• 제목/요약/키워드: carbon dioxide ($CO_2$) storage

검색결과 219건 처리시간 0.023초

The CO2 Reduction Potential Calculation through the Urban Park Construction

  • Lee, Eun Yeob;Kang, Myung Soo;Kim, Jong Kon
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.87-98
    • /
    • 2014
  • This study is to identify quantitatively the function of carbon dioxide emissions reduction due to temperature and energy reduction according to direct carbon dioxide storage, shade provision, and evaportanspiration of urban park. According to the result of study, landscape tree indicated high carbon dioxide storage effect compare to bush, in which broadleaf tree indicated higher storage function than coniferous tree. It is believed to be the storage of carbon dioxide can be increased by increasing the composition rate of forest plants in the urban park. According to the direct estimation result of carbon dioxide storage in terms of example area, storage of carbon dioxide is estimated to be "seoul a zone" $476,818.8kg{\cdot}CO_2/m^2yr$, "anyang b zone" $186,435.7{\cdot}CO_2/m^2yr$, "daejeon c zone" $262,826{\cdot}CO_2/m^2yr$, "kwangju d zone" $231,657.8{\cdot}CO_2/m^2yr$. The carbon dioxide storage per unit area estimated to be "seoul a zone" $3.4{\cdot}CO_2/m^2yr$, "anyang b zone" $5.0{\cdot}CO_2/m^2yr$, "daejeon c zone" $2.6{\cdot}CO_2/m^2yr$, "kwangju d zone" $5.6{\cdot}CO_2/m^2yr$. The result of indirect carbon dioxide reduction effect estimated to be "seoul a zone" $291,603.4{\cdot}CO_2/m^2yr$, "anyang b zone" $165,462.4{\cdot}CO_2/m^2yr$, "daejeon c zone" $141,719.2{\cdot}CO_2/m^2yr$, "kwangju d zone" $154,803.4{\cdot}CO_2/m^2yr$. Carbon dioxide reduction potential amount through the urban park was increased to 1.6 times to 1.8 times when calculated to the indirect effect.

김치용기에서의 이산화탄소 농도 제어를 위한 주입 프로그램 조건 설정 (Programmed Conditions of Supplying Carbon Dioxide to Keep its Desired Concentration in Kimchi Container)

  • 안덕순;조민경;박수연;이동선
    • 한국포장학회지
    • /
    • 제25권2호
    • /
    • pp.31-35
    • /
    • 2019
  • Kimchi is a refreshing sour food which gives sour and carbonic acid taste of carbon dioxide produced during the fermentation process. So, carbon dioxide injection was tried to raise carbonic acid taste of kimchi stored in the airtight container. First, carbon dioxide injection times of a given gas supply system were determined experimentally to attain initial concentration of 80% for different solid/liquid ratios. Since carbon dioxide is dissolved in kimchi to decrease its concentration during storage, periodical carbon dioxide injection conditions were needed and determined to keep the $CO_2$ concentration above 70%. For the initial flushing to 80% $CO_2$ concentration in model system filled with water, the injection time ranged from 40 to 89 seconds for free volumes of 2-8 L. $CO_2$ injection conditions for the under-ripened storage at $10^{\circ}C$ consisted of longer time at more frequent cycles for watery kimchi than for Chinese cabbage kimchi. At $0^{\circ}C$ of subsequent ripened stage storage of watery kimchi, the periodical injection at 3 hour interval was required because of continuous dissolution of carbon dioxide. However, Chinese cabbage kimchi did not require subsequent $CO_2$ injection during the ripened state storage and needed only flushing to 80% $CO_2$ at time of the container opening and closing. These results can be used as basic information for the programmed control of $CO_2$ injection in the kimchi container system.

이산화탄소 해양지중저장 처리를 위한 파이프라인 수송시스템의 열-유동 해석 (Thermal-Hydraulic Analysis of Pipeline Transport System for Marine Geological Storage of Carbon Dioxide)

  • 허철;강성길;홍섭;최종수;백종화
    • 한국해양공학회지
    • /
    • 제22권6호
    • /
    • pp.88-94
    • /
    • 2008
  • The concentration of atmospheric carbon dioxide (CO2), which is one of the major greenhouse gases, continues to rise with the increase in fossil fuel consumption. In order to mitigate global warming the amount of CO2 discharge to the atmosphere must be reduced. Carbon dioxide capture and storage (CCS) technology is now regarded as one of the most promising options. To complete the carbon cycle in a CCS system, a huge amount of captured CO2 from major point sources such as power plantsshould be transported for storage into the marine or ground geological structures. Since 2005, we have developed technologies for marine geological storage of CO2,including possible storage site surveys and basic design of CO2 transport and storage process. In this paper, the design parameters which will be useful to construct on-shore and off-shore CO2 transport systems are deduced and analyzed. To carry out this parametric study, we suggested variations in thedesign parameters such as flow rate, diameter, temperature and pressure, based on a hypothetical scenario. We also studied the fluid flow behavior and thermal characteristics in a pipeline transport system.

고체 이산화탄소를 이용한 고농도 이산화탄소와 예냉 처리가 싹채소의 저장성에 미치는 영향 (Effect of High Concentration Carbon Dioxide and Pre-Cooling Treated with Solid Carbon Dioxide on the Storability of Radish Sprout in MA Storage)

  • 강호민;최인이;김일섭;박권우
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.285-290
    • /
    • 2009
  • 유통기한이 7일 밖에 되지 않는 무싹의 저장성 향상을 위해서 고체 이산화탄소를 처리하였다. 이를 위해 고체 이산화탄소의 승화시 발생하는 이산화탄소가스와 극저온의 온도로 농산물에 고이산화탄소 처리와 예냉처리를 동시에 할 수 있는 처리 장치를 개발하였는데 개발된 장치는 처리 대상 작물 주위를 10분만 $5^{\circ}C$와 80% 이산화탄소로 조성하였다. 개발된 고이산화탄소 처리 장치를 이용하여 저장 전과 저장 중의 고체 이산화탄소 처리와 저장 전과 저장 중을 모두 한 처리, 그리고 무처리구를 두어 무싹의 저장성을 비교하였다. 고이산화탄소를 처리한 무싹은 $25{\mu}m$ ceramic film 포장하여서 $8^{\circ}C$에 저장하였다. 무순의 고이산화탄소 처리는 생체중 감소에는 영향을 주지 못하였고 저장 1일 째 포장내 이산화탄소와 산소 농도는 저장 중 처리구에서 40%와 10%로 고이산화탄소 농도를 보였으나 저장 7일째에는 모든 처리구의 이산화탄소 농도는 5% 미만으로 감소하였다. 고농도 이산화탄소 처리는 저장 15일째 에틸렌 농도를 낮추는 효과를 보였으나. 외관상 품질과 이취에서는 효과를 보이지 않았다.

탄소 제로화를 위한 혁신 기술 연구: 건설 및 콘크리트 산업에서의 이산화탄소 저감 방안 동향 (Research on Innovation Technologies for Zero Carbon: Carbon Dioxide Reduction in Construction and Concrete Industries)

  • 김주현;박정준;김종규
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.549-563
    • /
    • 2022
  • Continuous global warming is causing ecosystem destruction and direct damage to human life. The main cause of global warming is greenhouse gases, which account for more than 90 % of carbon dioxide. The leaders of each country signed the Paris Agreement at the United Nations Convention on Climate Change (UNFCCC) to reduce greenhouse gas emissions. Currently, the total amount of CO2 emitted from South Korea is 664.7 million tons as of 2018, ranking eighth in the world. 37 % of South Korea's total CO2 emissions come from the construction & building field, especially the cement production, which is a construction material. Carbon reduction technologies can be largely divided into four types: carbon reduction (CC), carbon reduction and storage technology (CCS), carbon reduction and utilization technology (CCU), and carbon reduction, storage and utilization technology (CCUS). Overseas, CCUS technology is mainly applied to reduce and store CO2 emitted from construction and construction field. A technology for permanently storing CO2 through mineralization by capturing CO2 and utilizing CO2 into a cement production process was developed, and this technology is applied to the entire cement industry. However, the development of CCUS technology applicable to the cement industry is still insignificant in South Korea. In this study, carbon dioxide reduction technology and methods for reducing carbon dioxide emitted during the cement manufacturing process, which is the main component of concrete mainly used in civil engineering construction, were investigated. Overseas, it has reached the commercialization stage beyond the demonstration stage as a way to reduce carbon dioxide by vomiting carbonation reactions. Accordingly, if carbon dioxide reduction plan technology generated during cement manufacturing is developed based on domestic technology differentiated from foreign technology, it is expected to contribute one more step to the carbon neutrality policy.

이산화탄소 지중저장의 국내적용을 위한 위해성 평가 방안 (A risk assessment of $CO_2$ geological storage for domestic application)

  • 이강렬;이대수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.220.1-220.1
    • /
    • 2011
  • In recent years, the importance of Carbon Capture and Storage (hereafter CCS) is growing bigger and bigger. The development and commercialization of CCS technology are concerned for reducing carbon dioxide($CO_2$) emissions. For the most studies, the technology of $CO_2$ storage is known as the geological storage, ocean sequestration, mineral carbonation, industrial utilization, and so on. The geological storage is adjudged the most reasonable technology from economic and environmental aspects. Generally, the $CO_2$ geological storage is comprised of compression - transportation - drilling/injection - storage/management process. The critical problem is a leakage of $CO_2$ in all process. For resolving a leakage problem, it is necessary to predict and build a monitoring system. Those systems are proved safety of a leakage and received positive social perceptions of $CO_2$ geological storage. For those reasons, a risk assessment of $CO_2$ geological storage is required. A risk assessment is an estimated process of the possible effects when spilling $CO_2$. Although numerous studies of risk assessment have studied, it is incomplete to evaluate a risk and disaster quantitatively. The risk assessment will be developed for domestic application and safe $CO_2$ geological storage considering characteristics of Korea.

  • PDF

이산화탄소 포집 및 저장에 대한 대중의 인식과 수용도 (Public Awareness and Acceptance of Carbon Dioxide Capture and Storage)

  • 이상일;성주식;황진환
    • 환경영향평가
    • /
    • 제21권3호
    • /
    • pp.469-481
    • /
    • 2012
  • CCS(Carbon Dioxide Capture and Storage) is considered as the most effective counterplan in the mitigation of climate change. Even though the risk of leakage of $CO_2$ stored in the geologic formation is very low, the public is expected to disagree with the initiation of a CCS project without proper management plans ensuring the safety. In this study, recognition of laypeople were surveyed about CCS, climate change, characteristics of carbon dioxide, storage concepts, ground pressure, the impact of carbon dioxide, and carbon dioxide for leakage. Thereafter the factors that could affect to recognition of CCS were analyzed by regression analysis. A survey was carried out to find out the public understanding and awareness about climate change and CCS. It is the purpose of this study to propose appropriate risk management strategies based on the findings from the survey.

Fuji 사과의 CA저장중 저장조건이 과육갈변에 미치는 영향 (Effect of CA Storage Conditions on the Internal Breakdown of Fuji Apple Fruits under CA Storage)

  • 이주백;최종욱
    • 한국식품저장유통학회지
    • /
    • 제4권3호
    • /
    • pp.227-235
    • /
    • 1997
  • The internal breakdown of Fuji apple during CA storage classified as watercore breakdown, low temperature breakdown and CO2 injury. This study was undertaken to investigate the watercore breakdown injury factors of Korean Fuji apple during CA storage. The development of internal breakdown was more increased with the larger size, the later harvest time and the hither CO2 gas level. But in internal breakdown fruit of the titratable acidity and soluble solid decreased significantly, the pH of fruit juice and the production of carbon dioxide was greatly increased. The best gas levels of CA storage was 2% oxygen and 3% carbon dioxide. Thus, the predictable parameters of internal breakdown of fruit were increase in pH on decrease titratable acidity within 2 months of CA storage, increase carbon dioxide. So, it was found that the best CA sotrage for internal breakdown control of fruit during CA storage was delayed CA storage methods after low temperature storage immediate harvest of apple and than took a step. The delayed CA storage after low temperature storage for 2 months was more effective in the prevention of development of internal breakdown than immediate CA storage after harvest.

  • PDF

계면활성제를 활용한 이산화탄소 상태에 따른 주입특성 평가 (Characteristic of Injection According to CO2 Phases Using Surfactants)

  • 강석구;정종원
    • 한국지반환경공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.5-11
    • /
    • 2023
  • 석탄 및 석유와 같은 전통적인 화석 연료는 연소 시 발생하는 열을 통해 에너지를 공급한다. 이러한 과정에서 대기 중에 이산화탄소를 배출하고 지구 온난화를 유발한다. 이산화탄소 저감을 위해 많은 연구들이 수행되고 있다. 이러한 방안 중 하나로, 이산화탄소 지중 저장 기술이 관심을 받고 있다. 이산화탄소 지중 저장은 플랜트 등에서 발생하는 이산화탄소를 포집하여 덮개암 하부 포화지반층에 이산화탄소를 주입하여 저장하는 방법을 일컫는다. 하지만, 제한된 공간에 더 많은 양의 이산화탄소 저장을 위해서는 저장 효율의 향상이 필요하다. 따라서, 본 연구에서는 계면활성제를 활용하여 이산화탄소 지중 저장의 효율을 향상하고자 한다. 또한, 지중저장소의 위치에 따라 압력 및 온도가 상이하기 때문에 이산화탄소는 기체, 액체 및 초임계 상태로 존재가능하다. 따라서, 이산화탄소 상태에 따른 저장 효율 특성을 평가하였다. 그 결과, 주입속도 및 계면활성제의 활용은 저장 효율의 향상을 기대할 수 있고, 그 효과는 기체, 액체 및 초임계 상태 이산화탄소에 발휘되는 것을 확인하였다.

이산화탄소 지중저장 시설의 잠재적 누출 판단을 위한 DGCI(Dark Green Color Index) 적용 가능성 평가 (Applicability of DGCI (Dark Green Color Index) to Assess Potential Impacts of CO2 Leakage from the Geological Storage Site)

  • 유신이;송윤진;오희주;김유진;유가영
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.351-356
    • /
    • 2016
  • The carbon capture and storage (CCS), which collects and stores carbon dioxide in a geological site, is a promising option to mitigate climate change. However, there is the possibility of carbon dioxide leakage from the soil in the steps of collecting, transporting, and storing. To ensure the feasibility of this technology, it is important to monitor the leakage of carbon dioxide and to assess the potential impacts. As plants are sensitive to the changes in carbon dioxide in the soil environment, we can utilize plant parameter to detect the carbon dioxide leakage. Currently, chlorophyll a content is a conventional index indicating the changes in plants, however, this method is labor intensive and it only utilizes a small portion of leaves. To overcome its limitations, a simple spectroscopic parameter, DGCI (dark green color index), was suggested as an easy and quick indicator. In this study, we compared the values of chlorophyll a contents with DGCI from the experiment investigating the impacts of high underground $CO_2$ on grape plants. Results suggest that DGCI had high correlation with chlorophyll a contents and it has high potential to be utilized as an easy indicator to monitor plants' responses to $CO_2$ treatment.