• 제목/요약/키워드: capacity loss

검색결과 1,690건 처리시간 0.037초

SmBCO Coated Conductor의 교류손실 측정 (Measurement of AC Loss in SmBCO Coated Conductor)

  • 박명진;김우석;이지광;오상수;하홍수;김호섭;고락길;유상임;문승현;최경달
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.52-56
    • /
    • 2008
  • According to the improvement of HTS conductor, HTS tapes which have the high current capacity have been recently researched in several nations. For large power application, AC loss is the most important issue in the development of AC superconducting power devices because it is closely related to the system operation efficiency. In 1st generation wire of HTS conductor, BSCCO, AC loss is too large to use for power application. Also, It is well known in recently years that YBCO CC, the 2nd generation wire, has also too much AC loss to apply to AC power devices. There are many trials to develop the new HTS wire having the low AC loss around the world. In this research, we present the measurment result of magnetization losses in SmBCO coated conductors. We measured the magnetization loss generated by perpendicularly exposed external magnetic field and compared with the analytic value of the strip model. Also, we presented the results compared with measured magnetization loss of an YBCO coated conductor.

Earthquake loss assessment framework of ductile RC frame using component- performance -based methodology

  • Shengfang Qiao;Xiaolei Han;Hesong Hu;Mengxiong Tang
    • Structural Engineering and Mechanics
    • /
    • 제91권4호
    • /
    • pp.369-382
    • /
    • 2024
  • The earthquake loss assessment framework of ductile reinforced concrete (or RC) frame using component-performance -based methodology was studied in this paper. The elasto-plastic rotation angle was used as the damage indicator of structural component, and the damage-to-loss model was proposed on the basis of the deformation indicator of structural component. Dynamic instability during incremental dynamic analysis was taken as collapse criterion, and column failure was taken as criterion that structure has to be demolished. Expected earthquake losses of low-rise, mid-rise and high-rise RC frames were discussed. The expected earthquake loss encompassed collapse loss, demolition loss and repair loss. Furthermore, component groups of RC frame were divided into structural components, nonstructural components and rugged components. The results indicate that ductile RC frame is more likely to be demolished than collapse, especially in low-rise and mid-rise RC frames. Furthermore, the less collapse margin ratio the structure has, the more demolition probability the structure will suffer under rare earthquake. The demolition share of total earthquake loss might be more prominent than repair share and collapse share in ductile RC frame.

초고압 대용량 O.F 케이블의 개발 (Development of ultra high voltage-large capacity O.F cable)

  • 강성호;이갑중;김천석;최영훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.265-267
    • /
    • 1991
  • In this paper, we describe the development of 345kv OF cables to contain also the cable employing new insulation paper, PPLP (Poly propylene Laminated paper). The cables all show very excellent properties, especially PPLP cable has less the dielectric loss and better the impulse & A.C strength than the one employing the conventional paper. Therefore, according to use PPLP cable, it seems to be several advantages such as the compact of system, the increasing capacity, and the decreasing energy loss etc.

  • PDF

분산형전원이 도입된 배전계통에 대한 ISLANDING DETECTION METHOD (Islanding Detection Method of Embedded Generator connected to Power Distribution System)

  • 황진수;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.522-524
    • /
    • 2000
  • The installation of small sized Embedded Generator(EG) in parallel with the utility supply was required several technical complications for protection of the system. One of the most important protection is to provide protection against islanding and out of synchronism reclosing with the utility source. This paper explains several current methods of detecting 'Loss Of Mains'(LOM). But they have not proved completely dependable, in particular when the islanded load's capacity matches that of the EG. A new loss of mains protection algorithm is presented in this paper which based on measurement of the reactive power and node voltage for detecting the islanding condition even though the EG operate in the capacity.

  • PDF

헬륨의 비이상기체 거동에 따른 VM열펌프의 손실 (Thermal Losses Due to Non-ideal Gas Behavior of Helium in VM Heat Pumps)

  • 백종훈;장호명
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.279-287
    • /
    • 1996
  • A cycle analysis is performed to investigate how the non-ideal gas behavior of helium reduces the heating capacity of VM heat pumps. Since the operating pressures of VM heat pumps are as high as 1 to 20 MPa, the compressibility factor of helium becomes clearly greater than 1 and the non-ideal behavior always represents a thermal loss in heating. To calculate the amount of the losses, an adiabatic cycle analysis is performed with the real properties of helium and the net enthaply flows through the two regenerators are numerically obtained. It is shown that the non-ideal gas losses could be as much as 8% in the heating capacity when the operating pressures are greater than 10MPa. The effects of the operating temperatures and the dead volumes on the loss are presented.

  • PDF

복합배전계통에서 분산형전원의 설치 및 운영을 위한 Fuzzy-GA 응용 (Fuzzy-GA Application for Allocation and Operation of Dispersed Generation Systems in Composite Distribution Systems)

  • 김규호;이유정;이상봉;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권10호
    • /
    • pp.584-592
    • /
    • 2003
  • This paper presents a fuzzy-GA method for the allocation and operation of dispersed generator systems(DGs) based on load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The problem formulation considers an objective to reduce power loss of distribution systems and the constraints such as the number or total capacity of DGs and the deviation of the bus voltage. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 12 bus and 33 bus test systems to demonstrate its effectiveness. .

재생 활성탄의 물성 및 흡착능 평가 (Evaluation of Physical Properties and Adsorption Capacity of Regeneration GAC)

  • 문지영;채선하;왕창근
    • 상하수도학회지
    • /
    • 제23권4호
    • /
    • pp.407-416
    • /
    • 2009
  • The objective of this study was to evaluate the variation of physical properties and adsorption capacity after regeneration of Granular Activated Carbon (GAC). It was found that the loss rate of regenerated carbon was related to the usage time of GAC. The correlations between iodide number and loss rate also determined. Effective size and uniformity coefficient for regenerated GAC were within a similar range compared to virgin GAC. This result indicated that the function as media is recovered. Although iodide number and specific surface area for regenerated GAC were not completely recovered compared to that of virgin GAC, cumulative pore volumes of regenerated GAC were increased. Removal efficiency of organic matter in regenerated GAC was resulted the same or slightly higher than that of virgin GAC. This result indicates that the number of mesopore responsible for removal of organic matter was increased after regeneration.

Characterization of Beef Transcripts Correlated with Tenderness and Moisture

  • Kee, Hyun-Jung;Park, Eung-Woo;Lee, Cheol-Koo
    • Molecules and Cells
    • /
    • 제25권3호
    • /
    • pp.428-437
    • /
    • 2008
  • To identify transcriptional markers for beef traits related to meat tenderness and moisture, we measured the transcriptome of the Longissimus dorsi skeletal muscle in 10 Korean native cattle (KNC). We analyzed the correlation between the beef transcriptome and measurements of four different beef traits, shear force (SF), water holding capacity (WHC), cooking loss (CL), and loin eye area (LEA). We obtained non-overlapping and unique panels of genes showing strong correlations (${\mid}r{\mid}$ > 0.8) with SF, WHC, CL, and LEA, respectively. Functional studies of these genes indicated that SF was mainly related to energy metabolism, and LEA to rRNA processing. Interestingly, our data suggested that WHC is influenced by protein metabolism. Overall, the skeletal muscle transcriptome pointed to the importance of energy and protein metabolism in determining meat quality after the aging process. The panels of transcripts for beef traits may be useful for predicting meat tenderness and moisture.

Slider-Bearing Design with Micro-Machined Wavy-Cavity: Parametric Characterization of Thermohydrodynamic-Operation-Scheme

  • Ozalp B. Turker;Ozalp A. Alper
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1590-1606
    • /
    • 2006
  • Slider bearings are widely applied in mechanical systems, where the design needs cover increased load capacity, lowered friction and power consumption and creative designs. This work is governed to perform a parametric characterization, by generating a novel structure on the upper slider surface, which can formally be expressed in micro-machined wavy-form, where the individual and combined influences of various structural design parameters and boundary conditions, on the performance records, are also evaluated. Computations put forward that the contribution of the wave amplitude on power loss values is highly dependent on the level of inlet pressure; higher amplitudes are determined to increase power loss in the lowest inlet pressure case of 1.01, whereas the contrary outcome is determined in the higher inlet pressure cases of 3.01 & 5.01. Designing the slider bearing system, based on optimal load capacity, produced the optimum wave number ranges as 10-45, 7-11 and 5-8 for the pad inclinations of $5^{\circ},\;4^{\circ}$ and $3^{\circ}$ respectively.

Cyclic load testing and numerical modeling of concrete columns with substandard seismic details

  • Marefat, Mohammad S.;Khanmohammadi, Mohammad;Bahrani, Mohammad K.;Goli, Ali
    • Computers and Concrete
    • /
    • 제2권5호
    • /
    • pp.367-380
    • /
    • 2005
  • Recent earthquakes have shown that many of existing buildings in Iran sustain heavy damage due to defective seismic details. To assess vulnerability of one common type of buildings, which consists of low rise framed concrete structures, three defective and three standard columns have been tested under reversed cyclic load. The substandard specimens suffered in average 37% loss of strength and 45% loss of energy dissipation capacity relative to standard specimens, and this was mainly due to less lateral and longitudinal reinforcement and insufficient sectional dimensions. A relationship has been developed to introduce variation of plastic length under increasing displacement amplitude. At ultimate state, the length of plastic hinge is almost equal to full depth of section. Using calibrated hysteresis models, the response of different specimens under two earthquakes has been analyzed. The analysis indicated that the ratio between displacement demand and capacity of standard specimens is about unity and that of deficient ones is about 1.7.