• Title/Summary/Keyword: cardiac pacing

Search Result 41, Processing Time 0.027 seconds

A technique for treating exposed cardiac Pacemaker (피부괴사로 노출된 심장 Pacemaker에 대한 처치 : 증례 보고)

  • Sin, Geuk-Seon;Yu, Jae-Deok;Hong, Seung-Rok
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.125-128
    • /
    • 1984
  • The management of the exposed cardiac pacemaker or its lead is a new challenge to the plastic surgeon. This complication is not rare. Coburn et al. [1972] reported less than 5 percent, but Sowton et al. [1974] showed that over a period of 19 years, in a series of 372 patients, the pacing system had to be removed because of local wound breakdown or infection in 10 percent of the cases. The methods used to treat exposure may vary from removal and re-introduction at anterior site to the rotation of local flaps to cover the exposed pacemaker. Recently we have experienced 6 times of migration and recurrent skin ulcerations without pyogenic infection overlying the pacemaker in one patient. We developed a new technique, anchoring the pacemaker to the clavicle by a wire through the hole of clavicle and by creating a pocket under the pectoralis major muscle. Then we would like to emphasize this operating method could be choice of treatment to prevent the migration of pacemaker and the ulceration of skin when complication of implantation of pacemaker is occurred.

  • PDF

Rate-Responsive Permanent Pacemaker Implantation in a Pekingese Dog with a Sick Sinus Syndrome (동방결절 기능 부전군을 가진 페키니즈 종의 개에 대한 심장 박동수 반응형 영구 심장 박동기의 장착)

  • Han, Dong-Hyun;Choi, Ran;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.569-572
    • /
    • 2010
  • A 4-year-old neutered female Pekingese dog (weighing 3.6 kg) was referred with the primary complaint of exercise intolerance with occasional syncope. Physical examination revealed irregularly irregular heart rhythm with persistent pulse deficits. The 12-lead surface ECG showed a marked sinus arrest with occasional junctional escape beats, indicating a sick sinus syndrome. Permanent transvenous cardiac pacing with a rate-responsive bipolar implantable pacemaker (VVIR type) was performed in the right ventricle. After pacemaker implantation, the clinical signs were remarkably improved. No further syncopal episodes have yet been occurred after implantation.

Design and Evaluation of Blending Algorithm for Rate Adaptive Pace: Simulation Study (심박수 적응형 심박 조율 알고리즘 설계 및 평가: 시뮬레이션 연구)

  • Myoung, Hyoun-Seok;Lee, Kyoung Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.32-37
    • /
    • 2019
  • In this study, we designed a blending algorithm for rate adaptive pacing for cardiac pacemaker. Generally, rate adaptive pacing (RAP) is applied to patients whose heart rate does not rise during exercise for chronotropic incompetence (CI) patient. It is very important to develop an algorithm for RAP that can be properly applied to CI patients. In order to design an RAP algorithm we used dual sensors. Firstly, we designed a bio-signal measurement system based on the dual sensors, which are accelerometer and respiratory system. Secondly, we conducted treadmill test for the simulation experiment while using 3-lead ECG as reference. Finally, we designed a blending algorithm based on activation state of the dual sensors. The proposed blending algorithm was subdivided into three sections based on the accelerometer signal, which are rapidly increased section (W1), hardly changed section (W2), and decreased section (W3). Each weight is set aside for each section. To evaluate this algorithm, ten healthy adult males were participated. The correlation and Root Mean Square Error between the proposed algorithm and the reference were compared, and shown to be r=0.88 and 2.82 bpm, respectively. These results show that the proposed blending algorithm of dual sensors enables proper tracking of the heart rate during exercise. Also, it shows the possibility that the proposed blending algorithm can be applied to improve quality of life of the chronotropic incompetence patient.

Isolated Working Canine Heart Perfusion Apparatus for Evaluation of Myocardial Protection Methods (심장기능 평가를 위한 견 적출심장 관류장치의 설계)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.246-253
    • /
    • 1988
  • An in vitro model providing with a recirculating perfusion apparatus using an isolated canine heart and its autogenous blood, which was prepared for study of myocardial protection method. This apparatus was easily used by quick connect system and maintained well heart function for about 2 hours. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at 37` into the aorta from aortic reservoir located 100 cm above the heart. The isolated perfused working canine heart model was a left heart preparation in which oxygenated perfusion medium [at 37K] entered the cannulated left atrium at a constant flow rate [900ml/ min] under 20 mmHg overflow system and was spontaneously ejected[no electrical pacing] via an cannula against a hydrostatic pressure of 80 cm H2O. During this working period, various indices of cardiac function were measured. The cardiac functions were stable for over 2 hours with perfusion of Krebs-Henseleit solution and autologous blood[1:1] mixture in volume and maintained heart rate ]]3-122/bpm peak systolic pressure 109-113 mmHg, cardiac output 900 ml / min and left atrial mean pressure 8-9 mmHg. In this model, the efficiency of myocardia] protection could be easily measured by means of functional, enzymatic, biochemical and ultrastructural assessment. And also, we believe this model to be a useful assessment screening model of recovery state after long duration of myocardial preservation of donor heart without difficult transplantation procedures.

  • PDF

Analysis of risk factors of atrial fibrillation after coronary artery bypass grafting (관상동맥 우회로 조성수술후 발생하는 심 방세동의 위험요인 분석)

  • Yu, Gyeong-Jong;Go, Yeong-Ho;Im, Sang-Hyeon;Gang, Myeon-Sik
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.599-605
    • /
    • 1996
  • A total of 249 patients undergoing isolated coronary revascularization were studied for the occurrence of postoperative atrial fibrillation(AF). Possible associations of this arrhythmia with various preoperative, intraoperative and postoperative factors were studied by univariate and multivariate analysis. The overall incidence of postoperative AF was 15%, with the median time occurence of 48 hours(mean time : 59.1 $\pm$ 56.9 hours) after arrival to the intensive care unit. Cardiac index decreased significantly after occurence of AF(p=0.001). There were no in-hospital complications in those patients with AF. Univariate studies indicated preoperative ejection fract on(EF), triglyceride level, postoperative peak CKMB isoenzpme and atrial pacing to be the dominant factor promoting postoperative AF, with an increasing prevalence in lower EF(p=0.025), triglyceride(p=0.006) and peak CKMB isoenzyme(p=0.002), and in patients with atrial pacing(p=0.001). Hospital stay(p=0.001) and late mortality(p=0.003) were significantly increased in patients with postoperative AF Multivariate analysis showed that body weight and postoperative atrial pacing to be the dominant factor promoting postoperative AF, with an increasing prevalence in over- weight patients(p=0.011) and patients with atrial pacing(p=0.001). Both univariate and multivariate analy- sis showed that the age was not a significant factor but tended to promote postoperative AF respectively (p=0.053, 0.064). After 30.1 $\pm$ 11.4 months gfollow-up, those patients with AF had sinus rhythm. We think that we must try to prevent postoperative AF after ccoronary artery bypass grafting because of its deleterio s hemodynamic effect, prolonged hospital stay, and increased late mortality.

  • PDF

A case of various clinical aspects associated with cardiotoxicity after glufosinate poisoning (글루포시네이트 중독 후 심장독성의 다양한 임상경과를 보인 1례)

  • Kim, Seon Tae
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.2
    • /
    • pp.133-138
    • /
    • 2021
  • Glufosinate-containing herbicides is a non-selective herbicide commonly used worldwide. As the use of them increased gradually since paraquat was banned in 2012, the number of suicides by their ingestion is also increasing continuously. Complications of glufosinate-containing herbicide poisoning include various central nervous system (CNS) toxicities such as convulsions, loss of consciousness, memory impairment, and respiratory depression, which may be accompanied by hemodynamic changes such as bradycardia and hypotension. However, it is very rare that arrhythmias other than bradycardia occurred and Takotsubo cardiomyopathy was combined due to cardiotoxicity. A 71-year-old female patient was transferred to our hospital after ingesting 500 mL of glufosinate-containing herbicide and receiving 5 L of gastric lavage at a local hospital. A few hours later, she presented stuporous mentality, respiratory depression, and convulsions, and was accompanied by hypotension and bradycardia. On the second day of admission, electrocardiogram (ECG) showed bradycardia and QTc prolongation with hemodynamic Instability. Accordingly, we conducted the early treatment with continuous renal replacement therapy (CRRT) and the application of temporary cardiac pacemaker. An echocardiogram demonstrated decreased ejection fraction (EF) and Takotsubo cardiomyopathy on the third day of admission. Then, she was discharged safely with conservative treatment. At the follow-up after 1 year, Takotsubo cardiomyopathy, EF and QTc prolongation were recovered on echocardiogram and ECG. Because cardiac toxicity after glufosinate-containing herbicide poisoning may cause life-threatening consequences, caution is required while treating the patient. Therefore, if electrocardiogram changes are seen in the elderly with a large amount of glufosinate herbicide ingestion, additional cardiac function test through echocardiography should be concerned, and early treatment through CRRT or artificial cardiac pacing should be considered.

Partial Left Heart Bypass for Perioperative Left Ventricular Failure [A Report of 2 Clinical Cases] (개심술시 병발한 좌심실 기능부전에 대한 Partial Left Heart Bypass 치험)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.193-204
    • /
    • 1985
  • During the period from February to March, 1984, we employed a partial left heart bypass [left atrium to ascending aorta] in 2 patients who could not weaned from cardiopulmonary bypass with inotropic agents and cardiac pacing after coronary bypass surgery. These two patients showed significant improvement in ventricular function 18 to 47 hours after inserting the left heart bypass and were able to wean from the left heart bypass under using inotropic agents. Two patients died of multiple organ failures 11 days and 15 days postoperatively. These results indicate that early institution of left heart bypass in ventricular failure patients after open heart surgery can provide satisfactory long-term result.

  • PDF

Perfusion Techniques Using the Modified Isolated Working Rat Heart Model (흰쥐의 심장을 이용한 Modified Isolated Working Heart Perfusion Technique)

  • Lee, Chong-Kook;Choi, Hyeong-Ho
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.338-345
    • /
    • 1980
  • We have modified an isolated perfusion rat heart model of cardiopulmonary bypass, with which we are able to screen the effects of various cardioplegic solutions and hypothermia upon the ability of the heart to survivie during and recover from period of ischemic arrest. The modified experimental model was differed from the original as follow : a heat coil chamber of atrial and aortic reservoir provided temperature control, and the perfusate was gassed with each pure oxygen and pure carbon dioxide in 95:5 ratio. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at $37^{\circ}C.$ into the aorta from the aortic reservoir located 100 cm above the heart. The isolated perfused working rat heart model was a left heart preparation in which oxygenated perfusion medium (at $37^{\circ}C.$) entered the cannulated left atrium at a pressure of 20 cm $H_{2}O$ and was passed to the ventricle, from which it was sponeously elected(no electrical pacing) via an aortic cannula, against a hydrostatic pressure of 100cm $H_{2}O$. during this working period various indices of cardiac functin were measured. The cardiac functions were stable for over 3 hour with perfusion of Krebs-Henseleit bicarbonate buffer solution containing only glucose (11.1 mM/L). The percentage of cardiac functins were maintained about 94% on heart rate, 80.6% on peak aortic pressure, 87.7% on coronary flow and 76.3% on aortic flow rate after 3 hour of working heart perfusion at a pressure of 20 cm $H_{2}O$. We believe this preparation to be a good biochemical model for the human heart which offers many advantages including economic, speed of preparation, reproducibility, and the ability to handle large numbers.

  • PDF

Testing of Common Electromagnetic Environments for Risk of Interference with Cardiac Pacemaker Function

  • Tiikkaja, Maria;Aro, Aapo L.;Alanko, Tommi;Lindholm, Harri;Sistonen, Heli;Hartikainen, Juha E.K.;Toivonen, Lauri;Juutilainen, Jukka;Hietanen, Maila
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.156-159
    • /
    • 2013
  • Background: Cardiac pacemakers are known to be susceptible to strong electromagnetic fields (EMFs). This in vivo study investigated occurrence of electromagnetic interference with pacemakers caused by common environmental sources of EMFs. Methods: Eleven volunteers with a pacemaker were exposed to EMFs produced by two mobile phone base stations, an electrically powered commuter train, and an overhead high voltage transmission lines. All the pacemakers were programmed in normal clinically selected settings with bipolar sensing and pacing configurations. Results: None of the pacemakers experienced interference in any of these exposure situations. However, often it is not clear whether or not strong EMFs exist in various work environments, and hence an individual risk assessment is needed. Conclusions: Modern pacemakers are well shielded against external EMFs, and workers with a pacemaker can most often return to their previous work after having a pacemaker implanted. However, an appropriate risk assessment is still necessary after the implantation of a pacemaker, a change of its generator, or major modification of its programming settings.

Implantation of a permanent pacemaker through the coronary sinus in a patient who underwent mechanical valve replacement for infective endocarditis with a complete atrioventricular block (완전방실차단을 동반한 감염성 심내막염 환자에서 판막치환술 후 관정맥동을 통해 좌심실을 조율하는 심박조율기 시술)

  • Jo, Kwan Hoon;Kim, Inho;Ann, Soe Hee;Oh, Yong Seog
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.113-116
    • /
    • 2014
  • A 52-year-old man was referred to our hospital due to fever and myalgia that occurred 2 weeks earlier. He showed a complete atrioventricular block on his electrocardiogram, and his vital signs were unstable. On his transthoracic echocardiograph, the 1.5 cm vegetation in the aortic valve with severe aortic regurgitation suggested infective endocarditis. His transesophageal enchocardiograph showed abscess in his mitral-aortic intervalvular fibrosa and vegetation was suspected on his anterior mitral valve leaflet. The patient underwent an emergent operation for valve replacement with temporary epicardial pacing. Intraoperatively, the septal leaflet of his tricuspid valve was injured during the debridement of the abscess pocket that was extended to the membranous septum. The aortic, mitral, and tricuspid mechanical valves were replaced with annular reconstruction without complications. After 14 days of intravenous antibiotics, we successfully changed the epicardial pacemaker into a transvenous DDD-type permanent pacemaker by placing a left ventricular lead via the coronary sinus and an atrial lead in the right atrium appendage. The patient was discharged in a tolerable state and was examined uneventfully in our hospital's outpatient clinic for 8 months.