• 제목/요약/키워드: capacitive method

검색결과 251건 처리시간 0.028초

오실로메트릭 혈압 측정에서 커패시턴스 센서와 적응필터를 이용한 새로운 잡음제거방법에 관한 연구 (A New Method for Artifact Reduction Based on Capacitive Sensor and Adaptive Filter in Oscillometric Blood Pressure Measurement)

  • 최현석;박호동;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.239-248
    • /
    • 2008
  • In this study, a new method using a capacitive sensor and an adaptive filter was proposed to deal with artifacts contaminating an oscillation signal in oscilometric blood pressure measurement. The proposed method makes use of a variation of the capacitance between an electrode fixed to a cuff and an external object to detect artifacts caused by the external object bumping into the cuff. The proposed method utilizes the adaptive filter based on linear prediction to remove the detected artifacts. The conventional method using linear interpolation and the proposed method using the adaptive filter were applied to three types of the artifact-contaminated oscillation signals(no overlap, non-consecutive overlap, and consecutive overlap between artifacts and oscillations) to compare them in terms of the artifact reduction performance. The proposed method was more robust than the conventional method in the case of consecutive overlap between artifacts and oscillations. The proposed method could be useful for measuring blood pressure in such a noisy environment that the subject is being transported.

압력 평형형 소형 베인펌프에서의 베인 이간 현상 측정 (The Measurement of Detachment of Vane Tip in a Positive Displacement Small Vane Pump)

  • 안형준;양광식;한동철;박민호
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.365-370
    • /
    • 1998
  • This paper reports on the measurement of the vane motion in a positive displacement small vane pump. The capacitive method using ceramic vane is proposed to measure the vane motion. This method enables us to measure only radial motion of the vane regardless of the motions of other directions. With simple experiments and solutions of simultaneous equations, the indirect compensation of measured signal was performed.

  • PDF

Quasi-static 근사에 의한 코플래너 도파로 불연속의 경계요소 해석 (Boundary element characterization of coplanar waveguide discontinuities by quasi-static approximation)

  • 강연덕;이택경
    • 전자공학회논문지D
    • /
    • 제34D권6호
    • /
    • pp.1-10
    • /
    • 1997
  • By using the boundary element method, the cahracterization and the circuit modelling of the coplanar waveguide (CPW) discontinuities are performed bvia quasi-static approximation. The capacitive equivalent circuits are obtained by developing the 3-D boundary element method with collocation method. On the triangular patch, the numerical scheme employed the linear basis functions and the analytic solutions of the integrals on the singular points. The capacitive discontinuities of gaps, end-gaps, and open-ends are characterized and the results compared with the conductor backed coplanar waveguides.

  • PDF

용량형 센서를 위한 마이크로컨트롤러에 기반을 둔 록인 증폭기 (A Microcontroller-Based Lock-In Amplifier for Capacitive Sensors)

  • 김청월
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.24-28
    • /
    • 2014
  • A lock-in amplifier was proposed for capacitive sensor applications. This amplifier was based on a general-purpose microcontroller and had only a charge amplifier as analog circuits. All the other functions of lock-in amplifier except for the charge amplifier were implemented with firmware and the internal resources of the microcontroller. A rectangular signal, generated by the microcontroller, was used in a sensor-driving signal instead of a conventional sinusoidal signal. This makes it possible that the phase comparison circuit in the lockin amplifier is made with analog-to-digital converter, a timer and an interrupt controller. Using the oversampling method and the rectangular driving signal, we can make it easy to implement the peak detection function with software and sample the peak-to-peak signal at charge amplifier output. A charge amplifier was proposed to cancel out the base capacitance existing in capacitive sensors structurally. The experimental results show that the lock-in amplifier operating in the supply voltage of 3.0 V cancels out the base capacitance and has good linearity.

정전용량센서를 이용한 레이저 간섭계 오차보정 (Error Correction of Laser Interferometer Using Capacitive Sensor)

  • 김재천;서석현;전재욱;박기헌;유관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.342-344
    • /
    • 2006
  • During last years, large investments have been directed to development and research of nano-technological products like semiconductor, display panel, optic-fiber communication components, life technology, and ultra-precision components. All quantitative measurements at nanometre scale should guarantees accurate results and high quality. Laser interferometer is one of most famous nanometre scale devices to be able to measure metre-scale distance with nanometre scale resolution, but it is easily affected by various error causes like geometrical, instrumental and environmental factor. On the other side, capacitive sensor is robust to above error factors, but it is able to measure relatively shorter distance, under $100{\mu}m$, than laser interferometer. New error correction method for laser interferometry using capacitive sensor will be introduced in this paper.

  • PDF

폴리이미드 박막과 스퍼터링 방법으로 증착한 상부금속 그레인이 용량형 습도센서의 전기적 특성에 미치는 영향 (Effects of the Electrical Characteristics of Capacitive Relative Humidity Sensor by Polyimide Film and Upper Electrode Grain by Sputtering Method)

  • 이진민
    • 한국전기전자재료학회논문지
    • /
    • 제24권3호
    • /
    • pp.224-228
    • /
    • 2011
  • This research, integratable capacitive relative humidity sensor was produced using polyimide on glass substrate. Also, at the time of upper electrode formation, upper electrode grain size was affected by giving changes to sputtering condition. Through this analyzing electrical characteristics affect from capacitive relative humidity sensor was possible. Capacitance of capacitive relative humidity sensor was 330 pF, linearity of 0.6%FS and it showed less than 3% of low hysterisis. Specially, hysterisis was affected more from interface than interstitial. Also was affected by the grain size which is one of the formation condition of upper electrode.

CALIBRATION OF A NEW CAPACITIVE TORQUE SENSOR FOR MEASURING BASIC MAGNETIC CHARACTERISTICS WITH ELECTROMAGNETIC AND GRAVITATIONAL FORCES

  • Kim, M.Y.;Choi, K.L.;Choi, S.J.;Song, E.Y.;Lee, Y.H.;Hee, J.R.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.786-789
    • /
    • 1995
  • With a newly designed capacitive torque sensor a multipurpose magnetometer for measuring basic magnetic characteristics such as hyteresis loops, magnetic anisotropy and magnetostriction was built. In order to calibrate the capacitive torque sensor, we measured the output voltages of the sensor by applying the torques due to the electromagnetic and gravitational forces. Experimental results of the several calibration method for the capacitive torque sensor showed good agreement within 3 %.

  • PDF

RLS 알고리즘을 이용한 원격 RF 센서 시스템의 정전용량 파라메타 추정 (Capacitive Parameter Estimation of Passive Telemetry RF Sensor System Using RLS Algorithm)

  • 김경엽;이준탁
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.858-865
    • /
    • 2008
  • In this paper, Capacitive Telemetry RF Sensor System using Recursive Least Square (RLS) algorithm was proposed. General Telemetry RF Sensor System means that it should be "wireless", "implantable" and "batterless". Conventional Telemetry RF Sensor System adopts Integrated Circuit type, but there are many defects like complexity of structure and the limitation of large power consumption in some cases. In order to overcome these disadvantages, Telemetry RF Sensor System based on inductive coupling principle was proposed in this paper. Proposed Telemetry RF Sensor System is very simple because it consists of R, L and C and measures the changes of environment like pressure and humidity in the type of capacitive value. This system adopted RLS algorithm for estimation of this capacitive parameter. For the purpose of applying RLS algorithm, proposed system was mathematically modelled with phasor method and was quasi-linearized. As two parameters such as phase and amplitude of output voltage for estimation were needed, Phase Difference Detector and Amplitude Detector were proposed respectively which were implemented using TMS320C2812 made by Texas Instrument. Finally, It is verified that the capacitance of proposed telemetry RF Sensor System using RLS algorithm can be estimated efficiently under noisy environment.

코플래너 웨이브가이드 불연속에 대한 용량성 등가회로 모델링 (Capacitive Equivalent Circuit Modeling for Coplanar Waveguide Discontinuities)

  • 박기동;임영석
    • 한국전자파학회논문지
    • /
    • 제8권5호
    • /
    • pp.486-487
    • /
    • 1997
  • 본 논문은 CPW 불연속 중 개방단, 연결된 접지면을 갖는 개방단, 캡, 개방단 CPW 스터브에 대한 순수 용량 성 집중소자 등가회로를 제시하였으며, 불연속의 불리적 차원과 주파수 함수로써 등가회로의 커패시턴스값을 나 타내었다. 커패시턴스값은 3차원 유한차분 시간영역볍(3D-FDTD)을 적용하여 계산한 주파수 영역 산란 파라미 터로부터 이끌어냈다. 개방단, 연결된 접지변을 갖는 개방단 및 캡 불연속에 대해 FDTD으로 계산한 커패시턴스 값을 3차원 유한 차분볍(3D- FDM)으로 계산한 준정적 결과와 비교하였다.

  • PDF

반사 신호를 이용한 용량 성 센서의 신호처리 및 이를 이용한 초정밀 간극 측정 (Reflective Signal Based Signal Contioning of Capacitive Sensor and High Precision Gap Measurement)

  • 김재근;이택주;임수철;박경수;박노철;박영필;엄원석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.537-537
    • /
    • 2010
  • High precision sensing is very important in various technologies. Especially, it is more important when it were applied to nano/micro meter level's sensing like AFM, storage, etc. And capacitive sensing is widely used method. To improve the measurement efficiency, many signal conditioners were studied and one of them was surface acoustic wave (SAW) device. SAW device is very widely used as a high frequency bandwidth filter. Due to the reflective characteristic of high frequency, the response of SAW device contains both propagative and reflective signal at the external impedance. In this paper, we used SAW device as signal conditioner of capacitive sensor. And high precision gap measurement was executed using capacitive load. Reference signal was reflective SAW response and the magnitude at the center frequency of SAW device by the change of impedance was checked. Finally, the attainable gap resolution was determined.

  • PDF