• 제목/요약/키워드: capillary permeability

검색결과 128건 처리시간 0.028초

Pressure Bomb법을 이용한 섬유방향 액체투과성 측정 (Measurement of Longitudinal Liquid Permeability Using Pressure Bomb Method)

  • 허종윤;강호양
    • Journal of the Korean Wood Science and Technology
    • /
    • 제25권3호
    • /
    • pp.66-74
    • /
    • 1997
  • Liquid permeabilities of red oak and several softwoods were measured by the pressure bomb method and a modified liquid permeability method in order to investigate their efficacy. The effect of preboiling and prefreezing on wood permeability were also examined for both green and resaturated specimens. Regardless of some disadvantages these two methods were revealed as a handy tool for quick evaluation of the permeability of an unknown species. The permeabilities of the resaturated specimens increased when preboiled. but decreased when prefrozen. For green specimens, however, pre freezing increased permeability. The discrepancy of the pre freezing effect on two specimens partially attributes to their difference of initial permeabilities. For all species except radiata pine heartwood, the radii of the effective capillary pores, derived from the water potential equation, distribute from $0.42{\mu}m$ to $7.2{\mu}m$. Those of radiata pine heartwood are below $0.46{\mu}m$.

  • PDF

Comparison of the Mercury Intrusion Porosimerty, Capillary Flow Porometry and Gas Permeability of Eleven Species of Korean Wood

  • Jang, Eun-Suk;Kang, Chun-Won;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권6호
    • /
    • pp.681-691
    • /
    • 2018
  • The typical methods of mercury intrusion porosimetry (MIP) and capillary flow porometry (CFP) were used to evaluate the pore size of cross-section of wood and the effect of the pore structure on the permeability of wood was analyzed in this study. The results of this study were as followings: The pore size of wood measured by CFP was larger than that measured by MIP except for Lime tree, Korean red pine and Paulownia. Among the three pore types of porous materials defined by IUPAC (through pores, blind pores, and closed pores), only through pores are related to permit fluid flow. MIP measures the pore size of both through pores and blind pores, while CFP measures the pore size of only constricted through pores. Therefore, pore size measured by MIP was not related to gas permeability, however pore size measured by CFP had a proportional relationship with gas permeability.

Permeability Measurement of a Circular Braided Preform for Resin Transfer Molding

  • Cho, Yun Kyoung;Song, Young Seok;Kang, Tae Jin;Chung, Kwansoo;Youn, Jae Ryoun
    • Fibers and Polymers
    • /
    • 제4권3호
    • /
    • pp.135-144
    • /
    • 2003
  • Permeability of the preform is one of key factors in design of RTM (Resin Transfer Molding) mold, determination of processing conditions, and modeling of flow in the mold. According to previous studies, permeability measured in the unsaturated fiber mats are higher than that in the saturated fiber mats by about 20% because of the capillary pressure. In this study, permeabilities of several fiber preforms are measured for both saturated and unsaturated flows. A saturated experiment of radial flow has been adopted to measure the permeability of anisotropic fiber preforms with high fiber content, i.e., circular braided preforms. In this method, four pressure transducers are used to measure the pressure distribution. Permeabilities in different directions are determined and the experimental results show a good agreement with the theory. Since permeability is affected by the capillary effect, permeability should be measured in the unsaturated condition for the textile composites to be manufactured under lower pressure as in the Vacuum Assisted Resin Transfer Molding (VARTM).

Suitable Use of Capillary Number for Analysis of NAPL Removal from Porous Media

  • Jeong, Seung-Woo,
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.25-28
    • /
    • 2004
  • The capillary number is used to represent the mobilization potential of organic phase trapped within porous media. The capillary number has been defined by three different forms, according to types of flow velocity and viscosity used in the definition of capillary number. This study evaluated the suitability of the capillary number definitions for representing TCE mobilization by constructing capillary number-TCE saturation relationships. The results implied that the capillary number should be correctly employed, according to interest of scale and fluid flow behavior. This study suggests that the pore-scale capillary number may be used only for investigating the organic-phase mobilization at the pore scale because it is defined by the pore-velocity and the dynamic viscosity. The Newtonian-fluid capillary number using Darcy velocity and the dynamic viscosity may be suitable to quantify flood systems representing Newtonian fluid behavior. For viscous-force modified flood systems such as surfactant-foam floods, the apparent capillary number definition employing macroscopic properties (permeability and potential gradient) may be used to appropriately represent the desaturation of organic-phases from porous media.

  • PDF

Mechanical, durability and microstructure properties of concrete containing natural zeolite

  • Nas, Memduh;Kurbetci, Sirin
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.449-459
    • /
    • 2018
  • Concrete is one of the most widely used construction materials in the world. Producing economical and durable concrete is possible by employing pozzolanic materials. The aim of this study is to underline the possibility of the utilization of natural zeolite in producing concrete and investigate its effects basically on the strength and durability of concrete. In the production of concrete mixes, Portland cement was replaced by the natural zeolite at ratios of 0%, 10%, 15%, and 20% by weight. Concretes were produced with total binder contents of $300kg/m^3$ and $400kg/m^3$, but with a constant water to cement ratio of 0.60. In addition to compressive and flexural strength measurements, freeze-thaw and high temperature resistance measurements, rapid chloride permeability, and capillary water absorption tests were performed on the concrete mixes. Compared to the rest mixes, concrete mixes containing 10% zeolite yielded in with the highest compressive and flexural strengths. The rapid chloride permeability and the capillary measurements were decreased as the natural zeolite replacement was increased. Freeze-thaw resistance also improved significantly as the replacement ratio of zeolite was increased. Under the effect of elevated temperature, natural zeolite incorporated concretes with lower binder content yielded higher compressive strength. However, the compressive strengths of concretes with higher binder content after elevated temperature effect were found to be lower than the reference concrete.

단일절리에서 모세관압을 고려하지 않은 불혼합성 물과 가스의 동시거동 해석 (Numerical Simulation of Immiscible Water-Gas Simultaneous Flow in the absence of Capillary Force in a Single Fracture)

  • 한일영;서일원
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제6권2호
    • /
    • pp.69-81
    • /
    • 2001
  • 매질에서 불혼합성인 물과 가스의 동시거동 해석을 위해서는 모세관압, 포화도, 상대투과계수의 구성관계가 선결되어야 한다. 그러나 모세관력이 무시될 수 있는 흐름에서는 점성마찰력이 흐름을 지배하게 되고 포화도와 상대투과계수의 구성관계가 상대적으로 중요하게 된다. 본 연구에서는 압력에 따른 점성의 변화와 포화도에 따른 상대투과계수의 변화를 절리간극의 크기별로 고려할 수 있는 2차원 유한차분 수치모형을 개발하였다. 수치모형에 이용할 상대투과계수 특성식은 일곱가지의 간극크기별 평판모형실험으로부터 구하였다. 실험으로부터 도출된 포화도와 상대투과계수 관계곡선은 기존의 경험식으로는 표현되기 어려웠으며, 따라서 새로운 경험식으로 로지스틱 방정식을 제시하였다. 이 방정식은 간극의 크기가 포함된 매개변수를 사용하였기 때문에 임의의 절리 간극크기의 적용이 가능한 형태이다. 수치모형의 검증을 위해서 상대투과계수 특성식을 수치모형에 적용하여 가스의 이동을 해석한 후, 모형실험 결과와 비교하였다. 수치모형의 현장적용성을 검토하기 위하여 지하 LPG 저장공동에 인접한 단일절리에 적용한 결과, 지하수와 프로판가스의 동시거동을 적절히 모사할 수 있었다.

  • PDF

Sintered Metal Wicks Development for the High Performance Loop Heat Pipe(LHP) Systems

  • 최지훈;성병호;유정현;서민환;김철주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2136-2141
    • /
    • 2007
  • The Loop Heat Pipe(LHP) system uses capillary forces so as to pump the working fluid from heat acquisition to heat rejecting systems. The performance of the LHP systems depends mainly upon the operating performance of the wick structure. The capillary pressure increases with decreasing the pore size of the wick structure. By the way, the wick structure's permeability decreases with decreasing the pore size and the porosity. To obtain an ideal wick, the wick structure should possess several characteristics such as the small pore size, high porosity and chemical compatibility with working fluid. Sintered metal wicks have been mainly used as the capillary wick structure mounted in LHP because of the fact that the sintered metal wick has some advantages like convenient selection of wick material, smaller pore size and so on as well as high reliability. In this study, sintered metal wicks were developed to meet required several parameters to design the high performance LHP systems for obtaining even more effective cooling technologies.

  • PDF

Permeability features of concretes produced with aggregates coated with colemanite

  • Bideci, Ozlem Salli;Bideci, Alper;Oymael, Sabit;Gultekin, Ali Haydar;Yildirim, Hasan
    • Computers and Concrete
    • /
    • 제15권5호
    • /
    • pp.833-845
    • /
    • 2015
  • In the world total boron reserve rating, Turkey is taken place on the first rank, meeting the demand of refined mineral and main boron chemicals. Development of the new boron products and production technologies, spreading the using area of the boron are the study topics which must be finically discussed. In this study, with the help of colemanite taken in ratio as (0%, 7.5%, 12.5%, and 17.5%) by being mixed by the cement, surfaces of the pumice aggregates have been covered. Permeability of the samples has been investigated by producing lightweight concrete with 400 dose with the help of aggregates covered with colemanite. For this, the experiments of water absorption, capillary water absorption, depth of penetration of water under pressure and rapid chloride permeability have been performed. In addition, analyses of the thin section of covered and uncovered pumice aggregates and SEM (Scanning Electron Microscope) have been investigated. When the control samples produced with the covered aggregates and concretes produced with colemanite covered aggregates are compared each other, it has been determined that special lightweight concretes whose values of capillary water absorption experiment, depth of penetration of water under pressure experiment and rapid chloride permeability are low can be produced.

소결윅 히트파이프의 열수송 한계에 관한 이론적 해석 (Theoretical Analysis on the Heat Transport Limitation of a Sintered Metal Wick Heat Pipe)

  • 김근배;김유
    • 한국추진공학회지
    • /
    • 제8권4호
    • /
    • pp.16-25
    • /
    • 2004
  • 구리분말 소결윅 히트파이프의 열수송 한계를 예측하는 이론적 해석을 수행하였다. 히트파이프의 직경은 8 mm이고 물을 작동유체로 사용하였다. 입자의 직경을 대표적인 5 가지로 분류하여 각각의 유효 모세관 반경($r_c$) 기공률($\varepsilon$), 투파율(K)을 토대로 작동온도와 윅 두에 그리고 경사각에 따른 모세관압력과 열수송 한계, 열저항을 분석하였다. 소결윅의 모세관한계는 입자 직경이 크고 윅 두께가 증가하며 작동온도가 높을수록 증가했다 기공률과 모세관 반경이 증가할수록 열수송 한계가 높아졌으며, 윅 두께가 증가함에 따라 열저항이 크게 상승하였다.