative], 3.31 [ 1.08 [postoperative 6 hrs], 3.29 [ 1.01 [12 hrs], 3.54 * 1.02 [24 hrs], 3.92 * 1.14 [48 hrs], respectively. We divided the patients the group A and group B from the size of the pulmonary artery index, that is, group A was below 200 mm2/M2 and group B above 200 mm2/M2 of the pulmonary artery index. The cardiac indices and left atrial pressure between the group A and B were not different in the view of the statistical significance but the total post-operative inotropic amount of group A was more than group B and it was significant statistically. We concluded that the smaller the pulmonary artery index is, the more postoperative supportive treatment [for example, inotropics] for the enhancement of cardiac performance is needed, and indirectly, which means that the pulmonary artery index was correlated with the postoperative cardiac performance in cyanotic congenital heart disease.

  • PDF

Frequency of Inappropriate Metformin Use in Patients with Diabetes Mellitus (당뇨병환자에게 부적절하게 사용된 Metformin의 처방빈도 분석)

  • Sin, Hye-Yeon;Jung, Ki-Hwa
    • YAKHAK HOEJI
    • /
    • v.54 no.6
    • /
    • pp.455-460
    • /
    • 2010
  • We evaluated the inappropriateness of metformin use in patients with type 2 diabetes and chronic medical conditions to identify the frequency of the prescription metformin in violation of the food and drug administration (FDA) black box warning. We reviewed medical records of 307 outpatients who received metformin at endocrinology department in a hospital setting between January 1, 2005 and August 30, 2009. Of the 307 outpatients, 25 discontinued treatment of metformin due to elevated serum creatinine level (Scr${\geq}$1.5 mg/dl in male, Scr${\geq}$1.4 mg/dl in female), cancers, and/or liver disease. 5 were lost to follow-up. 89 (29.0%) of the patients had cardiovascular disease, 54.1% for hypertension, 9.8% for liver disease, and 60 (20.8%) for chronic kidney disease. 12 patients (3.9%) with chronic kidney disease and/or elevated serum creatinine level, and 1 patient (0.3%) with lactic acidosis were contraindicated to metformin use. Metformin should be avoided in 7 outpatients (2.3%) with active hepatitis and 1 patient (2.6%) with liver cirrhosis. Of the 307 outpatients, 13 (4.2%) patients who received metformin at the first visit and 16 (8.7%) patients who received metformin at the last visit violated to black box warning. 8 (2.6%) of the patients were in precautionary conditions to metformin use. Adjusted mean difference of serum creatinine was -0.16 mg/dl [95% CI: -0.22 to -0.11 (p<0.05)] and adjusted mean difference of alanine aminotransferase was 4.46 IU/l [95% CI: 2.47 to 6.44 (p<0.05)] between the first visit and the last visit. Critical number of elderly patients who are at the high risks of drug-disease and drug-laboratory interaction is exposed to the inappropriate metformin use in violation of black box warning. The periodic evaluation of metformin use and monitoring prescription through drug utility review (DUR) system is needed to improve patients' safety and to reduce adverse drug events.

Estimation on the Depth of Anesthesia using Linear and Nonlinear Analysis of HRV (HRV 신호의 선형 및 비선형 분석을 이용한 마취심도 평가)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Hye-Jin;Kim, Tae-Kyun;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.76-85
    • /
    • 2010
  • In general, anesthetic depth is evaluated by experience of anesthesiologist based on the changes of blood pressure and pulse rate. So it is difficult to guarantee the accuracy in evaluation of anesthetic depth. The efforts to develop the objective index for evaluation of anesthetic depth were continued but there was few progression in this area. Heart rate variability provides much information of autonomic activity of cardiovascular system and almost all anesthetics depress the autonomic activity. Novel monitoring system which can simply and exactly analyze the autonomic activity of cardiovascular system will provide important information for evaluation of anesthetic depth. We investigated the anesthetic depth as following 7 stages. These are pre-anesthesia, induction, skin incision, before extubation, after extubation, Post-anesthesia. In this study, temporal, frequency and chaos analysis method were used to analyze the HRV time series from electrocardiogram signal. There were NN10-NN50, mean, SDNN and RMS parameter in the temporal method. In the frequency method, there are LF and HF and LF/HF ratio, 1/f noise, alphal and alpha2 of DFA analysis parameter. In the chaos analysis, there are CD, entropy and LPE. Chaos analysis method was valuable to estimate the anesthetic depth compared with temporal and frequency method. Because human body was involved the choastic character.

Past Trends and Future Estimation of Annual Breast Cancer Incidence in Osaka, Japan

  • Toyoda, Yasuhiro;Tabuchi, Takahiro;Nakayama, Tomio;Hojo, Shigeyuki;Yoshioka, Setsuko;Maeura, Yoshiichi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2847-2852
    • /
    • 2016
  • Background: Although the breast cancer incidence rate in Japan is lower than in western countries, the age-specific rates have markedly increased in recent years, along with the problems of declining birth rate and an aging population. Materials and Methods: We examined past trends of age-specific breast cancer incidence using data from the Osaka Cancer Registry from 1976 to 2010, and estimated future trends until 2025 based on the changes observed and population dynamics using a log linear regression model. Results: The age-specific breast cancer incidence rate has increased consistently from the 1970s, and the rates have caught up with those of Japanese-Americans in the US. Assuming the increasing tendency of age-specific breast cancer incidence to be constant, the average annual incidence of breast cancer will increase 1.7-fold from 2006-2010 to 2021-2025. Furthermore, the number of patients aged 80 years should increase 3.4-fold. Conclusions: The medical demand for breast cancer care in Japan may increase explosively in the future, particularly among the elderly. We need to prepare for such a future increase in demand for care, although careful monitoring is needed to confirm these results.

A development of a multimodal patch-type probe for measuring blood flow and oxygen saturation in carotid artery (경동맥 혈류 속도 및 산소 포화도 측정을 위한 다중모드 패치형 프로브 개발)

  • Youn, Sangyeon;Lee, Kijoon;Kim, Jae Gwan;Hwang, Jae Youn
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2019
  • To protect the patient's internal organs when a patient with cardiovascular disease occurs, it is important to reduce the elapsed time by providing emergency medical services. Decisions for conducting cardiopulmonary resuscitation are mainly made using the carotid palpation method, which directs the pulse of the carotid artery, which can diagnose the patient's condition according to one's own subject and cause cerebral blood flow to be blocked by excessive pressure in the carotid due to the weaken cardiopulmonary function. In this study, we developed a multimodal patch-type probe based on multi-channel ultrasound Doppler pairs and oxygen saturation measurement modules which can monitor cardiopulmonary functions. From the in-vivo experiments, the developed probe can be utilized as a novel tool that can increase the survival rate of cardiovascular disease patients by objectively monitoring the cardiopulmonary function of the patient quantitatively and promptly in an emergency situation.

A Dilute-and-Shoot LC-MS/MS Method for Screening of 43 Cardiovascular Drugs in Human Urine

  • Pham, Thuy-Vy;Lee, Gunhee;Mai, Xuan-Lan;Le, Thi-Anh-Tuyet;Nguyen, Thi Ngoc Van;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • A simple, specific, and economical LC-MS/MS method was investigated for the screening of 43 prescribed antihypertensive and related drugs in human urine. The urine samples were simply prepared by diluting and mixing with internal standard before directly introduced to the LC-MS/MS system, which is fast, straightforward, and cost-effective. Fractional factorial, Box-Behnken, and I-optimal design were applied to screen and optimize the mass spectrometric and chromatographic factors. The analysis was carried out on a triple quadrupole mass spectrometer system utilizing multiple reaction monitoring with positive and negative electrospray ionization method. Chromatographic separation was performed on a Thermo Scientific Accucore RP-MS column (50 × 3.0 mm ID., 2.6 ㎛) using two separate gradient elution programs established with the same mobile phases. Chromatographic separation was performed within 12 min. The optimal method was validated based on FDA guideline. The results indicated that the assay was specific, reproducible, and sensitive with the limit of detection from 0.1 to 50.0 ㎍/L. The method was linear for all analytes with coefficient of determination ranging from 0.9870 to 0.9981. The intra-assay precision was from 1.44 to 19.87% and the inter-assay precision was between 2.69 and 18.54% with the recovery rate ranges from 84.54 to 119.78% for all drugs measured. All analytes in urine samples were stable for 24 h at 25℃, and for 2 weeks at -60℃. The developed method improves on currently existing methods by including larger number of cardiovascular medications and better sensitivity of 12 analytes.