• Title/Summary/Keyword: carbon fiber sheets (CFS)

Search Result 49, Processing Time 0.023 seconds

A Study on the Flexural and Shear Behavior of Repaired and Rehabilitated RC Beams (보수$\cdot$보강된 철근콘크리트 보의 휨 및 전단 거동에 관한 연구)

  • 김태봉;이재범;류택은
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.129-140
    • /
    • 1999
  • This study presents test results of RC beams strengthened by steel plates, carbon fiber sheets(CFS) and aramid fiber sheets(AFS) for increasing flexural and shear resistance. The test was performed with different parameters including the type of strengthening materials, flexural-strengthening methods and shear-strengthening methods. In case of flexural test, RC beams are initially loaded to 70% of the ultimate flexural capacity and in case of shear test loaded to 60 or 80 percent of the ultimate shear capacity and subsequently reinforced with steel plates, CFS and AFS. Experimental data on strength, steel strain, deflection, and mode of failure of the reinforced beams were obtained, and comparisons between the different shear reinforced schemes and the non-strengthened control beams were made. The test results showed that damaged RC beams strengthened by steel plates, CFS and AFS have more improved the flexural and shear capacity. For the beams with external reinforcement by steel plates, aramid fiber sheets and carbon fiber sheets increases in ultimate strength of 4 to 21, 17 to 43 and 26 to 36 percent were respectively achieved. Initial load had small effect on strength after reinforcement, but an important influence on deflection. One sheet reinforced was stronger than two sheets reinforced but less deflected than two sheets reinforced.

  • PDF

A Study on the Axial Behavior of the Concrete Cylinders Confined by Carbon Fiber Sheets (탄소섬유쉬트로 횡구속된 콘크리트 공시체의 압축 거동에 관한 연구)

  • Hwang, Jin-Seog
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.141-148
    • /
    • 2000
  • Recently the Carbon Fiber Sheet(CFS) is widely used for strengthening damaged RC structures. Strengthening compression members such as column can increase ductility and strength due to the confinement effect. In this experiment, the behavior of concrete cylinders confined by CFS was examined. The confinement pressure is increased linearly as axial stress is increased in low axial stress, and the confinement effect of CFS was rapidly developed after near maximum axial stress, thus axial strength and ductility was improved. As the ratio of CPS is increased, concrete cylinders failed due to local fracture of CFS. The confinement effect of circular section is more efficient than that of rectangular section. And significant improvement of axial strength, axial strain, transverse strain at failure is observed in circular section. This is because in rectangular section the local fracture of CFS near corner may be occured, thus the strain efficiency ratio must be considered for RC structures with CFS.

  • PDF

Improvement in Fatigue Durability of RC Beams Strengthened with Carbon Fiber Sheets (탄소섬유시트로 보강된 RC 보의 피로내구성 향상에 관한 연구)

  • Park, Jeong-Yong;Kim, Seong-Do;Jo, Baik-Soon;Kim, In-Tae;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.6
    • /
    • pp.205-212
    • /
    • 2006
  • In recent investigations, reinforced concrete beams strengthened with Carbon Fiber Sheets (CFS) subjected to fatigue loading were reported to be failed at the ends of CFS by its debonding. U-shaped CFS were attached to both ends of the CFS when fatigue tests on strengthened beams were conducted to delay and/or prevent fatigue failures of adhesive interface. The experimental parameters of this study were the usage of anchorage at the ends of CFS, the number of CFS layers, and the applied load levels of 60%~90% of the static ultimate load obtained from the static tests. The failure modes and the load cycle-deflection relations were observed and discussed from the experimental results. Those results also showed that the U-shaped anchoring system changes the fatigue failure modes and influences greatly on the fatigue capacity of the strengthened beams.

Interface Debonding of Reinforced Concrete Beams Strengthened with Carbon Fiber Sheets (탄소섬유시트 보강 철근콘크리트보의 계면박리에 관한 연구)

  • 박주현;이우철;정진환;조백순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.355-358
    • /
    • 2003
  • The strengthening method with CFS(Carbon Fiber Sheet) to reinforced concrete structures has a fatal defect. Strengthened beams have been almost failed far below their ultimate strength due to interface debonding failure between the surface of concrete and CFS. The purpose of this study is to investigate the failure mechanism and failure behavior of strengthened RC beam using CFS.

  • PDF

FEM Analysis of Reinforced Concrete Columns Shear Strengthened with Carbon Fiber Sheets (탄소섬유시트로 전단 보강된 철근콘크리트 기둥의 유한요소해석)

  • Lee, Yong-Taeg;Na, Jung-Min;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.111-118
    • /
    • 2002
  • In this paper, FEM analysis is performed in order to estimate the behavior of RC columns retrofitted with Carbon Fiber Sheet(CFS). Two node truss element and four node isometric plate bond element are used for modeling the CFS and the adhesion between concrete and CFS, respectively. Five specimens with different quantity of CFS are analyzed and compared with experimental results. From the comparison, analytical results show a good agreement with the test results. Therefore, it is advisable to use the FEM used in this paper to predict the behavior of columns with CFS.

A Comparative Study on the Shear-Strengthening Effect of RC Beams Strengthened by FRP (FRP로 보강된 RC보의 전단보강효과 비교연구)

  • 심종성;김규선
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.101-111
    • /
    • 1998
  • This study presents test results of RC beams strengthened by carbon fiber sheet(CFS), carbon fiber reinforced plastics(CFRP) or glass fiber reinforced plastics(GFRP) for increasing shear resistance. Nineteen specimens were tested, and the test was performed with different parameters including the type of strengthening materials(CFS, GFRP, CFRP), shear-strengthening methods(wing type, jacket type, strip type), strip-spacing, strengthening direction of FRP. The test results show that shear-damaged RC beams strengthened by FRP(CFS, GFRP, CFRP) have more improved the shear capacity. The mathematical model based on plastic theory was also developed to predict shear strength of shear-damaged RC beams strengthened by FRP. The predictions using the mathematical model. are agreed with the observations from the observed shear strengths for 19 test beams.

An Experimental Study to Prevent Debonding Failure of Full-Scale RC Beam Strengthened with Multi-Layer CFS

  • You Young-Chan;Choi Ki-Sun;Kim Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.867-873
    • /
    • 2004
  • It has been known that debonding failures between CFS(Carbon Fiber Sheet) and concrete in the strengthened RC beams are initiated by the peeling of the sheets in the region of combined large moment and shear forces, being accompanied by the large shear deformation after flexural cracks. These shear deformation effects are seldom occurred in small-scale model tests, but debondings due to the large shear deformation effects are often observed in a full-scale model tests. The premature debonding failure of CFS, therefore, must be avoided to confirm the design strength of full-scale RC beam in strengthening designs. The reinforcing details, so- called 'U-Shape fiber wrap at mid-span' which wrapped the RC flexural members around the webs and tension face at critical section with CFS additionally, were proposed in this study to prevent the debonding of CFS. Other reinforcing detail, so called 'U-Shape fiber wrap at beam end' were included in this tests and comparisons were made between them.

A Study on the Shear Behavior of Strengthened R/C Beams with CFS (탄소섬유쉬트로 보강한 R/C보의 전단거동에 관한 연구)

  • Shin, Sung-Woo;Bahn, Byong Youl;Lee, Kwang Soo;Cho, In-Chol;Nam, Jeong-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.3
    • /
    • pp.205-211
    • /
    • 1998
  • The purpose of this study is to evaluate shear strengthening effects of R/C beams with carbon fiber sheets. The major variables are shear reinforcement ratios, CFS strengthening ratios and strengthening methods of CFS. Following conclusions can be extracted. The shear capacity of beam strengthened with CFS is about 32~87% higher than that of beams without shear reinforcement. The strengthening effects of patch type is larger than those of strip type. The strain distribution in CFS intersected with shear crack is similar to that in stirrup and larger strain is observed in the middle of the shear span. It can be estimated that shear strength reduction factor ${\alpha}$=0.3 is appropriate for peeling effect of CFS.

  • PDF

Effect of Strengthening amount and length of CFS on Flexural Behavior of RC Beams (탄소섬유쉬트의 보강량 및 정착길이가 RC보의 휨거동에 미치는 영향)

  • Shin, Sung Woo;Bahn, Byong Youl;Ahn, Jong Mun;Cho, In Chol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.195-201
    • /
    • 1998
  • The purpose of this study is to evaluate the flexural strengthening effects of RC beams reinforced with carbon fiber sheets (CFS) in variable of strengthening amount and anchorage length of CFS. This study can be summarized as follows ; The CFS shares the tensile stress such as rebar during loading test. Also, as the strengthening amount of CFS is increased, the maximum flexural strength of RC beams reinforced with CFS is increased. Therefore, it is confirmed that the CFS's strengthening method is very effective to improve the flexural strength of RC beams. The maximum flexural strength of RC beams with CFS is determined by bond failure between CFS and concrete surface. So, the evaluation of CFS's strengthening effect can be calculated using the tensile stress of CFS which is peeling. When the anchorage length of CFS is increased, the ductility of RC beams is increased because of delaying the peeling of CFS. But, in case of same anchorage length of CFS, when the strengthening amount of CFS is increased, the ductility is decreased. Therefore, it is considered that the anchorage of CFS in the end zone is necessary.

  • PDF

Effect of Strengthening amount and length of CFS on Flexural Behavior of RC Beams (탄소섬유쉬트의 보강량 및 정착길이가 RC보의 휨거동에 미치는 영향)

  • 신성우;반병렬;안종문;조인철;김영수;조삼재
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.579-584
    • /
    • 1998
  • The purpose of this study is to evaluate the flexural strengthening effects of RC beams reinforced with carbon fiber sheets (CFS) in variable of strengthening amount and anchorage length of CFS. This study can be summarized as follows. The CFS shares the tensile stress such as rebar during loading test. Also, as the strengthening amount of CFS is increased, the maximum flexural strength of RC beams reinforced with CFS is increased. Therefore, it is confirmed that the CFS's strengthening method is very effective to improve the flexural strength of RC beams. The maximum flexural strength of RC beams with CFS is determined by bond failure between CFS and concrete surface. So, the evaluation of CFS's strengthening effect can be calculated using the tensile stress of CFS which is peeling. When the anchorage length of CFS. But, in case of same anchorage length of CFS, when the strengthening amount of CFA is increased, the ductility is decreased. Therefore, it is considered that the anchorage of CFS in the end zone is necessary.

  • PDF