• Title/Summary/Keyword: cardiac mass

Search Result 187, Processing Time 0.027 seconds

Professional Certification of Medical Technologists in Korea, Japan, and United States of America (한국, 일본, 미국 임상병리사 전문자격)

  • Koo, Bon-Kyeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.1-14
    • /
    • 2019
  • The names of medical technologist in Korea, Japan, and the United State of America vary depending on the medical system, educational system, and work areas. Conventionally, jobs equal or similar to medical technologist (commonly known as clinical laboratory technologist, medical laboratory technologist, clinical laboratory scientist, and medical laboratory scientist), histotechnologist, cytotechnologist, and genetic technologist. Jobs, such as extracorporeal technologist, medical electrophysiology technologist, and medical sonographer, allow other allied health professionals including medical technologists, to obtain their qualification. The work areas of medical technologists are classified into clinical pathologic technology, pathologic technology, clinical genetics technology, nuclear medicine in vitro technology, and clinical physiologic technology. New titles of Korean specialized medical technologists refer to certification systems, such as CLMJ, CMAJ, ASCP, IAC, ABRET, and ARMDS. Currently, there are eight types of specialized medical technologists under the cooperation of specialized academic societies. They are hematology, transfusionology, chemistry, immunology, microbiology, histology, cytology, nuclear medicine. It can be further divided into 20 categories according to the work areas such as mass spectrometry, infection control, Pathologists' Assistant, flow cytometry, HLA, cytogenetics, molecular genetics, cardiopulmonary physiology, neurophysiology (EEG/EMG/PSG/etc.), cardiac sonography, neurosonography (TCD/carotid), and medical device quality manager.

Hemodynamic, Autonomic, and Vascular Function Changes after Sleep Deprivation for 24, 28, and 32 Hours in Healthy Men

  • Slomko, Joanna;Zawadka-Kunikowska, Monika;Kozakiewicz, Mariusz;Klawe, Jacek J.;Tafil-Klawe, Malgorzata;Newton, Julia L.;Zalewski, Pawel
    • Yonsei Medical Journal
    • /
    • v.59 no.9
    • /
    • pp.1138-1142
    • /
    • 2018
  • This study aimed to analyze the impact of sleep deprivation (SD) on cardiac, hemodynamic, and endothelial parameters and to determine whether these are sustained with increased periods of SD. The study included 60 healthy men (mean: age $31.2{\pm}6.3years$; body mass index $24.6{\pm}2.6kg/m^2$). Hemodynamic parameters, parameters of myocardial contractility, spectral analysis of heart rate (HR) and blood pressure (BP) variability, and the sensitivity of arterial baroreflex function were evaluated. Biochemical tests were performed to assess L-arginine (L-Arg) and asymmetric dimethylarginine (ADMA) levels in reflection of endothelial nitric oxide synthase ability. Measurements of cardiovascular system parameters were obtained at 9 a.m. (baseline) on the first day of the study and 9 a.m. (24-h SD), 1 p.m. (28-h SD), and 5 p.m. (32-h SD) on the second day. Blood samples for evaluating biochemical parameters were obtained at baseline and after 24-h SD. ANOVA Friedman's test revealed a significant effect for time in relation to HR (${\chi}^2=26.04$, df=5, p=0.000), systolic BP (${\chi}^2=35.98$, df=5, p=0.000), diastolic BP (${\chi}^2=18.01$, df=5, p=0.003), and mean BP (${\chi}^2=28.32$, df=5, p=0.000). L-Arg and ADMA levels changed from $78.2{\pm}12.9$ and $0.3{\pm}0.1$ at baseline to $68.8{\pm}10.2$ and $0.4{\pm}0.1$ after 24-hr SD, respectively (p=0.001, p=0.004). SD in healthy men is associated with increases in BP, which appear to occur after 24 hours of SD and are maintained over increasing periods of SD. The observed hemodynamic changes may have resulted due to disordered vascular endothelial function, as reflected in alterations in L-Arg and ADMA levels.

Aortic Unfolding Measurement Using Non-Contrast Cardiac CT: Normal Range of Low-Risk Subjects (관상동맥 석회화 CT에서 측정한 대동맥 전개: 저위험 환자군에서의 정상 범위)

  • Ji Won Lee;Byoung Wook Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.360-371
    • /
    • 2022
  • Purpose This study aimed to assess the factors influencing aortic unfolding (AU) defined by aortic width on coronary artery calcium (CAC) scan and determine the normal limits for AU. Materials and Methods In this retrospective study, we measured AU in 924 asymptomatic subjects who underwent CAC scanning during routine health screening from June 2015 to June 2018. Multivariate regression analysis was used to evaluate the factors influencing AU. After the exclusion of subjects with risk factors associated with AU, 283 subjects were included in the analysis of normal values of AU. Mean AU, standard deviation, and upper normal limit were calculated. Results Sex, age, CAC score, body mass index, body surface area, hypertension, left ventricular hypertrophy, plasma creatinine, and smoking were significantly associated with AU. The mean AU was 102.2 ± 12.8 mm for men and 93.1 ± 10.7 mm for women. AU increased with advancing age (9.6 mm per decade). Conclusion AU determined from a single measurement on CAC scans was associated with cardiovascular risk factors. The normal limits of AU were defined by age, sex, and body surface area in low-risk subjects in this study.

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.

The Study on Ejection Fraction Change According to Patient Position Difference in Gated Blood Pool Scan (게이트심장혈액풀 스캔에서 환자의 자세 변화에 따른 심박출계수의 변화 연구)

  • Choi, Ho-Yong;Kim, Da-Eun;Jeong, Jae-Hun;Yun, Sang-Hyeok;Kim, Yeong-Seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.91-95
    • /
    • 2012
  • Purpose: In this study, we evaluated the ejection fraction (EF) according to the difference of patient position in Gated Blood Pool (GBP) scan. Material and Methods: The analysis was performed to 80 patients ($51.2{\pm}17.4$ years old) who examined GBP scan in Department of nuclear medicine, National Cancer Center from March 2011 to August 2011. We divided the patients into two groups; one group received conventional position (raise left arm up supine) and supine position (group 1) and the other group received conventional position and left arm back down supine position (group 2). To observe the change EF according to patient position difference, the image was reconstructed and analyzed by Xeleris (GE, USA). We measured body mass index (BMI) of patients. Result: In group 1, EF error less than 3% occurred at a rate of 72.5% (29 of the 40 patients). In group 2, EF error less than 3% occurred at a rate of 79% (32 of the 40 patients). The patient's BMI did not affect ejection fraction. Conclusion: The EF error of left arm back down supine position closer to conventional position than in supine position shows the results.

  • PDF

Effects of Mulberry-Leaf Powder Tofu Consumption on Serum Lipid Profiles, Ca, Ca/P Ratio and Pb Status in Middle-Aged Women (뽕잎분말 첨가두부 섭취가 비만 중년여성의 혈청 지질, 칼슘, 칼슘/인 비율 및 납 수준변화에 미친 영향)

  • Kim, A.J.;Kim, M.H.;Chung, Kun-Sub
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.432-437
    • /
    • 2006
  • This study was carried out to investigate the effects of mulberry-leaf powder Tofu (MPT) on serum lipids profiles, Ca levels, Ca/P ratio and Pb levels in 30 middle aged obese women living in the Choongnam area. 100 g/day MPT was consumed for 4 weeks. The nutrient contents per 100 g MPT were 86.71 kcal (energy), 8.98 g protein, 0.53 mg fiber, 211.33 mg Ca and 1.59 g fat. Anthropometric measurements, 24 h recall dietary intakes, serum levels of protein, albumin, glucose, Ca and Pb, lipid profiles (cholesterol, triglyceride, HDL-cholesterol, LDL-cholesterol), and the Ca/P ratio were analyzed before and after consumption of MPT. After consumption of MPT, there were no significant differences in anthropometric measurements, the levels of serum protein, albumin, glucose, total cholesterol, HDL-cholesterol, lipase activity, HTR (HDL-cholesterol/total cholesterol), CRF (cardiac risk factor), Ca, Ca/P ratio and Pb. There were decreases in the levels of serum triglyceride, LDL-cholesterol, AI (atherogenic index) and LHR (LDL-cholesterol/HDL-cholesterol). Significantly increased dietary intakes of plant protein, total Ca, and plant Ca were observed.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.