• Title/Summary/Keyword: cardiac preservation

Search Result 52, Processing Time 0.024 seconds

An Experimental Hlodel of Isolated Lung Block for Evaluation of Pulmonary Preservation after Ischemial (허혈후 폐 보존효과를 측정하기 위한 폐장 분리관류 모형)

  • Sung, Sook-Whan;Lim, Cheong;Kim, Young-Tae;Park, Jong-Ho
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.573-579
    • /
    • 1997
  • During the last 30 years, major organ transplantation has become popular, even in Korea, such as kidney, liver, etc. After the successful clinical cardiac transplantation in Korea, many cases of cardiac transplantation are being performed in some centers. But lung transplantation has a lot of obstacles, especially'donor shortage and decreased tolerability of the lung to ischemia-reperfusion injury. Usually it was considered that the maximum safety margin of ischemic time in lung transplantation was about 4 to 6 hours. So, many investigators have tried to develop better preservation methods and experimental model for evaluation of effectiveness in those various methods. But most of those methods had several drawbacks in clinical and experimental settings. So we developed an easily-controllable, reliable, and inexpensive experimental model of isolated rabbit lung block. Using these model, we evaluated its effectiveness and reliability for the experiment of ischemia-reperfusion injury in lung transplantation.

  • PDF

Brain Death and Kidney Transplantation in Dogs (개의 뇌사와 신장이식)

  • 우흥명;권오경
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.358-362
    • /
    • 2001
  • Brain dead (BD) patients remain the largest source of solid organs for transplantation. BD has shown to decrease graft function and survival in rodent models. The aim of this study was to evaluate how brain death affects graft viability in the donor and kidney tolerance to cold preservation as assessed by survival in a canine transplantation. 13 Beagle dogs were used for the study. Brain death was induced by the sudden inflation of a subdural balloon catheter with continuous monitoring of arterial blood pressure and eletroencephalographic activity (n=3). Sixteen hours after conformation of brain death, kidney graft were retrieved (n=6). Non-BD donors served as controls (n=4). All kidneys were flushed with University of Wisconsin (UW) solution and preserved for 24 hours at 4$^{\circ}C$ before transplantation. Recipient survival rates, serum creatinine level were analyzed. Brain death induced the well-known Cushing reaction with a severe increase in blood pressure and tachycardia. Thereafter, cardiac function returned progressively to baseline within 8 hours and remained stable until the end of the experiment. All of dogs in both group transplanted were survived until 7 days (100%), and the kidneys showed functional early rejection at 8.3$\pm$0.5 days and 8.5$\pm$0.5 days after transplantation, in BD and allograft group, respectively. BD kidneys were functionally similar to control kidneys for 7 days after transplantated. Brain death has no deleterious effect on preservation injury and survival of dog kidney transplantation, although it induces changes in hemodynamic parameters. This study reveals that kidneys from BD donors do not exhibit more ischemia reperfusion injury, and support good early function and survival.

  • PDF

The Effect of Temperature of Cardioplegic Soultion on Myocardial Protection from Ischemia - Experimental Study using Isolated Rat Heart Perfusion Technique - (흰쥐의 적출된 심장에서 심정지액의 온도가 심근보호에 미치는 영향)

  • 김용한
    • Journal of Chest Surgery
    • /
    • v.25 no.2
    • /
    • pp.131-136
    • /
    • 1992
  • The effect of temperature of cardioplegic solution on myocardial preservation was studied using isolated rat heart perfusion technique. Twenty Sprague-Dawley rats, weighing 120~140gm, were pretreated with intraperitoneal injection of heparin sodium[300u/kg] and then the hearts were excised after cervical herniation 30 minutes later. The hearts were perfused in isolated working heart apparatus with oxygenated modified Tyrode solution at 37oC. After 10 minutes of non working heart perfusion, the hearts were subjected to arrest for 30 minutes by administration of 5cc cardioplegic solution at the temperature of 4oC [Group I ], 15oC [Group II], 25oC [Group III], 37oC[Group IV]. At the same time, the topical cooling of heart was performed using ice saline. After arrest, the hearts were reperfused by non working heart perfusion for 1 hour with modified Tyrode solution at 37oC. The CPK, GOT and LDH in reperfusate were measured at 5,20,40,60 minutes after start of reperfusion. With the values of those, we compared the effect of temperature of cardioplegic solution on myocardial preservation. The results were as follows; 1. The enzyme values in reperfusate were highest at 5 minute and after then declined. 2. At 5 minutes after reperfusion, the enzyme values in Group I were lower than those in other Groups. These results suggest that the cardioplegic solutions using for cardiac arrest and myocardial protection can be working better at 4oC than at any other temperature.

  • PDF

Myocardial Protective Effect of Adenosine in Ischemic Rat Heart (흰쥐의 허혈심장에서의 Adenosine의 심근 보호 효과에 관한 연구)

  • 박승규
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1090-1106
    • /
    • 1990
  • This study was undertaken to investigate whether adenosine administered during cardioplegic arrest could enhance myocardial protection and improve recovery of function after ischemia. Isolated Langendorff-perfused rat hearts were subjected to 40 minutes of normothermic [37oC] ischemia. Control hearts [n=10] received modified St. Thomas’ cardioplegic solution, and the remaining hearts received modified St. Thomas’ cardioplegic solution with either 20 \ulcornerM [n=10], 200 \ulcornerM [n=10] adenosine. After ischemia of 40 minutes and 30 minutes of reperfusion, left ventricular contractility was superior in all groups of adenosine-treated hearts compared with control hearts. Furthermore, there was a significant incremental increase in functional recovery with increasing dose of adenosine. Post-ischemic diastolic stiffness was significantly better in all adenosine groups compared with controls. No differences were noted in coronary flow or myocardial water content between adenosine-treated and control hearts. These data demonstrate that adenosine administered in these concentrations provides myocardial protection, preservation of myocardial ATP and creatine phosphokinase and improved post-ischemic functional hemodynamic recovery after normothermic ischemia, presumably metabolically by reducing depletion of adenosine triphosphate, inducing rapid cardiac arrest and enabling improved post-ischemic recovery.

  • PDF

A case report of giant right ventricular myxoma (거대 우심실 점액종 1례 보)

  • Park, Jae-Gil;Song, In-Seong;Lee, Hong-Gyun
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.470-475
    • /
    • 1983
  • Myxoma of the heart can now be successfully treated but the success is obviously dependent upon the correct diagnosis and treatment prior to development of catastrophic complications such as sudden death, embolism or cardiac failure. The right ventricular myxoma is very rare, and we treated successfully a case of giant right ventricular myxoma, sessile tumor originated from ventricular apex, weighed 175 gm. The tumor base was broad, about 3 cm x 3cm, and it was hardly adhesed to the tricuspid valvular structures, but could remove with the preservation of adequate residual ventricular chamber size and the maintenance of functional tricuspid valve anatomy. The postoperative course was excellent and uneventful.

  • PDF

Fermented ginseng, GBCK25, ameliorates hemodynamic function on experimentally induced myocardial injury

  • Aravinthan, Adithan;Antonisamy, Paulrayer;Kim, Bumseok;Kim, Nam Soo;Shin, Dong Gyu;Seo, Jeong Hun;Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • v.40 no.4
    • /
    • pp.462-465
    • /
    • 2016
  • In the present study, we investigated whether treatment with GBCK25 facilitated the recovery of hemodynamic parameters, left ventricle systolic pressure, left ventricular developed pressure, and electrocardiographic changes. GBCK25 significantly prevented the decrease in hemodynamic parameters and ameliorated the electrocardiographic abnormality. These results indicate that GBCK25 has distinct cardioprotective effects in rat heart.

A Study on the Manufacture of the Artificial Cardiac Tissue Valve (생체판의 제작 및 실험)

  • Kim, Hyoung-Mook;Song, Yo-Jun;Sohn, Kwang-Hyun
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.

Xenograft Failure of Pulmonary Valved Conduit Cross-linked with Glutaraldehyde or Not Cross-linked in a Pig to Goat Implantation Model

  • Kim, Dong Jin;Kim, Yong Jin;Kim, Woong-Han;Kim, Soo-Hwan
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.287-294
    • /
    • 2012
  • Background: Biologic valved grafts are important in cardiac surgery, and although several types of graft are currently available, most commercial xenografts tend to cause early disfiguration due to intimal proliferation and calcification. We studied the graft failure patterns on non-fixed and glutaraldehyde-fixed pulmonary xenograft in vivo animal experiment. Materials and Methods: Pulmonary valved conduits were obtained from the right ventricular outflow tract of eleven miniature pigs. The grafts were subjected to 2 different preservation methods; with or without glutaraldehyde fixation: glutaraldehyde fixation (n=7) and non-glutaraldehyde fixation (n=4). The processed explanted pulmonary valved grafts of miniature pig were then transplanted into eleven goats. Calcium quantization was achieved in all of the explanted xenograft, hemodynamic, histopathologic and radiologic evaluations were performed in the graft which the transplantation period was over 300 days (n=7). Results: Grafts treated with glutaraldehyde fixation had more calcification and conduit obstruction in mid-term period. Calcium deposition also appeared much higher in the glutaraldehyde treated graft compared to the non-glutaraldehyde treated graft (p<0.05). Conclusion: The present study suggests that xenografts prepared using glutaraldehyde fixation alone appeared to have severe calcification compared to the findings of non-glutaraldehyde treated xenografts and to be managed with proper anticalcification treatment and novel preservation methods. This experiment gives the useful basic chemical, histologic data of xenograft failure model with calcification for further animal study.

Lung Preservation Study for Above 20 Hours of LPDG Solution in Canine Lung Allotransplactation (폐이식 실험견에서 LPDG용액을 이용한 20시간 이상 폐보존효과 관찰)

  • Park, Chang-Gwon;Gwon, Geon-Yeong;Yu, Yeong-Seon
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.949-960
    • /
    • 1997
  • Background. Limited ischemic tolerance of the lung has remained one of the factors that limits the expansion of pulmonary transplantation as a treatment for end-stage pulmonary disease. Numerous studies on safe long term preservation for lung transplantation has been performed for the purpose of developing ideal preservation solution with extracellular type or intracellular type solutions. In this. study, we examined the efficacy of L DG solution in lung preservation longer than 20 hours by comparison with modified Euro-Collins solution. Iwethods. Thirty-(our adult mongrel dogs were divided into two groups. Donor lungs were flushed with LPDG solution(n=9) or modified Euro-Collins(MEC) solution(n=8) and stored for 24 hours at 1$0^{\circ}C$. All donor lungs were perfused through the pulmonary arteries with solutions containing prostaglandin El and verapamil. Left canine lung allotransplantations wereperformed. Assessment(hemodynamic indices and arterial blood gas analysis) of left implanted lung was made by occluding the right pulmonary artery for ten minutes using pulmonary artery Cuff. Assessment was repeated at the interval of 30 minutes, one hour, and two hours later after reperfusion and then chest X-ray, computed tomogram and lung perfusion scan were obtained. In survival dogs follow-up studies were done with assessment with chest X-ray, computed tomogram of the chest and lung perfusion scan on 7th day postoperatively. After preservation above 20 hours, pathological examinations for ultrastructural findings on right lung were performed in each group. Results. With respect to arterial oxygen tension, LPDG group was superior to MEC but there was no statistical significance for 2 hours after reperfusion. Mean pulmonary artery pressure was less increased(p < 0.05) and cardiac output higher(p <0.05) than MEC group until 2 hours after reperfusion. After 2 hours of reperfusion, both groups showed transplanted lung function deteriorated gradually. Perfusion scan of the transplanted lung in LPDG group showed better perfusion rate in immediate post-reperfusion, 3 days and 7 days later respectively but there was no statistical significance and corelation with PaO2 and computed tomoRravhic views. In scanning electron microscopy of pulmonary artery after preservation, LPDG group relatively shows less irregular protrusion of the inner surface of endothelial cell of poulmonary artery than MEC group. Conclusions, e concluded that LPDG solution can offer safe lung preservation above 20 hours with adequate immunosuppressive therapy and prevention of the infection.

  • PDF